Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Diagnostics (Basel) ; 14(8)2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38667477

RESUMO

Pediatric sarcomas, rare malignancies of mesenchymal origin, pose diagnostic and therapeutic challenges. In this review, we explore the role of radiomics in reshaping our understanding of pediatric sarcomas, emphasizing methodological considerations and applications such as diagnostics and predictive modeling. A systematic review conducted up to November 2023 identified 72 papers on radiomics analysis in pediatric sarcoma from PubMed/MEDLINE, Web of Knowledge, and Scopus. Following inclusion and exclusion criteria, 10 reports were included in this review. The studies, predominantly retrospective, focus on Ewing sarcoma and osteosarcoma, utilizing diverse imaging modalities, including CT, MRI, PET/CT, and PET/MRI. Manual segmentation is common, with a median of 35 features extracted. Radiomics Quality Score (RQS) and Methodological Radiomics Score (METRICS) assessments reveal a consistent emphasis on non-radiomic features, validation criteria, and improved methodological rigor in recent publications. Diagnostic applications dominate, with innovative studies exploring prognostic and treatment response aspects. Challenges include feature heterogeneity and sample size variations. The evolving landscape underscores the need for standardized methodologies. Despite challenges, the diagnostic and predictive potential of radiomics in pediatric oncology is evident, paving the way for precision medicine advancements.

2.
Radiol Artif Intell ; 6(1): e220257, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38231039

RESUMO

Purpose To perform a systematic review and meta-analysis assessing the predictive accuracy of radiomics in the noninvasive determination of isocitrate dehydrogenase (IDH) status in grade 4 and lower-grade diffuse gliomas. Materials and Methods A systematic search was performed in the PubMed, Scopus, Embase, Web of Science, and Cochrane Library databases for relevant articles published between January 1, 2010, and July 7, 2021. Pooled sensitivity and specificity across studies were estimated. Risk of bias was evaluated using Quality Assessment of Diagnostic Accuracy Studies-2, and methods were evaluated using the radiomics quality score (RQS). Additional subgroup analyses were performed according to tumor grade, RQS, and number of sequences used (PROSPERO ID: CRD42021268958). Results Twenty-six studies that included 3280 patients were included for analysis. The pooled sensitivity and specificity of radiomics for the detection of IDH mutation were 79% (95% CI: 76, 83) and 80% (95% CI: 76, 83), respectively. Low RQS scores were found overall for the included works. Subgroup analyses showed lower false-positive rates in very low RQS studies (RQS < 6) (meta-regression, z = -1.9; P = .02) compared with adequate RQS studies. No substantial differences were found in pooled sensitivity and specificity for the pure grade 4 gliomas group compared with the all-grade gliomas group (81% and 86% vs 79% and 79%, respectively) and for studies using single versus multiple sequences (80% and 77% vs 79% and 82%, respectively). Conclusion The pooled data showed that radiomics achieved good accuracy performance in distinguishing IDH mutation status in patients with grade 4 and lower-grade diffuse gliomas. The overall methodologic quality (RQS) was low and introduced potential bias. Keywords: Neuro-Oncology, Radiomics, Integration, Application Domain, Glioblastoma, IDH Mutation, Radiomics Quality Scoring Supplemental material is available for this article. Published under a CC BY 4.0 license.


Assuntos
Glioblastoma , Glioma , Humanos , Isocitrato Desidrogenase/genética , Radiômica , Glioma/diagnóstico por imagem , Mutação
3.
Front Radiol ; 3: 1141499, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37492385

RESUMO

The aim of this systematic review was to evaluate the state of the art of radiomics in testicular imaging by assessing the quality of radiomic workflow using the Radiomics Quality Score (RQS) and the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2). A systematic literature search was performed to find potentially relevant articles on the applications of radiomics in testicular imaging, and 6 final articles were extracted. The mean RQS was 11,33 ± 3,88 resulting in a percentage of 31,48% ± 10,78%. Regarding QUADAS-2 criteria, no relevant biases were found in the included papers in the patient selection, index test, reference standard criteria and flow-and-timing domain. In conclusion, despite the publication of promising studies, radiomic research on testicular imaging is in its very beginning and still hindered by methodological limitations, and the potential applications of radiomics for this field are still largely unexplored.

4.
J Pers Med ; 13(5)2023 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-37240898

RESUMO

PURPOSE: To assess the ability of apparent diffusion coefficient (ADC) measurements in predicting the histological grade of endometrial cancer. A secondary goal was to assess the agreement between MRI and surgical staging as an accurate measurement. METHODS: Patients with endometrial cancers diagnosed between 2018-2020 and having received both MRI and surgical staging were retrospectively enrolled. Patients were characterized according to histology, tumor size, FIGO stage (MRI and surgical stage), and functional MRI parameters (DCE and DWI/ADC). Statistical analysis was performed to determine if an association could be identified between ADC variables and histology grade. Secondarily, we assessed the degree of agreement between the MRI and surgical stages according to the FIGO classification. RESULTS: The cohort included 45 women with endometrial cancer. Quantitative analysis of ADC variables did not find a statistically significant association with histological tumor grades. DCE showed higher sensitivity than DWI/ADC in the assessment of myometrial invasion (85.00% versus 65.00%) with the same specificity (80.00%). A good agreement between MRI and histopathology for the FIGO stage was found (kappa of 0.72, p < 0.01). Differences in staging between MRI and surgery were detected in eight cases, which could not be justified by the interval between MRI and surgery. CONCLUSIONS: ADC values were not useful for predicting endometrial cancer grade, despite the good agreement between MRI interpretation and histopathology of endometrial cancer staging at our center.

5.
Eur Radiol Exp ; 6(1): 53, 2022 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-36344838

RESUMO

NAVIGATOR is an Italian regional project boosting precision medicine in oncology with the aim of making it more predictive, preventive, and personalised by advancing translational research based on quantitative imaging and integrative omics analyses. The project's goal is to develop an open imaging biobank for the collection and preservation of a large amount of standardised imaging multimodal datasets, including computed tomography, magnetic resonance imaging, and positron emission tomography data, together with the corresponding patient-related and omics-related relevant information extracted from regional healthcare services using an adapted privacy-preserving model. The project is based on an open-source imaging biobank and an open-science oriented virtual research environment (VRE). Available integrative omics and multi-imaging data of three use cases (prostate cancer, rectal cancer, and gastric cancer) will be collected. All data confined in NAVIGATOR (i.e., standard and novel imaging biomarkers, non-imaging data, health agency data) will be used to create a digital patient model, to support the reliable prediction of the disease phenotype and risk stratification. The VRE that relies on a well-established infrastructure, called D4Science.org, will further provide a multiset infrastructure for processing the integrative omics data, extracting specific radiomic signatures, and for identification and testing of novel imaging biomarkers through big data analytics and artificial intelligence.


Assuntos
Inteligência Artificial , Medicina de Precisão , Medicina de Precisão/métodos , Bancos de Espécimes Biológicos , Tomografia por Emissão de Pósitrons , Biomarcadores
6.
Eur J Radiol Open ; 9: 100429, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35757232

RESUMO

Purpose: Differentiating Warthin tumor (WT) from pleomorphic adenoma (PA) is of primary importance due to differences in patient management, treatment and outcome. We sought to evaluate the performance of MRI-based radiomic features in discriminating PA from WT in the preoperative setting. Methods: We retrospectively evaluated 81 parotid gland lesions (48 PA and 33 WT) on T2-weighted (T2w) images and 52 of them on post-contrast fat-suppressed T1-weighted (pcfsT1w) images. All MRI examinations were carried out on a 1.5-Tesla MRI scanner, and images were segmented manually using the software ITK-SNAP (www.itk-snap.org). Results: The most discriminative feature on pcfsT1w images was GLCM_InverseVariance, yielding area under the curve (AUC), sensitivity and specificity of 0.9, 86 % and 87 %, respectively. Skewness was the feature extracted from T2w images with the highest specificity (88 %) in discriminating WT from PA. Conclusion: Radiomic analysis could be an important tool to improve diagnostic accuracy in differentiating PA from WT.

7.
Eur Radiol ; 32(5): 3173-3186, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35001159

RESUMO

BACKGROUND AND OBJECTIVE: The systematic collection of medical images combined with imaging biomarkers and patient non-imaging data is the core concept of imaging biobanks, a key element for fuelling the development of modern precision medicine. Our purpose is to review the existing image repositories fulfilling the criteria for imaging biobanks. METHODS: Pubmed, Scopus and Web of Science were searched for articles published in English from January 2010 to July 2021 using a combination of the terms: "imaging" AND "biobanks" and "imaging" AND "repository". Moreover, the Community Research and Development Information Service (CORDIS) database ( https://cordis.europa.eu/projects ) was searched using the terms: "imaging" AND "biobanks", also including collections, projects, project deliverables, project publications and programmes. RESULTS: Of 9272 articles retrieved, only 54 related to biobanks containing imaging data were finally selected, of which 33 were disease-oriented (61.1%) and 21 population-based (38.9%). Most imaging biobanks were European (26/54, 48.1%), followed by American biobanks (20/54, 37.0%). Among disease-oriented biobanks, the majority were focused on neurodegenerative (9/33, 27.3%) and oncological diseases (9/33, 27.3%). The number of patients enrolled ranged from 240 to 3,370,929, and the imaging modality most frequently involved was MRI (40/54, 74.1%), followed by CT (20/54, 37.0%), PET (13/54, 24.1%), and ultrasound (12/54, 22.2%). Most biobanks (38/54, 70.4%) were accessible under request. CONCLUSIONS: Imaging biobanks can serve as a platform for collecting, sharing and analysing medical images integrated with imaging biomarkers, biological and clinical data. A relatively small proportion of current biobanks also contain images and can thus be classified as imaging biobanks. KEY POINTS: • Imaging biobanks are a powerful tool for large-scale collection and processing of medical images integrated with imaging biomarkers and patient non-imaging data. • Most imaging biobanks retrieved were European, disease-oriented and accessible under user request. • While many biobanks have been developed so far, only a relatively small proportion of them are imaging biobanks.


Assuntos
Bancos de Espécimes Biológicos , Medicina de Precisão , Biomarcadores , Bases de Dados Factuais , Diagnóstico por Imagem , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA