Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Cardiol J ; 30(6): 1010-1017, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37853823

RESUMO

BACKGROUND: A direct comparison of three-dimensional transesophageal echocardiography (3DTEE) and cardiac computed tomography imaging has demonstrated good inter-technique agreement for the following pulmonary vein (PV) parameters: the ostium area of the right superior PV (RSPV) and its major (a) and minor axis (b) diameters, the left lateral ridge and the minor axis (b) diameter of the left superior PV. Herein, under investigation, was the predictive value of these parameters for arrhythmia recurrence (AR) after PV isolation with the 28 mm second generation cryoballoon (CBG2). METHODS: One hundred eleven patients (67 men, mean age 58.06 ± 10.58 years) undergoing 3DTEE before PV isolation with the CBG2 for paroxysmal atrial fibrillation were followed. "Point by point" redo intervention was offered in case of AR and reconnected PVs were defined. RESULTS: During a mean follow-up of 617 ± 258.86 days, 65 (58.9%) patients remained free of AR. Longer RSPV b was found to be the only significant predictor for AR (hazard ratio [HR] 1.059; 95% confidence interval [CI] 1.000-1.121; p = 0.048). RSPV b ≥ 28 mm resulted in a threefold (HR 3.010; 95% CI 1.270-7.134, p = 0.012) increase in the risk of AR. The association of RSPV b with AR was independent of the biophysical parameters of cryoapplications. In 25 "redo" patients, reconnections were found 1.75 times more likely in the RSPV than in the other 3 PVs altogether. CONCLUSIONS: Right superior PV b measured with 3DTEE might be a significant predictor of AR after PV isolation with the CBG2. In case of RSPV b exceeding 28 mm, alternative PV isolation techniques or use of a larger balloon might be considered.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Resultado do Tratamento , Ecocardiografia Transesofagiana , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos
2.
Cardiovasc Ultrasound ; 21(1): 6, 2023 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-37076858

RESUMO

BACKGROUND: Anatomical characteristics of the left atrium and the pulmonary veins (PVs) may be relevant to the success rate of cryoballoon (CB)-ablation for atrial fibrillation (AF). Cardiac computed tomography (CCT) is considered as the gold standard for preablation imaging. Recently, three-dimensional transesophageal echocardiography (3DTOE) has been proposed for preprocedural assessment of cardiac structures relevant to CB-ablation. The accuracy of 3DTOE has not been validated by other imaging modalities. OBJECTIVE: We prospectively evaluated the feasibility and the accuracy of 3DTOE imaging for the assessment of left atrial and PV structures prior to pulmonary vein isolation (PVI). In addition, CCT was used to validate the measurements obtained with 3DTOE. METHODS: PV anatomy of 67 patients (59.7% men, mean age 58.5 ± 10.5 years) was assessed using both 3DTOE and CCT scan prior to PVI with the Arctic Front CB. The following parameters were measured bilaterally: PV ostium area (OA), the major and minor axis diameters of the ostium (a > b) and the width of the carina between the superior and the inferior PVs. In addition, the width of the left lateral ridge (LLR) between the left atrial appendage and the left superior PV. Evaluation of inter-technique agreement was based on linear regression with Pearson correlation coefficient (PCC) and Bland-Altman analysis of biases and limits of agreement. RESULTS: Moderate positive correlation (PCC 0.5-0.7) was demonstrated between the two imaging methods for the right superior PV's OA and both axis diameters, the width of the LLR and left superior PV (LSPV) minor axis diameter (b) with limits of agreement ˂50% and no significant biases. Low positive or negligible correlation (PCC < 0.5) was found for both inferior PV parameters. CONCLUSIONS: Detailed assessment of the right superior PV parameters, LLR and LSPV b is feasible with 3DTOE prior to AF ablation. This 3DTOE measurements demonstrated a clinically acceptable inter-technique agreement with those obtained with CCT.


Assuntos
Fibrilação Atrial , Criocirurgia , Veias Pulmonares , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Feminino , Ecocardiografia Transesofagiana/métodos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Criocirurgia/métodos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Tomografia Computadorizada por Raios X , Resultado do Tratamento
3.
J Clin Med ; 9(9)2020 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-32971765

RESUMO

BACKGROUND: Cerebral thromboembolism is a rare but feared complication of transcatheter ablation in patients with atrial fibrillation (AF). Here, we aimed to test which pre-procedural anticoagulation strategy results in less intracardiac activation of hemostasis during ablation. PATIENTS AND METHODS: In this observational study, 54 paroxysmal/persistent AF patients undergoing cryoballoon ablation were grouped according to their periprocedural anticoagulation strategy: no anticoagulation (oral anticoagulation (OAC) free; n = 24), uninterrupted vitamin K antagonists (VKA) (n = 11), uninterrupted dabigatran (n = 17). Blood was drawn from the left atrium before and immediately after the ablation procedure. Cryoablations were performed according to standard protocols, during which heparin was administered. Heparin-insensitive markers of hemostasis and endothelial damage were tested from intracardiac samples: D-dimer, quantitative fibrin monomer (FM), plasmin-antiplasmin complex (PAP), von Willebrand factor (VWF) antigen, chromogenic factor VIII (FVIII) activity. RESULTS: D-dimer increased significantly in all groups post-ablation, with lowest levels in the dabigatran group (median [interquartile range]: 0.27 [0.36] vs. 1.09 [1.30] and 0.74 [0.26] mg/L in OAC free and uninterrupted VKA groups, respectively, p < 0.001). PAP levels were parallel to this observation. Post-ablation FM levels were elevated in OAC free (26.34 [30.04] mg/L) and VKA groups (10.12 [16.01] mg/L), but remained below cut-off in all patients on dabigatran (3.98 [2.0] mg/L; p < 0.001). VWF antigen and FVIII activity increased similarly post-ablation in all groups, suggesting comparable procedure-related endothelial damage. CONCLUSION: Dabigatran provides greater inhibition against intracardiac activation of hemostasis as compared to VKAs during cryoballoon catheter ablation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA