RESUMO
OBJECTIVE: Patency of target arteries is crucial for fenestrated and branched endovascular aortic repair (F/B-EVAR) in thoracoabdominal aortic aneurysms (TAAAs). Occlusions more frequently occur in renal arteries (RAs) than in coeliac and superior mesenteric arteries, especially in patients with hostile anatomy treated by BEVAR. This study aimed to report RA outcomes using a hybrid bridging stent graft technique with distal self expandable (SE) combined with proximal balloon expandable (BE) stent graft during BEVAR with hostile RA anatomies. METHODS: Clinical data from consecutive patients treated for TAAA by F/B-EVAR in three aortic centres (two in the USA, one in Europe) from 2016 to 2022 were prospectively collected. Renal artery orientation was defined as hostile in case of upward (type B) or downward + upward (type D) orientation. Hostile RAs accommodated by BEVAR and combination of SE + BE stent grafts were retrospectively evaluated. Intra-operative RA related complications, technical success, and branch occlusions were assessed as early outcomes. Primary and secondary RA patency, freedom from RA related re-interventions, and freedom from RA instability were assessed during follow up. RESULTS: Of 584 TAAAs managed by F/B-EVAR, 83 patients (14.2%) had 125 hostile RAs (type B, 45.6%; type D, 54.4%) managed by BEVAR with hybrid SE + BE stent grafts. Intra-operative complications occurred in three RAs (2.4%), including two dissections and one disconnection, all successfully managed with additional stent. Technical success was achieved in all cases, with no RA occlusions at 30 days. The median follow up was 21 (interquartile range 4, 38) months. Estimated three year RA primary patency was 97 ± 2%. Re-interventions were performed in five RAs (4.0%), including two RA branch embolisations for bleeding, two catheter thrombectomies with stent relining (bilateral occlusion in one patient), and one revision of type Ic endoleak. Freedom from RA related re-interventions and RA instability was 95 ± 2% and 91 ± 3% at three years, respectively. Renal artery secondary patency was 99 ± 1% at three years. CONCLUSION: In hostile RA anatomies, a combination of distal SE and proximal BE stent grafts as bridging stenting in BEVAR is safe and effective, with low rates of occlusion, re-interventions, and branch instability at midterm follow up.
RESUMO
Background: Carotid endarterectomy (CEA) for the prevention of upcoming vascular and cerebral events is necessary in patients with high-grade stenosis (≥70%). In the framework of the Italian National project Age.It, a pilot study was proposed aiming at the discovery of a molecular signature with predictive potential of carotid stenosis comparing 65+ asymptomatic and symptomatic inpatients. Methods: A total of 42 inpatients have been enrolled, including 26 men and 16 women, with a mean age of 74 ± 6 years. Sixteen symptomatic and 26 asymptomatic inpatients with ≥70% carotid stenosis underwent CEA, according to the recommendations of the European Society for Vascular Surgery and the Society for Vascular Surgeons. Plaque biopsies and peripheral blood samples from the same individuals were obtained. Hematobiochemical analyses were conducted on all inpatients, and plasma cytokines/molecules, such as microRNAs (miRs), IL-6, sIL-6Ralpha, sgp130, myostatin (GDF8), follistatin, activin A, CXCL9, FGF21, and fibronectin, were measured using the ELISA standard technique. MiR profiles were obtained in the discovery phase including four symptomatic and four asymptomatic inpatients (both plasma and plaque samples), testing 734 miRs. MiRs emerging from the profiling comparison were validated through RT-qPCR analysis in the total cohort. Results and conclusion: The two groups of inpatients differ in the expression levels of blood c-miRs-126-5p and -1271-5p (but not in their plaques), which are more expressed in symptomatic subjects. Three cytokines were significant between the two groups: IL-6, GDF8, and CXCL9. Using receiver operating characteristic (ROC) analysis with a machine learning-based approach, the most significant blood molecular signature encompasses albumin, C-reactive protein (CRP), the percentage of monocytes, and CXCL9, allowing for the distinction of the two groups (AUC = 0.83, 95% c.i. [0.85, 0.81], p = 0.0028). The potential of the molecular signature will be tested in a second cohort of monitored patients, allowing the application of a predictive model and the final evaluation of cost/benefit for an assessable screening test.
Assuntos
Biomarcadores , Proteína C-Reativa , Quimiocina CXCL9 , Monócitos , Humanos , Masculino , Feminino , Projetos Piloto , Idoso , Proteína C-Reativa/metabolismo , Proteína C-Reativa/análise , Biomarcadores/sangue , Quimiocina CXCL9/sangue , Monócitos/metabolismo , Estenose das Carótidas/sangue , Endarterectomia das Carótidas , Doenças das Artérias Carótidas/sangue , Idoso de 80 Anos ou mais , Comorbidade , Albumina Sérica/análise , Albumina Sérica/metabolismoRESUMO
OBJECTIVE: As a result of conflicting, inadequate or controversial data in the literature, several issues concerning the management of patients with abdominal aortic aneurysms (AAAs) remain unanswered. The aim of this international, expert-based Delphi consensus document was to provide some guidance for clinicians on these controversial topics. METHODS: A three-round Delphi consensus document was produced with 44 experts on 6 prespecified topics regarding the management of AAAs. All answers were provided anonymously. The response rate for each round was 100%. RESULTS: Most participants (42 of 44 [95.4%]) agreed that a minimum case volume per year is essential (or probably essential) for a center to offer open or endovascular AAA repair (EVAR). Furthermore, 33 of 44 (75.0%) believed that AAA screening programs are (probably) still clinically effective and cost effective. Additionally, most panelists (36 of 44 [81.9%]) voted that surveillance after EVAR should be (or should probably be) lifelong. Finally, 35 of 44 participants (79.7%) thought that women smokers should (or should probably/possibly) be considered for screening at 65 years of age, similar to men. No consensus was achieved regarding lowering the threshold for AAA repair and the need for deep venous thrombosis prophylaxis in patients undergoing EVAR. CONCLUSIONS: This expert-based Delphi consensus document provides guidance for clinicians regarding specific unresolved issues. Consensus could not be achieved on some topics, highlighting the need for further research in those areas.
RESUMO
OBJECTIVE: The aim of this study was to evaluate the effect of fenestration configuration and fenestration gap on renal artery outcomes during fenestrated-branched endovascular aortic repair (F/BEVAR). METHODS: A retrospective multicenter analysis was performed, including patients with complex aortic aneurysms treated with F/BEVAR that incorporated at least one small fenestration to a renal artery. The renal fenestrations were divided into groups 1 (8 × 6 mm) and 2 (6 × 6 mm). Primary patency, target vessel instability (TVI), freedom from secondary interventions (SIs), occurrence of type IIIc endoleak, all related to the renal arteries, were analyzed at 30-day, 1-year, and 5-year landmarks. The fenestration gap (FG) distance was analyzed as a modifier, and clustering was addressed at the patient level. RESULTS: A total of 796 patients were included in this study, 71.7% male, with a mean age of 73.3 ± 8.1 years. The mean follow-up was 30.0 ± 20.6 months. Of the 1474 small renal fenestrations analyzed, 47.6% were 8 × 6 mm, and 52.4% were 6 × 6 mm. At the 30-day landmark, primary patency (99.9% vs 98.0%; P value < .001 for groups 1 and 2, respectively), freedom from TVI (99.6% vs 97.1%; P value < .001 for groups 1 and 2, respectively), and freedom from SI (99.8% vs 98.4%; P value = .022 for groups 1 and 2, respectively) were higher in 8 × 6 compared with 6 × 6 fenestrations, and the incidence of acute kidney injury was similar across the groups (92.6% vs 92.7%; P value = .953 for groups 1 and 2 respectively). The primary patency at 1 and 5 years was higher in 8 × 6 fenestrations (1-year: 98.8% vs 96.9%; 5-year: 97.8% vs 95.7%, for groups 1 and 2, respectively, P values = .010 and .021 for 1 and 5 year comparisons, respectively). The freedom from SIs was significantly higher among 6 × 6 fenestrations at 5 years (93.1% vs 96.4%, for groups 1 and 2, respectively, P value = .007). The groups were equally as likely to experience a type Ic endoleak (1.3% and 1.6% for 8 × 6 and 6 × 6mm fenestrations, respectively, P = .689). The 6 × 6 fenestrations were associated with higher risk of kidney function deterioration (17.8%) when compared with 8 × 6 fenestrations (7.6%) at 5 years (P < .001). The risk of type IIIc endoleak was significantly higher among 8 × 6 fenestrations at 5 years (4.9% and 2% for 8 × 6 and 6 × 6 mm fenestrations, respectively; P = .005). A FG ≥5 mm negatively impacted the cumulative 5-year freedom from TVI (group 1: FG ≥5 mm = 0.714, FG <5 mm = 0.857; P < .001; group 2: FG ≥5 mm = 0.761, FG <5 mm = 0.929; P < .001) and the cumulative 5-year freedom from type IIIc endoleak (group 1: FG ≥5 mm = 0.759, FG <5 mm = 0.921; P = .034; group 2: FG ≥5 mm = 0.853, FG <5 mm = 0.979; P < .001) in both groups and the cumulative 5-year patency in group 2 (group 1: FG ≥5 mm = 0.963, FG <5 mm = 0.948; P = .572; group 2: FG ≥5 mm = 0.905, FG <5 mm = 0.938; P = .036). CONCLUSIONS: Fenestration configuration for the renal arteries impacts outcomes. The 8 × 6 small fenestrations have better patency at 30 days, 1 year, and 5 years, whereas 6 × 6 small fenestrations are associated with lower rates of SIs, primarily due to a lower incidence of type IIIc endoleaks. FG ≥5 mm at the level of the renal arteries significantly impacts the freedom from TVI, freedom from type IIIc endoleak, and 5-year patency independently of the fenestration size or vessel diameter.
Assuntos
Implante de Prótese Vascular , Prótese Vascular , Procedimentos Endovasculares , Desenho de Prótese , Artéria Renal , Grau de Desobstrução Vascular , Humanos , Masculino , Estudos Retrospectivos , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Feminino , Idoso , Artéria Renal/cirurgia , Artéria Renal/diagnóstico por imagem , Artéria Renal/fisiopatologia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Fatores de Tempo , Idoso de 80 Anos ou mais , Fatores de Risco , Endoleak/etiologia , Endoleak/prevenção & controle , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/fisiopatologia , Resultado do Tratamento , Stents , Medição de Risco , Correção Endovascular de AneurismaRESUMO
OBJECTIVE: Numerous articles have reported an increased incidence of limb graft occlusion (LGO) with the Cook Zenith Alpha endograft compared with other endografts in endovascular aortic aneurysm repair (EVAR). The present study aimed to assess the rate of LGO after EVAR in particular with the Cook Zenith Alpha device when adhering to a standardised protocol designed to prevent limb related complications. METHODS: This was a non-sponsored retrospective study performed in two university vascular surgery centres employing the same protocol for limb complication prevention during EVAR from 2016 to 2019. The protocol encompassed: (1) angioplasty of any common or external iliac artery with > 50% stenosis before endograft navigation; (2) proximal sealing zone of limbs at the same level of the flow divider with minimum overlap, which is more restrictive than the Cook Zenith Alpha instructions for use; (3) semi-compliant kissing ballooning of limbs; (4) limb stenting for any residual tortuosity, kinking, or stenosis; and (5) adjunctive common and external iliac stenting for residual stenosis or dissection after EVAR. Patients enrolled in this study were treated with standard aortobi-iliac EVAR. Follow up was performed by clinical visit and duplex ultrasonography at discharge, six months, and yearly thereafter. The primary endpoint was to evaluate the LGO rate with different EVAR devices (Cook Zenith Alpha, Gore C3, and Medtronic Endurant) and to determine potential risk factors for LGO associated with the Zenith Alpha. RESULTS: In the study period, 547 EVARs were considered: 233 (42.6%) Cook Zenith Alpha, 196 (35.8%) Gore Excluder, and 118 (21.6%) Medtronic Endurant. The mean follow up was 44 ± 23 months, and the five year freedom from LGO was 97 ± 3%, without differences between groups (97 ± 2%, 95 ± 3%, and 100% with Cook Zenith Alpha, Medtronic Endurant, and Gore Excluder, respectively; p = .080). In the Zenith Alpha group, intra-operative adjunctive iliac artery angioplasty, iliac artery stenting, or iliac limb stenting was performed in 8%, 3.4%, and 9.7% of cases, respectively. Analysis of potential risk factors for LGO identified external iliac artery distal landing and large main bodies (ZIMB 32 - 36) to be independently associated with LGO during follow up (hazard ratio [HR] 18, 95% confidence interval [CI] 3 - 130, p = .004; and HR 12, 95% CI 1.2 - 130, p = .030, respectively). CONCLUSION: The present experience with a protocol for limb complication prevention allows achievement of a low rate of LGO at five years with Zenith Alpha endografts similar to other endografts. Specific risk factors for the Cook Zenith Alpha endograft are external iliac artery distal landing and the use of a large main body (ZIMB 32 - 36).
RESUMO
OBJECTIVES: To investigate the impact of 1-year changes in aneurysm sac diameter on patient survival after fenestrated-branched endovascular aortic repair (FB-EVAR) of complex abdominal aortic aneurysms or thoracoabdominal aortic aneurysms. METHODS: We reviewed the clinical data of patients enrolled in a prospective nonrandomized study investigating FB-EVAR (2013-2022). Patients with sequential follow up computed tomography scans at baseline and 6 to 18 months after FB-EVAR were included in the analysis. Aneurysm sac diameter change was defined as the difference in maximum aortic diameter from baseline measurements obtained in centerline of flow. Patients were classified as those with sac shrinkage (≥5 mm) or failure to regress (<5 mm or expansion) according to sac diameter change. The primary end point was all-cause mortality. Secondary end points were aortic-related mortality (ARM), aortic aneurysm rupture (AAR), and aorta-related secondary intervention. RESULTS: There were 549 patients treated by FB-EVAR. Of these, 463 patients (71% male, mean age, 74 ± 8 years) with sequential computed tomography imaging were investigated. Aneurysm extent was thoracoabdominal aortic aneurysms in 328 patients (71%) and abdominal aortic aneurysms in 135 (29%). Sac shrinkage occurred in 270 patients (58%) and failure to regress in 193 patients (42%), including 19 patients (4%) with sac expansion at 1 year. Patients from both groups had similar cardiovascular risk factors, except for younger age among patients with sac shrinkage (73 ± 8 years vs 75 ± 8 years; P < .001). The median follow-up was 38 months (interquartile range, 18-51 months). The 5-year survival estimate was 69% ± 4.1% for the sac shrinkage group and 46% ± 6.2% for the failure to regress group. Survival estimates adjusted for confounders (age, chronic pulmonary obstructive disease, chronic kidney disease, congestive heart failure, and aneurysm extent) revealed a higher hazard of late mortality in patients with failure to regress (adjusted hazard ratio, 1.72; 95% confidence interval, 1.18-2.52; P = .005). The 5-year cumulative incidences of ARM (1.1% vs 3.1%; P = .30), AAR (0.6% vs 2.6%; P = .20), and aorta-related secondary intervention (17.0% ± 2.8% vs 19.0% ± 3.8%) were both comparable between the groups. CONCLUSIONS: Aneurysm sac shrinkage at 1 year is common after FB-EVAR and is associated with improved patient survival, whereas sac enlargement affects only a minority of patients. The low incidences of ARM and AAR indicate that failure to regress may serve as a surrogate marker for nonaortic-related death.
Assuntos
Aneurisma da Aorta Abdominal , Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Masculino , Feminino , Idoso , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/mortalidade , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Procedimentos Endovasculares/instrumentação , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/mortalidade , Aneurisma da Aorta Torácica/diagnóstico por imagem , Fatores de Tempo , Idoso de 80 Anos ou mais , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Implante de Prótese Vascular/instrumentação , Fatores de Risco , Resultado do Tratamento , Prótese Vascular , Desenho de Prótese , Estudos Prospectivos , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/etiologia , Angiografia por Tomografia Computadorizada , Aortografia/métodos , Estudos Retrospectivos , Medição de Risco , Correção Endovascular de AneurismaRESUMO
OBJECTIVE: The management of cervical artery dissections (CADs) is poorly standardized given the scarce number of prospective studies comparing medical and interventional approach to CAD. The aim of the present study is to perform a systematic review and meta-analysis of studies on the treatments of CAD. METHODS: Systematic review and meta-analysis (pre-registered on PROSPERO [CRD42022297512] are performed according to the Preferred Reporting Items for Systematic reviews and Meta-Analyses [PRISMA] guidelines searching in three different databases [PubMed, Embase and Cochrane Database]) of studies on medical or interventional approach to CAD. Only prospective studies were selected to reduce the risk of bias for the primary meta-analysis. Secondarily, retrospective studies were also included. The aim was to assess the rate of stroke and of stroke/death/bleeding (major or intracranial) by Der Simonian-Laird weights of random effects model. RESULTS: After screening 456 articles, 6 prospective and 22 retrospective studies were identified. Two randomized controlled trials and five retrospective studies comparing antiplatelet (APT) vs oral anticoagulant therapy (OAC) for CAD were identified, as well as four prospective and 17 retrospective single-arm studies evaluating stenting for CAD. In the meta-analysis of randomized controlled trials comparing APT vs OAC, 444 patients were considered, and a borderline significant association was identified in terms of stroke/death in the APT vs OAC groups (odds ratio [OR], 5.6; 95% confidence interval [CI], 0.94-33.38; P = .06; I2 = 0%). No differences were found for the stroke/death/bleeding outcome (OR, 1.25; 95% CI, 0.19-8.18; P = .81; I2 = 0%) between the two treatments. In the meta-analysis including also retrospective studies, overall risk of bias was considered "serious," and 4104 patients were included with no differences in APT vs OAC for stroke (OR, 1.06; 95% CI, 0.53-2.11; P = .29; I2 = 18%); no other comparisons were possible. The pooled meta-analysis of prospective studies on stenting for CAD included four series, for a total of 68 patients, in whom stenting was adopted primarily after failed medical therapy or after traumatic dissection. The pooled rate of stroke/death was 7% (95% CI, 3%-17%; I2 = 0%). The analysis of moderators identified a significant inverse association between the percentage of traumatic dissection and a reduction in postoperative stroke (Y = -1.60-2.02X; P = .03). The pooled rate of the composite endpoint of stroke/death/ or major bleeding was 8% (95% CI, 3%-18%; I2 = 0%). Secondarily, the meta-analysis also included 17 retrospective studies with overall 457 patients and showed a 2.1% pooled rate of stroke/death (95% CI, 1.0%-3.3%; I2 = 0%) and 3.2% stroke/death/bleeding (95% CI, 1.8%-4.7%; I2 = 0%). CONCLUSIONS: Few prospective studies on CAD treatment are present in literature. APT and OAC seem to have similar efficacy in reducing the recurrence of stroke after CAD. No definitive conclusion can be drawn for stenting, due to the low number of studies available. More prospective studies are necessary to evaluate its potential additional value over medical therapy alone in the early phase after CAD.
Assuntos
Anticoagulantes , Procedimentos Endovasculares , Inibidores da Agregação Plaquetária , Stents , Acidente Vascular Cerebral , Humanos , Anticoagulantes/uso terapêutico , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Procedimentos Endovasculares/instrumentação , Inibidores da Agregação Plaquetária/uso terapêutico , Medição de Risco , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento , Dissecação da Artéria Vertebral/terapia , Dissecação da Artéria Vertebral/mortalidade , Dissecação da Artéria Vertebral/diagnóstico por imagemRESUMO
OBJECTIVE: To analyze the outcomes of urgent/emergent endovascular aortic repair of patients with free/contained ruptured thoracoabdominal aortic aneurysms (rTAAA). BACKGROUND: Endovascular repair of rTAAA has been scarcely described in emergent setting. METHODS: An international multicenter retrospective observational study (ClinicalTrials.govID:NCT05956873) from January-2015 to January-2023 in 6 European and 1 United States Vascular Surgery Centers. Primary end-points were technical success, 30-day and/or in-hospital mortality and follow-up survival. RESULTS: A total of 100 rTAAA patients were included (75 male; mean age 73 y). All patients (86 contained and 14 free ruptures) were symptomatic and treated within 24-hours from diagnosis: multi-branched off-the-shelf devices (Zenith t-branch,Cook Medical Inc.Bjaeverskov,Denmark) in 88 patients, physician-modified endografts in 8, patient-specific device or parallel grafts in two patients each. Primary technical success was achieved in 89 patients and 30-day and/or in-hospital mortality was 24%. Major adverse events (MAEs) occurred in 34% of patients (permanent dialysis and paraplegia in 4 and 8 patients, respectively). No statistical differences were detected in mortality rates between free and contained ruptured patients (43%vs.21%; P =0.075). Multivariate analysis revealed contained rupture favoring technical success (Odd-Ratio10.1;95%Confidence-Interval:3.0-33.6; P =<0.001). MAEs (OR9.4;95%C-I:2.8-30.5; P =<0.001) and pulmonary complications (OR11.3;95%CI:3.0-41.5; P =<0.001) were independent risk factors for 30-day and/or in-hospital mortality. Median follow-up time was 13 months (interquartile range 5-24); 1-year survival rate was 65%. Aneurysm diameter>80 mm (Hazard-Ratio:2.0;95%CI:1.0-30.5; P =0.037), technical failure (HR:2.6;95%CI:1.1-6.5; P =0.045) and pulmonary complications (HR:3.0;95%CI:1.2-7.9; P =0.021) were independent risk factors for follow-up mortality. CONCLUSION: Endovascular repair of rTAAA shows high technical success; the presence of free rupture alone appear not to correlate with early mortality. Effective prevention/management of post-operative complications is crucial for survival.
RESUMO
This manuscript is intended to provide a comprehensive review of the current state of knowledge on endovascular repair of thoracoabdominal aortic aneurysms (TAAAs). The management of these complex aneurysms requires an interdisciplinary and patient-specific approach in high-volume centers. An index case is used to discuss the diagnosis and treatment of a patient undergoing fenestrated-branched endovascular aneurysm repair for a TAAA.
Assuntos
Aneurisma da Aorta Abdominal , Aneurisma da Aorta Torácica , Aneurisma da Aorta Toracoabdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Prótese Vascular , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Resultado do Tratamento , Fatores de Risco , Desenho de Prótese , Complicações Pós-OperatóriasRESUMO
OBJECTIVE: Total transfemoral (TF) access has been increasingly used during fenestrated-branched endovascular aortic repair (FB-EVAR). However, it is unclear whether the potential decrease in the risk of cerebrovascular events is offset by increased procedural difficulties and other complications. The aim of this study was to compare outcomes of FB-EVAR using a TF vs upper extremity (UE) approach for target artery incorporation. METHODS: We analyzed the clinical data of consecutive patients enrolled in a prospective, nonrandomized clinical trial in two centers to investigate the use of FB-EVAR for treatment of complex abdominal aortic aneurysms (CAAA) and thoracoabdominal aortic aneurysms (TAAA) between 2013 and 2022. Patients were classified into TF or UE access group with a subset analysis of patients treated using designs with directional branches. End points were technical success, procedural metrics, 30-day cerebrovascular events defined as stroke or transient ischemic attack, and any major adverse events (MAEs). RESULTS: There were 541 patients (70% males; mean age, 74 ± 8 years) treated by FB-EVAR with 2107 renal-mesenteric TAs incorporated. TF was used in175 patients (32%) and UE in 366 patients (68%) including 146 (83%) TF and 314 (86%) UE access patients who had four or more TAs incorporated. The use of a TF approach increased from 8% between 2013 and 2017 to 31% between 2018 and 2020 and 96% between 2021 and 2022. Compared with UE access patients, TF access patients were more likely to have CAAAs (37% vs 24%; P = .002) as opposed to TAAAs. Technical success rate was 96% in both groups (P = .96). The use of the TF approach was associated with reduced fluoroscopy time and procedural time (each P < .05). The 30-day mortality rate was 0.6% for TF and 1.4% for UE (P = .67). There was no early cerebrovascular event in the TF group, but the incidence was 2.7% for UE patients (P = .035). The incidence of MAEs was also lower in the TF group (9% vs 18%; P = .006). Among 237 patients treated using devices with directional branches, there were no significant differences in outcomes except for a reduced procedural time for TF compared with UE access patients (P < .001). CONCLUSIONS: TF access was associated with a decreased incidence of early cerebrovascular events and MAEs compared with UE access for target artery incorporation. Procedural time was decreased in TF access patients irrespective of the type of stent graft design.
Assuntos
Aneurisma da Aorta Abdominal , Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Masculino , Humanos , Idoso , Idoso de 80 Anos ou mais , Feminino , Prótese Vascular , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/etiologia , Fatores de Risco , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/etiologia , Extremidade Superior , Resultado do Tratamento , Estudos RetrospectivosRESUMO
We describe a case of an abdominal aortic aneurysm (AAA) and angulated proximal neck treated with a Gore Excluder conformable endoprosthesis and show relevant technical pitfalls in the deployment of the graft main body. An 82-year-old man presented with a 71-mm asymptomatic AAA with an angulated infrarenal proximal neck (75°) and was referred to our unit. The patient was treated with a 26-mm Gore Excluder conformable device, which was deployed slightly above the renal arteries after precatheterization of the lowest renal artery. The graft was then repositioned with support of the introducer sheath and a stiff guide wire. The proximal sealing zone was ballooned before the endograft delivery system was retrieved to avoid distal migration. Technical success was achieved. The patient was discharged with no complications. No type Ia endoleak was present on the 6-month computed tomography scan. Endovascular treatment of an AAA with a severe angulated proximal neck can be effective with a conformable stent graft if technical measures are used during deployment of the main body to optimize the seal.
RESUMO
BACKGROUND: Popliteal artery aneurysms (PAAs) need urgent treatment in case of acute thrombosis, distal embolization, or rupture. Few data are available in the literature about the treatment results in these scenarios. The aim of the present study was to evaluate an 11-year multicenter experience in the urgent treatment of PAAs. METHODS: All symptomatic PAAs surgically treated in two vascular centers between 2010 and 2021 were retrospectively analyzed. In the postoperative period periodical clinical and Duplex-Ultrasound evaluation were performed. The evaluated endpoint was the outcome of urgent PAAs treatment according to their clinical presentation. Statistical analysis was performed by Kaplan-Meier log-rank evaluation and multivariable Cox regression tests. RESULTS: Sixty-six PAAs needed an urgent repair. Twelve (18%) patients had a PAA rupture and 54 (82%) had an acute limb ischemia (ALI) due to either distal embolization or acute thrombosis. Patients with ALI underwent bypass surgery in 51 (95%) cases, which was associated with preoperative thrombolysis in 18 (31%) cases. A primary major amputation was performed in 3 (5%) cases. The mean follow-up was 52 ± 21 months with an overall 5-year limb salvage of 83 ± 6%. Limb salvage was influenced only by the number of patent tibial arteries (pTA) [5-years limb salvage 0%, 86 ± 10%, 92 ± 8% and 100% in case of 0, 1, 2 or 3 pTA, respectively (P = .001)]. An independent association of number of pTA and limb loss was found [hazard ratio (HR): 0.14 (95% confidence interval (CI) 0.03-0.6), P = .001]. Overall 5-year survival was 71 ± 7%. Ruptured PAAs were associated with lower 5-year survival compared with the ALI group (48 ± 2% vs. 79 ± 7%, P = .001). The number of pTA (33 ± 20%, 65 ± 10%, 84 ± 10% and 80 ± 10% for 0, 1, 2 and 3 pTA, respectively, P = .001) and the thrombolysis (94 ± 6% vs. 62 ± 10%, P = .03) were associated with higher survival in patients with ALI. There was an independent association of number of pTA and long-term survival [HR 0.15 (95% CI 0.03-0.8), P = .03]. CONCLUSIONS: PAA rupture is the cause of urgent PAA treatment in almost one fifth of cases, and it is associated with lower long-term survival. ALI can benefit from thrombolysis, and long-term limb salvage and survival are associated with the number of pTA.
Assuntos
Aneurisma , Aneurisma da Artéria Poplítea , Trombose , Humanos , Salvamento de Membro/efeitos adversos , Estudos Retrospectivos , Aneurisma/cirurgia , Aneurisma/complicações , Trombose/etiologia , Isquemia/etiologiaRESUMO
CO
Assuntos
Falso Aneurisma , Procedimentos Endovasculares , Iodo , Feminino , Humanos , Adulto , Dióxido de Carbono , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/cirurgia , Ílio , Angiografia , Meios de Contraste , Aorta Abdominal , Procedimentos Endovasculares/efeitos adversos , Resultado do Tratamento , Artéria Ilíaca/diagnóstico por imagem , Artéria Ilíaca/cirurgiaRESUMO
OBJECTIVE: Stenting of renal and mesenteric vessels may result in changes in velocity measurements due to arterial compliance, potentially giving rise to confusion about the presence of stenosis during follow-up. The aim of our study was to compare preoperative and postoperative changes in peak systolic velocity (PSV, cm/s) after placement of the celiac axis (CA), superior mesenteric artery (SMA) and renal artery (RAs) bridging stent grafts during fenestrated-branched endovascular aortic repair (FB-EVAR) for treatment of complex abdominal aortic aneurysms (AAA) and thoracoabdominal aortic aneurysms. METHODS: Patients were enrolled in a prospective, nonrandomized single-center study to evaluate FB-EVAR for treatment of complex AAA and thoracoabdominal aortic aneurysms between 2013 and 2020. Duplex ultrasound examination of renal-mesenteric vessels were obtained prospectively preoperatively and at 6 to 8 weeks after the procedure. Duplex ultrasound examination was performed by a single vascular laboratory team using a predefined protocol including PSV measurements obtained with <60° angles. All renal-mesenteric vessels incorporated by bridging stent grafts using fenestrations or directional branches were analyzed. Target vessels with significant stenosis in the preoperative exam were excluded from the analysis. The end point was variations in PSV poststent placement at the origin, proximal, and mid segments of the target vessels for fenestrations and branches. RESULTS: There were 419 patients (292 male; mean age, 74 ± 8 years) treated by FB-EVAR with 1411 renal-mesenteric targeted vessels, including 260 CAs, 409 SMAs, and 742 RAs. No significant variances in the mean PSVs of all segments of the CA, SMA, and RAs at 6 to 8 weeks after surgery were found as compared with the preoperative values (CA, 135 cm/s vs 141 cm/s [P = .06]; SMA, 128 cm/s vs 125 cm/s [P = .62]; RAs, 90 cm/s vs 83 cm/s [P = .65]). Compared with baseline preoperative values, the PSV of the targeted vessels showed no significant differences in the origin and proximal segment of all vessels. However, the PSV increased significantly in the mid segment of all target vessels after stent placement. CONCLUSIONS: Stent placement in nonstenotic renal and mesenteric vessels during FB-EVAR is not associated with a significant increase in PSVs at the origin and proximal segments of the target vessels. Although there is a modest but significant increase in velocity measurements in the mid segment of the stented vessel, this difference is not clinically significant. Furthermore, PSVs in stented renal and mesenteric arteries were well below the threshold for significant stenosis in native vessels. These values provide a baseline or benchmark for expected PSVs after renal-mesenteric stenting during FB-EVAR.
RESUMO
OBJECTIVE: To describe outcomes after elective and non-elective fenestrated-branched endovascular aortic repair (FB-EVAR) for thoracoabdominal aortic aneurysms (TAAAs). BACKGROUND: FB-EVAR has been increasingly utilized to treat TAAAs; however, outcomes after non-elective versus elective repair are not well described. METHODS: Clinical data of consecutive patients undergoing FB-EVAR for TAAAs at 24 centers (2006-2021) were reviewed. Endpoints including early mortality and major adverse events (MAEs), all-cause mortality, and aortic-related mortality (ARM), were analyzed and compared in patients who had non-elective versus elective repair. RESULTS: A total of 2603 patients (69% males; mean age 72±10 year old) underwent FB-EVAR for TAAAs. Elective repair was performed in 2187 patients (84%) and non-elective repair in 416 patients [16%; 268 (64%) symptomatic, 148 (36%) ruptured]. Non-elective FB-EVAR was associated with higher early mortality (17% vs 5%, P <0.001) and rates of MAEs (34% vs 20%, P <0.001). Median follow-up was 15 months (interquartile range, 7-37 months). Survival and cumulative incidence of ARM at 3 years were both lower for non-elective versus elective patients (50±4% vs 70±1% and 21±3% vs 7±1%, P <0.001). On multivariable analysis, non-elective repair was associated with increased risk of all-cause mortality (hazard ratio, 1.92; 95% CI] 1.50-2.44; P <0.001) and ARM (hazard ratio, 2.43; 95% CI, 1.63-3.62; P <0.001). CONCLUSIONS: Non-elective FB-EVAR of symptomatic or ruptured TAAAs is feasible, but carries higher incidence of early MAEs and increased all-cause mortality and ARM than elective repair. Long-term follow-up is warranted to justify the treatment.
Assuntos
Aneurisma da Aorta Abdominal , Aneurisma da Aorta Torácica , Aneurisma da Aorta Toracoabdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Feminino , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Correção Endovascular de Aneurisma , Implante de Prótese Vascular/efeitos adversos , Resultado do Tratamento , Fatores de Risco , Procedimentos Endovasculares/efeitos adversos , Fatores de Tempo , Estudos Retrospectivos , Prótese VascularRESUMO
This study aimed to provide a comprehensive overview of the most common intraoperative adverse events that occur during standard endovascular repair and fenestrated-branched endovascular repair to treat abdominal aortic aneurysms, thoracoabdominal aortic aneurysms, and aortic arch aneurysms. Despite advancements in endovascular techniques, sophisticated imaging and improved graft designs, intraoperative difficulties still occur, even in highly standardized procedures and high-volume centers. This study emphasized that with the increased adoption and complexity of endovascular aortic procedures, strategies to minimize intraoperative adverse events should be protocolized and standardized. There is a need for robust evidence on this topic, which could potentially optimize treatment outcomes and durability of the available techniques.
Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Prótese Vascular/efeitos adversos , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Correção Endovascular de Aneurisma , Stents/efeitos adversos , Fatores de Risco , Desenho de Prótese , Complicações Pós-Operatórias/etiologia , Fatores de Tempo , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Complicações Intraoperatórias/etiologia , Complicações Intraoperatórias/cirurgiaRESUMO
OBJECTIVE: The aim of this study was to compare outcomes of fenestrated-branched endovascular aortic repair (FB-EVAR) of complex abdominal (CAAAs) and thoracoabdominal aortic aneurysms (TAAAs) in patients with or without prior history of abdominal open surgical (OSR) or endovascular aortic repair (EVAR). METHODS: The clinical data of consecutive patients enrolled in a prospective, non-randomized study to evaluate FB-EVAR for treatment of CAAAs and TAAAs was reviewed. Clinical outcomes were analyzed in patients with no previous aortic repair (Controls), prior EVAR (Group 1), and prior abdominal OSR (Group 2), including 30-day mortality and major adverse events (MAEs), patient survival and freedom from aortic-related mortality (ARM), secondary interventions, any type II endoleak, sac enlargement (≥5 mm), and new-onset permanent dialysis. RESULTS: There were 506 patients (69% male; mean age, 72 ± 9 years) treated by FB-EVAR, including 380 controls, 54 patients in Group 1 (EVAR), and 72 patients in Group 2 (abdominal OSR). FB-EVAR was performed on average 7 ± 4 and 12 ± 6 years after the index EVAR and abdominal OSR, respectively (P < .001). All three groups had similar clinical characteristics, except for less coronary artery disease in controls and more TAAAs and branch stent graft designs in Group 2 (P < .05). Aneurysm extent was CAAA in 144 patients (28%) and TAAA in 362 patients (72%). Overall technical success, mortality, and MAE rate were 96%, 1%, and 14%, respectively, with no difference between groups. Mean follow up was 30 ± 21 months. Patient survival was significantly lower in Group 2 (P = .03), but there was no difference in freedom from ARM and secondary interventions at 5 years between groups. Group 1 patients had lower freedom from any type II endoleak (P = .02) and sac enlargement (P < .001), whereas Group 2 patients had lower freedom from new-onset permanent dialysis (P = .03). CONCLUSIONS: FB-EVAR was performed with high technical success, low mortality, and similar risk of MAEs, regardless of prior history of abdominal aortic repair. Patient survival was significantly lower in patients who had previous abdominal OSR, but freedom from ARM and secondary interventions were similar among groups. Patients with prior EVAR had lower freedom from type II endoleak and sac enlargement. Patients with prior OSR had lower freedom from new-onset dialysis.
Assuntos
Aneurisma da Aorta Abdominal , Aneurisma da Aorta Torácica , Aneurisma da Aorta Toracoabdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Feminino , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/etiologia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/etiologia , Correção Endovascular de Aneurisma , Endoleak/etiologia , Endoleak/cirurgia , Estudos Prospectivos , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/terapia , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Fatores de Risco , Estudos RetrospectivosRESUMO
OBJECTIVE: Chronic limb threatening ischaemia (CLTI) involving the infragenicular arteries is treated by distal angioplasty or pedal bypass; however, this is not always possible, due to chronically occluded pedal arteries (no patent pedal artery, N-PPA). This pattern represents a hurdle to successful revascularisation, which must be limited to the proximal arteries. The aim of the study was to analyse the outcome of patients with CLTI and N-PPA after a proximal revascularisation. METHODS: All patients with CLTI submitted to revascularisation in a single centre (2019 - 2020) were analysed. All angiograms were reviewed to identify N-PPA, defined as total obstruction of all pedal arteries. Revascularisation was performed with proximal surgical, endovascular, and hybrid procedures. Early and midterm survival, wound healing, limb salvage, and patency rates were compared between N-PPA and patients with one or more patent pedal artery (PPA). RESULTS: Two hundred and eighteen procedures were performed. One hundred and forty of 218 (64.2%) patients were male, mean age 73.2 ± 10.6 years. The procedure was surgical in 64/218 (29.4%) cases, endovascular in 138/218 (63.3%), and hybrid in 16/218 (7.3%). N-PPA was present in 60/218 (27.5%) cases. Eleven of 60 (18.3%) cases were treated surgically, 43/60 (71.7%) by endovascular and 6/60 (10%) by hybrid procedures. Technical success was similar in the two groups (N-PPA 85% vs. PPA 82.3%, p = .42). At a mean follow up of 24.5 ± 10.2 months, survival (N-PPA 93.7 ± 3.5% vs. PPA 95.3 ± 2.1%, p = .22) and primary patency (N-PPA 53.1 ± 8.1% vs. PPA 55.2 ± 5%, p = .56) were similar. Limb salvage was significantly lower in N-PPA patients (N-PPA 71.4 ± 6.6% vs. PPA 81.5 ± 3.4%, p = .042); N-PPA was an independent predictor of major amputation (hazard ratio [HR] 2.02, 1.07 - 3.82, p = .038) together with age > 73 years (HR 2.32, 1.17 - 4.57, p = .012) and haemodialysis (2.84, 1.48 - 5.43, p = .002). CONCLUSION: N-PPA is not uncommon in patients with CLTI. This condition does not hamper technical success, primary patency, and midterm survival; however, midterm limb salvage is significantly lower than in patients with PPA. This should be considered in the decision making process.
Assuntos
Procedimentos Endovasculares , Doença Arterial Periférica , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Feminino , Salvamento de Membro/métodos , Isquemia Crônica Crítica de Membro , Resultado do Tratamento , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/cirurgia , Doença Arterial Periférica/etiologia , Isquemia/diagnóstico por imagem , Isquemia/etiologia , Isquemia/cirurgia , Artéria Poplítea/cirurgia , Fatores de Risco , Estudos Retrospectivos , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Grau de Desobstrução VascularRESUMO
BACKGROUND AND OBJECTIVES: Endovascular aneurism repair (EVAR) is a minimally invasive alternative to open surgery for the treatment of abdominal aortic aneurysm. Iodine contrast medium (ICM) is considered the gold standard, at the high price of related nephrotoxicity and allergic reactions. Carbon dioxide (CO2) has been suggested as an alternative non-nephrotoxic contrast media agent. We aimed to evaluate the safety and the renal impact of the administration of CO2, compared with ICM in EVAR procedures. DESIGN, SETTING, PARTICIPANTS, AND MEASUREMENTS: We retrospectively reviewed data of patients who underwent EVAR at the Vascular Surgery Department of the Sant'Orsola Hospital in Bologna. Estimated glomerular filtration rate (eGFR) was evaluated before intervention, immediately after and at 12 months. RESULTS: In total, 22 patients received CO2 and low-dose ICM (CO2 Group) and 22 received standard ICM (Control Group), matched for clinical characteristics and renal function at the time of procedure. Pre and post-operative renal function values (eGFR) were compared between the two groups: in the immediate post-operative the group treated with CO2 and low-dose ICM globally showed a slight improvement in renal function (mean eGFR +5.10%±3.2), meanwhile the group treated with standard dose of ICM presented a significant worsening of renal function compared with pre-procedure values (mean eGFR -9.65%±4). Incidence of post-contrast acute kidney injury (PC-AKI) was 9% in the CO2 group vs 27% in the Control group. At 12 months, the renal impairment was significantly greater in the ICM group than in the CO2 group (mean eGFR decrease -19.2%±11.1 and -7.40%±3.5, respectively). CONCLUSIONS: Administration of either CO2 alone or along with low-dose ICM showed to be safer than full-dose ICM alone, lowering the incidence of PC-AKI in patients undergoing EVAR. Unexpectedly, our study revealed also a significant worsening of renal function in patients treated with standard dose of ICM in 1-year follow-up, introducing the concept that acute renal damage caused by ICM could elicit a chronic injury process that affect long-term renal outcomes. CLINICAL IMPACT: Evaluating the safety and the renal impact of the administration of CO2, compared to Iodinate Contrast Medium, in EVAR procedures represents a first step in order to further tayloring medical procedures on patients characteristics. Our findings can guide the clinicians and surgeons in the procedures choice, not considering only the immediate effect of ICM on renal function but also the potential long-term effects.
RESUMO
OBJECTIVE: The aim of this study was to compare outcomes of single or multistage approach during fenestrated-branched endovascular aortic repair (FB-EVAR) of extensive thoracoabdominal aortic aneurysms (TAAAs). METHODS: We reviewed the clinical data of consecutive patients treated by FB-EVAR for extent I to III TAAAs in 24 centers (2006-2021). All patients received a single brand manufactured patient-specific or off-the-shelf fenestrated-branched stent grafts. Staging strategies included proximal thoracic aortic repair, minimally invasive segmental artery coil embolization, temporary aneurysm sac perfusion and combinations of these techniques. Endpoints were analyzed for elective repair in patients who had a single- or multistage approach before and after propensity score adjustment for baseline differences, including the composite 30-day/in-hospital mortality and/or permanent paraplegia, major adverse event, patient survival, and freedom from aortic-related mortality. RESULTS: A total of 1947 patients (65% male; mean age, 71 ± 8 years) underwent FB-EVAR of 155 extent I (10%), 729 extent II (46%), and 713 extent III TAAAs (44%). A single-stage approach was used in 939 patients (48%) and a multistage approach in 1008 patients (52%). A multistage approach was more frequently used in patients undergoing elective compared with non-elective repair (55% vs 35%; P < .001). Staging strategies were proximal thoracic aortic repair in 743 patients (74%), temporary aneurysm sac perfusion in 128 (13%), minimally invasive segmental artery coil embolization in 10 (1%), and combinations in 127 (12%). Among patients undergoing elective repair (n = 1597), the composite endpoint of 30-day/in-hospital mortality and/or permanent paraplegia rate occurred in 14% of single-stage and 6% of multistage approach patients (P < .001). After adjustment with a propensity score, multistage approach was associated with lower rates of 30-day/in-hospital mortality and/or permanent paraplegia (odds ratio, 0.466; 95% confidence interval, 0.271-0.801; P = .006) and higher patient survival at 1 year (86.9±1.3% vs 79.6±1.7%) and 3 years (72.7±2.1% vs 64.2±2.3%; adjusted hazard ratio, 0.714; 95% confidence interval, 0.528-0.966; P = .029), compared with a single stage approach. CONCLUSIONS: Staging elective FB-EVAR of extent I to III TAAAs was associated with decreased risk of mortality and/or permanent paraplegia at 30 days or within hospital stay, and with higher patient survival at 1 and 3 years.