1.
Phys Med Biol ; 53(11): 3007-21, 2008 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-18490812

RESUMO

In this study, we present an analytical approach for optimizing the leaf design of a multi-leaf collimator (MLC) in a linear accelerator. Because leaf designs vary between vendors, our goal is to characterize and quantify the effects of different compromises which have to be made between performance parameters. Subsequently, an optimal leaf design for an earlier proposed six-bank MLC which combines a high-resolution field-shaping ability with a large field size is determined. To this end a model of the linac is created that includes the following parameters: the source size, the maximum field size, the distance between source and isocenter, and the leaf's design parameters. First, the optimal radius of the leaf tip was found. This optimum was defined by the requirement that the fluence intensity should fall from 80% of the maximum value to 20% in a minimal distance, defining the width of the fluence penumbra. A second requirement was that this penumbra width should be constant when a leaf moves from one side of the field to the other. The geometric, transmission and total penumbra width (80-20%) were calculated depending on the design parameters. The analytical model is in agreement with Elekta, Varian and Siemens collimator designs. For leaves thinner than 4 cm, the transmission penumbra becomes dominant, and for leaves close to the source the geometric penumbra plays a role. Finally, by choosing the leaf thickness of 3.5 cm, 4 cm and 5 cm from the lowest to the highest bank, respectively, an optimal leaf design for a six-bank MLC is achieved.


Assuntos
Aceleradores de Partículas/instrumentação , Planejamento da Radioterapia Assistida por Computador
2.
Phys Med Biol ; 52(1): 169-82, 2007 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-17183134

RESUMO

In this study, we quantify the impact of linac/MLC design parameters on IMRT treatment plans. The investigated parameters were leaf width in the MLC, leaf transmission, related to the thickness of the leaves, and penumbra related primarily to the source size. Seven head-and-neck patients with stage T1-T3N0-N2cM0 oropharyngeal cancer were studied. For each patient nine plans were made with a different set of linac/MLC parameters. The plans were optimized in Pinnacle(3) v7.6c and PLATO RTS v2.6.4, ITP v1.1.8. A hypothetical ideal linac/MLC was introduced to investigate the influence of one parameter at a time without interaction of other parameters. When any of the three parameters was increased from the ideal set-up values (leaf width 2.5 mm, transmission 0%, penumbra 3 mm), the mean dose to the parotid glands increased, given the same tumour coverage. The largest increase was found for increasing leaf transmission. The investigation showed that by changing more than one parameter of the ideal linac/MLC set-up, the increase in the mean dose was smaller than the sum of dose increments for each parameter separately. As a reference to clinical practice, we also optimized the plans of the seven patients with the clinically used Elekta SLi 15, equipped with a standard MLC with a leaf width of 10 mm. As compared to the ideal linac, this resulted in an increase of the average dose to the parotid glands of 5.8 Gy.


Assuntos
Desenho de Equipamento , Neoplasias de Cabeça e Pescoço/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Relação Dose-Resposta à Radiação , Humanos , Neoplasias Orofaríngeas/radioterapia , Glândula Parótida/efeitos da radiação , Aceleradores de Partículas , Radiometria/métodos , Dosagem Radioterapêutica , Tomografia Computadorizada por Raios X
3.
Phys Med Biol ; 50(9): 2015-31, 2005 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-15843734

RESUMO

In this study, we present a sequencer for delivering step-and-shoot IMRT using a six-bank multi-leaf system. Such a system was proposed earlier and combines a high-resolution field-shaping ability with a large field size. It consists of three layers of two opposing leaf banks with 1 cm leaves. The layers are rotated relative to each other at 60 degrees . A low-resolution mode of sequencing is achieved by using one layer of leaves as primary MLC, while the other two are used to improve back-up collimation. For high-resolution sequencing, an algorithm is presented that creates segments shaped by all six banks. Compared to a hypothetical mini-MLC with 0.4 cm leaves, a similar performance can be achieved, but a trade-off has to be made between accuracy and the number of segments.


Assuntos
Algoritmos , Análise de Falha de Equipamento/métodos , Modelos Biológicos , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/instrumentação , Radioterapia Conformacional/métodos , Simulação por Computador , Fracionamento da Dose de Radiação , Humanos , Dosagem Radioterapêutica , Eficiência Biológica Relativa , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Phys Med Biol ; 49(12): 2645-56, 2004 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-15272679

RESUMO

In this study, we present the design for an alternative MLC system that allows high precision shaping of large fields. The MLC system consists of three layers of two opposing leaf banks. The layers are rotated 60 degrees relative to each other. The leaves in each bank have a standard width of 1 cm projected at the isocentre. Because of the symmetry of the collimator set-up it is expected that collimator rotation will not be required, thus simplifying the construction considerably. A 3D ray tracing computer program was developed in order to simulate the fluence profile for a given collimator and used to optimize the design and investigate its performance. The simulations show that a six-bank collimator will afford field shaping of fields of about 40 cm diameter with a precision comparable to that of existing mini MLCs with a leaf width of 4 mm.


Assuntos
Análise de Falha de Equipamento/métodos , Modelos Estatísticos , Radiometria/métodos , Radioterapia Conformacional/instrumentação , Simulação por Computador , Desenho de Equipamento , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade