Phys Med Biol ; 59(23): 7229-44, 2014 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-25383509

RESUMO

In clinical ion beam therapy, protons as well as heavier ions such as carbon are used for treatment. For protons, ß(+)-emitters are only induced by fragmentation reactions in the target (target fragmentation), whereas for heavy ions, they are additionally induced by fragmentations of the projectile (further referred to as autoactivation). An approach utilizing these processes for treatment verification, by comparing measured Positron Emission Tomography (PET) data to predictions from Monte Carlo simulations, has already been clinically implemented. For an accurate simulation, it is important to consider the biological washout of ß(+)-emitters due to vital functions. To date, mathematical expressions for washout have mainly been determined by using radioactive beams of (10)C- and (11)C-ions, both ß(+)-emitters, to enhance the counting statistics in the irradiated area. Still, the question of how the choice of projectile (autoactivating or non-autoactivating) influences the washout coefficients, has not been addressed. In this context, an experiment was carried out at the Heidelberg Ion Beam Therapy Center with the purpose of directly comparing irradiation-induced biological washout coefficients in mice for protons and (12)C-ions. To this aim, mice were irradiated in the brain region with protons and (12)C-ions and measured after irradiation with a PET/CT scanner (Siemens Biograph mCT). After an appropriate waiting time, the mice were sacrificed, then irradiated and measured again under similar conditions. The resulting data were processed and fitted numerically to deduce the main washout parameters. Despite the very low PET counting statistics, a consistent difference could be identified between (12)C-ion and proton irradiated mice, with the (12)C data being described best by a two component fit with a combined medium and slow washout fraction of 0.50 ± 0.05 and the proton mice data being described best by a one component fit with only one (slow) washout fraction of 0.73 ± 0.06.


Assuntos
Encéfalo/diagnóstico por imagem , Tomografia por Emissão de Pósitrons , Terapia com Prótons , Algoritmos , Animais , Partículas beta , Encéfalo/efeitos da radiação , Radioisótopos de Carbono/farmacocinética , Meia-Vida , Taxa de Depuração Metabólica , Camundongos
2.
Phys Med Biol ; 59(19): 5903-19, 2014 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-25211629

RESUMO

We introduce the automation of the range difference calculation deduced from particle-irradiation induced ß(+)-activity distributions with the so-called most-likely-shift approach, and evaluate its reliability via the monitoring of algorithm- and patient-specific uncertainty factors. The calculation of the range deviation is based on the minimization of the absolute profile differences in the distal part of two activity depth profiles shifted against each other. Depending on the workflow of positron emission tomography (PET)-based range verification, the two profiles under evaluation can correspond to measured and simulated distributions, or only measured data from different treatment sessions. In comparison to previous work, the proposed approach includes an automated identification of the distal region of interest for each pair of PET depth profiles and under consideration of the planned dose distribution, resulting in the optimal shift distance. Moreover, it introduces an estimate of uncertainty associated to the identified shift, which is then used as weighting factor to 'red flag' problematic large range differences. Furthermore, additional patient-specific uncertainty factors are calculated using available computed tomography (CT) data to support the range analysis. The performance of the new method for in-vivo treatment verification in the clinical routine is investigated with in-room PET images for proton therapy as well as with offline PET images for proton and carbon ion therapy. The comparison between measured PET activity distributions and predictions obtained by Monte Carlo simulations or measurements from previous treatment fractions is performed. For this purpose, a total of 15 patient datasets were analyzed, which were acquired at Massachusetts General Hospital and Heidelberg Ion-Beam Therapy Center with in-room PET and offline PET/CT scanners, respectively. Calculated range differences between the compared activity distributions are reported in a 2D map in beam-eye-view. In comparison to previously proposed approaches, the new most-likely-shift method shows more robust results for assessing in-vivo the range from strongly varying PET distributions caused by differing patient geometry, ion beam species, beam delivery techniques, PET imaging concepts and counting statistics. The additional visualization of the uncertainties and the dedicated weighting strategy contribute to the understanding of the reliability of observed range differences and the complexity in the prediction of activity distributions. The proposed method promises to offer a feasible technique for clinical routine of PET-based range verification.


Assuntos
Neoplasias de Cabeça e Pescoço/radioterapia , Radioterapia com Íons Pesados/métodos , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons/métodos , Terapia com Prótons/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Incerteza , Algoritmos , Automação , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Humanos , Método de Monte Carlo , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos
3.
Phys Med Biol ; 59(16): 4635-59, 2014 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-25079387

RESUMO

Monte Carlo (MC) simulations of beam interaction and transport in matter are increasingly considered as essential tools to support several aspects of radiation therapy. Despite the vast application of MC to photon therapy and scattered proton therapy, clinical experience in scanned ion beam therapy is still scarce. This is especially the case for ions heavier than protons, which pose additional issues like nuclear fragmentation and varying biological effectiveness. In this work, we present the evaluation of a dedicated framework which has been developed at the Heidelberg Ion Beam Therapy Center to provide automated FLUKA MC simulations of clinical patient treatments with scanned proton and carbon ion beams. Investigations on the number of transported primaries and the dimension of the geometry and scoring grids have been performed for a representative class of patient cases in order to provide recommendations on the simulation settings, showing that recommendations derived from the experience in proton therapy cannot be directly translated to the case of carbon ion beams. The MC results with the optimized settings have been compared to the calculations of the analytical treatment planning system (TPS), showing that regardless of the consistency of the two systems (in terms of beam model in water and range calculation in different materials) relevant differences can be found in dosimetric quantities and range, especially in the case of heterogeneous and deep seated treatment sites depending on the ion beam species and energies, homogeneity of the traversed tissue and size of the treated volume. The analysis of typical TPS speed-up approximations highlighted effects which deserve accurate treatment, in contrast to adequate beam model simplifications for scanned ion beam therapy. In terms of biological dose calculations, the investigation of the mixed field components in realistic anatomical situations confirmed the findings of previous groups so far reported only in homogenous water targets. This work can thus be useful to other centers commencing clinical experience in scanned ion beam therapy.


Assuntos
Radioterapia com Íons Pesados , Método de Monte Carlo , Terapia com Prótons , Automação , Humanos , Planejamento da Radioterapia Assistida por Computador , Incerteza
4.
Phys Med Biol ; 59(1): 1-21, 2014 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-24323977

RESUMO

Since the interest in ion-irradiation for tumour therapy has significantly increased over the last few decades, intensive investigations are performed to improve the accuracy of this form of patient treatment. One major goal is the development of methods for in vivo dose verification. In proton therapy, a PET (positron emission tomography)-based approach measuring the irradiation-induced tissue activation inside the patient has been already clinically implemented. The acquired PET images can be compared to an expectation, derived under the assumption of a correct treatment application, to validate the particle range and the lateral field position in vivo. In the context of this work, TPSPET is introduced as a new approach to predict proton-irradiation induced three-dimensional positron emitter distributions by means of the same algorithms of the clinical treatment planning system (TPS). In order to perform additional activity calculations, reaction-channel-dependent input positron emitter depth distributions are necessary, which are determined from the application of a modified filtering approach to the TPS reference depth dose profiles in water. This paper presents the implementation of TPSPET on the basis of the research treatment planning software treatment planning for particles. The results are validated in phantom and patient studies against Monte Carlo simulations, and compared to ß(+)-emitter distributions obtained from a slightly modified version of the originally proposed one-dimensional filtering approach applied to three-dimensional dose distributions. In contrast to previously introduced methods, TPSPET provides a faster implementation, the results show no sensitivity to lateral field extension and the predicted ß(+)-emitter densities are fully consistent to the planned treatment dose as they are calculated by the same pencil beam algorithms. These findings suggest a large potential of the application of TPSPET for in vivo dose verification in the daily clinical routine.


Assuntos
Tomografia por Emissão de Pósitrons , Terapia com Prótons/métodos , Doses de Radiação , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Humanos , Método de Monte Carlo , Imagens de Fantasmas , Dosagem Radioterapêutica
5.
Phys Med Biol ; 58(15): 5193-213, 2013 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-23835872

RESUMO

We report on the experimental campaign carried out at the Heidelberg Ion-Beam Therapy Center (HIT) to optimize the Monte Carlo (MC) modelling of proton-induced positron-emitter production. The presented experimental strategy constitutes a pragmatic inverse approach to overcome the known uncertainties in the modelling of positron-emitter production due to the lack of reliable cross-section data for the relevant therapeutic energy range. This work is motivated by the clinical implementation of offline PET/CT-based treatment verification at our facility. Here, the irradiation induced tissue activation in the patient is monitored shortly after the treatment delivery by means of a commercial PET/CT scanner and compared to a MC simulated activity expectation, derived under the assumption of a correct treatment delivery. At HIT, the MC particle transport and interaction code FLUKA is used for the simulation of the expected positron-emitter yield. For this particular application, the code is coupled to externally provided cross-section data of several proton-induced reactions. Studying experimentally the positron-emitting radionuclide yield in homogeneous phantoms provides access to the fundamental production channels. Therefore, five different materials have been irradiated by monoenergetic proton pencil beams at various energies and the induced ß(+) activity subsequently acquired with a commercial full-ring PET/CT scanner. With the analysis of dynamically reconstructed PET images, we are able to determine separately the spatial distribution of different radionuclide concentrations at the starting time of the PET scan. The laterally integrated radionuclide yields in depth are used to tune the input cross-section data such that the impact of both the physical production and the imaging process on the various positron-emitter yields is reproduced. The resulting cross-section data sets allow to model the absolute level of measured ß(+) activity induced in the investigated targets within a few per cent. Moreover, the simulated distal activity fall-off positions, representing the central quantity for treatment monitoring in terms of beam range verification, are found to agree within 0.6 mm with the measurements at different initial beam energies in both homogeneous and heterogeneous targets.


Assuntos
Método de Monte Carlo , Imagem Multimodal/métodos , Tomografia por Emissão de Pósitrons/métodos , Prótons , Tomografia Computadorizada por Raios X/métodos , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Terapia com Prótons