Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Semin Oncol Nurs ; 40(3): 151618, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38622044

RESUMO

OBJECTIVES: To identify the prevalence and type of central venous access device-associated skin complications for adult cancer patients, describe central venous access device management practices, and identify clinical and demographic characteristics associated with risk of central venous access device-associated skin complications. METHODS: A prospective cohort study of 369 patients (626 central venous access devices; 7,682 catheter days) was undertaken between March 2017 and March 2018 across two cancer care in-patient units in a large teaching hospital. RESULTS: Twenty-seven percent (n = 168) of participants had a central venous access device-associated skin complication. In the final multivariable analysis, significant (P < .05) risk factors for skin complications were cutaneous graft versus host disease (2.1 times greater risk) and female sex (1.4 times greater risk), whereas totally implanted vascular access device reduced risk for skin complications by two-thirds (incidence risk ratio 0.37). CONCLUSION: Central venous access device-associated skin complications are a significant, potentially avoidable injury, requiring cancer nurses to be aware of high-risk groups and use evidence-based preventative and treatment strategies. IMPLICATIONS FOR PRACTICE: This study has confirmed how common these potentially preventable injuries are. Therefore, the prevalence of these complications could be reduced by focusing on improvements in skin assessment, reductions in central venous access device dressing variation and improving clinician knowledge of this injury.


Assuntos
Cateterismo Venoso Central , Neoplasias , Humanos , Feminino , Masculino , Estudos Prospectivos , Pessoa de Meia-Idade , Idoso , Adulto , Cateterismo Venoso Central/efeitos adversos , Cateteres Venosos Centrais/efeitos adversos , Dermatopatias/etiologia , Dermatopatias/epidemiologia , Fatores de Risco , Idoso de 80 Anos ou mais , Estudos de Coortes
2.
J Pediatr Nurs ; 76: 68-75, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38364591

RESUMO

PURPOSE: Children with chronic and complex health conditions frequently need intravenous devices. The current approach to intravenous device selection, insertion, and monitoring is inconsistent, and healthcare consumers are often negatively affected by siloed health information, and poor future planning. Despite child- and family-centred care being recognised as a pillar of paediatric nursing care, limited implementation for vascular access device planning and management is evident. DESIGN AND METHODS: To address this, we conducted a multi-phased approach to co-create, then evaluate, a mobile health (mHealth) application: IV Passport. Co-creation involved a prioritisation survey, followed by a Passport advisory panel consensus meeting. Following confirmation of the required content and features of the Passport, the mHealth application was designed and content validation achieved via survey. RESULTS: The prioritisation survey yielded recommendations for seven features (e.g., graphical presentations of current/past devices). Content for nine device types (e.g., totally implanted ports) was suggested, each with 10 related items (e.g., insertion site). Content items for device-associated complications, future vascular access plans, and educational resources were also suggested. Following design, the application was released through Apple and Android platforms; and adapted to a paper version. Content validation was established; 100% strongly agreed the application was easy to use; 80% agreed/strongly agreed that they would recommend the Passport to others. CONCLUSION: IV Passport embodies effective child- and family-centred care through consumer co-creation to empower patients and families manage vascular access devices. PRACTICE IMPLICATIONS: IV Passport remains active; and can be utilised across many healthcare settings and patient populations.


Assuntos
Telemedicina , Dispositivos de Acesso Vascular , Humanos , Criança , Aplicativos Móveis , Masculino , Feminino , Doença Crônica , Enfermagem Pediátrica
3.
J Clin Nurs ; 33(5): 1762-1776, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38413831

RESUMO

BACKGROUND: Healthcare consumers require diverse resources to assist their navigation of complex healthcare interactions, however, these resources need to be fit for purpose. AIM: In this study, we evaluated the utility, usability and feasibility of children, families and adults requiring long-term intravenous therapy using a recently developed mobile health application (App), intravenous (IV) Passport. DESIGN: Multi-site, parallel, multi-method, prospective cohort study. METHODS: A multi-site, multi-method study was carried out in 2020-2021, with 46 participants (20 adults, 26 children/family) reporting on their experiences surrounding the use of the IV Passport for up to 6 months. RESULTS: Overall, utility rates were acceptable, with 78.3% (N = 36) using the IV Passport over the follow-up period, with high rates of planned future use for those still active in the project (N = 21; 73%), especially in the child/family cohort (N = 13; 100%). Acceptability rates were high (9/10; IQR 6.5-10), with the IV Passport primarily used for documenting new devices and complications. Thematic analysis revealed three main themes (and multiple subthemes) in the qualitative data: Advocacy for healthcare needs, Complexity of healthcare and App design and functionality. CONCLUSION: Several recommendations were made to improve the end-user experience including 'how to' instructions; and scheduling functionality for routine care. IMPLICATIONS FOR THE PROFESSION AND/OR PATIENT CARE: The IV Passport can be safely and appropriately integrated into healthcare, to support consumers. IMPACT: Patient-/parent-reported feedback suggests the Intravenous Passport is a useful tool for record-keeping, and positive communication between patients/parents, and clinicians. REPORTING METHOD: Not applicable. PATIENT CONTRIBUTION: Consumers reported their experiences surrounding the use of the IV Passport for up to 6 months.


Assuntos
Telemedicina , Adulto , Criança , Humanos , Estudos Prospectivos , Telemedicina/métodos , Atenção à Saúde , Pais , Comunicação
4.
Cardiol Young ; : 1-7, 2023 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-37927298

RESUMO

BACKGROUND: CHD is associated with considerable burden of care. Up to one-third of babies born with CHD require surgery or intervention during the first year of life with an associated increased risk of surgical site infection. Pediatric wound care is informed largely by adult data, with no national or international guidelines available. AIM: To examine pediatric cardiac surgical wound care practices reported by healthcare professionals Australia and New Zealand-wide. METHODS: A bi-national cross-sectional survey exploring pre-, intra- and post-operative wound practices was distributed using Exponential Non-Discriminative Snowball Sampling. Data were subject to descriptive analysis using SPSS Statistics 22.0. FINDINGS: Sixty-eight surveys representing all Australian and New Zealand pediatric cardiac surgical services were analyzed. Most respondents were experienced nurses. Pre-operative care varied greatly in practice and pharmaceutical agents used. Little consistency was reported for intra- and post-operative wound care. Nursing and medical staff shared responsibility for wound care. Wound photography was widely used, but only uploaded to electronic medical records by some. DISCUSSION: These results highlight that wound care management is largely informed at an institutional level. The many practices reported are likely to reflect a range of factors including cardiac condition complexity, surgery, prematurity, and the presence of scar tissue. The importance of a research and training program, which is multimodal, available, and reflective, is highlighted. CONCLUSION: These findings call for the establishment of a nurse-led program of research and education. The resultant suite of cardiac wound strategies could offer an effective and consistent pathway forward.

5.
Aust Crit Care ; 36(2): 201-207, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35221230

RESUMO

OBJECTIVE: The objective of this study was to audit current patient blood management practice in children throughout cardiac surgery and paediatric intensive care unit (PICU) admission. DESIGN: This was a prospective observational cohort study. SETTING: This was a single-centre study in the cardiac operating room (OR) and PICU in a major tertiary children's hospital in Australia. PATIENTS: Children undergoing corrective cardiac surgery and requiring admission to PICU for postoperative recovery were included in the study. MEASUREMENTS AND MAIN RESULTS: Fifty-six patients and 1779 blood sampling episodes were audited over a 7-month period. The median age was 9 months (interquartile range [IQR] = 1-102), with the majority (n = 30 [54%]) younger than 12 months. The median number of blood sampling episodes per patient per day was 6.6 (IQR = 5.8-8.0) in total, with a median of 5.0 (IQR = 4.0-7.5) episodes in the OR and 5.0 (IQR = 3.4-6.2) episodes per day throughout PICU admission. The most common reason for blood tests across both OR and PICU settings was arterial blood gas analysis (total median = 86%, IQR = 79-96). The overall median blood sampling volume per kg of bodyweight, patient, and day was 0.63 mL (IQR = 0.20-1.14) in total. Median blood loss for each patient was 3.5 mL/kg per patient per day (IQR = 1.7-5.6) with negligible amounts in the OR and a median of 3.6 mL/kg (IQR = 1.7-5.7) in the PICU. The median Cell Saver® transfusion volume was 9.9 mL/kg per patient per day (IQR = 4.0-19.1) in the OR. The overall median volume of other infusion products (albumin 4%, albumin 20%, packed red blood cells) received by each patient was 20.1 mL/kg (IQR = 10.7-36.4) per day. Sampling events and blood loss were positively associated with PICU stay. CONCLUSIONS: Patient blood management practices observed in this study largely conform to National Blood Authority guidelines. Further implementation projects and research are needed to accelerate implementation of known effective blood conservation strategies within paediatric critical care environments.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Estado Terminal , Criança , Humanos , Lactente , Estudos de Coortes , Estudos Prospectivos , Unidades de Terapia Intensiva Pediátrica , Transfusão de Sangue
6.
Infect Dis Health ; 27(4): 175-183, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35739036

RESUMO

BACKGROUND: Needleless connectors (NCs) are essential devices designed to provide safe, needle-free connection between venous access devices, syringes and infusions. There is a variety of designs, and associated decontamination products and practices; the resulting confusion can cause detrimental patient outcomes. This study aimed to explore nurses' attitudes, techniques, and practices around the use and decontamination of NCs in clinical practice. METHODS: Qualitative inquiry was conducted with seven focus groups of 4-6 participants each in the cancer and surgical units of a large tertiary hospital in Australia between January and March 2019. Participants comprised nurses who had taken part in a recent clinical trial of NC decontamination. Focus group sessions were recorded, transcribed and synthesised using content analysis. RESULTS: Seven focus groups were conducted (total, N = 30 participants), lasting 16-20 min. Six major themes were identified surrounding needleless connector use and decontamination: 'safety and utility'; 'terminology and technological understanding'; 'clinical practice determinants'; 'decontamination procedures and influencers'; 'education and culture'; and 'research and innovation'. CONCLUSION: The participants articulated positive attitudes towards needleless connector use for needle-stick and infection prevention, however rationales for care and maintenance practices demonstrated limited understanding of guidelines (e.g., disinfection time) and specific NC function (e.g., positive, negative pressure). The findings indicated the need for targeted, standardised needleless connector education, to enhance staff confidence, improve consistency of care and ensure patient safety.


Assuntos
Contaminação de Equipamentos , Ferimentos Penetrantes Produzidos por Agulha , Humanos , Contaminação de Equipamentos/prevenção & controle , Descontaminação/métodos , Desinfecção , Austrália
7.
Cancer Nurs ; 45(6): 438-446, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35131974

RESUMO

BACKGROUND: Central venous access devices (CVADs) are integral to cancer care provision. Despite the high prevalence of CVAD complications in children with cancer, preventative strategies are understudied. OBJECTIVE: The aim of this study was to assess study feasibility, occlusive events, thrombolytic use, adverse events, and direct costs of catheter lock solutions. METHODS: A single-center, parallel-group, pilot randomized controlled trial was undertaken at a tertiary-referral pediatric hospital in Australia. Children 18 years or younger with an oncological or malignant hematological condition and a CVAD were eligible. Participants were 1:1 randomized to (1) normal or (2) heparinized (10-100 U/mL; CVAD-type dependent) saline lock solutions. RESULTS: Of 217 children assessed for eligibility, 61 were recruited and randomized to normal (n = 30; 3850 CVAD days) or heparinized (n = 31; 4036 CVAD days) saline. Eligibility (52%) and recruitment (54%) feasibility targets were not met. Protocol adherence was high (95% assessments), with no attrition. Parent/clinician satisfaction of interventions was high (median, 10/10 clinicians/parents). Complete CVAD occlusion occurred in heparin only (n = 2, 6.7% CVADs; incidence rate [IR], 0.49/1000 CVAD days [0.06-1.78]). Central venous access device partial occlusion was detected in 23.3% of CVADs in heparin (n = 7; IR, 2.73/1000 CVAD days [1.36-4.87]) and 13.8% of CVADs in normal saline (n = 4; IR, 2.59/1000 CVAD days [1.24-4.77]). Thrombolytic agents were used in 16.7% heparin (5 CVADs) and 3.5% normal saline (1 CVAD). Adverse events did not differ between groups. CONCLUSION: Multisite randomized controlled trials examining CVAD locks are safe, but strategies and resources to increase recruitment and eligibility are required. IMPLICATIONS FOR PRACTICE: Both routine CVAD lock solutions seem safe but may not prevent all forms of CVAD-associated harm.


Assuntos
Infecções Relacionadas a Cateter , Cateterismo Venoso Central , Cateteres Venosos Centrais , Neoplasias , Criança , Humanos , Infecções Relacionadas a Cateter/prevenção & controle , Cateterismo Venoso Central/efeitos adversos , Cateteres Venosos Centrais/efeitos adversos , Fibrinolíticos , Heparina/uso terapêutico , Neoplasias/tratamento farmacológico , Projetos Piloto , Solução Salina
8.
Infect Control Hosp Epidemiol ; 43(4): 427-434, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-33908337

RESUMO

OBJECTIVE: To examine the effectiveness of antimicrobial and antithrombogenic materials incorporated into peripherally inserted central catheters (PICCs) to prevent bloodstream infection, thrombosis, and catheter occlusion. METHODS: Prospective cohort study involving 52 hospitals participating in the Michigan Hospital Medicine Safety Consortium. Sample included adult hospitalized medical patients who received a PICC between January 2013 and October 2019. Coated and impregnated catheters were identified by name, brand, and device marketing or regulatory materials. Multivariable Cox proportional hazards models with robust sandwich standard error estimates accounting for the clustered nature of data were used to identify factors associated with PICC complications in coated versus noncoated devices across general care, intensive care unit (ICU), and oncology patients. Results were expressed as hazard ratios (HRs) with corresponding 95% confidence intervals (CIs). RESULTS: Of 42,562 patients with a PICC, 39,806 (93.5%) were plain polyurethane, 2,263 (5.3%) incorporated antimicrobial materials, and 921 (2.2%) incorporated antithrombogenic materials. Most were inserted in general ward settings (n = 28,111, 66.0%), with 12, 078 (28.4%) and 1,407 (3.3%) placed in ICU and oncological settings, respectively. Within the entire cohort, 540 (1.3%) developed thrombosis, 745 (1.8%) developed bloodstream infection, and 4,090 (9.6%) developed catheter occlusion. Adjusting for known risk factors, antimicrobial PICCs were not associated with infection reduction (HR, 1.16; 95% CI, 0.82-1.64), and antithrombogenic PICCs were not associated with reduction in thrombosis and occlusion (HR, 1.15; 95% CI, 0.92-1.44). Results were consistent across populations and care settings. CONCLUSIONS: Antimicrobial and antithrombogenic PICCs were not associated with a reduction in major catheter complications. Guidance aimed at informing use of these devices, balancing benefits against cost, appear necessary.


Assuntos
Anti-Infecciosos , Infecções Relacionadas a Cateter , Cateterismo Venoso Central , Cateterismo Periférico , Cateteres Venosos Centrais , Doenças Transmissíveis , Neoplasias , Sepse , Trombose , Adulto , Antibacterianos , Infecções Relacionadas a Cateter/epidemiologia , Infecções Relacionadas a Cateter/etiologia , Infecções Relacionadas a Cateter/prevenção & controle , Cateterismo Venoso Central/efeitos adversos , Cateterismo Periférico/efeitos adversos , Catéteres , Cateteres Venosos Centrais/efeitos adversos , Humanos , Estudos Prospectivos , Fatores de Risco , Sepse/etiologia , Trombose/etiologia , Trombose/prevenção & controle
9.
Int J Nurs Stud ; 124: 104095, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34689013

RESUMO

BACKGROUND: Peripheral intravenous catheters are an essential medical device which are prone to complications and failure. OBJECTIVES: Identify patient, provider and device risk factors associated with all-cause peripheral intravenous catheter failure as well as individual complications: phlebitis, infiltration/occlusion, and dislodgement to improve patient outcomes. DESIGN: Secondary analysis of twelve prospective studies performed between 2008 and 2020. SETTINGS: Australian metropolitan and regional hospitals including one paediatric hospital. PARTICIPANTS: Participants were from medical, surgical, haematology, and oncology units. METHODS: Multilevel mixed-effects parametric survival regression was used to identify factors associated with all-cause peripheral intravenous catheter failure, phlebitis, occlusion/infiltration, and dislodgement. We studied patient (e.g., age, gender), device (e.g., gauge), and provider (e.g., inserting clinician) variables. Stepwise regression involved clinically and p<0.20 significant variables entered into the multivariable model. Results were expressed as hazard ratios (HRs) and 95% confidence intervals (CI); p<0.01 was considered statistically significant. RESULTS: Of 11,830 peripheral intravenous catheters (8,200 participants) failure occurred in 36% (n = 4,263). Occlusion/infiltration incidence was 23% (n = 2,767), phlebitis 12% (n = 1,421), and dislodgement 7% (n = 779) of catheters. Patient factors significantly associated with failure and complications were: female gender (phlebitis; (HR 1.98, 95% CI 1.72-2.27), (infiltration/occlusion; HR 1.45, 95% CI 1.33-1.58), (failure; HR 1.36, 95% CI 1.26-1.46); and each year increase in age (phlebitis; 0.99 HR, 95% CI 0.98-0.99), (failure; 0.99 HR, 95% CI 0.99-0.99). The strongest provider risk factor was intravenous antibiotics (infiltration/occlusion; HR 1.40, 95% CI 1.27-1.53), (phlebitis; HR 1.36, 95% CI 1.18-1.56), (failure; HR 1.26, 95% CI 1.17-1.36). Catheters inserted by vascular access teams were less likely to dislodge (HR 0.53, 95% CI 0.42-0.67). Device risk factors most associated with all-cause failure were wrist/hand (HR 1.34, 95% CI 1.23-1.46), antecubital fossa peripheral intravenous catheters (HR 1.29, 95% CI 1.16-1.44) and 22/24 gauge (HR 1.27, 95% CI 1.12-1.45) catheters. CONCLUSION: Factors identified, including the protective aspect of vascular access team insertion, and high catheter failure associated with intravenous antibiotic administration, will allow targeted updates of peripheral intravenous catheter guidelines and models of care.


Assuntos
Cateterismo Periférico , Flebite , Austrália , Cateterismo Periférico/efeitos adversos , Catéteres , Criança , Feminino , Humanos , Flebite/epidemiologia , Flebite/etiologia , Estudos Prospectivos
10.
Paediatr Anaesth ; 31(9): 985-995, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34053159

RESUMO

BACKGROUND: The optimal intravenous device for antibiotic administration for children with respiratory disease is uncertain. We assessed the feasibility of a randomized controlled trial comparing midline catheters with peripherally inserted central catheters. METHODS: Prospective, two-arm, feasibility randomized controlled trial in an Australian tertiary, pediatric hospital. Random assignment of 110 children (<18 years) to receive (i) midline catheter and (ii) peripherally inserted central catheters. Primary outcome was feasibility (eligibility, recruitment, retention, protocol adherence, and acceptability), and the primary clinical outcome was general anesthesia requirement for intravenous catheter insertion. SECONDARY OUTCOMES: insertion time, treatment delays, infusion efficiency, device failure, complications, and cost. RESULTS: There was 80% recruitment, 100% retention, no missing data, and high patient/staff acceptability. Mean patient experience assessed on a 0-10 numeric rating scale was 8.0 peripherally inserted central catheters and 9.0 (midline catheters), respectively. Participant eligibility was not achieved (49% of screened patients) and moderate protocol-adherence across groups (89% peripherally inserted central catheters vs. 76% midline catheter). Insertion of midline catheter for pulmonary optimization reduced the requirement for general anesthesia compared to peripherally inserted central catheters (10% vs. 69%; odds ratio = 0.01, 95% confidence interval: 0.00-0.09). Midline catheters failed more frequently (18.1 vs. 5.5 peripherally inserted central catheters per 1000 catheter-days); however, this reduced over trial duration. Midline catheter insertion compared to peripherally inserted central catheters saved AUD$1451 per pulmonary optimization episode. CONCLUSIONS: An efficacy trial is feasible with expanded eligibility criteria and intensive staff training when introducing a new device. Midline catheter for peripherally compatible infusions is acceptable to patients and staff, might negate the need for general anesthesia and results in significant cost savings.


Assuntos
Cateterismo Venoso Central , Cateterismo Periférico , Cateteres Venosos Centrais , Anestesia Geral , Austrália , Criança , Estudos de Viabilidade , Humanos , Estudos Prospectivos
11.
Aust Crit Care ; 34(3): 235-240, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33069589

RESUMO

BACKGROUND: Transfusion of red blood cell (RBC) concentrates is a common procedure to restore blood volume and tissue oxygen delivery in patients with trauma. Although RBC warmers may prevent hypothermia, some warming or infusion equipment may lead to haemolysis and patient injury. OBJECTIVES: The aim of this study was to test the effect of (i) RBC warming and (ii) administration via manual vs. pump infusion on haemolysis. METHODS: This experimental ex vivo study studied haemolysis markers of RBC injury. The sample consisted of 90 RBC infusions in two simulations, randomly, 45 warmed RBC infusions and 45 nonwarmed RBC infusions, in two or three stages: before the intervention (baseline-warming, N= 45; nonwarming, N= 45), after water bath warming at 42 °C (warmed, N= 45), and then after the warmed or nonwarmed RBCs were infused by manual or pump infusion at a rate of 100 mL/h (infusion-warming, N= 45; nonwarming, N= 45). RESULTS: Warmed RBCs showed significantly lower total haemoglobin (Hb) and haematocrit levels and increase in free Hb levels, haemolysis levels, and lactate dehydrogenase (LDH) activity (all p<0.05) than baseline RBCs. Pump infusion RBCs were associated with reduced total Hb and increased free Hb, haemolysis, and potassium (K) levels (all p<0.05) compared with warmed RBCs. In contrast, manual infusion of warmed RBCs resulted in significantly reduced total Hb levels and increased LDH activity (both <0.05). After infusion, total Hb, free Hb, haematocrit, haemolysis, and LDH values were significantly different for warmed vs. nonwarmed RBCs (p<0.05). CONCLUSIONS: Haemolysis biomarkers increase with RBC warming and infusion, especially when using infusion pumps. Critically ill patients should be carefully monitored for possible complications during and after RBC infusion.


Assuntos
Eritrócitos , Hemólise , Biomarcadores , Humanos , Bombas de Infusão , Potássio
12.
Am J Med ; 134(2): e79-e88, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32673624

RESUMO

BACKGROUND: Peripherally inserted central catheter tip placement at the cavoatrial junction is associated with reduced catheter-related deep vein thrombosis. Electrocardiographic tip confirmation purportedly improves accuracy of tip placement, but whether this approach can reduce deep vein thrombosis is unknown. METHODS: Prospectively collected data from patients that received peripherally inserted central catheters at 52 Michigan hospitals were analyzed. The method used to confirm tip confirmation at insertion and deep vein thrombosis outcomes were extracted from medical records. Multivariate models (accounting for the clustered nature of the data) were fitted to assess the association between peripherally inserted central catheter-related deep vein thrombosis and method of tip confirmation (electrocardiographic vs radiographic imaging). RESULTS: A total of 42,687 peripherally inserted central catheters (21,098 radiology vs 21,589 electrocardiographic) were included. Patients receiving electrocardiographic-confirmed peripherally inserted central catheters had fewer comorbidities compared with those that underwent placement via radiology. Overall, deep vein thrombosis occurred in 594 (1.3%) of all peripherally inserted central catheters. Larger catheter size (odds radio [OR] 1.32; 95% confidence interval [CI], 0.93-1.90 per unit increase in gauge), history of deep vein thrombosis, and cancer were associated with increased risk of deep vein thrombosis (OR 2.00; 95% CI, 1.65-2.43 and OR 1.62; 95% CI, 1.16-2.26, respectively) using logistic regression. Following adjustment, electrocardiographic guidance was associated with a significant reduction in peripherally inserted central catheter-related deep vein thrombosis compared with radiographic imaging (OR 0.74; 95% CI, 0.58-0.93; P = .0098). CONCLUSION: The use of electrocardiography to confirm peripherally inserted central catheter tip placement at the cavoatrial junction was associated with significantly fewer deep vein thrombosis events than radiographic imaging. Use of this approach for peripherally inserted central catheter insertion may help improve patient safety, particularly in high-risk patients.


Assuntos
Cateterismo Venoso Central/efeitos adversos , Cateterismo Venoso Central/métodos , Cateteres Venosos Centrais/efeitos adversos , Trombose Venosa/etiologia , Idoso , Cateteres de Demora/efeitos adversos , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Risco , Trombose Venosa/prevenção & controle
13.
J Paediatr Child Health ; 56(12): 1875-1884, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32808404

RESUMO

AIM: Central venous access devices (CVADs) are vital medical devices to support the treatment of paediatric cancer; however, device occlusion is common, which disrupts treatment. This study aimed to improve the identification and management of CVAD occlusions in children with cancer, as well as to identify the demographic, clinical and device characteristics associated with increased risk for CVAD occlusion. METHODS: A pre-post-implementation study was conducted at a metropolitan paediatric oncology facility in Australia, using the Theoretical Domains Framework. Patients with a CVAD for anti-cancer therapy were prospectively followed for occlusive events pre- and post- the implementation of clinical resources to support the identification and management of CVAD occlusive events. CVAD occlusion and management data were collected and compared pre- and post-implementation. Risk factors for CVAD occlusion were described by mixed-effects Poisson regression and incident rate ratios (IRR). RESULTS: A total of 133 CVADs were inserted into 131 patients for a total of 6784 catheter days. The incidence of CVAD-related occlusion pre-implementation was 59.7 (95% confidence interval (CI) 51.4-69.0, per 1000 catheter days); compared to 31.6 (95% CI 26.4-37.6); P < 0.01) post-implementation of clinical resources. In multivariate models, other than post-implementation phases (IRR 0.51 (95% CI 0.32-0.81)), only neutropaenia significantly increased the risk of CVAD occlusion (IRR 2.14 (95% CI 1.15-3.97)). CONCLUSION: CVAD occlusions in paediatric oncology are common. The development and implementation of CVAD occlusion resources to guide the identification and management of occlusive episodes led to a significant decrease in occlusive events.


Assuntos
Cateterismo Venoso Central , Cateteres Venosos Centrais , Neoplasias , Austrália/epidemiologia , Cateterismo Venoso Central/efeitos adversos , Cateteres Venosos Centrais/efeitos adversos , Criança , Humanos , Incidência , Neoplasias/epidemiologia , Fatores de Risco
14.
Pediatrics ; 145(Suppl 3): S233-S242, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32482737

RESUMO

OBJECTIVES: To describe the methodology undertaken to provide guidance on the appropriateness, as well as inappropriateness, of vascular access device selection, characteristics, and insertion technique for pediatric patients. METHODS: The RAND Corporation-University of California, Los Angeles Appropriateness Method was used. After definition of key terms and scope, a systematic review of the pediatric vascular access literature was undertaken. Clinical scenarios were developed to reflect the common indications for vascular access across pediatric health care. These were sectioned according to (1) device selection, (2) device characteristics, and (3) insertion technique. An interdisciplinary panel of experts (N = 14) consisting of leading experts representing diverse pediatric clinical disciplines including anesthesiology, cardiology and cardiac surgery, critical care and emergency, general surgery, hematology and oncology, hospital medicine, infectious disease, interventional radiology, pharmacology, regional pediatric hospitalist, and vascular access nursing specialties was convened. The scenarios were rated for appropriateness by the panel over 2 rounds (1 [highly inappropriate] to 9 [highly appropriate]). Round 1 ratings were completed anonymously and independently by panel members and classified into 3 levels of appropriateness: appropriate, uncertain, and inappropriate, or disagreement. For round 2, panelists met in-person to discuss the round 1 ratings and independently rerated the indications. All indications were reclassified into 3 levels of appropriateness or disagreement. CONCLUSIONS: The RAND Corporation-University of California, Los Angeles Appropriateness Method provides a rigorous, in-depth and transparent methodology to develop the first appropriateness criteria for the selection of pediatric vascular access devices in a range of patient groups.


Assuntos
Centros Médicos Acadêmicos/normas , Cateterismo Periférico/normas , Guias de Prática Clínica como Assunto/normas , Dispositivos de Acesso Vascular/normas , Centros Médicos Acadêmicos/métodos , Cateterismo Periférico/métodos , Cateteres de Demora/normas , Criança , Pré-Escolar , Humanos , Lactente , Recém-Nascido , Los Angeles
15.
J Paediatr Child Health ; 56(1): 114-122, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31144404

RESUMO

AIM: Tonsillectomy procedures are a core element of paediatrics; however, perioperative management differs. This study aimed to describe tonsillectomy management, including the burden of pain, nausea and delayed recovery. METHODS: A prospective cohort study was undertaken through an audit of tonsillectomy perioperative practice and recovery and survey interviews with family members 7-14 days post-surgery. The study was undertaken at an Australian tertiary referral paediatric hospital between June and September 2016. RESULTS: The audit included 255 children undergoing tonsillectomy, with 127 family members interviewed. Most participants underwent adenotonsillectomy (n = 216; 85%), with a primary diagnosis of obstructive sleep apnoea (n = 205; 80%) and a mean age of 7 years (standard deviation; 3.9). A variety of intra-operative pain relief and antiemetics was administered. Pain was present in 29% (n = 26) of participants at ward return, increasing to 32-45% at 4-20 h and decreasing to 21% (n = 15) at discharge. A third of the children (32%; n = 41) had moderate to severe pain at post-discharge interview, and 30% (n = 38) experienced nausea at home. Most parents (82%; n = 104) were still giving regular paracetamol at 7 days post-operatively, and 31% (n = 39) had finished their oxycodone. Of the participants, 14% (n = 26) presented to the emergency department within 7 days of discharge; 8% (n = 20) of the total cohort were re-admitted. CONCLUSIONS: There was variety in perioperative and post-discharge care. Pain scores were infrequently documented post-tonsillectomy, and parents are generally dissatisfied with the management of post-operative pain and nausea. Further research is needed to provide a more consistent approach to perioperative management to promote recovery.


Assuntos
Pediatria , Tonsilectomia , Assistência ao Convalescente , Austrália , Criança , Estudos de Coortes , Humanos , Náusea , Dor Pós-Operatória/tratamento farmacológico , Alta do Paciente , Estudos Prospectivos , Tonsilectomia/efeitos adversos
16.
J Paediatr Child Health ; 56(2): 289-297, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31436918

RESUMO

AIM: To describe practice evolution, complications and risk factors for multiple insertion attempts and device failure in paediatric central venous access devices (CVADs). METHODS: A paediatric retrospective cohort study using prospectively collected data from CVAD database 2012-2014. Data included were patient (i.e. age, condition), insertion (i.e. indication, device, technique) and removal (complications, dwell). Descriptive statistics and incidence rates were calculated per calendar year and compared. Risk factors for multiple insertion attempts and failure were explored with logistic regression and cox regression, respectively. RESULTS: A total of 1308 CVADs were observed over 273 467 catheter-days in 863 patients. Multiple insertion attempts remained static (14%) and significantly associated with non-haematological oncology (odds ratio 2.19; 95% confidence interval (CI) 1.08-4.43), respiratory (3.71; 1.10-12.5), gastroenterology (4.18; 1.66-10.5) and other (difficult intravenous access) (2.74; 1.27-5.92). CVAD failure decreased from 35% (2012) to 25% (2014), incidence rate from 1.50 (95% CI 1.25-1.80) to 1.28 (1.06-1.54) per 1000 catheter-days. Peripherally inserted CVAD failure was significantly associated with lower body weight (per kilogram decrease, hazard ratio (HR) 1.02; 95% CI 1.00-1.03), cephalic vein (1.62; 1.05-2.62), difficult access (1.92; 1.02-3.73), sub-optimal tip placement (1.69; 1.06-2.69) and gastroenterology diagnosis (2.27; 1.05-4.90). Centrally placed CVAD failure was significantly associated with younger age (per year, HR 1.04; 95% CI 1.00-1.07), tunnelled device (3.38; 2.41-4.73) and gastroenterology diagnosis (1.70; 1.06-2.73). CONCLUSIONS: While advancement in CVAD practices improved overall CVAD insertion and failure outcomes, further improvements and innovation are necessary to ensure improved vessel health and preservation for children requiring CVAD.


Assuntos
Cateterismo Venoso Central , Cateteres Venosos Centrais , Cateterismo Venoso Central/efeitos adversos , Cateteres Venosos Centrais/efeitos adversos , Criança , Falha de Equipamento , Humanos , Incidência , Estudos Retrospectivos , Fatores de Risco
17.
J Pediatr Oncol Nurs ; 36(5): 343-351, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31104548

RESUMO

Central venous access devices (CVADs) are vital to enable treatment for children with cancer and other complex health conditions. However, complications effecting the CVAD wound are commonly reported. This study aimed to identify the incidence and prevalence of CVAD-associated skin complications current management, and characteristics associated with complication development, in pediatrics. A prospective observational study performed across medical, oncology, and hematology departments at a tertiary pediatric hospital in Australia, between April and July 2017. Children admitted with CVADs were assessed twice weekly for CVAD-associated skin complications and associated signs and symptoms. The data were analyzed using descriptive statistics (i.e., proportions, frequency) and time-to-event multivariable regression (i.e., hazard ratios [HRs]). Two hundred and seventy-one CVADs were reviewed over 43,787 catheter days, with over one eighth of participants (14%; n = 37) having a CVAD-associated skin complication during their admission (0.95 per 1,000 catheter days, 95% confidence interval [CI; 0.61, 1.17]), most commonly contact dermatitis (11%; n = 29; 0.72 per 1,000 catheter days 95% CI [0.50, 1.04]). Within biweekly checks the median point prevalence of complications varied between 0.4% and 11% and clinical management was wide-ranging. A primary diagnosis of oncology (HR 2.89, 95% CI [1.10, 7.62]) or medical/surgical (HR 2.55, 95% CI [1.04, 6.22]) conditions; plain, nonbordered polyurethane dressings (HR 4.92, 95% CI [2.00, 12.13]); and poor dressing integrity (HR 2.64, 95% CI [1.18, 5.92]) were significantly associated with contact dermatitis. In conclusion, substantial numbers of pediatric patients experience CVAD-associated skin complications, and innovations are necessary to identify, prevent, and treat these health care-associated injuries.


Assuntos
Infecções Relacionadas a Cateter/etiologia , Infecções Relacionadas a Cateter/terapia , Cateteres Venosos Centrais/efeitos adversos , Hospitais Pediátricos/estatística & dados numéricos , Pediatria/normas , Guias de Prática Clínica como Assunto , Dermatopatias/etiologia , Adolescente , Infecções Relacionadas a Cateter/epidemiologia , Criança , Pré-Escolar , Feminino , Humanos , Incidência , Masculino , Prevalência , Estudos Prospectivos , Queensland/epidemiologia , Dermatopatias/epidemiologia
18.
Int J Nurs Stud ; 91: 6-13, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30658228

RESUMO

BACKGROUND: Vascular access devices are widely used in healthcare settings worldwide. The insertion of a vascular access device creates a wound, vulnerable to irritation, injury and infection. Vascular access-associated skin complications are frequently reported in the literature, however very little evidence is available regarding the incidence and risk factors of these conditions to inform practice and technology development. OBJECTIVES: To estimate the incidence of vascular access-associated skin complications, and to identify patient, catheter and healthcare-related characteristics associated with skin complication development. DESIGN: Secondary data analysis from 13 multi-centre randomised controlled trials and observational studies evaluating technologies and performance of vascular access devices in clinical settings between 2008 and 2017. SETTINGS: Six hospitals (metropolitan and regional) in Queensland, Australia. PARTICIPANTS: The 13 studies involved paediatric and adult participants, across oncology, emergency, intensive care, and general hospital settings. A total of 7669 participants with 10,859 devices were included, involving peripheral venous (n = 9933), peripheral arterial (n = 341), and central venous access (n = 585) devices. ANALYSIS: Standardised study data were extracted into a single database. Clinical and demographic data were descriptively reported. Cox proportional hazards regression models (stratified by peripheral vs central) were used for time-to-event, per-device analyses to examine risk factors. Univariate associations were undertaken due to complexities with missing data in both outcomes and covariates, with p < 0.01 to reduce the effect of multiple comparisons. RESULTS: Over 12% of devices were associated with skin complication, at 46.2 per 1000 catheter days for peripheral venous and arterial devices (95% confidence interval, CI 42.1-50.7), and 22.5 per 1000 catheter days for central devices (95% CI 16.5-306). The most common skin complications were bruising (peripheral n = 134, 3.7%; central n = 33, 6.8%), and swelling due to infiltration for peripheral devices (n = 296; 2.9%), and dermatitis for central devices (n = 13; 2.2%). The significant risk factors for these complications were predominantly related to device (e.g., skin tears associated with peripheral arterial catheters [hazard ratio, HR 16.0], radial insertion [HR 18.0] basilic insertion [HR 26.0])) and patient characteristics (e.g., poor skin integrity associated with increased risk of peripheral device bruising [HR 4.12], infiltration [HR 1.98], and skin tear [HR 48.4]), rather than management approaches. CONCLUSIONS: Significant skin complications can develop during the life of peripheral and central vascular access devices, and these are associated with several modifiable and non-modifiable risk factors. Further research is needed to evaluate effectiveness technologies to prevent and treat skin complications associated with vascular access devices.


Assuntos
Dermatopatias/etiologia , Dispositivos de Acesso Vascular/efeitos adversos , Adolescente , Adulto , Idoso , Criança , Humanos , Incidência , Lactente , Recém-Nascido , Pessoa de Meia-Idade , Estudos Multicêntricos como Assunto , Estudos Observacionais como Assunto , Ensaios Clínicos Controlados Aleatórios como Assunto , Fatores de Risco , Adulto Jovem
20.
BMC Cancer ; 17(1): 595, 2017 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-28854967

RESUMO

BACKGROUND: Central venous access device (CVAD) associated complications are a preventable source of patient harm, frequently resulting in morbidity and delays to vital treatment. Dressing and securement products are used to prevent infectious and mechanical complications, however current complication rates suggest customary practices are inadequate. The aim of this study was to evaluate the feasibility of launching a full-scale randomized controlled efficacy trial of innovative dressing and securement products for pediatric tunneled CVAD to prevent complication and failure. METHODS: An external, pilot, four-group randomized controlled trial of standard care (bordered polyurethane dressing and suture), in comparison to integrated securement-dressing, suture-less securement device, and tissue adhesive was undertaken across two large, tertiary referral pediatric hospitals in Australia. Forty-eight pediatric participants with newly inserted tunneled CVADs were consecutively recruited. The primary outcome of study feasibility was established by elements of eligibility, recruitment, attrition, protocol adherence, missing data, parent and healthcare staff satisfaction and acceptability, and effect size estimates for CVAD failure (cessation of function prior to completion of treatment) and complication (associated bloodstream infection, thrombosis, breakage, dislodgement or occlusion). Dressing integrity, product costs and site complications were also examined. RESULTS: Protocol feasibility was established. CVAD failure was: 17% (2/12) integrated securement-dressing; 8% (1/13) suture-less securement device; 0% tissue adhesive (0/12); and, 0% standard care (0/11). CVAD complications were: 15% (2/13) suture-less securement device (CVAD associated bloodstream infection, and occlusion and partial dislodgement); 8% (1/12) integrated securement-dressing (partial dislodgement); 0% tissue adhesive (0/12); and, 0% standard care (0/11). One CVAD-associated bloodstream infection occurred, within the suture-less securement device group. Overall satisfaction was highest in the integrated securement-dressing (mean 8.5/10; standard deviation 1.2). Improved dressing integrity was evident in the intervention arms, with the integrated securement-dressing associated with prolonged time to first dressing change (mean days 3.5). CONCLUSIONS: Improving the security and dressing integrity of tunneled CVADs is likely to improve outcomes for pediatric patients. Further research is necessary to identify novel, effective CVAD securement to reduce complications, and provide reliable vascular access for children. TRIAL REGISTRATION: ACTRN12614000280606 ; prospectively registered on 17/03/2014.


Assuntos
Infecções Relacionadas a Cateter/prevenção & controle , Austrália , Bandagens , Cateteres Venosos Centrais , Criança , Pré-Escolar , Falha de Equipamento , Estudos de Viabilidade , Feminino , Humanos , Lactente , Masculino , Projetos Piloto , Poliuretanos/química , Veias/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA