Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Anal Bioanal Chem ; 406(26): 6723-33, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25168110

RESUMO

A new long-wavelength fluorescent probe, 1,7-dimethyl-3,5-distyryl-8-phenyl-(4'-iodoacetamido)difluoroboradiaza-s-indacene (DMDSPAB-I), was designed and synthesized for thiol labeling in high-performance liquid chromatography (HPLC). The excitation and emission wavelengths of DMDSPAB-I are 620 and 630 nm, respectively, with a high fluorescence quantum yield of 0.557, which is advantageous in preventing interference of intrinsic fluorescence from complex biological matrices and enabling high sensitivity HPLC. Based on DMDSPAB-I, a reversed-phase HPLC method was developed for measuring low-molecular-weight thiols including glutathione, cysteine, homocysteine, N-acetylcysteine, cysteinylglycine, and penicillamine. After the specific reaction of DMDSPAB-I with thiols, baseline separation of all six stable derivatives was achieved through isocratic elution on a C18 column within 25 min, with the limits of detection (signal-to-noise ratio = 3) from 0.24 nmol L(-1) for glutathione to 0.72 nmol L(-1) for penicillamine. The proposed method was validated in part by measuring thiols in blood samples from mice, with recoveries of 95.3-104.3%.


Assuntos
Compostos de Boro/química , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia de Fase Reversa/métodos , Corantes Fluorescentes/química , Iodoacetamida/análogos & derivados , Compostos de Sulfidrila/sangue , Acetilcisteína/sangue , Acetilcisteína/isolamento & purificação , Animais , Cisteína/sangue , Cisteína/isolamento & purificação , Dipeptídeos/sangue , Dipeptídeos/isolamento & purificação , Glutationa/sangue , Glutationa/isolamento & purificação , Homocisteína/sangue , Homocisteína/isolamento & purificação , Iodoacetamida/química , Limite de Detecção , Masculino , Camundongos , Penicilamina/sangue , Penicilamina/isolamento & purificação , Compostos de Sulfidrila/isolamento & purificação
2.
Electrophoresis ; 35(20): 2951-8, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25070266

RESUMO

A CZE with near-infrared (NIR) LIF detection method has been developed for the analysis of six low molecular weight thiols including glutathione, homocysteine, cysteine, γ-glutamylcysteine, cysteinylglycine, and N-acetylcysteine. For this purpose, a new NIR fluorescent probe, 1,7-dimethyl-3,5-distyryl-8-phenyl-(4'-iodoacetamido)difluoroboradiaza-s-indacene was utilized as the labeling reagent, whose excitation wavelength matches the commercially available NIR laser line of 635 nm. The optimum procedure included a derivatization step of the free thiols at 45°C for 25 min and CZE analysis conducted within 14 min in the running buffer containing 16 mmol/L pH 7.0 sodium citrate and 60% v/v ACN. The LODs (S/N = 3) ranged from 0.11 nmol/L for N-acetylcysteine to 0.31 nmol/L for γ-glutamylcysteine, which are better than or comparable to those reported with other derivatization-based CE-LIF methods. As the first trial of NIR CE-LIF method for thiol determination, the practical application of the proposed method has been validated by detecting thiols in cucumber and tomato samples with recoveries of 96.5-104.3%.


Assuntos
Compostos de Boro/química , Eletroforese Capilar/métodos , Corantes Fluorescentes/química , Espectrometria de Fluorescência/métodos , Compostos de Sulfidrila/análise , Aminoácidos Sulfúricos/análise , Aminoácidos Sulfúricos/química , Estabilidade de Medicamentos , Glutationa/análise , Glutationa/química , Limite de Detecção , Modelos Lineares , Reprodutibilidade dos Testes , Compostos de Sulfidrila/química
3.
J Chromatogr A ; 1359: 309-16, 2014 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-25069745

RESUMO

A simple, rapid and efficient method based on microchip electrophoresis coupled with fluorescence detection (MCE-FLD) was developed for simultaneous determination of nitric oxide (NO), glutathione (GSH) and cysteine (Cys) using dual labeling strategy. Two highly reactive fluorogenic probes, 1,3,5,7-tetramethyl-8-(3',4'-diaminophenyl)-difluoroboradiaza-s-indacene (DAMBO) and 1,3,5,7-tetramethyl-8-phenyl-(2-maleimide)-difluoroboradiaza-s-indacene (TMPAB-o-M), were used for labeling NO and thiols, respectively, under physiological conditions. The rapid separation and sensitive detection of the derivatives were achieved on a glass microchip within 70s in a running buffer of 20mM H3Cit-Na2HPO4 solution (pH 7.4) containing 15% (v/v) acetonitrile at a separation voltage of 2400V. The limits of detection (S/N=3) for NO, GSH and Cys were 7.0, 3.0 and 2.0nM, respectively. The proposed method was validated by measuring intracellular levels of NO and biothiols in macrophage RAW264.7 cells.


Assuntos
Cisteína/análise , Eletroforese em Microchip/métodos , Glutationa/análise , Macrófagos/química , Óxido Nítrico/análise , Animais , Linhagem Celular , Cisteína/metabolismo , Eletroforese em Microchip/instrumentação , Fluorescência , Glutationa/metabolismo , Concentração de Íons de Hidrogênio , Macrófagos/metabolismo , Camundongos , Óxido Nítrico/metabolismo
4.
Electrophoresis ; 35(8): 1188-95, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24482111

RESUMO

This paper, for the first time, reported the development of a simple, rapid, and reliable method for the separation and sensitive determination of four thiol compounds including homocysteine, cysteine, glutathione, and N-acetylcysteine based on glass MCE with fluorescence detection using a highly reactive fluorogenic probe, 1,3,5,7-tetramethyl-8-phenyl-(2-maleimide)-difluoroboradiaza-s-indacene (TMPAB-o-M), as the labeling reagent. TMPAB-o-M reacted selectively with thiols to produce highly fluorescent derivatives and the highest derivatization efficiency was achieved within 6 min in physiological conditions. After the optimization of separation conditions, a baseline separation of the four thiol compounds was achieved with the detection limits ranging from 2 nM for glutathione to 4 nM for cysteine (S/N = 3) and RSDs (n = 5) in the range of 3.2-3.8%. The proposed method was significantly sensitive compared to those using electrochemical or even LIF detection in MCE-based setup reported previously, and applied to the determination of intracellular thiols in macrophage RAW264.7 cells.


Assuntos
Acetilcisteína/análise , Cisteína/análise , Eletroforese em Microchip/métodos , Glutationa/análise , Macrófagos/química , Compostos de Sulfidrila/análise , Animais , Linhagem Celular , Cisteína/análogos & derivados , Fluorescência , Corantes Fluorescentes/química , Compostos Heterocíclicos com 3 Anéis/química , Limite de Detecção , Maleimidas/química , Camundongos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA