Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Int J Cardiol ; 363: 80-86, 2022 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-35764203

RESUMO

BACKGROUND: Atrioventricular node ablation (AVNA) and pacemaker (PM) is performed in symptomatic atrial fibrillation (AF) unresponsive to medical treatment and percutaneous ablation. This meta-analysis evaluated results after AVNA and PM. METHODS: Primary and secondary endpoints were early/late overall/cardiac-related mortality and early/late postoperative complications. Meta-regression explored mortality and preoperative characteristics relation. RESULTS: We selected 93 studies with 11,340 patients: 9105 right ventricular (RV)-PM, and 2235 biventricular PM (cardiac resynchronization therapy, CRT). Malignant arrhythmia (2.5%), heart failure (2.4%), and lead dislodgement (2.0%) were most common periprocedural complications. Pooled estimated 30-day mortality was 1.08% (95%CI:0.65-1.77). At 19.9 months median follow-up (IQR: 10.3-34 months), rehospitalization (0.79%/month) and heart failure (0.48%/month) were the most frequent complications. Overall mortality incidence rate (IR) was 0.43%/month (95%CI:0.36-0.51), and cardiac death IR 0.27%/month (95%CI:0.22-0.32). No mortality determinants emerged in the AVNA CRT subgroup. AVNA RV-PM subgroup univariable meta-regression showed inverse relationship between age, ejection fraction (EF), and late cardiac death (Beta = -0.0709 ± 0.0272; p = 0.0092 and Beta = -0.0833 ± 0.0249; p = 0.0008). Coronary artery disease (CAD) was directly associated to follow-up overall/cardiac mortality at univariable (Beta = 0.0550 ± 0.0136, p < 0.0001; Beta = 0.0540 ± 0.0130, p < 0.0001) and multivariable (Beta = 0.0460 ± 0.0189, p = 0.152; Beta = 0.0378 ± 0.0192, p = 0.0491) meta-regression. CONCLUSIONS: Solid long-term evidence supporting AVNA and pace is lacking. Younger patients with reduced LVEF% have increased follow-up cardiac mortality after AVNA RV and may require CRT. Alternative strategies to maintain sinus rhythm and ventricular synchronism should be compared to AVNA to support future treatment strategies.


Assuntos
Fibrilação Atrial , Terapia de Ressincronização Cardíaca , Ablação por Cateter , Insuficiência Cardíaca , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Nó Atrioventricular/cirurgia , Terapia de Ressincronização Cardíaca/métodos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Morte , Humanos , Taquicardia , Resultado do Tratamento
2.
Eur J Cardiothorac Surg ; 59(3): 674-679, 2021 04 13.
Artigo em Inglês | MEDLINE | ID: mdl-33236049

RESUMO

OBJECTIVES: The Florida-sleeve is a valve-sparing technique that causes minimal interference to leaflet kinematics and aortic root dynamism. The aim of this in vitro study was to evaluate the effects of the Florida-sleeve and Yacoub techniques on aortic leaflet kinematics. METHODS: Two groups of 6 whole porcine hearts were treated with either the Florida-sleeve technique or the Yacoub technique and tested in a pulsatile loop. Valve fluid dynamics, coronary flow analysis and valve echocardiograms were performed both before and after the procedures. RESULTS: Both procedures showed no difference in rapid valve opening time as compared with their respective baseline values. The Florida-sleeve procedure showed a shorter slow closing time (192 ± 19 ms vs baseline 244 ± 14 ms, P = 0.016) and increased slow closing velocity (-1.5 ± 0.4 cm/s vs baseline -0.8 ± 0.4 cm/s, P = 0.038). In the rapid valve closing phase, the Yacoub procedure showed a trend towards slower closing valve velocity (-16 ± 9 cm/s vs baseline -25 ± 9 cm/s, P = 0.07). The Yacoub procedure showed larger leaflet displacement at the end of the slow valve closing time that was 2.0 ± 0.5 cm vs baseline 1.5 ± 0.3 cm, P = 0.044. When comparing the Florida-sleeve and Yacoub procedures, the former showed statistically significant shorter slow valve closing time (P = 0.017). CONCLUSIONS: This study showed that the Florida-sleeve technique alters the slow closing phase of the aortic valve leaflet kinematics when compared with both the normal baseline and Yacoub procedure, while the latter showed a larger leaflet displacement before the rapid closing valve phase.


Assuntos
Insuficiência da Valva Aórtica , Próteses Valvulares Cardíacas , Animais , Aorta , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Fenômenos Biomecânicos , Florida , Suínos
3.
J Cardiovasc Surg (Torino) ; 61(2): 250-255, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31985188

RESUMO

BACKGROUND: Patients with aortic root ectasia and bicuspid aortic valve benefit of the treatment with aortic valve sparing procedure, with excellent long-term results. The Sleeve-procedure is one of the options in patients with aortic root diseases and it might be suitable for patients with a bicuspid valve. METHODS: From October 2006 to December 2018, 42 consecutive patients with bicuspid aortic valve and aortic root ectasia/aneurysm, with or without aortic regurgitation, were surgically treated with the Sleeve-procedure. RESULTS: In 20 patients (48%) leaflets surgery was necessary and consisted of raphe mobilization/resection in 17 patients, plication of both leaflets in 2 patients and a two-commissures resuspension in 1 patient. During a mean clinical follow-up time of 4.4±3.1 years, the survival rate was 100%, 1 patient required a reoperation at 6.1 years postoperatively, with an overall freedom from reoperation of 94±5%. The rest of the patients (41/42), had no more than mild residual aortic valve regurgitation. With a mean follow-up of 4.3±1.7 years the magnetic resonance imaging performed in 26 patients, did not show signs of aortic wall herniation through the key-holes or persisting creases of the aortic wall inside the prosthesis. CONCLUSIONS: Patients with aortic root disease and bicuspid aortic valve may be treated with Sleeve technique with excellent midterm results. However, a longer follow-up is required before drawing any solid conclusion.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Valva Aórtica/anormalidades , Procedimentos Cirúrgicos Cardíacos/métodos , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Monitorização Fisiológica/métodos , Adulto , Aneurisma da Aorta Torácica/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/mortalidade , Doença da Válvula Aórtica Bicúspide , Procedimentos Cirúrgicos Cardíacos/mortalidade , Estudos de Coortes , Feminino , Seguimentos , Doenças das Valvas Cardíacas/diagnóstico por imagem , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Imagem Cinética por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Tratamentos com Preservação do Órgão , Estudos Retrospectivos , Medição de Risco , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
4.
J Card Surg ; 32(11): 680-685, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29119598

RESUMO

BACKGROUND: Stentless valves have long been considered the ideal valves in terms of hemodynamics. Recently, the Trifecta valve, a stented bioprosthesis with excellent fluid dynamic characteristics, has become available. The aim of the study was to compare the opening/closing pattern of the Freestyle stentless valve and the Trifecta valve with that of the native aortic valve. METHODS: A total of 12 patients with a Freestyle and 10 with a Trifecta valve were compared to normal native aortic valves in 12 control patients. Leaflet kinematics and hemodynamic parameters were obtained by echocardiographic M-mode and Doppler measurements. RESULTS: The control group displayed significantly longer Rapid Valve Opening Time (45 ± 7 ms) and Rapid Valve Closing Time (42 ± 9 ms) than Freestyle patients (Rapid Valve Opening Time: 32 ± 7 ms; Rapid Valve Closing Time: 31 ± 8 ms) and Trifecta patients (Rapid Valve Opening Time: 31 ± 7 ms; Rapid Valve Closing Time: 30 ± 8 ms) (P < 0.0001). The maximal leaflet displacement reached at the end of rapid valve opening was 16.7 ± 3.2 mm, 17.7 ± 2.3 mm, and 17.7 ± 5.3 mm (P = 0.42) in the Freestyle, Trifecta, and control groups, respectively. The total opening time was shorter in the control group (223 ± 25 ms) than in Freestyle (319 ± 61 ms) and Trifecta (324 ± 46 ms) patients (P < 0.0001). CONCLUSIONS: The Freestyle stentless valve was not superior to the Trifecta valve in terms of kinematics and functions more like a stented bioprosthesis.


Assuntos
Valva Aórtica/fisiologia , Valva Aórtica/cirurgia , Bioprótese , Próteses Valvulares Cardíacas , Stents , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Fenômenos Biomecânicos , Ecocardiografia Doppler , Feminino , Implante de Prótese de Valva Cardíaca , Hemodinâmica , Humanos , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA