1.
Anticancer Res ; 44(4): 1583-1589, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38537975

RESUMO

BACKGROUND/AIM: Concurrent cisplatin-based chemoradiotherapy (CCRT) is the standard treatment for locally advanced cervical cancer. Especially, CCRT with magnetic resonance imaging (MRI) or computed tomography-based image-guided brachytherapy (CT-based 3D-IGBT) for cervical cancer has resulted in good LC rates. However, progression-free survival (PFS) and overall survival (OS) rates for locally advanced cervical cancer are still low and could be improved. The aim of the study was to evaluate treatment efficacy and late toxicity of external beam radiotherapy (EBRT) and CT-based IGBT with or without concurrent chemotherapy in patients with squamous cell carcinoma of the uterine cervix and investigate patterns of failure. PATIENTS AND METHODS: We retrospectively analyzed clinical data of cervical squamous cell carcinoma patients treated with definitive radiotherapy with or without concurrent chemotherapy at Saitama Medical University International Medical Center. Local control (LC), PFS, patterns of failure, and late toxicity were the evaluated outcomes. RESULTS: Overall, 290 patients were enrolled in the study. Median follow-up was 51.5 months. During follow-up, 74 patients developed recurrence: 10 patients with intra-pelvic failure only, 45 with extra-pelvic failure only, and 19 with both. The 3-year LC was 100% for T1b-T2a, 96.8% for T2b, 89.5% for T3b, and 88.5% for T4 disease. The 3-year PFS was 100% for stage IB-IIA, 89.0% for stage IIB, 70.7% for stage IIIB, 72.6% for stage IIIC1r, and 40.1% for stage IVA. The incidence of grade 3-4 gastrointestinal and genitourinary toxicities was 3.0% and 1.7%, respectively. CONCLUSION: Combination of EBRT and CT-based IGBT with or without concurrent chemotherapy produced favorable LC with acceptable rates of late toxicities. However, extra-pelvic failures frequently occurred and PFS was less satisfactory in patients with stage III-IVA disease, which indicated the need for additional treatment in these patients.


Assuntos
Braquiterapia , Carcinoma de Células Escamosas , Neoplasias do Colo do Útero , Feminino , Humanos , Carcinoma de Células Escamosas/terapia , Carcinoma de Células Escamosas/tratamento farmacológico , Neoplasias do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/radioterapia , Braquiterapia/métodos , Estudos Retrospectivos , Cisplatino/uso terapêutico , Resultado do Tratamento , Quimiorradioterapia/efeitos adversos , Tomografia Computadorizada por Raios X/métodos , Tomografia , Estadiamento de Neoplasias
2.
Pacing Clin Electrophysiol ; 45(3): 297-301, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35172014

RESUMO

BACKGROUND: The displacement of cardiac implantable electronic devices (CIEDs) toward the caudal side during standing after CIED implantation could cause lead dislodgement. This study investigated the relationship between supine pocket position and standing CIEDs' displacement distance after the implantation. METHODS: After CIED surgeries performed at 2 hospitals between 2012 and 2020, 134 patients underwent postoperative chest x-rays in the supine and standing positions during hospitalization. To measure the displacement distance of CIEDs from the supine to the standing position, we identified the first thoracic vertebrae (Th1) in the supine position using the first rib as an index, drew a horizontal line at the lower edge of the Th1, and calculated the distance from that point to the upper edge of the CIED. The difference between measures for the two positions was compared. At the position of the pocket in the thorax in the supine position, the ratio of the distance between the thorax and the device is defined as the device thorax ratio (DTR). We examined the relationship between DTR and CIED displacement distance. RESULTS: In this study, we included 134 patients (53% men; median age, 79 years, body mass index, 22.3 ± 3.4; pacemaker 93%, left implantation 96%). We found that the more lateral the position of the CIED pocket, the more the CIED fell when standing (confidence interval = 0.34-0.60, P < .001). CONCLUSIONS: The farther the CIED was implanted outside the thorax in the supine position, the more significantly the CIED was displaced in the standing position.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Idoso , Feminino , Humanos , Masculino , Estudos Retrospectivos , Posição Ortostática , Tórax
3.
J Cardiovasc Electrophysiol ; 32(11): 3103-3106, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34460986

RESUMO

Adenosine can hyperpolarize the atrial action potential, which helps rapidly re-establish the membrane potential in ablated sites and unmask "dormant conduction." It has been reported that pharmacological agents, including adenosine, were unable to revive traumatized tissues. We present the first case of the catheter-induced mechanical block ("bump" phenomenon) that was unmasked with adenosine administration in the working myocardium of the superior vena cava. This result may be because, unlike before, we could determine the force of contact between the tip of the ablation catheter and the myocardial tissue. This case suggests the clinical usefulness of adenosine for unmasking bumped sites.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Adenosina , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Catéteres , Humanos , Veias Pulmonares/cirurgia , Resultado do Tratamento , Veia Cava Superior
4.
J Cardiovasc Electrophysiol ; 31(10): 2765-2769, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32757423

RESUMO

An 82-year-old woman received pacemaker implantation for sick sinus syndrome. Two days after the implantation, electrocardiography showed 2:1 atrial pacing failure, followed by a bradycardia-dependent increase in the atrial pacing threshold during a pacemaker examination. However, transient 1:1 atrial pacing capture recovered by adenosine triphosphate (ATP) administration, which was performed to evaluate the bradycardia-dependent pacing failure mechanism. We considered this phenomenon to be caused by Phase 4 depolarization and avoided replacing this atrial lead. Three weeks later, the atrial pacing threshold had improved. We report the potential role of Phase 4 depolarization in a bradycardia-dependent increase in pacing threshold by using ATP.


Assuntos
Fibrilação Atrial , Marca-Passo Artificial , Adenosina , Idoso de 80 Anos ou mais , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Bradicardia/induzido quimicamente , Bradicardia/diagnóstico , Bradicardia/terapia , Estimulação Cardíaca Artificial/efeitos adversos , Eletrocardiografia , Feminino , Humanos , Marca-Passo Artificial/efeitos adversos , Síndrome do Nó Sinusal/diagnóstico , Síndrome do Nó Sinusal/terapia
5.
J Cardiovasc Electrophysiol ; 30(12): 2944-2949, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31588621

RESUMO

INTRODUCTION: One cause of cerebral infarction during cryoballoon ablation is the entry of air into a sheath due to the use of inappropriate catheters. It is known that the left atrial pressure of patients with obstructive sleep apnea syndrome can be negative. However, the effects of catheter selection and negative pressure changes in the sheath on air intrusion are not yet well understood. The aim of this study was to evaluate how catheter selection and negative pressure changes affect air intrusion and to perform countermeasures for air intrusion. METHODS AND RESULTS: This experiment used siphon principle to create negative pressure in the sheath. Noncryoablation catheters (not designed exclusively for cryoballoon ablation) and cryoballoon catheters were investigated. Catheters were inserted into the sheath and then removed. Thereafter, the amount of air in the sheath was measured. For catheters producing significantly larger amounts of air intrusion, the catheters were inserted via a long sheath in the sheath (sheath-in-sheath technique) and the same procedures were repeated. We found that the amount of air intrusion through most of the noncryoablation catheters was significantly larger than that through cryoablation catheters. An increase in the magnitude of negative pressure in the sheath resulted in a proportional increase in air intrusion, but the sheath-in-sheath technique significantly reduced air intrusion. CONCLUSION: The amount of air intrusion increased when using catheters with complicated tip shapes and thin outer diameters and when the magnitude of negative pressure in the sheath increased. The sheath-in-sheath technique may be an effective countermeasure.


Assuntos
Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Criocirurgia/instrumentação , Embolia/prevenção & controle , Função do Átrio Esquerdo , Pressão Atrial , Cateterismo Cardíaco/efeitos adversos , Criocirurgia/efeitos adversos , Embolia/etiologia , Embolia/fisiopatologia , Desenho de Equipamento , Humanos , Teste de Materiais , Fatores de Risco