Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
J Surg Res ; 296: 256-264, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38295713

RESUMO

INTRODUCTION: Resuscitative endovascular balloon occlusion of the aorta (REBOA) has the potential to cause clinically relevant systemic ischemic burden with long durations of aortic occlusion (AO). We aimed to examine the association between balloon occlusion time and clinical complications and mortality outcomes in patients undergoing zone 1 REBOA. METHODS: A retrospective cohort analysis of American Association for the Surgery of Trauma Aortic Occlusion for Resuscitation in Trauma and Acuteregistry patients with Zone 1 REBOA between 2013 and 2022 was performed. Patients with cardiopulmonary resuscitation on arrival or who did not survive past the emergency department were excluded. Total AO times were categorized as follows: <15 min, 15-30 min, 31-60 min, and >60 min. Clinical and procedural variables and in-hospital outcomes were compared across groups using bivariate and multivariate regression analyses. RESULTS: There were 327 cases meeting inclusion criteria (n = 51 < 15 min, 83 15-30 min, 98 31-60 min, and 95 > 60 min, respectively). AO >60 min had higher admission lactate (8 ± 6; P = 0.004) compared to all other time groups, but injury severity score, heart rate, and systolic blood pressure were similar. Group average times from admission to definitive hemorrhage control ranged from 82 to 103 min and were similar across groups (85 min in AO >60 group). Longer AO times were associated with greater red blood cell, fresh frozen plasma transfusions (P < 0.001), and vasopressor use (P = 0.001). Mortality was greatest in the >60 min group (73%) versus the <15 min, 15-30 min, and 31-60 min groups (53%, 43%, and 45%, P < 0.001). With adjustment for injury severity score, systolic blood pressure, and lactate, AO >60 min had greater mortality (OR 3.7, 95% CI 1.6-9.4; P < 0.001) than other AO duration groups. Among 153 survivors, AO >60 min had a higher rate of multiple organ failure (15.4%) compared to the other AO durations (0%, 0%, and 4%, P = 0.02). There were no differences in amputation rates (0.7%) or spinal cord ischemia (1.4%). acute kidney injury was seen in 41% of >60 min versus 21%, 27%, and 33%, P = 0.42. CONCLUSIONS: Though greater preocclusion physiologic injury may have been present, REBOA-induced ischemic insult was correlated with poor patient outcomes, specifically, REBOA inflation time >60 min had higher rates of mortality and multiple organ failure. Minimizing AO duration should be prioritized, and AO should not delay achieving definitive hemostasis. Partial REBOA may be a solution to extend safe AO time and deserves further study.


Assuntos
Oclusão com Balão , Reanimação Cardiopulmonar , Procedimentos Endovasculares , Choque Hemorrágico , Humanos , Estudos Retrospectivos , Insuficiência de Múltiplos Órgãos , Aorta/cirurgia , Ressuscitação , Escala de Gravidade do Ferimento , Oclusão com Balão/efeitos adversos , Lactatos , Procedimentos Endovasculares/efeitos adversos , Choque Hemorrágico/etiologia , Choque Hemorrágico/terapia
2.
Geriatr Orthop Surg Rehabil ; 14: 21514593231200797, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37701926

RESUMO

Background: In-hospital mortality and discharge disposition following traumatic hip fractures previously reported in the literature, has mainly focused on a nationwide scale, which may not be reflective of unique populations. Objective: Our aim was to characterize demographics, hospital disposition, and associated outcomes for patients with the most common hip fractures. Methods: A retrospective study utilizing the Trauma Registry from the Texas Department of State Health Services. Patient demographics, injury characteristics, and outcomes, such as in-hospital mortality, and discharge dispositions, were collected. The data were analyzed via univariate analysis and multivariate regressions. Results: There were 17,104 included patients, composed of 45% femoral neck fractures (FN) and 55% intertrochanteric fractures (IT). There were no differences in injury severity score (ISS) (9 ± 1.8) or age (77.4 ± 8 years old) between fracture types. In-hospital mortality risk was low but different among fracture types (intertrochanteric, 1.9% vs femoral neck, 1.3%, P = .004). However, when controlling for age, and ISS, intertrochanteric fractures and Hispanic patients were associated with higher mortality (P < .001, OR 1.5, 95% CI 1.1-2.0). Uninsured, and Black/African American (P = .05, OR 1.2, 95% CI 1.1-1.3) and Hispanic (P < .001, OR 1.2, 95% CI 1.1-1.3) patients were more likely to be discharged home after adjusting for age, ISS, and payment method. Conclusion: Regardless of age, severity of the injury or admission hemodynamics, intertrochanteric fractures and Hispanic/Latino patients had an increased risk of in-hospital mortality. Patients who were uninsured, Hispanic, or Black were discharged home rather than to rehabilitation, regardless of age, ISS, or payment method.

3.
Ann Thorac Surg ; 116(4): 845-852, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37423345

RESUMO

BACKGROUND: Given the uncertainty of US health care finances, an understanding of reimbursement trends has become increasingly important in the field of cardiac surgery. We aimed to assess Medicare reimbursement trends for common cardiac surgical procedures from 2000 to 2022. METHODS: Reimbursement data were extracted from the Centers for Medicare and Medicaid Services Physician Fee Schedule Look-Up Tool during the study period for 6 common cardiac operations: aortic valve replacement, mitral valve repair and replacement, tricuspid valve replacement, Bentall procedure, and coronary artery bypass grafting. Reimbursement rates were adjusted for inflation to 2022 US dollars using the Consumer Price Index. Total percentage change and compound annual growth rate were calculated. A split-time analysis was performed to assess trends before and after 2015. Least squares and linear regressions were performed. The R2 value was calculated for each procedure, and slope was used to determine change in reimbursements over time. RESULTS: Inflation-adjusted reimbursement decreased by 34.1% during the study period. The overall compound annual growth rate was -1.8%. Reimbursement trends differed by procedure (P < .001), with all reimbursements trending down (R2 > 0.62), except for mitral valve replacement (P = .21) and tricuspid valve replacement (P = .43). Coronary artery bypass grafting decreased the most (-44.4%), followed by aortic valve replacement (-40.1%), mitral valve repair (-38.5%), mitral valve replacement (-29.8%), Bentall procedure (-28.5%), and tricuspid valve replacement (-25.3%). In split-time analysis, reimbursement rates did not significantly change from 2000 to 2015 (P = .24) but decreased significantly from 2016 to 2022 (P = .001). CONCLUSIONS: Medicare reimbursement significantly decreased for most cardiac surgical procedures. These trends justify further advocacy by The Society of Thoracic Surgeons to maintain access to quality cardiac surgical care.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Medicare , Idoso , Humanos , Estados Unidos , Valva Aórtica/cirurgia , Ponte de Artéria Coronária , Qualidade da Assistência à Saúde , Reembolso de Seguro de Saúde
4.
J Surg Res ; 290: 203-208, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37271068

RESUMO

INTRODUCTION: With the use of resuscitative endovascular balloon occlusion of the aorta (REBOA) comes the potential for vascular access site complications (VASCs) and limb ischemic sequelae. We aimed to determine the prevalence of VASC and associated clinical and technical factors. METHODS: A retrospective cohort analysis of 24-h survivors undergoing percutaneous REBOA via the femoral artery in the American Association for the Surgery of Trauma Aortic Occlusion for Resuscitation in Trauma and Acute care surgery registry between Oct 2013 and Sep 2021 was performed. The primary outcome was VASC, defined as at least one of the following: hematoma, pseudoaneurysm, arteriovenous fistula, arterial stenosis, or the use of patch angioplasty for arterial closure. Associated clinical and procedural variables were examined. Data were analyzed using Fisher exact test, Mann-Whitney-U tests, and linear regression. RESULTS: There were 34 (7%) cases with VASC among 485 meeting inclusion criteria. Hematoma (40%) was the most common, followed by pseudoaneurysm (26%) and patch angioplasty (21%). No differences in demographics or injury/shock severity were noted between cases with and without VASC. The use of ultrasound (US) was protective (VASC, 35% versus no VASC, 51%; P = 0.05). The VASC rate in US cases was 12/242 (5%) versus 22/240 (9.2%) without US. Arterial sheath size >7 Fr was not associated with VASC. US use increased over time (R2 = 0.94, P < 0.001) with a stable rate of VASC (R2 = 0.78, P = 0.61). VASC were associated with limb ischemia (VASC, 15% versus no VASC, 4%; P = 0.006) and arterial bypass procedures (VASC 3% versus no VASC 0%; P < 0.001) but amputation was uncommon (VASC, 3% versus no VASC, 0.4%; P = 0.07). CONCLUSIONS: Percutaneous femoral REBOA had a 7% VASC rate which was stable over time. VASC are associated with limb ischemia but need for surgical intervention and/or amputation is rare. The use of US-guided access appears to be protective against VASC and is recommended for use in all percutaneous femoral REBOA procedures.


Assuntos
Falso Aneurisma , Oclusão com Balão , Procedimentos Endovasculares , Choque Hemorrágico , Humanos , Estudos Retrospectivos , Aorta , Ressuscitação/métodos , Choque Hemorrágico/epidemiologia , Choque Hemorrágico/etiologia , Choque Hemorrágico/terapia , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Oclusão com Balão/efeitos adversos , Oclusão com Balão/métodos , Hematoma
5.
Semin Vasc Surg ; 36(2): 234-249, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37330237

RESUMO

Acute mesenteric ischemia (AMI) constitutes a life-threatening problem that can result in death, multiorgan failure, and severe nutritional disability. Although AMI is a rare cause of acute abdominal emergencies, ranging between 1 and 2 individuals per 10,000, the morbidity and mortality rates are high. Arterial embolic etiology composes nearly one-half of AMIs, with a sudden onset of severe abdominal pain considered the most common symptom. Arterial thrombosis is the second most common cause of AMI, which presents similarly to arterial embolic AMI, although often more severe due to anatomic differences. Veno-occlusive causes of AMI are the third most common and are associated with an insidious onset of vague abdominal pain. Each patient is unique, and the treatment plan should be tailored to their individual needs. This may include considering the patient's age, comorbidities, and overall health, as well as their preferences and personal circumstances. A multidisciplinary approach involving specialists from different fields, such as surgeons, interventional radiologists, and intensivists, is recommended for the best possible outcome. Potential challenges in tailoring an optimal treatment plan for AMI may include delayed diagnosis, limited availability of specialized care, or patient factors that make some interventions less feasible. Addressing these challenges requires a proactive and collaborative approach, with regular review and adjustment of the treatment plan as needed to ensure the best possible outcome for each patient.


Assuntos
Embolia , Isquemia Mesentérica , Trombose , Humanos , Emergências , Mesentério , Isquemia Mesentérica/diagnóstico por imagem , Isquemia Mesentérica/terapia , Embolia/complicações , Doença Aguda , Resultado do Tratamento , Estudos Retrospectivos
6.
Ann Vasc Surg ; 97: 18-26, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37068623

RESUMO

BACKGROUND: Thoracic aortic stent grafts are thought to decrease aortic compliance and may contribute to hypertension and heart failure after thoracic endovascular aortic repair (TEVAR). Left ventricular (LV) biomechanics immediately after TEVAR, however, have not been quantified. Pressure-volume (PV) loop analysis provides gold-standard LV functional information. The aim of this study is to use an LV PV loop catheter and analysis to characterize the LV biomechanics before and acutely after TEVAR. METHODS: Anesthetized Yorkshire swine (N = 6) were percutaneously instrumented with an LV PV loop catheter. A 20 mm × 10 cm stent graft was deployed distal to the left subclavian via the femoral artery under fluoroscopy. Cardiac biomechanics were assessed before and after TEVAR. As a sensitivity analysis, inferior vena cava occlusion with PV loop assessment was performed pre and post-TEVAR in 1 animal to obtain preload and afterload-independent end-systolic and end-diastolic PV relationships (ESPVR and EDPVR). RESULTS: All animals underwent successful instrumentation and TEVAR. Post-TEVAR, all 6 animals had higher mean LV ESP (106 vs. 118 mm Hg, P = 0.04), with no change in the EDPVR. inferior vena cava occlusion also moved the ESPVR curve upward and leftward, indicating increased LV work per unit time. There was no augmentation of EDPVR following TEVAR (P > 0.05). Postmortem exams in all animals revealed appropriate stent placement and no technical complications. CONCLUSIONS: TEVAR was associated with an acute increase in LV end-systolic pressure and shift in the ESPVR, indicating increased ventricular work. This data provides potential mechanistic insights into the development of post-TEVAR hypertension and heart failure. Future stent graft innovation should focus on minimizing the changes in cardiac physiology.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Insuficiência Cardíaca , Hipertensão , Suínos , Animais , Aneurisma da Aorta Torácica/cirurgia , Fenômenos Biomecânicos , Resultado do Tratamento , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Procedimentos Endovasculares/efeitos adversos , Insuficiência Cardíaca/etiologia , Stents , Implante de Prótese Vascular/efeitos adversos , Estudos Retrospectivos , Prótese Vascular
7.
Vascular ; : 17085381231162121, 2023 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-36880298

RESUMO

OBJECTIVE: Thoracic Endovascular Aortic Repair (TEVAR) is well established in humans. Despite widespread use, additional research questions related to thoracic aortic stenting and endovascular innovation require large animal models. Translating human TEVAR devices and techniques into animal models, however, is a challenge even for experienced endovascular surgeons looking to develop a large animal TEVAR model.This article describes swine-specific strategies to deploy human TEVAR stent grafts, delineate how to select, size, prepare, and re-use human stents and deployment systems in swine, and how to translate human imaging modalities to large animal TEVAR. METHODS: We describe a selection of related TEVAR models and techniques in Yorkshire swine to support scientific inquiry. This includes an animal husbandry and pre-operative preparation and planning program. All imaged specimens in this paper are castrated male Yorkshire swine in the 60-80 kg range and underwent TEVAR with the Medtronic Navion stent and deployment system. RESULTS: To study human aortic stent grafts in swine, the animals generally must be at least 50 kgs to guarantee a 2 cm internal aortic diameter at the left subclavian, and for the iliac arteries to accommodate the human deployment system. Swine will have longer torsos and shorter iliofemoral segments than a human of the same weight which can make human deployment systems too short to reach the left subclavian from the femoral arteries in larger animals. We provide techniques to overcome this, including open iliac access or upside-down carotid TEVAR, which may be particularly useful if the scientific data would be confounded by iliofemoral access.Unlike humans that present clinically with axial imaging, swine will generally not have preoperative imaging, and many translational research laboratories do not have access to inexpensive preoperative CT, or any intraoperative CT scanning, which we are fortunate to have. We describe, therefore, several strategies for imaging in this setting including TEVAR via C-arm fluoroscopy and with or without in-laboratory CT scanning. Due to the low-resource setting of most large animal laboratories, as compared to a human hybrid room, we also describe several techniques to reduce cost and reuse materials, including the stent grafts, which at the end of non-survival experiments can be recovered during necropsy, cleaned, reinserted into the deployment device and reused on additional animals. CONCLUSIONS: This article describes a collection of related techniques and tips to translate human TEVAR imaging, sizing/selection, deployment, and anatomy to swine research. Using this framework alone, an experienced human vascular or endovascular surgeon may develop a complete aortic stenting animal model with strategies for scientific data acquisition.

8.
Angiology ; : 33197231155225, 2023 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-36753679

RESUMO

Intraoperative computed tomography (CT) imaging with endovascular delivery of intra-arterial (IA) contrast could potentially provide higher attenuation with lower contrast volumes than intravenous (IV) administration. We aimed to compare IA and IV contrast use for organ-specific CT abdominal imaging. Five anesthetized swine had external jugular and brachial artery access with ascending aortic pigtail placement. An IV protocol was 100 mL at 5 mL/sec over 20 sec vs 50 mL of IA contrast at 5 mL/sec over 10 sec. Region-of-interest markers were applied to anatomical regions to measure attenuation (HU) over time. IA and IV contrast protocols achieved adequate aortic opacification (IA, 455 ± 289 vs IV, 450 ± 114 HU). The IA contrast aortic attenuation curve reached peak attenuation compared with IV contrast (IA, 8 vs 23 sec; P < .001). Time to peak attenuation was similar between IA and IV contrast in the portal vein (IA, 38 vs IV, 42 sec, P = .25). IA administration achieved a superior contrast-to-noise ratio (CNR) in less time compared with IV (R2 = .94; P < .001). IA contrast achieved adequate opacification with less bolus broadening and a superior CNR compared with IV contrast while using a smaller contrast volume for directed organ-directed imaging.

9.
J Vasc Surg ; 77(5): 1522-1530.e6, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36702173

RESUMO

BACKGROUND: As vascular surgery training continues to evolve with the growth of integrated vascular surgery residency (0+5) programs and the consolidation of fellowship programs, optimizing all aspects of the education for vascular surgery trainees, both fellows and 0+5 residents, has become increasingly important. In the present study, we aimed to determine the prevalence, quality, and content of vascular surgery education publications across journals. METHODS: Journal websites (n = 26) and PubMed were queried to identify vascular surgery education publications from 2012 to 2021. The publications were organized into 11 content categories: (1) curriculum, (2) simulation, (3) trainee assessment, (4) program evaluation, (5) wellness/burnout, (6) diversity/inclusion, (7) mentorship/career, (8) case outcomes, (9) perceptions of training, (10) social media, and (11) other. Publication interactivity and quality were measured via PlumX data and Medical Education Research Study Quality Instrument scores. The data were analyzed via univariate analysis and linear regression. RESULTS: A total of 115 vascular surgery education publications (0.2% [interquartile range (IQR), 0.04%-0.5%] of total publications) were identified from the selected journals. The Journal of Vascular Surgery had the highest proportion (0.8%) of vascular surgery education publications, followed by the Journal of Surgical Education (0.7%) and Annals of Vascular Surgery (0.6%). Vascular surgery journals constituted most (79%) of the publications. Of the authors, 15% (IQR, 0%-25%) had a master's or doctorate degree in education. Senior authors were more often identified as male gender (77%), and more first authors (41%) were identified as female gender. An interactivity analysis showed that there were 10.3 citations (IQR, 12), 33.1 captures (IQR, 34), and 8.4 social media interactions (IQR 14) per publication. The educational quality had a median Medical Education Research Study Quality Instrument score of 11 (IQR, 9-12.5), with 49% of publications having a score greater than the median. Publications on training (44% curriculum and 20% simulation) were significantly more frequent than other topics (P < .001), with no change in the publication content over 10 years (P = .29). The volume of vascular surgery education publications did not change during the study period (P = .13) despite the ongoing changes in the educational environment. CONCLUSIONS: Despite the increasing importance placed on vascular surgery education by national vascular societies, publications on vascular surgery education have remained sparse among all journals. Also, the vascular surgery educational content has not changed during the past 10 years, with a primary focus on curriculum and simulation training. Further promotion of vascular surgery educational research is required to increase the quality, volume, and diversity of education publications.


Assuntos
Educação de Pós-Graduação em Medicina , Internato e Residência , Humanos , Masculino , Feminino , Escolaridade , Currículo , Procedimentos Cirúrgicos Vasculares/educação
10.
Ann Vasc Surg ; 89: 293-301, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36441096

RESUMO

BACKGROUND: Acute arterial occlusion of the lower extremity is a time-dependent emergency that requires prompt revascularization. Lower extremity extracorporeal distal revascularization (LEEDR) is a technique that can be initiated bedside when definitive therapy is delayed. The aim of this study is to evaluate this technique in a swine model of prolonged extremity ischemia. METHODS: Anesthetized swine underwent right femoral and left posterior tibial artery cannulation, left iliac venous flow monitoring (mL/min), and continuous left anterior compartment pressure (CP) monitoring (mm Hg). The iliac artery was clamped for 6 hr. LEEDR animals underwent 5 hr of extracorporeal femoral-to-tibial blood flow at 150 mL/min; controls had no intervention. At 6 hr, LEEDR was discontinued, iliac flow restored, and anterior CP monitored for 3 hr. RESULTS: Baseline characteristics were similar across both the groups. Iliac clamping saw an expected fall in iliac venous flow (258 ± 30 to 82 ± 19; P < 0.001). LEEDR resulted in a rise in iliac venous flow (82 ± 20 to 181 ± 16; P < 0.001); control arm flow remained reduced (71 ± 8; P < 0.001). Once inflow was restored, venous flow returned to baseline. Revascularization provoked a higher peak CP in the control arm versus in the LEEDR group (25 ± 5 vs. 6 ± 1; P = 0.02). CONCLUSIONS: An extracorporeal circuit can temporarily revascularize an extremity in a swine model of prolonged ischemia, mitigating reperfusion injury and maintaining normal CPs. This concept should undergo further evaluation as a bedside tool to mitigate extremity ischemia prior to definitive revascularization.


Assuntos
Arteriopatias Oclusivas , Extremidade Inferior , Suínos , Animais , Resultado do Tratamento , Extremidade Inferior/irrigação sanguínea , Isquemia/terapia , Procedimentos Cirúrgicos Vasculares , Arteriopatias Oclusivas/terapia
11.
Patient Saf Surg ; 16(1): 39, 2022 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-36522769

RESUMO

Popliteal artery injury following knee dislocation is associated with significant morbidity and high amputation rates. The complex and multi-disciplinary input required to manage this injury effectively can take time to arrange, prolonging the time to revascularization. Furthermore, open surgical bypass or interposition graft can be technically challenging in the acute setting, further prolonging ischemic time.Temporary intravascular shunts can be used to temporarily restore flow but require surgical exposure which takes time. Endovascular techniques can decrease the time to revascularization; however, endovascular popliteal stent-grafting is controversial because the biomechanical forces relating to flexion and extension of the knee may increase the risk of stent thrombosis. An ideal operation would result in rapid revascularization, eventually leading to a definitive and durable surgical solution.We hypothesize that a staged approach combing extracorporeal shunting, temporary endovascular covered stent placement, external fixation of bony injury, and definitive open repair provides for a superior approach to popliteal artery injury than current standard of care. We term this approach lower extremity staged revascularization (LESR) and the aim is to minimize the known factors contributing to poor outcomes after traumatic popliteal artery injury.

12.
J Vasc Surg ; 76(3): 837-843.e4, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35470017

RESUMO

OBJECTIVES: Recruitment into the vascular surgery specialty is an imperative as the specialty faces significant demographic changes. Due to the changing dynamics in vascular surgery training pathways, we sought to review current literature on recruitment strategies and their effectiveness with medical students and general surgery residents. METHODS: A systematic search, following Preferred Reporting Items for Systematic reviews and Meta-Analyses guidelines, was performed by searching MEDLINE, EMBASE, Scopus, Cumulative Index to Nursing and Allied Health Literature (CINAHL), and Education Resources Information Center (ERIC) databases for studies on vascular surgery recruitment methods for medical students and general surgery residents from inception of databases to December 31, 2021. Reports in English discussing recruitment strategies were included. Reports lacking recruitment method data and those with insufficient data were excluded. RESULTS: Ten reports met inclusion criteria and studied a total of 688 participants. Seven reports (70%) employed simulation, didactic, or online courses. The remaining 30% of studies included data on mentorship, research, or other interventions. Most of the studies (50%) reported data for medical students (MS1-MS4). Interventions specific to residents or both students and residents comprised the other 50% of studies. Simulation and didactic courses increased interest in vascular surgery by a median of 50% (interquartile range, 38%-64%) for both medical students and residents. Importantly, without reinforcement, interest was seen to decrease over time. CONCLUSIONS: Recruitment interventions are useful in increasing student interest in vascular surgery. Early exposure to simulated vascular surgery procedures and mentorship are cited as common reasons for entering the field. Further studies on recruitment strategies focused on long-term outcomes are required.


Assuntos
Especialidades Cirúrgicas , Estudantes de Medicina , Simulação por Computador , Humanos , Mentores , Especialidades Cirúrgicas/educação , Procedimentos Cirúrgicos Vasculares/efeitos adversos , Procedimentos Cirúrgicos Vasculares/educação
13.
Ann Vasc Surg ; 87: 263-269, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35341938

RESUMO

BACKGROUND: Integrated vascular surgery residency (VS) programs have increased in popularity and offer an accelerated track compared to the traditional fellowship pathway. We sought to create a simple metric for medical students to better assess the competitiveness of VS training programs compared to general surgery (GS) programs. METHODS: GS and VS programs were compared using the National Resident Matching Program match data from 2012 to 2021. Applicant metrics (board scores, research output and experiences, work experiences, and volunteer experiences) from 2015 to 2019 were obtained using the Association of American Medical Colleges Report on Residents. A competitive index (CI) was created (number of programs ranked per applicant divided by match rate) for each specialty and normalized (NCI) to a value of 1 to improve longitudinal comparisons. NCI and number of programs ranked per applicant were plotted across time and a linear regression was performed to evaluate a 10-year trend. RESULTS: The match rate of both specialties was 52% and was similar for GS and VS programs. CI was higher for VS compared to GS (18.4 ± 3.0 vs. 14.5 ± 0.4; P < 0.001). The number of programs ranked per applicant was higher in VS compared to GS (9.4 vs. 7.7, P < 0.05). The linear regression revealed increasing NCI and number of programs ranked per applicant over time for VS programs compared to GS with all R2 > 0.61 (P < 0.001). CONCLUSIONS: Matching into a VS programs is becoming increasingly competitive. The average CI was approximately 27% higher for VS programs compared to GS programs despite similar match rates. As VS programs continue to evolve, NCI may be a more useful metric for applicants.


Assuntos
Internato e Residência , Humanos , Estados Unidos , Resultado do Tratamento , Bolsas de Estudo , Procedimentos Cirúrgicos Vasculares/educação
14.
Am J Surg ; 224(2): 796-808, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35067354

RESUMO

BACKGROUND: Trainees in difficulty require additional support to complete training program and become successful physicians. This study reviewed the current remediation practices and outcomes of trainees in difficulty. METHODS: A PRISMA-based literature review was performed. Meta-analyses were performed using random effects model. RESULTS: 30 studies met inclusion criteria. Sixteen studies surveyed program directors and 14 were observational. Prevalence and attrition of trainees in difficulty ranged widely from 2.0% to 30.7% and 0.0%-50.0%, respectively, with significant heterogeneity. Pooled odds of attrition was higher for trainees in difficulty, however, the confidence interval crossed one and there was statistically significant heterogeneity. Residents in difficulty were significantly less likely to become board certified (OR = 0.08, 95%-CI = 0.04-0.18; I2 = 0%, P = .70). CONCLUSION: Trainees in difficulty were less likely to be board certified but attrition rate did not differ. Future studies with standardized criteria for trainees in difficulty and better reporting of the outcomes can better guide our remediation practices.


Assuntos
Internato e Residência , Educação de Pós-Graduação em Medicina , Humanos , Inquéritos e Questionários
15.
Ann Vasc Surg ; 83: 1-9, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34995744

RESUMO

BACKGROUND: The burden of peripheral artery disease is significant for public health but the readily available on-line information on the disease is poorly studied. This study seeks to evaluate the quality and readability of patient resources and identify gaps that appear in the top search results for peripheral artery disease. METHODS: Internet searches were performed for "PAD" and "Peripheral Artery Disease" and "PVD" on three search engines and two metasearch engines. The top 30 websites from each search engine were compiled, screened, and evaluated across four categories of information to assess overall quality: accountability, interactivity, structure, and content. Four indices were used to evaluate readability of the text for the viewer. Statistical analyses was performed using Rstudio with ANOVA. RESULTS: Sixty-three websites met inclusion criteria, of which 25 were open access (34.9%), 30 were from hospital/healthcare organization (48%), 5 were from a governmental agency (8%), 4 were industry sponsored (6%), and 2 were from professional medical societies (3%). Median total quality score was 19 out of 47 (IQR, 15 -30): of the components of this score, accountability was 5 out of 17 (2 -10), interactivity was 2 out of 5 (2.0 -2.0), site structure was 3 out of 4 (2.5 -3.0), and site content was 11 out of 21 (7 -14). Total score varied significantly by organization type (P = 0.007). Open access (30, 17 -34, median, IQR) and governmental agency (30, 29 -31) websites scored the highest while hospital/healthcare organization (16, 14v21) websites scored the lowest. Overall readability was low with a median Flesch-Kincaid Grade Level Score of 10.7 (IQR, 10 -12). Using this index, only one website (1.6%) was written below the recommended 6th grade reading level. CONCLUSION: Freely available online patient education materials for peripheral artery disease are poor, have varying quality, and are largely written at a level higher than that of an average US adult thus depriving the patient from understanding the existing information. We recommend that the vascular surgery community re-examine the current offering and provide improved readable websites to patients to facilitate patient education and shared decision making.


Assuntos
Compreensão , Doença Arterial Periférica , Adulto , Humanos , Internet , Doença Arterial Periférica/diagnóstico , Doença Arterial Periférica/terapia , Ferramenta de Busca , Sociedades Médicas , Resultado do Tratamento
16.
J Trauma Acute Care Surg ; 92(1): 232-238, 2022 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-34538830

RESUMO

BACKGROUND: The use of temporary intravascular shunts (TIVS) in the setting of military and civilian trauma has grown in recent years, predominantly because of the mounting evidence of improved limb outcomes. We sought to characterize the use and outcomes of TIVS in trauma through a systematic review of military and civilian literature. METHODS: The MEDLINE, EBSCO, EMBASE, and Cochrane databases were searched for studies on TIVS use in military and civilian trauma settings published between January 2000 and March 2021. Reports lacking systematic data collection along with those with insufficient TIVS descriptive and outcome data were excluded. Data regarding the characteristics and outcomes of TIVS were assessed and collective syntheses of military and civilian data performed. RESULTS: Twenty-one reports were included, 14 from civilian trauma centers or databases and 7 from military field data or databases (total of 1,380 shunts in 1,280 patients). Sixteen were retrospective cohort studies, and four were prospective. Five studies had an unshunted comparison group. Shunts were predominantly used in the lower extremity and most commonly for damage control indications. Dwell times were infrequently reported and were not consistently linked to shunt thrombosis or other complications. Anticoagulation during shunting was sparsely reported and inconsistently applied. Shunted limbs had higher injury severity than unshunted limbs but similar salvage rates. CONCLUSION: Temporary intravascular shunts are effective for expeditious restoration of perfusion in severely injured limbs and likely contribute to limb salvage. There is a paucity of comparative TIVS data in the literature and no consistently applied reporting standards, so controversies regarding TIVS use remain. LEVEL OF EVIDENCE: Systematic Review, level IV.


Assuntos
Extremidades , Salvamento de Membro/métodos , Enxerto Vascular , Lesões do Sistema Vascular , Ferimentos e Lesões , Extremidades/irrigação sanguínea , Extremidades/lesões , Humanos , Saúde Militar/estatística & dados numéricos , Avaliação de Resultados em Cuidados de Saúde , Centros de Traumatologia/estatística & dados numéricos , Enxerto Vascular/efeitos adversos , Enxerto Vascular/métodos , Enxerto Vascular/estatística & dados numéricos , Lesões do Sistema Vascular/etiologia , Lesões do Sistema Vascular/cirurgia , Ferimentos e Lesões/complicações , Ferimentos e Lesões/cirurgia
17.
J Trauma Acute Care Surg ; 92(4): 723-728, 2022 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-34789696

RESUMO

BACKGROUND: Resuscitative endovascular balloon occlusion of the aorta (REBOA) is increasingly used in some trauma settings. Arterial access-related limb ischemic complications (ARLICs) resulting from the femoral arterial access required for REBOA are largely under reported. We sought to describe the incidence of these complications and the clinical, technical, and device factors associated with their development. METHODS: This was a retrospective cohort study of records of adult trauma patients from the American Association for the Surgery of Trauma Aortic Occlusion for Resuscitation in Trauma and Acute care surgery registry between October 2013 and September 2020 who had REBOA and survived at least 48 hours. The primary outcome was ARLIC, defined as clinically relevant extremity ischemia or distal embolization. Relevant factors associated with ARLIC were also analyzed. RESULTS: Of 418 identified patients, 36 (8.6%) sustained at least one ARLIC; 22 with extremity ischemia, 25 with distal embolism, 11 with both. Patient demographics and injury characteristics were similar between ARLIC and no ARLIC groups. Access-related limb ischemic complication was associated with larger profile devices (p = 0.009), cutdown access technique (p = 0.02), and the presence of a pelvic external fixator/binder (p = 0.01). Patients with ARLIC had higher base deficit (p = 0.03) and lactate (p = 0.006). One hundred fifty-six patients received tranexamic acid (TXA), with 22 (14%) ARLICs. The rate of TXA use among ARLIC patients was 61% (vs. 35% TXA for non-ARLIC patients, p = 0.002). Access-related limb ischemic complication did not result in additional in-hospital mortality, however, ARLIC had prolonged hospital LOS (31 vs. 24 days, p = 0.02). Five ARLIC required surgical intervention, three patch angioplasty (and two with associated bypass), and four ARLIC limbs were amputated. CONCLUSION: Femoral artery REBOA access carries a risk of ARLIC, which is associated with unstable pelvis fractures, severe shock, and strongly with the administration of TXA. Use of lower-profile devices and close surveillance for these complications is warranted in these settings and caution should be exercised when using TXA in conjunction with REBOA. LEVEL OF EVIDENCE: Prognostic and Epidemiologic, Level III.


Assuntos
Oclusão com Balão , Procedimentos Endovasculares , Adulto , Aorta , Oclusão com Balão/efeitos adversos , Oclusão com Balão/métodos , Procedimentos Endovasculares/métodos , Humanos , Isquemia/etiologia , Extremidade Inferior , Estudos Retrospectivos , Sobreviventes , Estados Unidos/epidemiologia
18.
J Trauma Acute Care Surg ; 92(2): 407-412, 2022 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-34789705

RESUMO

BACKGROUND: The ideal conduit for traumatic arterial repair is controversial. Autologous vein was compared with synthetic interposition grafts in the acute setting. The primary outcome was in-hospital reoperation or endovascular intervention. METHODS: The American Association for the Surgery of Trauma PROspective Observational Vascular Injury Treatment registry from November 2013 to January 2019 was queried for arterial injuries requiring interposition vein or graft repair. Patients with no recorded Injury Severity Score were excluded, and multiple imputation was used for other missing data. Patients treated with synthetic grafts (SGs) were propensity matched to patients with vein grafts (VGs) to account for preoperative differences. RESULTS: Four hundred sixty from 19 institutions were identified, with 402 undergoing VG and 58 SG. In the SG group, 45 were PTFE grafts, 5 were Dacron, and 8 had other conduits. The SG group was more severely injured at admission with more gunshot wounds and higher mean Injury Severity Score, lactate, and first-24-hour transfusion requirement. In addition, the SG cohort had significantly lower admission systolic blood pressure, pH, and hemoglobin. After propensity matching, 51 patients with SG were matched with 87 patients with VG. There were no differences in demographics, clinical parameters, or diagnostic evaluation techniques postmatch. The need for reoperation or endovascular intervention between the matched groups was equivalent (18%; p = 0.8). There was no difference in any secondary outcome including thrombosis, stenosis, pseudoaneurysm, infection, or embolic event, and hospital and intensive care unit length of stay were the same. CONCLUSION: American Association for the Surgery of Trauma PROspective Observational Vascular Injury Treatment registry data demonstrate that SGs are used in more critically ill patients. After controlling for relevant clinical factors and propensity matching, there is no in-hospital difference in rate of reoperation or endovascular intervention, or any secondary outcome between VG and SG. LEVEL OF EVIDENCE: Prognostic and Epidemiolgic, Level III.


Assuntos
Artérias/lesões , Implante de Prótese Vascular/métodos , Prótese Vascular , Lesões do Sistema Vascular/cirurgia , Veias/transplante , Adulto , Feminino , Humanos , Escala de Gravidade do Ferimento , Masculino , Pontuação de Propensão , Sistema de Registros , Transplante Autólogo , Estados Unidos
19.
Front Vet Sci ; 9: 1069420, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36619944

RESUMO

Introduction: New low-cost technologies are needed to salvage lost blood in low-resource settings and large animal laboratories. The Hemafuse device is a simple mechanical device that can recover lost blood during surgery. The aim of this study is to assess the feasibility of this device for resuscitating large animals with controlled and unintended hemorrhage and to provide device considerations for use in this context. Methods: This study had two experimental components: (1) the Hemafuse device was kept on-shelf and used as needed to assess real-world use for unintended hemorrhage during experiments, and (2) animals underwent a controlled hemorrhage protocol, where four anesthetized swine underwent aortic and external jugular vein catheterization for pressure monitoring. Animals were hemorrhaged into the pelvis, and the Hemafuse device was used to suction the blood through a filter and pushed into a heparinized bag for subsequent retransfusion. Blood samples were collected at baseline, hemorrhage, within the device, and post-retransfusion and laboratory tests were performed. Results: Animals that underwent controlled hemorrhage had a baseline mean arterial pressure of 83.6 ± 7.8 mmHg, and central venous pressure of 12.8 ± 1.9 mmHg, with expected changes throughout hemorrhage and resuscitation. Following resuscitation, pH was similar to baseline (7.39 ± 0.05 vs. 7.31 ± 0.03, p = 0.24). Lactate increased throughout the experiment with no significant differences after autotransfusion compared to baseline (2.7 ± 0.7 vs. 4.1 ± 1.4 mmol/L, p = 0.37). There were no significant changes in metabolic physiology. Compared to baseline, the hemoglobin (7.8 ± 2.4 vs. 7.3 ± 1.8 g/dL, p = 0.74), hematocrit (23% ± 6.9 vs. 21.3% ± 5.6, p = 0.71), and activated clotting time (268.5 ± 44.5 vs. 193 ± 24.6 s, p = 0.35) were similar after retransfusion. When used for unintended hemorrhage, the animals were resuscitated using the device with a mean time to retransfusion time of 128.7 ± 13.3 s and 100% survival throughout the experiment. Conclusion: The Hemafuse device is feasible and efficacious for supporting large animal resuscitation. This is preliminary evidence that the device is a low-risk and low-cost off-the-shelf option for resuscitation using autologous blood with no significant effect on physiology post-retransfusion. We recommend that research laboratories consider the Hemafuse device for emergency use, particularly for highly invasive surgical laboratories where banked blood is not readily available.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA