Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Nature ; 562(7727): 386-390, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30305732

RESUMO

Despite considerable efforts over the past decade, only 34 fast radio bursts-intense bursts of radio emission from beyond our Galaxy-have been reported1,2. Attempts to understand the population as a whole have been hindered by the highly heterogeneous nature of the searches, which have been conducted with telescopes of different sensitivities, at a range of radio frequencies, and in environments corrupted by different levels of radio-frequency interference from human activity. Searches have been further complicated by uncertain burst positions and brightnesses-a consequence of the transient nature of the sources and the poor angular resolution of the detecting instruments. The discovery of repeating bursts from one source3, and its subsequent localization4 to a dwarf galaxy at a distance of 3.7 billion light years, confirmed that the population of fast radio bursts is located at cosmological distances. However, the nature of the emission remains elusive. Here we report a well controlled, wide-field radio survey for these bursts. We found 20, none of which repeated during follow-up observations between 185-1,097 hours after the initial detections. The sample includes both the nearest and the most energetic bursts detected so far. The survey demonstrates that there is a relationship between burst dispersion and brightness and that the high-fluence bursts are the nearby analogues of the more distant events found in higher-sensitivity, narrower-field surveys5.

2.
J Invest Dermatol ; 132(8): 2005-9, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22475754

RESUMO

Health maintenance organization (HMO) administrative databases have been used as sampling frames for ascertaining nonmelanoma skin cancer (NMSC). However, because of the lack of tumor registry information on these cancers, these ascertainment methods have not been previously validated. NMSC cases arising from patients served by a staff model medical group and diagnosed between 1 January 2007 and 31 December 2008 were identified from claims data using three ascertainment strategies. These claims data cases were then compared with NMSC identified using natural language processing (NLP) of electronic pathology reports (EPRs), and sensitivity, specificity, positive and negative predictive values were calculated. Comparison of claims data-ascertained cases with the NLP demonstrated sensitivities ranging from 48 to 65% and specificities from 85 to 98%, with ICD-9-CM ascertainment demonstrating the highest case sensitivity, although the lowest specificity. HMO health plan claims data had a higher specificity than all-payer claims data. A comparison of EPR and clinic log registry cases showed a sensitivity of 98% and a specificity of 99%. Validation of administrative data to ascertain NMSC demonstrates respectable sensitivity and specificity, although NLP ascertainment was superior. There is a substantial difference in cases identified by NLP compared with claims data, suggesting that formal surveillance efforts should be considered.


Assuntos
Revisão da Utilização de Seguros , Neoplasias Cutâneas/diagnóstico , Neoplasias Cutâneas/epidemiologia , Adulto , Idoso , Algoritmos , Carcinoma Basocelular/diagnóstico , Carcinoma Basocelular/epidemiologia , Carcinoma Basoescamoso/diagnóstico , Carcinoma Basoescamoso/epidemiologia , Carcinoma de Células Escamosas/diagnóstico , Carcinoma de Células Escamosas/epidemiologia , Humanos , Seguro Saúde , Sistemas Computadorizados de Registros Médicos , Pessoa de Meia-Idade , Processamento de Linguagem Natural , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Programa de SEER , Sensibilidade e Especificidade , Estados Unidos
3.
Am J Clin Pathol ; 131(4): 468-77, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19289582

RESUMO

Misidentification defects are a potential patient safety issue in medicine, including in the surgical pathology laboratory. In addressing the Joint Commission's national patient safety goal of accurate patient and specimen identification, we focused our lens internally on our own laboratory processes, with measurement tools designed to identify potential misidentification defects and their root causes. Based on this knowledge, aligned with our lean work culture in the Henry Ford Production System, we redesigned our surgical pathology laboratory workflow with simplified connections and pathways reinforced by a bar code technology innovation to specify and standardize work processes. We also adopted just-in-time prestain slide labeling with solvent-impervious, bar-coded slide labels at the microtome station, eliminating the loop-back pathway of poststain, batch slide matching, and labeling with adhesive paper labels. These changes have enabled us to dramatically reduce the overall misidentification case rate by approximately 62% with an approximate 95% reduction in the more common histologic slide misidentification defects while increasing technical throughput at the histology microtomy station by 125%.


Assuntos
Processamento Eletrônico de Dados/métodos , Erros Médicos/prevenção & controle , Patologia Cirúrgica/métodos , Garantia da Qualidade dos Cuidados de Saúde/métodos , Manejo de Espécimes/métodos , Humanos , Laboratórios Hospitalares/normas
4.
Chest ; 94(5): 1103-5, 1988 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-3180865

RESUMO

Patent ductus arteriosus presenting in an elderly patient is unusual. This report describes the oldest patient (72 years) to undergo successful surgical interruption of a patent ductus arteriosus with a unique clinical presentation of typical angina pectoris with normal coronary anatomy. A possible pathophysiologic mechanism for this previously unreported presenting symptom is proposed. The natural history of patent ductus arteriosus and the role of surgery in the elderly patient are discussed.


Assuntos
Permeabilidade do Canal Arterial/cirurgia , Idoso , Angina Pectoris/etiologia , Permeabilidade do Canal Arterial/complicações , Feminino , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA