Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Bone Joint Res ; 10(7): 425-436, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34269599

RESUMO

AIMS: This study aims to enhance understanding of clinical and radiological consequences and involved mechanisms that led to corrosion of the Precice Stryde (Stryde) intramedullary lengthening nail in the post market surveillance era of the device. Between 2018 and 2021 more than 2,000 Stryde nails have been implanted worldwide. However, the outcome of treatment with the Stryde system is insufficiently reported. METHODS: This is a retrospective single-centre study analyzing outcome of 57 consecutive lengthening procedures performed with the Stryde nail at the authors' institution from February 2019 until November 2020. Macro- and microscopic metallographic analysis of four retrieved nails was conducted. To investigate observed corrosion at telescoping junction, scanning electron microscopy (SEM) and energy dispersive x-ray spectroscopy (EDX) were performed. RESULTS: Adjacent to the nail's telescoping junction, osteolytic changes were observed in bi-planar radiographs of 20/57 segments (35%) after a mean of 9.5 months (95% confidence interval 7.2 to 11.9) after surgery. A total of 8/20 patients with osseous alterations (40%) reported rest and ambulation pain of the lengthened segment during consolidation. So far, 24 Stryde nails were retrieved and in 20 (83%) macroscopic corrosion was observed at the nail's telescoping junction. Before implant removal 11/20 radiographs (55%) of lengthened segments with these 20 nails revealed osteolysis. Implant retrieval analysis by means of SEM showed pitting and crevice corrosion. EDX detected chromium as the main metallic element of corrosion. CONCLUSION: Patients are exposed to the risk of implant-related osteolysis of unclear short- and long-term clinical consequences. The authors advocate in favour of an early implant removal after osseous consolidation. Cite this article: Bone Joint Res 2021;10(7):425-436.

2.
J Pediatr Orthop ; 31(4): 393-401, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21572277

RESUMO

BACKGROUND: In patients with multiple cartilaginous exostosis, distal ulnar osteochondromas frequently cause forearm deformities, with relative ulnar shortening, wrist joint deviation, and varus bowing. Progressive deformation often leads to pain, functional impairment, and cosmetic problems. Surgical ulnar lengthening is necessary to restore the carpal balance. The results of fixator-controlled ulnar lengthening were investigated in this study, using appropriate clinical and radiologic parameters and focusing on medium-term functional and structural outcomes. METHODS: Twelve children (3 boys, 9 girls; mean age 9.8 y) with multiple cartilaginous exostosis-induced ulnar shortening treated with fixator-controlled ulnar callotasis were evaluated retrospectively based on clinical and radiographic examinations preoperatively, after fixator removal, and at a follow-up investigation. Subjective symptoms and objective joint function were assessed clinically, whereas the extent of ulnar shortening, radial articular angle, carpal slip, and radial head dislocation were determined radiographically. RESULTS: The average follow-up period was 24.6 months. The mean ulnar shortening and radial articular angle improved significantly, from 14.3 mm or 38.7 degrees preoperatively to 1.7 mm or 25.6 degrees after fixator removal and showed a slight but significant increase to 5.2 mm or 30.1 degrees at the follow-up. Carpal slip and radial head dislocation remained unchanged. With the exception of radial abduction, no notable functional advancement was observed. One unintended ulnar overlengthening with a subsequent ulnocarpal impaction syndrome, one premature callus consolidation, and two fixator dislocations were noted. CONCLUSIONS: In agreement with literature reports, carpal balance can be restored over the medium term. However, mild recurrences of ulnar shortening and radial malformation were observed during further development. To prevent deformity progression in immature patients, surgery should be carried out early. The optimal timing of surgery needs to be calculated precisely to take advantage of the high remodeling potential and an acceptable degree of recurrent deformity. Ulnar lengthening is necessary, but overcorrection is inadvisable due to possible ulnocarpal impaction syndrome. As significant remodeling effects on the radius were observed, simultaneous radial correction procedures are not recommended a priori.


Assuntos
Exostose Múltipla Hereditária/cirurgia , Antebraço/cirurgia , Osteogênese por Distração/métodos , Ulna/cirurgia , Adolescente , Criança , Pré-Escolar , Exostose Múltipla Hereditária/complicações , Exostose Múltipla Hereditária/diagnóstico por imagem , Feminino , Seguimentos , Antebraço/anormalidades , Antebraço/diagnóstico por imagem , Humanos , Masculino , Radiografia , Rádio (Anatomia)/diagnóstico por imagem , Rádio (Anatomia)/patologia , Estudos Retrospectivos , Ulna/anormalidades , Ulna/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA