Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Kyobu Geka ; 77(3): 210-212, 2024 Mar.
Artigo em Japonês | MEDLINE | ID: mdl-38465493

RESUMO

The patient is a 56-year-old man. He fell while playing golf and sustained a contusion on his right chest. He fell into hemorrhagic shock during surgery for a right clavicle fracture at a nearby hospital and required cardiac resuscitation. Computed tomography( CT) scan revealed left pneumothorax and right hemothorax, and a contrast-enhanced CT scan revealed a pseudoaneurysm at the brachiocephalic artery origin. He underwent surgery three weeks later. Surgery was performed through a median sternotomy and partial arch replacement (zone 2) with antegrade cerebral perfusion under moderate hypothermia. He was discharged on postoperative day 10 without significant complications.


Assuntos
Falso Aneurisma , Fraturas Ósseas , Masculino , Humanos , Pessoa de Meia-Idade , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/etiologia , Falso Aneurisma/cirurgia , Tomografia Computadorizada por Raios X , Fraturas Ósseas/complicações , Tronco Braquiocefálico/diagnóstico por imagem , Tronco Braquiocefálico/cirurgia , Perfusão
2.
Ann Thorac Surg ; 117(1): 78-85, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37541561

RESUMO

BACKGROUND: Long-term results of valve-sparing aortic root replacement (VSRR) and aortic cusp repair for aortic regurgitation are unclear. METHODS: VSRR by reimplantation was performed in 363 patients. Tricuspid aortic valve (TAV) and bicuspid aortic valve were found in 285 and 71 patients, respectively. RESULTS: Aortic cusp repair was performed in 268 patients. Of patients with TAV 129 had central plication of the Arantius node, 36 had free margin resuspension, and 71 had reinforcement. Mean follow-up was 71.4 months. Among TAV patients freedom from aortic valve reoperation at 10 and 15 years was 85.1% and 78.3%, respectively. Freedom from aortic valve reoperation at 10 years was lower in patients with cusp prolapse than without (77.4% vs 93.2%, P = .007). The overall freedom from more than mild aortic regurgitation at 10 and 15 years was 72.4% and 64.0%, respectively. It was also significantly greater in patients without cusp prolapse (78.4% vs 67.7%, P = .02). As for the cusp repair technique the freedom from aortic valve reoperation at 10 years was significantly better in patients who underwent only resuspension or reinforcement techniques compared with patients who underwent only central plication technique (100% vs 72.8%, P = .008). CONCLUSIONS: Long-term results of VSRR with aortic cusp repair were satisfactory. The resuspension technique appears to be useful for repairing aortic cusp prolapse in patients with TAV.


Assuntos
Insuficiência da Valva Aórtica , Valva Aórtica , Humanos , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Aorta/cirurgia , Reoperação , Reimplante , Prolapso , Resultado do Tratamento , Estudos Retrospectivos
3.
Gen Thorac Cardiovasc Surg ; 67(2): 263-265, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29455309

RESUMO

We report a rare case of right heart failure caused by distal aortic aneurysm. Although aortopulmonary fistula is a common complication of giant aortic arch aneurysm, right heart failure caused by mechanical pressure by aneurysm is very rare. A 79-year-old female patient presented dyspnea. Contrast computed tomography (CT) of the thorax delineated a 78 mm aortic arch aneurysm pressing the main to left pulmonary artery and a 40 mm pericardial effusion at maximum depth at posterior side. Echocardiography showed the acceleration flow from main to left pulmonary artery and moderate pulmonary hypertension. Left ventricular function, however, was preserved. We diagnosed right heart failure caused by giant aortic arch aneurysm and performed emergency aortic arch aneurysm replacement. After the operation, pulmonary artery pressure decreased and right heart failure improved.


Assuntos
Aneurisma da Aorta Torácica/complicações , Insuficiência Cardíaca/etiologia , Artéria Pulmonar/fisiopatologia , Idoso , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/fisiopatologia , Aneurisma da Aorta Torácica/cirurgia , Ruptura Aórtica/cirurgia , Dispneia/diagnóstico , Ecocardiografia , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Humanos , Derrame Pericárdico/etiologia , Tomografia Computadorizada por Raios X , Procedimentos Cirúrgicos Vasculares
4.
Kyobu Geka ; 69(10): 833-7, 2016 Sep.
Artigo em Japonês | MEDLINE | ID: mdl-27586313

RESUMO

A 77-year-old man with a history of stent implantation in the right common iliac artery(CIA) and the left external iliac artery(EIA) was admitted to our hospital for a rapid growth of an aneurysm( max 53 mm) at Th11 level of the descending aorta. Although thoracic endovascular aortic repair (TEVAR) was required, there were many problems about access rout. The infrarenal abdominal aorta and the left EIA were severely calcified, and the lumens of the right CIA stent(5.3 mm) and the left EIA stent( 4.3 mm) were small in size. Besides, the left CIA was short(13 mm). Therefore, TEVAR was performed by retrograde approach from the left internal iliac artery( IIA) with a tube graft conduit in the hybrid operation room. IIA is a useful option for an access rout in endovascular aortic repair.


Assuntos
Aorta Abdominal/cirurgia , Artéria Ilíaca/cirurgia , Idoso , Aorta Abdominal/diagnóstico por imagem , Humanos , Artéria Ilíaca/diagnóstico por imagem , Imageamento Tridimensional , Masculino , Stents , Tomografia Computadorizada por Raios X
5.
Kyobu Geka ; 68(7): 515-9, 2015 Jul.
Artigo em Japonês | MEDLINE | ID: mdl-26197826

RESUMO

A 74-year-old woman progressed to extensive aortic aneurysm after 2 years and 6 months from onset of type B dissection. A computed tomography scan revealed aortic aneurysm from ascending aorta to Th12 level of descending aorta. Her appearance was very frailty. Therefore, we performed 2-staged hybrid repair for this case. First, surgical total arch replacement with elephant trunk via median sternotomy was performed. On the 47th days after the 1st operation, thoracic endovascular aortic repair was performed. The spinal drainage was done for spinal cord protection. Postoperative course was uneventful without any complications. Considering a surgical stress, 2-staged hybrid repair using a stent graft was less-invasive than 1 staged graft replacement.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Aneurisma Aórtico/cirurgia , Idoso , Drenagem , Feminino , Humanos , Procedimentos Cirúrgicos Torácicos , Tomografia Computadorizada por Raios X , Enxerto Vascular , Cicatrização
6.
Kyobu Geka ; 68(7): 532-4, 2015 Jul.
Artigo em Japonês | MEDLINE | ID: mdl-26197830

RESUMO

A 64-years-old man had cor triatriatum (Lucas-Schmidt type I A) with severe mitral regurgitation and atrial fibrillation. We perfomed resection of the anomalous septum between the accessory chamber and left atrium, and conducted mitral annuloplasty and maze procedure. Arrhythmia were not encountered after surgery. The maze procedure and resection of the anomalous septum with mitral surgery proved to be effective for atrial fibrillation with cor triatriatum.


Assuntos
Fibrilação Atrial/cirurgia , Coração Triatriado/cirurgia , Insuficiência da Valva Mitral/cirurgia , Fibrilação Atrial/complicações , Procedimentos Cirúrgicos Cardíacos , Coração Triatriado/complicações , Coração Triatriado/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/complicações , Tomografia Computadorizada por Raios X
7.
Circ J ; 68(1): 88-90, 2004 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-14695473

RESUMO

A 66-year-old man was found to have a mycotic aneurysm of the thoracic aorta. It was first suspected to be a pseudoaneurysm of the descending thoracic aorta on computed tomography scan, and the blood cultures were positive for methicillin-resistant Staphylococcus aureus (MRSA). It was subsequently diagnosed as a mycotic aneurysm, but because the patient continued to do so poorly with septicemia, conventional surgery (ie, aortic exclusion and extraanatomic bypass, or surgical placement of in situ graft) was not performed. A stent-graft device composed of several units of self-expandable Z stents covered with ultra-thin woven Dacron was inserted through 21F sheath via the left external iliac artery and aortography showed successful deployment without blood endoleaks. The procedure was completed without incident and the patient has continued to do well. Endovascular stent-grafts may offer significant advantages for patients at high surgical risk.


Assuntos
Aneurisma da Aorta Torácica/diagnóstico por imagem , Micoses/complicações , Stents , Idoso , Aneurisma da Aorta Torácica/microbiologia , Desenho de Equipamento , Humanos , Masculino , Radiografia Torácica , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA