J Pers Med ; 13(4)2023 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-37109074

RESUMO

The soluble urokinase plasminogen activator receptor (suPAR) is the bioactive form of uPAR, a membrane-bound glycoprotein, and it is primarily expressed on the surface of immunologically active cells. Mirroring local inflammation and immune activation, suPAR has gained interest as a potential prognostic biomarker in several inflammatory diseases. Indeed, in many diseases, including cancer, diabetes, cardiovascular diseases, kidney diseases, and inflammatory disorders, higher suPAR concentrations have been associated with disease severity, disease relapse, and mortality. Our review describes and discusses the supporting literature concerning the promising role of suPAR as a biomarker in different autoimmune rheumatic and non-rheumatic diseases.

2.
Clin Chem Lab Med ; 61(7): 1167-1198, 2023 06 27.
Artigo em Inglês | MEDLINE | ID: mdl-36989417

RESUMO

OBJECTIVES: Antinuclear antibodies (ANA) are important for the diagnosis of various autoimmune diseases. ANA are usually detected by indirect immunofluorescence assay (IFA) using HEp-2 cells (HEp-2 IFA). There are many variables influencing HEp-2 IFA results, such as subjective visual reading, serum screening dilution, substrate manufacturing, microscope components and conjugate. Newer developments on ANA testing that offer novel features adopted by some clinical laboratories include automated computer-assisted diagnosis (CAD) systems and solid phase assays (SPA). METHODS: A group of experts reviewed current literature and established recommendations on methodological aspects of ANA testing. This process was supported by a two round Delphi exercise. International expert groups that participated in this initiative included (i) the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) Working Group "Autoimmunity Testing"; (ii) the European Autoimmune Standardization Initiative (EASI); and (iii) the International Consensus on ANA Patterns (ICAP). RESULTS: In total, 35 recommendations/statements related to (i) ANA testing and reporting by HEp-2 IFA; (ii) HEp-2 IFA methodological aspects including substrate/conjugate selection and the application of CAD systems; (iii) quality assurance; (iv) HEp-2 IFA validation/verification approaches and (v) SPA were formulated. Globally, 95% of all submitted scores in the final Delphi round were above 6 (moderately agree, agree or strongly agree) and 85% above 7 (agree and strongly agree), indicating strong international support for the proposed recommendations. CONCLUSIONS: These recommendations are an important step to achieve high quality ANA testing.


Assuntos
Anticorpos Antinucleares , Doenças Autoimunes , Humanos , Doenças Autoimunes/diagnóstico , Técnica Indireta de Fluorescência para Anticorpo/métodos , Padrões de Referência , Linhagem Celular Tumoral
3.
Autoimmun Rev ; 22(5): 103295, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36781037

RESUMO

BACKGROUND AND AIM: Calprotectin (CLP) is a heterodimeric complex formed by two S100 proteins (S100A8/A9), which plays a pivotal role in innate immunity. Due to its intrinsic cytotoxic and proinflammatory properties, CLP controls cell differentiation, proliferation and NETosis and has been associated with a wide range of rheumatic diseases. Our review summarizes the widespread interest in circulating CLP (cCLP) as a biomarker of neutrophil-related inflammation, in autoimmune rheumatic disease (ARD) and non-ARD. METHODS: A thorough literature review was performed using PubMed and EMBASE databases searching for circulating calprotectin and synonyms S100A8/A9, myeloid-related protein 8/14 (MRP8/MRP14), calgranulin A/B and L1 protein in addition to specific ARDs and autoimmune non-rheumatic diseases. We selected only English-language articles and excluded abstracts without the main text. RESULTS: High cCLP serum levels are associated with worse structural outcomes in rheumatoid arthritis and to a lesser extent, in spondyloarthritis. In addition, cCLP can predict disease relapse in some autoimmune diseases including systemic lupus erythematosus (SLE), anti-neutrophil cytoplasmic antibodies-associated vasculitis (AAV) and some severe manifestations of connective tissue diseases, such as glomerulonephritis in SLE, AAV, juvenile idiopathic arthritis, adult-onset Still's disease and lung fibrosis in systemic sclerosis. Therefore, cCLP levels enable the identification of patients who need an accurate and tight follow-up. The clinical usefulness of cCLP as an inflammatory marker has been suggested for inflammatory/autoimmune non-rheumatic diseases, and especially for the monitoring of the inflammatory bowel diseases patients. Currently, there are only a few studies that evaluated the cCLP efficacy as a clinical biomarker in inflammatory/autoimmune non-rheumatic diseases with controversial results. Future studies are warranted to better clarify the role of cCLP in relation to the disease severity in myasthenia gravis, multiple sclerosis, chronic inflammatory demyelinating polyneuropathy, Graves' orbitopathy, autoimmune bullous diseases and uveitis. CONCLUSION: Our literature review supports a relevant role of cCLP as potential prognostic biomarker mirroring local or systemic inflammation, especially in chronic inflammatory rheumatic diseases.


Assuntos
Artrite Juvenil , Doenças Autoimunes , Oftalmopatia de Graves , Lúpus Eritematoso Sistêmico , Doenças Reumáticas , Adulto , Humanos , Complexo Antígeno L1 Leucocitário , Doenças Autoimunes/diagnóstico , Inflamação , Calgranulina A , Calgranulina B , Doenças Reumáticas/diagnóstico , Biomarcadores , Doença Crônica
4.
J Clin Monit Comput ; 37(1): 311-317, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35896757

RESUMO

Isocapnic hyperventilation (ICHV) is occasionally used to maintain the end-expired CO2 partial pressure (PETCO2) when the inspired CO2 (PICO2) rises. Whether maintaining PETCO2 with ICHV during an increase of the PICO2 also maintains arterial PCO2 (PaCO2) remains poorly documented. 12 ASA PS I-II subjects undergoing a robot-assisted radical prostatectomy (RARP) (n = 11) or cystectomy (n = 1) under general endotracheal anesthesia with sevoflurane in O2/air (40% inspired O2) were enrolled. PICO2 was sequentially increased from 0 to 0.5, 1.0, 1.5 and 2% by adding CO2 to the inspiratory limb of the circle system, while increasing ventilation to a target PETCO2 of 4.7-4.9% by adjusting respiratory rate during controlled mechanical ventilation. Pa-ETCO2 gradients were determined after a 15 min equilibration period at each PICO2 level and compared using ANOVA. Mean (standard deviation) age, height, and weight were 66 (6) years, 171 (6) cm, and 75 (8) kg, respectively. Capnograms were normal and hemodynamic parameters remained stable. PETCO2 could be maintained within 4.7-4.9% in all subjects at all times except in 1 subject with 1.5% PICO2 and 5 subjects with 2.0% PICO2; data from the one subject in whom both 1.5 and 2.0% PICO2 resulted in PETCO2 > 5.1% were excluded from analysis. Pa-ETCO2 gradients did not change when PICO2 increased. The effect of a modest rise of PICO2 up to 1.5% on PETCO2 during RARP can be readily overcome by increasing ventilation without altering the Pa-ETCO2 gradients. At higher PICO2, airway pressures may become a limiting factor, which requires further study.


Assuntos
Dióxido de Carbono , Hiperventilação , Masculino , Humanos , Idoso , Respiração , Respiração Artificial , Pulmão
5.
RMD Open ; 8(1)2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35321875

RESUMO

BACKGROUND: Rheumatoid factor (RF) and anti-citrullinated protein/peptide antibodies (ACPA) are important biomarkers for diagnosis of rheumatoid arthritis (RA). However, there is poor harmonisation of RF and ACPA assays. The aim of this study was to refine RF and ACPA interpretation across commercial assays. MATERIALS AND METHODS: Six total RF isotype-non-specific assays, 3 RF IgM isotype-specific assays and 9 ACPA immunoglobulin G assays of 13 different companies were evaluated using 398 diagnostic samples from patients with RA and 1073 disease controls. RESULTS: Using cut-offs proposed by the manufacturer, there was a large variability in diagnostic sensitivity and specificity between assays. Thresholds of antibody levels were determined based on predefined specificities and used to define test result intervals. Test result interval-specific likelihood ratios (LRs) were concordant across the different RF and ACPA assays. For all assays, the LR for RA increased with increasing antibody level. Higher LRs were found for ACPA than for RF. ACPA levels associated with LRs >80 were found in a substantial fraction (>22%) of patients with RA. CONCLUSION: Defining thresholds for antibody levels and assigning test result interval-specific LRs allows alignment of clinical interpretation for all RF and ACPA assays.


Assuntos
Artrite Reumatoide , Fator Reumatoide , Anticorpos Antiproteína Citrulinada , Artrite Reumatoide/diagnóstico , Humanos , Peptídeos , Sensibilidade e Especificidade
6.
Autoimmun Rev ; 19(5): 102513, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32173515

RESUMO

BACKGROUND: The clinical presentation of celiac disease (CD) varies between children. The objective of this study was to document the pre-test probability for CD based on symptoms and routine laboratory test and to evaluate the performance of two IgA anti-tissue transglutaminase (tTG) assays. We critically reviewed the concept of using multiples of the manufacturer's upper limit of normal (ULN), as proposed in the ESPGHAN guidelines (if IgA tTG is >10 times ULN, no biopsy is needed). METHODS: The retrospective study included 91 children with newly diagnosed CD and 605 controls (<16 years). All underwent upper endoscopy with small bowel biopsies. Four laboratory parameters and 16 symptoms were registered. All patients were tested for IgA anti-tTG antibodies with assays from Inova Diagnostics and Thermo Fisher Scientific. RESULTS: Some combinations of clinical symptoms and laboratory parameters had a high pre-test probability for CD, such as (combinations of) anorexia, failure to thrive, low ferritin level and elevated AST. The diagnostic performance of both IgA anti-tTG assays was excellent and comparable (no difference in ROC curve area under the curve). At a threshold that corresponds to a specificity of 100% (5 times ULN for Inova Diagnostics and 2 times ULN for Thermo Fisher), the sensitivity was 82% for both assays. At the 10 times ULN threshold, the sensitivity differed between the assays (77% vs. 57%), indicating that such threshold does not completely align interpretation across companies. CONCLUSIONS: Our study showed that some combinations of symptoms and aberrant laboratory parameters had a high pre-test probability. The use of the ESPGHAN non-biopsy approach could reduce small bowel biopsies, but thresholds for IgA-tTG levels are not aligned across assays and should be based on predefined likelihood ratios or specificity.


Assuntos
Doença Celíaca/sangue , Doença Celíaca/diagnóstico , Adolescente , Autoanticorpos/sangue , Autoanticorpos/imunologia , Biópsia , Criança , Pré-Escolar , Feminino , Humanos , Imunoglobulina A/sangue , Imunoglobulina A/imunologia , Lactente , Recém-Nascido , Masculino , Estudos Retrospectivos , Sensibilidade e Especificidade , Transglutaminases/imunologia
8.
Am J Clin Pathol ; 147(6): 611-622, 2017 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-28575180

RESUMO

OBJECTIVES: Free light chain (FLC) measurement gained a lot of interest for diagnostic workup of monoclonal gammopathy. METHODS: We evaluated the performance of turbidimetric polyclonal Freelite (The Binding Site, Birmingham, UK) assays on Cobas 6000 (Roche Diagnostics, Rotkreuz, Switzerland) and nephelometric monoclonal N Latex (Siemens Healthcare Diagnostics, Marburg, Germany) assays on BN ProSpec (Dade Behring, Deerfield, IL) vs established nephelometric Freelite assays on BN ProSpec. RESULTS: Analytical performance was acceptable. Method comparison (n = 118) showed significant proportional FLC differences for N Latex assays. However, good correlation and clinical concordance were shown. Recovery study in the low concentration range demonstrated consistent over- and underrecovery for Freelite reagents, hampering future research on prognostic value of suppressed noninvolved FLC. Antigen excess detection was successful for κ FLC in three-fourths of cases with Freelite reagents and in all cases with N Latex reagents. However, the latter resulted in underestimated κ FLC concentrations. CONCLUSIONS: FLC analysis requires continuous awareness of analytical limitations. Monitoring of disease response requires FLC analysis on the same platform using the same reagents.


Assuntos
Cadeias Leves de Imunoglobulina/sangue , Cadeias kappa de Imunoglobulina/sangue , Cadeias lambda de Imunoglobulina/sangue , Nefelometria e Turbidimetria/métodos , Paraproteinemias/diagnóstico , Anticorpos Monoclonais/imunologia , Humanos , Cadeias Leves de Imunoglobulina/imunologia , Cadeias kappa de Imunoglobulina/imunologia , Cadeias lambda de Imunoglobulina/imunologia , Paraproteinemias/imunologia , Prognóstico , Kit de Reagentes para Diagnóstico , Sensibilidade e Especificidade
9.
J Immunol Res ; 2017: 6038137, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28321418

RESUMO

Background. Our study aimed to investigate whether the introduction of automated anti-nuclear antibody (ANA) indirect immunofluorescence (IIF) analysis decreases the interlaboratory variability of ANA titer results. Method. Three serum samples were sent to 10 laboratories using the QUANTA-Lyser® in combination with the NOVA View®. Each laboratory performed the ANA IIF analysis 10x in 1 run and 1x in 10 different runs and determined the endpoint titer by dilution. One of the three samples had been sent in 2012, before the era of ANA IIF automation, by the Belgian National External Quality Assessment (EQA) Scheme. Harmonization was evaluated in terms of variability in fluorescence intensity (LIU) and ANA IIF titer. Results. The evaluation of the intra- and interrun LIU variability revealed a larger variability for 2 laboratories, due to preanalytical and analytical problems. Reanalysis of the EQA sample resulted in a lower titer variability. Diluted endpoint titers were similar to the estimated single well titer and the overall median titer as reported by the EQA in 2012. Conclusion. The introduction of automated microscopic analysis allows more harmonized ANA IIF reporting, provided that this totally automated process is controlled by a thorough quality assurance program, covering the total ANA IIF process.


Assuntos
Anticorpos Antinucleares/sangue , Automação Laboratorial , Doença de Crohn/diagnóstico , Técnica Indireta de Fluorescência para Anticorpo , Síndrome de Sjogren/diagnóstico , Bélgica , Doença de Crohn/epidemiologia , Técnica Indireta de Fluorescência para Anticorpo/instrumentação , Técnica Indireta de Fluorescência para Anticorpo/métodos , Humanos , Microscopia de Fluorescência , Variações Dependentes do Observador , Garantia da Qualidade dos Cuidados de Saúde , Reprodutibilidade dos Testes , Síndrome de Sjogren/epidemiologia , Avaliação da Tecnologia Biomédica
10.
Clin Chem Lab Med ; 55(10): 1564-1573, 2017 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-28222018

RESUMO

BACKGROUND: We evaluated the analytical performance of six different faecal calprotectin immunoassays together with their diagnostic accuracy in the discrimination between functional and organic bowel disorders. METHODS: The faecal samples were obtained from inflammatory bowel disease patients (n=27) at the time of diagnosis [Crohn's disease (n=15), colitis ulcerosa (n=12)], gastroenterologic disease control patients (n=52) and rheumatologic disease control patients (n=26). All individuals included in the study underwent a concurrent ileocolonoscopy. Analytical performance (imprecision, accuracy, carry-over, correlation and agreement) and diagnostic accuracy (sensitivity, specificity, likelihood ratios) of the different assays were evaluated. RESULTS: All methods demonstrated good analytical performance, but within-run and total imprecision varied depending on the assay methodology used. Using Passing Bablok and Bland-Altman analyses, low quantitative agreement was observed between the assays. All assays showed excellent diagnostic accuracy, with areas under the receiver operating characteristic curves (ROC) ranging from 0.974 to 0.998. The AUCs were not significantly different between assays (p>0.05). Diagnostic sensitivity at the cut-off at a fixed specificity of 75% ranged from 95.2% to 100%. Introduction of multiple result intervals increased the clinical interpretation of all the assays. CONCLUSIONS: Analytical and diagnostic performance of the evaluated faecal calprotectin assays is good, but numerical values differ substantially between the assays necessitating the use of different clinical cut-offs. Introduction of multiple result intervals aids in clinical decision-making.


Assuntos
Fezes/química , Imunoensaio , Doenças Inflamatórias Intestinais/diagnóstico , Complexo Antígeno L1 Leucocitário/análise , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Colonoscopia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Kit de Reagentes para Diagnóstico , Reprodutibilidade dos Testes , Adulto Jovem
12.
Clin Chem Lab Med ; 50(6): 1083-91, 2012 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-22706251

RESUMO

BACKGROUND: The immediate impact of blood gas test results on patient care favors the use of blood gas analyzers as point-of-care-testing (POCT) devices. We performed an analytical performance evaluation of four cartridge-type blood gas analyzers for the determination of pH, partial carbon dioxide pressure (pCO2), partial oxygen pressure (pO2), ionized calcium (iCa2+), potassium (K+), glucose, lactate and total hemoglobin (tHb), in comparison with a traditional blood gas analyzer. METHODS: The analyzers included in the study are: RP405, GEM Premier 4000, ABL90 FLEX and Cobas b 123. The ABL700 served as comparator. For each instrument the imprecision was estimated according to the CLSI EP5-A2. Based on the CLSI EP9-A2 evaluation protocol, a method comparison was performed using patient samples. Obtained data were compared against preset quality specifications, based on ABL700 performance and biological variation. RESULTS: The precision of the RP405 and ABL90 FLEX was remarkably better than the preset criteria based on ABL700 performance. The GEM appears to have the worst precision. The RP405 yielded the best overall performance, with exception for tHb and iCa2+. Noteworthy is the very good performance of the glucose determination on RP405. The ABL90 FLEX showed the best performance for pH, K+ and iCa2+ measurements. For tHb determination the Cobas b123 revealed the best results. Regarding practicability, all instruments were found to be user friendly. CONCLUSIONS: Globally, all four cartridge-type blood gas analyzers produced clinically acceptable results. The analytical performance, together with the ease of use and low maintenance time of the instruments, demonstrate that these analyzers are perfectly suitable for both POCT and laboratory use.


Assuntos
Gasometria/métodos , Gasometria/instrumentação , Humanos , Sistemas Automatizados de Assistência Junto ao Leito , Sensibilidade e Especificidade
13.
Br J Haematol ; 143(4): 496-502, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18729849

RESUMO

The present study aimed to determine the diagnostic performance of different testing strategies to diagnose malignant B-cell disorder or monoclonal gammopathy of unknown significance (MGUS). Sensitivity and specificity were determined in 833 consecutive patients investigated for a monoclonal gammopathy. Serum protein electrophoresis (PE), serum kappa/lambda free light chain (FLC) ratio, and serum and urine immunofixation electrophoresis (IFE) were performed in all patients. Twenty-eight patients were diagnosed with a malignant plasma cell disorder, 25 with B-cell non-Hodgkin lymphoma and 156 with MGUS. Serum PE (with follow-up IFE) plus FLC had a sensitivity of 82.3% and a specificity of 96.8% and missed one plasmacytoma and 23 patients with MGUS. Serum IFE plus urine IFE had a sensitivity of 92.3% and a specificity of 100% and missed two MGUS patients. Serum IFE plus FLC had a sensitivity of 93.8% and a specificity of 96.8% and missed one MGUS patient. Serum PE plus FLC had a significantly lower sensitivity than serum IFE plus FLC or serum IFE plus urine IFE for the diagnosis of MGUS. The sensitivity of serum IFE plus FLC was comparable to the sensitivity of serum IFE plus urine IFE. The specificity of serum IFE plus FLC, however, was lower than the specificity of serum IFE plus urine IFE.


Assuntos
Cadeias Leves de Imunoglobulina/sangue , Linfoma de Células B/diagnóstico , Paraproteinemias/diagnóstico , Adulto , Idoso , Biomarcadores/sangue , Biomarcadores Tumorais/sangue , Diagnóstico Diferencial , Feminino , Humanos , Cadeias Leves de Imunoglobulina/urina , Masculino , Pessoa de Meia-Idade , Mieloma Múltiplo/diagnóstico , Sensibilidade e Especificidade , Adulto Jovem
14.
Clin Chim Acta ; 397(1-2): 77-81, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18708041

RESUMO

BACKGROUND: Anti-neutrophil cytoplasmic antibodies (ANCA) are associated with primary small vessel vasculitis (SVV). Proteinase-3 (PR3)-ANCA are primarily associated with Wegener granulomatosis, whereas myeloperoxidase (MPO)-ANCA are primarily associated with microscopic polyangiitis (MPA) and vasculitic Churg-Strauss syndrome. We evaluated whether a strategy that is based on screening with ELISA or fluoroenzymeimmunoassay (FEIA) is an accurate alternative to screening with indirect immunofluorescence (IIF). METHODS: C-ANCA and P-ANCA were determined by IIF and PR3-ANCA and MPO-ANCA were determined by ELISA (Inova) or FEIA (Phadia) on 326 patients (38 with newly diagnosed SVV and 288 diseased controls). RESULTS: Specificity and positive likelihood ratios were higher for ELISA and FEIA than for IIF. Post-test probability for SVV of a positive test result was higher for ELISA and FEIA than for IIF. Decision tree analysis in which several testing strategies were compared revealed that a testing strategy that is based on screening with ELISA or FEIA had an expected clinical utility that was comparable to screening with IIF and confirming with ELISA or FEIA. The highest expected clinical utility was found when both IIF and ELISA or FEIA were performed on all samples. CONCLUSIONS: A strategy based on screening for ANCA with ELISA or FEIA (without prior IIF) is a valuable alternative to screening with IIF and confirming with ELISA or FEIA.


Assuntos
Anticorpos Anticitoplasma de Neutrófilos/sangue , Autoanticorpos/sangue , Vasos Sanguíneos/imunologia , Vasculite/imunologia , Ensaio de Imunoadsorção Enzimática , Técnica Indireta de Fluorescência para Anticorpo , Humanos , Mieloblastina/imunologia , Neutrófilos/enzimologia , Neutrófilos/imunologia , Peroxidase/imunologia , Sensibilidade e Especificidade , Vasculite/sangue