Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Vasc Surg ; 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38552883

RESUMO

OBJECTIVE: To present a single-center prospective study of 126 consecutively treated patients who underwent endovascular repair of a thoracoabdominal aortic aneurysm with the physician-modified, nonanatomic-based Unitary Manifold (UM) device. METHODS: Data were collected from 126 consecutive all-comer patients treated with the physician-modified, nonanatomic-based UM from 2015 to 2023. Treatment was performed at a single center by a single physician under a Physician Sponsored Investigation Exemption G140207. RESULTS: The UM was indicated for repair of all Crawford extents including juxtarenal, pararenal, and short-neck infrarenal aneurysms (<10 mm) in 126 consecutive patients. Patients were not excluded from the study based on presentation, extent of aneurysm or dissection, or history of a spinal cord event. Patients with a thoracoabdominal aortic aneurysm were categorized by Crawford classification: types I and V (3.3%, n = 4), type II (3.3%, n = 4), type III (1%, n = 1), and type IV (93.3%, n = 117). The type IV classification patients were further categorized with 33 (28.2%) true type IV, 68 (58.1%) pararenal or infrarenal, and 16 (13.7%) with dissection. Technical success was 99.2% (n = 125). The most common major adverse event within both 30 days and 365 days of all patients was respiratory failure (11.9%, n = 15, and 13.5%, n = 17, respectively). One patient (0.8%) experienced persistent paraplegia at 365 days. Reintervention for patients at 365 days was 5.6% (n = 7). Of the 444 branches stented, the primary patency rate was remarkably high as only three patients (2.4%) required reintervention due to loss of limb patency within 365 days. Aneurysm enlargement (≥5 mm) occurred in 1.6% (n = 2) patients, and no patients experienced aneurysm rupture. No patients underwent conversion to open repair. The aneurysm-related mortality at 365 days for all patients was 4.0% (n = 5), whereas all-cause mortality was 16.7% (n = 21). Physician-modified endograft device integrity failure was not observed in any patient. CONCLUSIONS: The UM device demonstrated remarkable technical surgical success, treatment success, and device patency rates with very reasonable major adverse events and reintervention rates. This study is the most representative example of the general population in comparison with other studies of off-the-shelf devices, with 126 consecutive all-comer patients with diverse pathologies.

2.
Ann Vasc Surg ; 97: 236-247, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37659649

RESUMO

BACKGROUND: Spinal cord ischemia (SCI) continues to be a devastating complication after repair of thoracoabdominal aortic aneurysms. The objective of this review is to present our single-center outcomes after the implementation of a standardized neuroprotective protocol following branched endovascular aortic repair. METHODS: A standardized neuroprotective protocol including preoperative steroids, acetazolamide, intraoperative hemodynamic parameters, and postoperative treatment goals was initiated in November 2019. Physician-modified branched endovascular repairs were completed at a single center from 2012 to 2021 with outcomes reviewed both before (n = 107) and after (n = 67) the implementation of the neuroprotective protocol. The primary end point was the incidence of any SCI event at 30 days. Secondary end points included all-cause mortality, stroke, myocardial infarction, and renal failure at 30 days. Patients with Crawford extents I-III, renal failure, or necessitating emergent repair were deemed high risk for SCI events and underwent a subset analysis. Survivability after SCI was estimated using Kaplan-Meier tables. RESULTS: Of the 174 consecutive patients treated, the 67 patients treated following implementation of the neuroprotective protocol were more likely to have experienced a prior myocardial infarction (26.9% vs. 14%; P = 0.0466) and have a history of chronic obstructive pulmonary disease (64.3% vs. 45.8%; P = 0.02). This group was more likely to be treated for paravisceral aneurysms (53.7% vs. 24.3%; P = 0.0002). Postprotocol implementation, spinal drain use was lower (6% vs. 38.3%; P = <0.0001) with 100% of these drains placed in urgent or unstaged thoracoabdominal aortic aneurysm repairs as a part of the protocol. Rates of any SCI event among all patients before and after implementation of the protocol were 9.3% (n = 10 of 107) and 6% (n = 4 of 67; P = 0.57), respectively. In comparison, the protocol significantly reduced SCI rates to 0 (0% vs. 17.1%; P = 0.0407) in high-risk patients. Frequency of renal failure was reduced (3% vs. 14%; P = 0.018) after initiation of the protocol. Patients in the postprotocol group had significantly improved 1-year mortality rate (9% vs. 27.1%; P = 0.0035) and renal failure rates (2% vs. 15%; P = 0.018). Regression models indicated that patients in the postprotocol group had lower likelihood of mortality and renal failure than patients in preprotocol group (P < 0.05) and that spinal drain reduced mortality (P < 0.1). CONCLUSIONS: Implementation of a standardized neuroprotective protocol that focuses on medical management and fluid dynamics may significantly reduce risk of SCI after branched endovascular repairs, with the most significant improvement of SCI outcomes involving those at greatest risk for developing SCI. Also noteworthy, there was significant improvement to 1-year survivability after the implementation of this neuroprotective protocol.


Assuntos
Aneurisma da Aorta Torácica , Aneurisma da Aorta Toracoabdominal , Procedimentos Endovasculares , Infarto do Miocárdio , Insuficiência Renal , Isquemia do Cordão Espinal , Humanos , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Correção Endovascular de Aneurisma , Infarto do Miocárdio/etiologia , Insuficiência Renal/etiologia , Estudos Retrospectivos , Literatura de Revisão como Assunto , Fatores de Risco , Isquemia do Cordão Espinal/etiologia , Isquemia do Cordão Espinal/prevenção & controle , Isquemia do Cordão Espinal/cirurgia , Fatores de Tempo , Resultado do Tratamento
3.
Ann Vasc Surg ; 93: 174-184, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36706948

RESUMO

BACKGROUND: Aneurysmal degeneration of aortic dissection portends significant morbidity and mortality consequences in the subacute and chronic phases of aortic dissection. This article describes the use of a multibranched stent graft system for the treatment of thoracoabdominal aneurysmal degeneration of dissections with visceral segment involvement and reports upon the 30-day and 1-year outcomes for the first 18 patients treated with this design configuration. METHODS: The in-hospital, 30-day and 1-year morbidity and mortality outcomes of 18 consecutive patients treated with the physician-assembled visceral manifold or unitary manifold stent graft systems between 2013 and 2022 were evaluated. RESULTS: A total of 18 patients were treated for aneurysmal changes after aortic dissection. A total of 71 visceral vessels were successfully stented. There were no acute procedural failures. There were no episodes of paraplegia, reinterventions for type I or III endoleaks, patency-related events or mortalities reported in the first 30 days following treatment. One-year, all-cause mortality demonstrated 2/11 (18.2%). CONCLUSIONS: The aneurysmal degeneration of aortic dissection poses significant risks to patients with medically managed aortic dissections and those under surveillance. When these aneurysms develop in the thoracoabdominal region, treatment becomes even more challenging given the problem of visceral vessel patency, as these vessels can originate off the true or false lumens. The physician-designed endovascular stent graft system reported upon here has been successfully deployed in 18 patients with no acute procedural failures and promising clinical results. This treatment modality may offer utility to vascular surgeons whose patients with thoracoabdominal aneurysmal degeneration following aortic dissection have historically had limited endovascular repair prospects.


Assuntos
Aneurisma da Aorta Torácica , Aneurisma da Aorta Toracoabdominal , Dissecção Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Médicos , Humanos , Prótese Vascular/efeitos adversos , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/etiologia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Fatores de Risco , Resultado do Tratamento , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/terapia , Procedimentos Endovasculares/efeitos adversos , Stents/efeitos adversos , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/etiologia , Dissecção Aórtica/cirurgia , Desenho de Prótese
4.
Ann Vasc Surg ; 76: 232-243, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34182119

RESUMO

BACKGROUND: The purpose of this study was to examine the incidence of acute kidney injury and chronic renal impairment following branched endovascular aneurysm repair (BEVAR) of complex thoracoabdominal aortic aneurysms (TAAA) using the Medtronic Valiant Thoracoabdominal Aortic Aneurysm stent graft system (MVM), the physician-modified Visceral Manifold, and Unitary Manifold stent graft systems. The objective was to report the acute and chronic renal function changes in patients following complex TAAA aneurysm repair. METHODS: This is an analysis of 139 patients undergoing branched endovascular repair for complex TAAAs between 2012 and 2020. Patient renal function was evaluated using serum creatinine and estimated glomerular filtration rate at baseline, 48 hr, discharge, 1 month, 6 months, and annually to 2 years. Patients on dialysis prior to the procedure were excluded from data analysis. RESULTS: A total of 139 patients (mean age 71.13; 64.7% male) treated for TAAA with BEVAR met inclusion criteria and were evaluated. A total of 530 visceral vessels were stented. A majority of patients (n = 131, 94.2%) underwent a single procedure while 8 required staged procedures. Thirty-day, 1-year and 2-year all-cause mortality rates were 5.8%, 25.2%, and 32.4%, respectively. Primary and secondary patency rates at a median follow-up of 26.9 months (95% CI; 21.1 - 32.7) were 96.2% and 97.5% for all vessels and 95.4% and 96.9% for renal arteries, respectively. Postoperative acute kidney injury (AKI) was identified in 22 (15.8%) patients. At discharge, 16 patients (11.6%) had an increase in CKD stage with 3 requiring permanent dialysis. Five additional patients required permanent dialysis over the 2-year follow-up period for a total of 8 (5.8%). Increasing age (HR = 1.0327, P= 0.0477), hemoglobin < 7 prior to procedure (HR = 2.4812, P= 0.0093), increasing maximum aortic diameter (HR = 1.0189, P= 0.0084), presence of AKI (HR = 2.0757, P= 0.0182), and increase in CKD stage (HR = 1.3520, P= 0.002) at discharge were significantly associated with decreased patient survival. CONCLUSIONS: Postoperative AKI and a chronic decline in renal function continue to be problematic in endovascular repair of complex aortic aneurysms. This study found that BEVAR using the manifold configuration resulted in immediate and mid-term renal function that is comparable to similar analyses of branched and/or fenestrated grafts.


Assuntos
Injúria Renal Aguda/epidemiologia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Falência Renal Crônica/epidemiologia , Injúria Renal Aguda/diagnóstico , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/epidemiologia , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Procedimentos Endovasculares/instrumentação , Feminino , Humanos , Incidência , Falência Renal Crônica/diagnóstico , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Stents , Fatores de Tempo , Estados Unidos/epidemiologia
5.
J Vasc Surg ; 73(2): 426-432.e2, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32640319

RESUMO

BACKGROUND: In-hospital and 30-day mortality rates of endovascular repair of thoracoabdominal aortic aneurysms shows a significant improvement over open surgery, although we are not seeing a significant difference at 1 year. We assess the hypothesis that a greater mural thrombus ratio within the aorta could function as an indicator of postoperative mortality. METHODS: The mural thrombus ratio and preoperative comorbidities of 100 consecutive patients from a single center undergoing endo-debranching between 2012 and 2019 were evaluated. Logistic regression, survival analysis, and decision tree methods were used to examine each variable's association with death at 1 year. RESULTS: At the time of analysis, 73 subjects had 1-year outcomes and adequate imaging to assess the parameters. At 1 year, the overall survival for all subjects was 71.2% (21 died, 52 survived). For patients with a favorable mural thrombus ratio (n = 36), the overall 1-year survival was 86.1% (5 died, 31 survived). The subjects with an unfavorable mural thrombus ratio (n = 37), had an overall 1 year survival of 56.8% (16 died, and 21 survived). The only preoperative mortality factor that was statistically significant between the subjects with an unfavorable mural thrombus ratio was age of the patient. The survival for subjects 75 years and older with an unfavorable mural thrombus ratio was 90% (one died, nine survived) vs only 44.4% survival for subjects less than 75 years with an unfavorable mural thrombus ratio (15 died, 12 survived). CONCLUSIONS: This study examined whether a patient's mural thrombus ratio may be an indicator of 1-year survival. These findings suggest that the combination of a patient's aortic mural thrombus ratio and age can function as a preoperative indicator of their underlying cardiac reserve. Identifying patients with low cardiac reserve and fitness to handle the increased cardiac demands owing to the physiologic response to extensive aortic stent grafting before undergoing aortic repair may allow for modification of preoperative patient counseling and postoperative care guidelines to better treat this patient population.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/mortalidade , Procedimentos Endovasculares/mortalidade , Trombose/mortalidade , Fatores Etários , Idoso , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/mortalidade , Aortografia , Implante de Prótese Vascular/efeitos adversos , Comorbidade , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/efeitos adversos , Feminino , Mortalidade Hospitalar , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Trombose/diagnóstico por imagem , Fatores de Tempo , Resultado do Tratamento
6.
J Vasc Surg ; 72(6): 1897-1905.e2, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32335306

RESUMO

OBJECTIVE: In the present study, we reviewed the 30-day and 1-year clinical results of the use of the investigational unitary manifold (UM) stent graft system (Sanford Health, Sioux Falls SDak) for the repair of Crawford type IV, pararenal, paravisceral, juxtarenal, and short-neck infrarenal aneurysms (<10 mm). METHODS: The present study was a single-center, multiarm, prospective review of the first 44 patients who had undergone repair of Crawford type IV, pararenal, juxtarenal, and short-neck infrarenal aneurysms (<10 mm) using the physician-modified UM under a physician-sponsored investigational device exemption. The primary end point was freedom from major adverse events at 30 days, including all-cause mortality, myocardial infarction, stroke, paraplegia, bowel ischemia, respiratory failure, and renal failure. RESULTS: Technical success was achieved in all 44 patients (100%), with a large number of these patients having undergone previous aortic repair (20 of 44; 45.5%). All the intended 170 visceral vessels (100%) had been successfully cannulated and stent grafted. No episodes of paraplegia or in-hospital deaths were recorded. One patient had died of aneurysm-related ischemic stroke (2.3%). The rate of transient nonclinically significant spinal cord ischemia was 4.5%. At the last follow-up, one reintervention had been required owing to branch patency from a thrombotic event. Of the 170 bridging stent grafts, 169 have remained patent through a mean follow-up of 8.8 months (range, 0-36 months). No type I or III endoleaks, migration, or component separation in the investigational device has occurred. CONCLUSIONS: The early and midterm results with the use of the UM suggest it could be a viable option for the repair of Crawford type IV, pararenal, paravisceral, juxtarenal, and short-neck infrarenal aneurysms (<10 mm) without exposing patients to the increased risk of permanent spinal cord ischemia, renal failure, visceral vessel ischemia, or aneurysm-related mortality that results from open thoracoabdominal aortic aneurysm repair. The high technical success rate, in native and previous repairs, supports the utility of this device as a bail-out technique for failed endovascular aneurysm repair or proximal extension of disease after previous aortic repair. However, experience is limited, and this approach requires further study before widespread adoption.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/mortalidade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos , Desenho de Prótese , South Dakota , Fatores de Tempo , Resultado do Tratamento
7.
J Vasc Surg Venous Lymphat Disord ; 3(3): 251-7, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26992302

RESUMO

OBJECTIVE: The objective of this study was to evaluate the safety and effectiveness of ultrasound-accelerated thrombolysis in acute pulmonary embolism. METHODS: A retrospective study of 45 patients was performed to evaluate treatment of acute pulmonary embolism at a single center from January 2011 to December 2013. All patients were diagnosed with computed tomography or ventilation-perfusion scan and had hemodynamic instability (systolic blood pressure <100 mm Hg) or right-sided heart strain evidenced by right ventricular dilation, septal deviation, or hypokinesis by echocardiography or computed tomography. EkoSonic catheters (EKOS Corporation, Bothell, Wash) were placed into the affected pulmonary arteries, and recombinant tissue plasminogen activator was infused through the catheters at 0.5 to 1.0 mg/h per catheter. RESULTS: Hypotension (systolic blood pressure <100 mm Hg) was present in 12 patients, with 100% resolution by treatment completion. Tachycardia (heart rate >100 beats/minute) was present in 26 patients and resolved in 92% by treatment completion; the average heart rate for all patients decreased from 109 to 77 beats/minute during the treatment period. Direct pulmonary artery pressure measurement showed average decrease of 21.5 mm Hg, representing a 40.2% reduction. Postprocedure echocardiography demonstrated complete resolution of cardiac dysfunction in 64%. Patients received a total dose of 30.5 mg (range, 14-66 mg) recombinant tissue plasminogen activator during an infusion time of 14.2 hours (range, 8-21 hours). There were no deaths through 90 days of follow-up and no major periprocedural bleeding events. CONCLUSIONS: This retrospective study demonstrates the safety and efficacy of current ultrasound-accelerated thrombolysis methods to treat acute pulmonary embolism.


Assuntos
Embolia Pulmonar/terapia , Terapia Trombolítica , Doença Aguda , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Fibrinolíticos , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Artéria Pulmonar , Embolia Pulmonar/diagnóstico , Estudos Retrospectivos , Ativador de Plasminogênio Tecidual , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA