Heart Rhythm O2 ; 2(3): 271-279, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34337578

RESUMO

BACKGROUND: Ventricular tachycardia (VT) catheter ablation success may be limited when transcutaneous epicardial access is contraindicated. Surgical ablation (SurgAbl) is an option, but ablation guidance is limited without simultaneously acquired electrophysiological data. OBJECTIVE: We describe our SurgAbl experience utilizing contemporary electroanatomic mapping (EAM) among patients with refractory VT storm. METHODS: Consecutive patients with recurrent VT despite antiarrhythmic drugs (AADs) and prior ablation, for whom percutaneous epicardial access was contraindicated, underwent open SurgAbl using intraoperative EAM guidance. RESULTS: Eight patients were included, among whom mean age was 63 ± 5 years, all were male, mean left ventricular ejection fraction was 39% ± 12%, and 2 (25%) had ischemic cardiomyopathy. Reasons for surgical epicardial access included dense adhesions owing to prior cardiac surgery, hemopericardium, or pericarditis (n = 6); or planned left ventricular assist device (LVAD) implantation at time of SurgAbl (n = 2). Cryoablation guided by real-time EAM was performed in all. Goals of clinical VT noninducibility or core isolation were achieved in 100%. VT burden was significantly reduced, from median 15 to 0 events in the month pre- and post-SurgAbl (P = .01). One patient underwent orthotopic heart transplantation for recurrent VT storm 2 weeks post-SurgAbl. Over mean follow-up of 3.4 ± 1.7 years, VT storm-free survival was achieved in 6 (75%); all continued AADs, although at lower dose. CONCLUSION: Surgical mapping and ablation of refractory VT with use of contemporary EAM is feasible and effective, particularly among patients with contraindication to percutaneous epicardial access or with another indication for cardiac surgery.

2.
J Cardiovasc Electrophysiol ; 30(10): 1939-1948, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31257683

RESUMO

INTRODUCTION: While cardiac sarcoidosis (CS) carries a risk of ventricular arrhythmias (VAs) and sudden cardiac death (SCD), risk stratification of patients with CS and preserved left ventricular/right ventricular (LV/RV) systolic function remains challenging. We sought to evaluate the role of electrophysiologic testing and programmed electrical stimulation of the ventricle (EPS) in patients with suspected CS with preserved ventricular function. METHODS: One hundred twenty consecutive patients with biopsy-proven extracardiac sarcoidosis and preserved LV/RV systolic function underwent EPS. All patients had either probable CS defined by an abnormal cardiac positron emission tomography or cardiac magnetic resonance imaging, or possible CS with normal advanced imaging but abnormal echocardiogram (ECG), SAECG, Holter, or clinical factors. Patients were followed for 4.5 ± 2.6 years for SCD and VAs. RESULTS: Seven of 120 patients (6%) had inducible ventricular tachycardia (VT) with EPS and received an implantable cardioverter defibrillator (ICD). Three patients (43%) with positive EPS later had ICD therapies for VAs. Kaplan-Meier analysis stratified by EPS demonstrated a significant difference in freedom from VAs and SCD (P = 0.009), though this finding was driven entirely by patients within the cohort with probable CS (P = 0.018, n = 69). One patient with possible CS and negative EPS had unrecognized progression of the disease and unexplained death with evidence of CS at autopsy. CONCLUSIONS: EPS is useful in the risk stratification of patients with probable CS with preserved LV and RV function. A positive EPS was associated with VAs. While a negative EPS appeared to confer low risk, close follow-up is needed as EPS cannot predict fatal VAs related to new cardiac involvement or disease progression.


Assuntos
Potenciais de Ação , Arritmias Cardíacas/diagnóstico , Cardiomiopatias/diagnóstico , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Frequência Cardíaca , Sarcoidose/diagnóstico , Função Ventricular Esquerda , Função Ventricular Direita , Idoso , Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/terapia , Cardiomiopatias/mortalidade , Cardiomiopatias/fisiopatologia , Cardiomiopatias/terapia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Progressão da Doença , Cardioversão Elétrica/instrumentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Sarcoidose/mortalidade , Sarcoidose/fisiopatologia , Sarcoidose/terapia , Volume Sistólico , Sístole , Fatores de Tempo
3.
Med Care ; 48(3): 203-9, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20125047

RESUMO

BACKGROUND: Electronic health records (EHRs) are widely viewed as useful tools for supporting the provision of high quality healthcare. However, evidence regarding their effectiveness for this purpose is mixed, and existing studies have generally considered EHR usage a binary factor and have not considered the availability and use of specific EHR features. OBJECTIVE: To assess the relationship between the use of an EHR and the use of specific EHR features with quality of care. RESEARCH DESIGN: A statewide mail survey of physicians in Massachusetts conducted in 2005. The results of the survey were linked with Healthcare Effectiveness Data and Information Set (HEDIS) quality measures, and generalized linear regression models were estimated to examine the associations between the use of EHRs and specific EHR features with quality measures, adjusting for physician practice characteristics. SUBJECTS: A stratified random sample of 1884 licensed physicians in Massachusetts, 1345 of whom responded. Of these, 507 had HEDIS measures available and were included in the analysis (measures are only available for primary care providers). MEASURE: Performance on HEDIS quality measures. RESULTS: The survey had a response rate of 71%. There was no statistically significant association between use of an EHR as a binary factor and performance on any of the HEDIS measure groups. However, there were statistically significant associations between the use of many, but not all, specific EHR features and HEDIS measure group scores. The associations were strongest for the problem list, visit note and radiology test result EHR features and for quality measures relating to women's health, colon cancer screening, and cancer prevention. For example, users of problem list functionality performed better on women's health, depression, colon cancer screening, and cancer prevention measures, with problem list users outperforming nonusers by 3.3% to 9.6% points on HEDIS measure group scores (all significant at the P < 0.05 level). However, these associations were not universal. CONCLUSIONS: Consistent with past studies, there was no significant relationship between use of EHR as a binary factor and performance on quality measures. However, availability and use of specific EHR features by primary care physicians was associated with higher performance on certain quality measures. These results suggest that, to maximize health care quality, developers, implementers and certifiers of EHRs should focus on increasing the adoption of robust EHR systems and increasing the use of specific features rather than simply aiming to deploy an EHR regardless of functionality.


Assuntos
Sistemas Computadorizados de Registros Médicos/organização & administração , Qualidade da Assistência à Saúde/organização & administração , Doença Crônica/terapia , Técnicas e Procedimentos Diagnósticos/estatística & dados numéricos , Humanos , Programas de Rastreamento/estatística & dados numéricos , Massachusetts , Neoplasias/diagnóstico , Medicamentos sob Prescrição , Atenção Primária à Saúde/estatística & dados numéricos , Indicadores de Qualidade em Assistência à Saúde/estatística & dados numéricos