RESUMO
Sulfated metabolites have shown to have potential as long-term markers (LTMs) of anabolic-androgenic steroid (AAS) abuse. The compatibility of gas chromatography-mass spectrometry (GC-MS) with trimethylsilyl (TMS)-derivatives of non-hydrolysed sulfated steroids has been demonstrated, where, after derivatisation, generally, two closely eluting isomers are formed that both have the same molecular ion [M-H2 SO4 ]â¢+ . Sulfated reference standards are in limited commercial availability, and therefore, the current knowledge of the GC-MS behaviour of these compounds is mainly based on sulfating and analysing the available standard reference material. This procedure can unfortunately not cover all of the current known LTMs as these are often not available as pure substance. Therefore, in theory, some metabolites could be missed as they exhibit alternative behaviour. To investigate the matter, in-house sulfated reference materials that bear resemblance to known sulfated LTMs were analysed on GC-MS in their TMS-derivatised non-hydrolysed state. The (alternative) gas chromatographic and mass spectrometric behaviour was mapped, evaluated and linked to the corresponding steroid structures. Afterwards, using fraction collection, known sulfated LTMs were isolated from excretion urine to confirm the observed findings. The categories that were selected were mono-hydroxy-diones, 17-methyl-3,17-diols and 17-keto-3,16-diols as these are commonly encountered AAS conformations. The ability to predict the GC-MS behaviour of non-hydrolysed sulfated AAS metabolites is the corner stone of finding new metabolites. This knowledge is also essential, for example, for understanding AAS detection analyses, for the mass spectrometric characterization of metabolites of new designer steroids or when one needs to characterize an unknown steroid structure.
Assuntos
Anabolizantes , Dopagem Esportivo , Esteróides Androgênicos Anabolizantes , Anabolizantes/análise , Sulfatos/metabolismo , Congêneres da Testosterona , Esteroides/análise , Detecção do Abuso de Substâncias/métodosRESUMO
The World Anti-Doping Agency (WADA) publishes yearly their prohibited list, and sets a minimum required performance limit for each substance. To comply with these stringent requirements, the anti-doping laboratories have at least two complementary methods for their initial testing procedure (ITP), one using gas chromatography - mass spectrometry (GC-MS) and the other using liquid chromatography-MS (LC-MS). Anabolic androgenic steroids (AAS) have in previous years consistently been listed as the most frequently detected class of compounds. Over the last decade, evidence has emerged where a longer detection time is attained by focusing on sulfated metabolites of AAS instead of the conventional gluco-conjugated metabolites. Despite a decade of research on sulphated AAS using LC-MS, no LC-MS ITP has been developed that combines this class of compounds with the other mandatory targets. Such combination is essential for economical purposes. Recently, it was demonstrated that the direct injection of non-hydrolysed sulfates is compatible with GC-MS. Using this approach and by taking full use of the open screening capabilities of the quadrupole time of flight MS (QTOF-MS), this work describes for the first time a validated ITP that allows the detection of non-hydrolysed sulfated metabolites of AAS while, simultaneously, remaining capable of detecting a vast range of other classes of compounds, as well as the quantification of endogenous steroids, as required for an ITP compliant with the applicable WADA regulations. The method contains 263 compounds from 9 categories, including stimulants, narcotics, anabolic androgenic steroids and beta-blockers. Additionally, the advantages of the new method were illustrated by analysing excretion samples of drostanolone, mesterolone and metenolone. No negative effects were observed for the conventional markers and the detection time for mesterolone and metenolone increased by up to 150% and 144%, respectively compared to conventional markers.
Assuntos
Anabolizantes/análise , Dopagem Esportivo , Cromatografia Gasosa-Espectrometria de Massas/métodos , Programas de Rastreamento , Metaboloma , Esteroides/análise , Adulto , Androstanóis/análise , Humanos , Hidrólise , Limite de Detecção , Masculino , Metenolona/análise , Reprodutibilidade dos Testes , Detecção do Abuso de Substâncias/métodosRESUMO
OBJECTIVE: Men with obesity often have low total and, with increasing adiposity, also low free testosterone (T) levels, which can partially restore during weight loss. Although this is partly explained by lower sex hormone binding globulin (SHBG) production and hypothalamic-pituitary downregulation, it is still not unravelled whether changes in androgen metabolism contribute to this phenomenon. Therefore, early changes in urinary excretion of T and its metabolites, during weight loss, in men with obesity are investigated. DESIGN: Longitudinal study. METHODS: Fourteen men with obesity (age 52(45-60)years, BMI 42.6(41.8-44.8)kg/m²) underwent gastric bypass surgery (GBS). Before surgery and 3 weeks, 6 weeks, 6 months and 1 year thereafter, 24 h urine and fasting serum samples were collected. Serum T and estradiol (E2) levels were analyzed using LC-MS/MS and urinary metabolites of T with GC-MS/MS. RESULTS: Already three weeks after GBS, serum SHBG and total T levels increased and remained increased as compared to baseline (all,p < 0.0125). Gonadotropins and (free) E2 levels were unchanged, serum E2/T ratio decreased (p < 0.0125). Total amount of urinary T increased non-significantly with mean increases of 53 % one year after GBS (p = 0.026). Urinary E2/T, estrone/T, 3α-androstanediol/T and androsterone/T ratios decreased after GBS (p < 0.0125). CONCLUSIONS: Restoration of circulating T levels during weight loss in this population is not only brought about by normalization of circulating SHBG levels, but increased production of and alterations in T metabolism also contribute. More specifically, relative decreases in aromatization and lower 5α-reductase activity might also be involved in restoring T levels in men with obesity.
Assuntos
Hidroxiesteroide Desidrogenases/metabolismo , Obesidade/metabolismo , Globulina de Ligação a Hormônio Sexual/metabolismo , Testosterona/metabolismo , Redução de Peso , Humanos , Hidroxiesteroide Desidrogenases/genética , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Obesidade/patologia , Estudos ProspectivosRESUMO
Sulfated metabolites have been shown to have potential as long-term markers of anabolic-androgenic steroid (AAS) abuse. In 2019, the compatibility of gas chromatography-mass spectrometry (GC-MS) with non-hydrolysed sulfated steroids was demonstrated, and this approach allowed the incorporation of these compounds in a broad GC-MS initial testing procedure at a later stage. However, research is needed to identify which are beneficial. In this study, a search for new long-term metabolites of two popular AAS, metenolone and drostanolone, was undertaken through two excretion studies each. The excretion samples were analysed using GC-chemical ionization-triple quadrupole MS (GC-CI-MS/MS) after the application of three separate sample preparation methodologies (i.e. hydrolysis with Escherichia coli-derived ß-glucuronidase, Helix pomatia-derived ß-glucuronidase/arylsulfatase and non-hydrolysed sulfated steroids). For metenolone, a non-hydrolysed sulfated metabolite, 1ß-methyl-5α-androstan-17-one-3ζ-sulfate, was documented for the first time to provide the longest detection time of up to 17 days. This metabolite increased the detection time by nearly a factor of 2 in comparison with the currently monitored markers for metenolone in a routine doping control initial testing procedure. In the second excretion study, it prolonged the detection window by 25%. In the case of drostanolone, the non-hydrolysed sulfated metabolite with the longest detection time was the sulfated analogue of the main drostanolone metabolite (3α-hydroxy-2α-methyl-5α-androstan-17-one) with a detection time of up to 24 days. However, the currently monitored main drostanolone metabolite in routine doping control, after hydrolysis of the glucuronide with E.coli, remained superior in detection time (i.e. up to 29 days).
Assuntos
Anabolizantes/urina , Androstanóis/urina , Cromatografia Gasosa-Espectrometria de Massas/métodos , Metenolona/urina , Adulto , Anabolizantes/metabolismo , Androstanóis/metabolismo , Dopagem Esportivo/prevenção & controle , Humanos , Masculino , Metenolona/metabolismo , Detecção do Abuso de Substâncias/métodos , Sulfatos/urina , Espectrometria de Massas em Tandem/métodosRESUMO
Steroid detection and identification remain key issues in toxicology, drug testing, medical diagnostics, food safety control, and doping control. In this study, we evaluate the capabilities and usefulness of analyzing non-hydrolyzed sulfated steroids with gas chromatography-mass spectrometry (GC-MS) instead of the conventionally applied liquid chromatography-mass spectrometry (LC-MS) approach. Sulfates of 31 steroids were synthesized and their MS and chromatographic behavior studied by chemical ionization-GC-triple quadrupole MS (CI-GC-TQMS) and low energy-electron ionization-GC-quadrupole time-of-flight-MS (LE-EI-GC-QTOF-MS). The collected data shows that the sulfate group is cleaved off in the injection port of the GC-MS, forming two isomers. In CI, the dominant species (ie, [MH - H2 SO4 ]+ or [MH - H4 S2 O8 ]+ for bis-sulfates) is very abundant due to the limited amount of fragmentation, making it an ideal precursor ion for MS/MS. In LE-EI, [M - H2 SO4 ].+ and/or [M - H2 SO4 - CH3 ].+ are the dominant species in most cases. Based on the common GC-MS behavior of non-hydrolyzed sulfated steroids, two applications were evaluated and compared with the conventionally applied LC-MS approach; (a) discovery of (new) sulfated steroid metabolites of mesterolone and (b) expanding anabolic androgenic steroid abuse detection windows. GC-MS and LC-MS analysis of non-hydrolyzed sulfated steroids offered comparable sensitivities, superseding these of GC-MS after hydrolysis. For non-hydrolyzed sulfated steroids, GC-MS offers a higher structural elucidating power and a more straightforward inclusion in screening methods than LC-MS.
Assuntos
Cromatografia Gasosa-Espectrometria de Massas/métodos , Esteroides/metabolismo , Sulfatos/metabolismo , Adulto , Anabolizantes/metabolismo , Anabolizantes/urina , Humanos , Hidrólise , Masculino , Mesterolona/metabolismo , Mesterolona/urina , Pessoa de Meia-Idade , Esteroides/urina , Detecção do Abuso de Substâncias/métodos , Sulfatos/urina , Espectrometria de Massas em Tandem/métodosRESUMO
In anti-doping, a high number of classes of substances are prohibited and laboratories need to detect these at low urinary concentrations. Traditionally, testing is done using complimentary liquid chromatography mass spectrometry and gas chromatography mass spectrometry. High resolution mass spectrometric acquisition has some important advantages over triple quadrupole instruments (e.g., open screening due to full scan high resolution data acquisition with retrospectivity, compatibility with libraries and a straightforward and effortless addition and validation of new compounds in the future). Doping samples can be stored for 10 years and retrospective data analysis can be used to re-evaluate previously acquired data (e.g., searching for prohibited (designer) substances that were unknown at the initial moment of analysis). During the past decade, these advantages have led to the wide-scale transfer of liquid chromatography triple quadrupole mass spectrometry screening to liquid chromatography high resolution mass spectrometry screening for doping control purposes. Up to now, for gas chromatography a similar switch to high resolution screening has not yet occurred, because so far no method has been developed that combines sufficient sensitivity with wide-scale drug detection. In this work, the current gas chromatography triple quadrupole mass spectrometry screening method for human doping control purposes was successfully converted into an equivalent and complete gas chromatography high resolution acquisition screening method. This new screening method on a gas chromatography quadrupole time-of-flight mass spectrometer has been developed and validated. The method is compliant with the World Anti-Doping Agency requirements and allows the detection of 294 target compounds (and 14 internal standards), including diuretics, stimulants, narcotics, beta-2-agonists, beta-blockers, hormone modulators, anabolic agents and the quantification of 14 endogenous steroids in a single fast run (14.1â¯min).
Assuntos
Anabolizantes/urina , Cromatografia Gasosa-Espectrometria de Massas/métodos , Detecção do Abuso de Substâncias/métodos , Dopagem Esportivo/métodos , HumanosRESUMO
Urine collection containers used in the doping control collection procedure do not provide a protective environment for urine, against degradation by microorganisms and proteolytic enzymes. An in-house chemical stabilization mixture was developed to tackle urine degradation problems encountered in human sport samples, in cases of microbial contamination or proteolytic activity. The mixture consists of antimicrobial substances and protease inhibitors for the simultaneous inactivation of a wide range of proteolytic enzymes. It has already been tested in lab-scale, as part of World Anti-Doping Agency's (WADA) funded research project, in terms of efficiency against microbial and proteolytic activity. The present work, funded also by WADA, is a follow-up study on the improvement of chemical stabilization mixture composition, application mode and limitation of interferences, using pilot urine collection containers, spray-coated in their internal surface with the chemical stabilization mixture. Urine in plastic stabilized collection containers have been gone through various incubation cycles to test for stabilization efficiency and analytical matrix interferences by three WADA accredited Laboratories (Athens, Ghent, and Rome). The spray-coated chemical stabilization mixture was tested against microorganism elimination and steroid glucuronide degradation, as well as enzymatic breakdown of proteins, such as intact hCG, recombinant erythropoietin and small peptides (GHRPs, ipamorelin), induced by proteolytic enzymes. Potential analytical interferences, observed in the presence of spray-coated chemical stabilization mixture, were recorded using routine screening procedures. The results of the current study support the application of the spray-coated plastic urine container, in the doping control collection procedure. Copyright © 2016 John Wiley & Sons, Ltd.
Assuntos
Manejo de Espécimes/métodos , Detecção do Abuso de Substâncias/métodos , Urinálise/métodos , Urina/química , Gonadotropina Coriônica/urina , DNA/urina , Dopagem Esportivo , Eritropoetina/urina , Seguimentos , Humanos , Peptídeos/urina , Projetos Piloto , Proteólise , Proteínas Recombinantes/urina , Manejo de Espécimes/instrumentação , Esteroides/urina , Detecção do Abuso de Substâncias/instrumentação , Urinálise/instrumentação , Urina/microbiologiaRESUMO
RATIONALE: The detection of new anabolic steroid metabolites and new designer steroids is a challenging task in doping analysis. Switching from electron ionization gas chromatography triple quadrupole mass spectrometry (GC/EI-MS/MS) to chemical ionization (CI) has proven to be an efficient way to increase the sensitivity of GC/MS/MS analyses and facilitate the detection of anabolic steroids. CI also extends the possibilities of GC/MS/MS analyses as the molecular ion is retained in its protonated form due to the softer ionization. In EI it can be difficult to find previously unknown but expected metabolites due to the low abundance or absence of the molecular ion and the extensive (and to a large extent unpredictable) fragmentation. The main aim of this work was to study the CI and collision-induced dissociation (CID) behavior of a large number of anabolic androgenic steroids (AAS) as their trimethylsilyl derivatives in order to determine correlations between structures and CID fragmentation. Clarification of these correlations is needed for the elucidation of structures of unknown steroids and new metabolites. METHODS: The ionization and CID behavior of 65 AAS have been studied using GC/CI-MS/MS with ammonia as the reagent gas. Glucuronidated AAS reference standards were first hydrolyzed to obtain their free forms. Afterwards, all the standards were derivatized to their trimethylsilyl forms. Full scan and product ion scan analyses were used to examine the ionization and CID behavior. RESULTS: Full scan and product ion scan analyses revealed clear correlations between AAS structure and the obtained mass spectra. These correlations were confirmed by analysis of multiple hydroxylated, methylated, chlorinated and deuterated analogs. CONCLUSIONS: AAS have been divided into three groups according to their ionization behavior and into seven groups according to their CID behavior. Correlations between fragmentation and structure were revealed and fragmentation pathways were postulated.
Assuntos
Anabolizantes/química , Cromatografia Gasosa-Espectrometria de Massas/métodos , Esteroides/química , Estrutura MolecularRESUMO
In 2013, the World Anti-Doping Agency (WADA) drastically lowered the minimum required performance levels (MRPLs) of most doping substances, demanding a substantial increase in sensitivity of the existing methods. For a number of compounds, conventional electron impact ionization gas chromatography tandem mass spectrometry (GC-EI-MS/MS) is often no longer sufficient to reach these MRPLs and new strategies are required. In this study, the capabilities of positive ion chemical ionization (PICI) GC-MS/MS are investigated for a wide range of drug related compounds of various classes by injection of silylated reference standards. Ammonia as PICI reagent gas had superior characteristics for GC-MS/MS purposes than methane. Compared to GC-EI-MS/MS, PICI (with ammonia as reagent gas) provided more selective ion transitions and consequently, increased sensitivity by an average factor of 50. The maximum increase (by factor of 500-1000) was observed in the analysis of stimulants, namely chlorprenaline, furfenorex and phentermine. In total, improved sensitivity was obtained for 113 out of 120 compounds. A new GC-PICI-MS/MS method has been developed and evaluated for the detection of a wide variety of exogenous doping substances and the quantification of endogenous steroids in urine in compliance with the required MRPLs established by WADA in 2013. The method consists of a hydrolysis and extraction step, followed by derivatization and subsequent 1µL pulsed splitless injection on GC-PICI-MS/MS (16min run). The increased sensitivity allows the set up of a balanced screening method that meets the requirements for both quantitative and qualitative compounds: sufficient capacity and resolution in combination with high sensitivity and short analysis time. This resulted in calibration curves with a wide linear range (e.g., 48-9600ng/mL for androsterone and etiochanolone; all r(2)>0.99) without compromising the requirements for the qualitative compounds.
Assuntos
Cromatografia Gasosa-Espectrometria de Massas/métodos , Preparações Farmacêuticas/análise , Dopagem Esportivo , Humanos , Limite de Detecção , Padrões de ReferênciaRESUMO
A rapid and sensitive determination of cannabinoids in urine is important in many fields, from workplace drug testing over toxicology to the fight against doping. The detection of cannabis abuse is normally based on the quantification of the most important metabolite 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid (THCA) in urine. In most fields THCA needs to be present at a concentration of exceeding 15ng/mL before a positive result can be reported. The method described in this paper, combines a 4min GC-MS/MS method with a fast sample preparation procedure using microwave assisted derivatisation in order to complete the quantification of THCA in urine in 30min, using only 1mL of urine. The method is selective, linear over the range 5-100ng/mL and shows excellent precision and trueness and hence, the estimated measurement uncertainty at the threshold level is small. The method also complies with applicable criteria for mass spectrometry and chromatography. Therefore the method can be used for rapid screening and confirmatory purposes.
RESUMO
A GC-QqQ-MS method was developed for the detection of over 150 compounds from different classes (steroids, narcotics, stimulants, ß-blockers, ß-2-agonists and hormone antagonists) in a qualitative way. In the quantitative part, the traditional steroid profile with the most important endogenous steroids is expanded with six minor metabolites, which further improves the detection and identification of endogenous steroid abuse. In addition to these, norandrosterone, salbutamol and the major metabolite of cannabis are also quantified. Methods developed for anti-doping purposes should be subjected to the highest level of quality. Here, the addition of a combination of (deuterated) internal standards allows for an accurate quality control of every single step of the methodology: hydrolysis efficiency, derivatization efficiency and microbiological degradation are monitored in every single sample. Additionally, special attention is paid to the relationships between parameters indicating degradation by micro-organisms and the reliability of the steroid profile. The impact of the degradation is studied by evaluation of the quantities and percentages of 5α-androstane-3,17-dione and 5ß-androstane-3,17-dione. The concept of measurement uncertainty was introduced for the evaluation of relative abundances of mass-to-charge ratios and the obtained ranges were compared with the World Anti-Doping Agency regulations on tolerance windows for relative ion intensities. The results indicate that the approaches are similar.
Assuntos
Dopagem Esportivo , Cromatografia Gasosa-Espectrometria de Massas/métodos , Cromatografia Gasosa-Espectrometria de Massas/normas , Preparações Farmacêuticas/análise , Preparações Farmacêuticas/urina , Detecção do Abuso de Substâncias/métodos , Detecção do Abuso de Substâncias/normas , Estabilidade de Medicamentos , Humanos , Preparações Farmacêuticas/química , Preparações Farmacêuticas/metabolismo , Controle de Qualidade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Manejo de Espécimes , Urina/microbiologiaRESUMO
The use of performance enhancing drugs in sports is prohibited. For the detection of misuse of such substances gas chromatography or liquid chromatography coupled to mass spectrometry are the most frequently used detection techniques. In this work the development and validation of a fast gas chromatography tandem mass spectrometric method for the detection of a wide range of doping agents is described. The method can determine 13 endogenous steroids (the steroid profile), 19-norandrosterone, salbutamol and 11-nor-Δ9-tetrahydrocannabinol.9carboxylic acid in the applicable ranges and to detect qualitatively over 140 substances in accordance with the minimum required performance levels of the World Anti-Doping Agency in 1ml of urine. The classes of substances included in the method are anabolic steroids, ß2-agonists, stimulants, narcotics, hormone antagonists and modulators and beta-blockers. Moreover, using a short capillary column and hydrogen as a carrier gas the run time of the method is less than 8min.