Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
J Clin Imaging Sci ; 14: 7, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38628606

RESUMO

Objectives: To assess the range of quantitative iodine values in renal cysts (RC) (with a few renal neoplasms [RNs] as a comparison) to develop an expected range of values for RC that can be used in future studies for their differentiation. Material and Methods: Consecutive patients (n = 140) with renal lesions who had undergone abdominal examination on a clinical photon-counting computed tomography (PCCT) were retrospectively included. Automated iodine quantification maps were reconstructed, and region of interest (ROI) measurements of iodine concentration (IC) (mg/cm3) were performed on whole renal lesions. In addition, for heterogeneous lesions, a secondary ROI was placed on the area most suspicious for malignancy. The discriminatory values of minimum, maximum, mean, and standard deviation for IC were compared using simple logistic regression and receiver operating characteristic curves (area under the curve [AUC]). Results: A total of 259 renal lesions (243 RC and 16 RN) were analyzed. There were significant differences between RC and RN for all IC measures with the best-performing metrics being mean and maximum IC of the entire lesion ROI (AUC 0.912 and 0.917, respectively) but also mean and minimum IC of the most suspicious area in heterogeneous lesions (AUC 0.983 and 0.992, respectively). Most RC fell within a range of low measured iodine values although a few had higher values. Conclusion: Automated iodine quantification maps reconstructed from clinical PCCT have a high diagnostic ability to differentiate RCs and neoplasms. The data from this pilot study can be used to help establish quantitative values for clinical differentiation of renal lesions.

2.
Clin Imaging ; 104: 110008, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37862910

RESUMO

PURPOSE: Photon-counting-detector computed tomography (PCD-CT) offers enhanced noise reduction, spatial resolution, and image quality in comparison to energy-integrated-detectors CT (EID-CT). These hypothesized improvements were compared using PCD-CT ultra-high (UHR) and standard-resolution (SR) scan-modes. METHODS: Phantom scans were obtained with both EID-CT and PCD-CT (UHR, SR) on an adult body-phantom. Radiation dose was measured and noise levels were compared at a minimum achievable slice thickness of 0.5 mm for EID-CT, 0.2 mm for PCD-CT-UHR and 0.4 mm for PCD-CT-SR. Signal-to-noise ratios (SNR) and contrast-to-noise ratios (CNR) were calculated for five tissue densities. Additionally, data from 25 patients who had PCD-CT of chest were reconstructed at 1 mm and 0.2 mm (UHR) slice-thickness and compared quantitatively (SNR) and qualitatively (noise, quality, sharpness, bone details). RESULTS: Phantom PCD-CT-UHR and PCD-CT-SR scans had similar measured radiation dose (16.0mGy vs 15.8 mGy). Phantom PCD-CT-SR (0.4 mm) had lower noise level in comparison to EID-CT (0.5 mm) (9.0HU vs 9.6HU). PCD-CT-UHR (0.2 mm) had slightly higher noise level (11.1HU). Phantom PCD-CT-SR (0.4 mm) had higher SNR in comparison to EID-CT (0.5 mm) while achieving higher resolution (Bone 115 vs 96, Acrylic 14 vs 14, Polyethylene 11 vs 10). SNR was slightly lower across all densities for PCD-CT UHR (0.2 mm). Interestingly, CNR was highest in the 0.2 mm PCD-CT group; PCD-CT CNR was 2.45 and 2.88 times the CNR for 0.5 mm EID-CT for acrylic and poly densities. Clinical comparison of SNR showed predictably higher SNR for 1 mm (30.3 ± 10.7 vs 14.2 ± 7, p = 0.02). Median subjective ratings were higher for 0.2 mm UHR vs 1 mm PCD-CT for nodule contour (4.6 ± 0.3 vs 3.6 ± 0.1, p = 0.02), bone detail (5 ± 0 vs 4 ± 0.1, p = 0.001), image quality (5 ± 0.1 vs 4.6 ± 0.4, p = 0.001), and sharpness (5 ± 0.1 vs 4 ± 0.2). CONCLUSION: Both UHR and SR PCD-CT result in similar radiation dose levels. PCD-CT can achieve higher resolution with lower noise level in comparison to EID-CT.


Assuntos
Fótons , Tomografia Computadorizada por Raios X , Adulto , Humanos , Tomografia Computadorizada por Raios X/métodos , Pulmão , Doses de Radiação , Razão Sinal-Ruído , Imagens de Fantasmas
3.
Diagnostics (Basel) ; 13(9)2023 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-37174932

RESUMO

Background: On the basis of the hypothesis that virtual noniodine (VNI)-based coronary artery calcium scoring (CACS) is feasible at reduced radiation doses, this study assesses the impact of radiation dose reduction on the accuracy of this VNI algorithm on a photon-counting detector (PCD)-CT. Methods: In a systematic in vitro setting, a phantom for CACS simulating three chest sizes was scanned on a clinical PCD-CT. The standard radiation dose was chosen at volumetric CT dose indices (CTDIVol) of 1.5, 3.3, 7.0 mGy for small, medium-sized, and large phantoms, and was gradually reduced by adjusting the tube current resulting in 100, 75, 50, and 25%, respectively. VNI images were reconstructed at 55 keV, quantum iterative reconstruction (QIR)1, and at 60 keV/QIR4, and evaluated regarding image quality (image noise (IN), contrast-to-noise ratio (CNR)), and CACS. All VNI results were compared to true noncontrast (TNC)-based CACS at 70 keV and standard radiation dose (reference). Results: INTNC was significantly higher than INVNI, and INVNI at 55 keV/QIR1 higher than at 60 keV/QIR4 (100% dose: 16.7 ± 1.9 vs. 12.8 ± 1.7 vs. 7.7 ± 0.9; p < 0.001 for every radiation dose). CNRTNC was higher than CNRVNI, but it was better to use 60 keV/QIR4 (p < 0.001). CACSVNI showed strong correlation and agreement at every radiation dose (p < 0.001, r > 0.9, intraclass correlation coefficient > 0.9). The coefficients of the variation in root-mean squared error were less than 10% and thus clinically nonrelevant for the CACSVNI of every radiation dose. Conclusion: This phantom study suggests that CACSVNI is feasible on PCD-CT, even at reduced radiation dose while maintaining image quality and CACS accuracy.

4.
Int J Cardiovasc Imaging ; 39(8): 1535-1546, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37148449

RESUMO

Noninvasive identification of active myocardial inflammation in patients with cardiac sarcoidosis plays a key role in management but remains elusive. T2 mapping is a proposed solution, but the added value of quantitative myocardial T2 mapping for active cardiac sarcoidosis is unknown. Retrospective cohort analysis of 56 sequential patients with biopsy-confirmed extracardiac sarcoidosis who underwent cardiac MRI for myocardial T2 mapping. The presence or absence of active myocardial inflammation in patients with CS was defined using a modified Japanese circulation society criteria within one month of MRI. Myocardial T2 values were obtained for the 16 standard American Heart Association left ventricular segments. The best model was selected using logistic regression. Receiver operating characteristic curves and dominance analysis were used to evaluate the diagnostic performance and variable importance. Of the 56 sarcoidosis patients included, 14 met criteria for active myocardial inflammation. Mean basal T2 value was the best performing model for the diagnosis of active myocardial inflammation in CS patients (pR2 = 0.493, AUC = 0.918, 95% CI 0.835-1). Mean basal T2 value > 50.8 ms was the most accurate threshold (accuracy = 0.911). Mean basal T2 value + JCS criteria was significantly more accurate than JCS criteria alone (AUC = 0.981 vs. 0.887, p = 0.017). Quantitative regional T2 values are independent predictors of active myocardial inflammation in CS and may add additional discriminatory capability to JCS criteria for active disease.


Assuntos
Cardiomiopatias , Miocardite , Sarcoidose , Humanos , Estudos Retrospectivos , População do Leste Asiático , Valor Preditivo dos Testes , Imageamento por Ressonância Magnética , Inflamação
5.
Eur Radiol ; 33(3): 2039-2051, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36322192

RESUMO

OBJECTIVES: Cardiac involvement in Anderson-Fabry disease (AFD) results in myocardial lipid depositions. An early diagnosis can maximize therapeutic benefit. Thus, this study aims to investigate the potential of cardiac MRI (CMR) based parameters of left atrial (LA) function and strain to detect early stages of AFD. METHODS: Patients (n = 58, age 40 (29-51) years, 31 female) with genetically proven AFD had undergone CMR including left ventricular (LV) volumetry, mass index (LVMi), T1, and late gadolinium enhancement, complemented by LA and LV strain measurements and atrial emptying fractions. Patients were stratified into three disease phases and compared to age and sex-matched healthy controls (HC, n = 58, age 41 [26-56] years, 31 female). RESULTS: A total of 19 early-, 20 intermediate-, and 19 advanced-phase patients were included. LV and LA reservoir strain was significantly impaired in all AFD phases, including early disease (both p < 0.001). In contrast, LA volumetry, T1, and LVMi showed no significant differences between the early phase and HC (p > 0.05). In the intermediate phase, LVMi and T1 demonstrated significant differences. In advanced phase, all parameters except active emptying fractions differed significantly from HC. ROC curve analyses of early disease phases revealed superior diagnostic confidence for the LA reservoir strain (AUC 0.88, sensitivity 89%, specificity 75%) over the LV strain (AUC 0.82). CONCLUSIONS: LA reservoir strain showed impairment in early AFD and significantly correlated with disease severity. The novel approach performed better in identifying early disease than the established approach using LVMi and T1. Further studies are needed to evaluate whether these results justify earlier initiation of therapy and help minimize cardiac complications. KEY POINTS: • Parameters of left atrial function and deformation showed impairments in the early stages of Anderson-Fabry disease and correlated significantly with the severity of Anderson-Fabry disease. • Left atrial reservoir strain performed superior to ventricular strain in detecting early myocardial involvement in Anderson-Fabry disease and improved diagnostic accuracies of approaches already using ventricular strain. • Further studies are needed to evaluate whether earlier initiation of enzyme replacement therapy based on these results can help minimize cardiac complications from Anderson-Fabry disease.


Assuntos
Fibrilação Atrial , Doença de Fabry , Cardiopatias , Humanos , Feminino , Adulto , Doença de Fabry/diagnóstico por imagem , Doença de Fabry/complicações , Meios de Contraste , Gadolínio , Átrios do Coração/diagnóstico por imagem , Cardiopatias/complicações
6.
Eur J Radiol ; 155: 110471, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35985091

RESUMO

PURPOSE: The accumulation of sphingolipids in Fabry's disease (FD) leads to left ventricular (LV) hypertrophy and shortened T1 in cardiac magnetic resonance (CMR). Early detection of myocardial involvement is essential for the timely initiation and efficacy of enzyme replacement therapy. However, there is a diagnostic gap between the onset of accumulation and detectable myocardial changes. This study aimed to evaluate the diagnostic value of biventricular strain assessment in early FD. METHODS: Genetically proven FD patients (n = 58) and healthy volunteers (HV, n = 62) who had undergone 3 T CMR were retrospectively identified and stratified into 3 groups according to disease severity. Biventricular volumetry, global longitudinal strains (GLS), indexed biventricular masses (RVMi/LVMi), and T1 were evaluated. Group comparisons were performed by ANOVA and diagnostic accuracy was evaluated by ROC-analysis. RESULTS: The study population included 19 group I, 20 group II and 19 group III patients. LV volumetry and T1 showed no significant difference between early FD patients and HV (all p > 0.760). However, RVMi was increased, while RV-GLS and LV-GLS were significantly impaired (p = 0.024 and < 0.001, respectively). Biventricular strains accurately discriminated early FD patients and HV with RV-GLS being non-inferior to LV-GLS (AUC for both 0.83, p > 0.05). Adding strains to the established approach using T1 and LVMi further increased diagnostic accuracy (AUC 0.99, p < 0.05). CONCLUSIONS: Biventricular strains may help detect altered myocardial deformation patterns in phenotypically negative FD patients. These findings may lead to an earlier initiation of therapy, which in turn may slow hypertrophy and the associated long-term risks.


Assuntos
Doença de Fabry , Doença de Fabry/diagnóstico por imagem , Humanos , Hipertrofia , Imagem Cinética por Ressonância Magnética , Miocárdio , Compostos Organometálicos , Valor Preditivo dos Testes , Estudos Retrospectivos , Esfingolipídeos , Função Ventricular Esquerda
7.
Eur Radiol ; 31(10): 7219-7230, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33779815

RESUMO

OBJECTIVES: To compare volumetric and functional parameters of the atria derived from highly accelerated compressed sensing (CS)-based cine sequences in comparison to conventional (Conv) cine imaging. METHODS: CS and Conv cine sequences were acquired in 101 subjects (82 healthy volunteers (HV) and 19 patients with heart failure with reduced ejection fraction (HFrEF)) using a 3T MR scanner in this single-center study. Time-volume analysis of the left (LA) and right atria (RA) were performed in both sequences to evaluate atrial volumes and function (total, passive, and active emptying fraction). Inter-sequence and inter- and intra-reader agreement were analyzed using correlation, intraclass correlation (ICC), and Bland-Altman analysis. RESULTS: CS-based cine imaging led to a 69% reduction of acquisition time. There was significant difference in atrial parameters between CS and Conv cine, e.g., LA minimal volume (LAVmin) (Conv 24.0 ml (16.7-32.7), CS 25.7 ml (19.2-35.2), p < 0.0001) or passive emptying fraction (PEF) (Conv 53.9% (46.7-58.4), CS 49.0% (42.0-54.1), p < 0.0001). However, there was high correlation between the techniques, yielding good to excellent ICC (0.76-0.99) and small mean of differences in Bland-Altman analysis (e.g. LAVmin - 2.0 ml, PEF 3.3%). Measurements showed high inter- (ICC > 0.958) and intra-rater (ICC > 0.934) agreement for both techniques. CS-based parameters (PEF AUC = 0.965, LAVmin AUC = 0.864) showed equivalent diagnostic ability compared to Conv cine imaging (PEF AUC = 0.989, LAVmin AUC = 0.859) to differentiate between HV and HFrEF. CONCLUSION: Atrial volumetric and functional evaluation using CS cine imaging is feasible with relevant reduction of acquisition time, therefore strengthening the role of CS in clinical CMR for atrial imaging. KEY POINTS: • Reliable assessment of atrial volumes and function based on compressed sensing cine imaging is feasible. • Compressed sensing reduces scan time and has the potential to overcome obstacles of conventional cine imaging. • No significant differences for subjective image quality, inter- and intra-rater agreement, and ability to differentiate healthy volunteers and heart failure patients were detected between conventional and compressed sensing cine imaging.


Assuntos
Insuficiência Cardíaca , Aceleração , Átrios do Coração/diagnóstico por imagem , Humanos , Interpretação de Imagem Assistida por Computador , Imagem Cinética por Ressonância Magnética , Reprodutibilidade dos Testes , Volume Sistólico
8.
AJR Am J Roentgenol ; 217(2): 336-346, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-32936016

RESUMO

BACKGROUND. Transthoracic echocardiography (TTE) is the standard of care for initial evaluation of patients with suspected cardioembolic stroke. Although TTE is useful for assessing certain sources of cardiac emboli, its diagnostic capability is limited in the detection of other sources, including left atrial thrombus and aortic plaques. OBJECTIVE. The purpose of this article was to investigate sensitivity, specificity, and predictive value of cardiac CTA (CCTA), cardiac MRI (CMRI), and TTE for recurrence in patients with suspected cardioembolic stroke. METHODS. We retrospectively included 151 patients with suspected cardioembolic stroke who underwent TTE and either CMRI (n = 75) or CCTA (n = 76) between January 2013 and May 2017. We evaluated for the presence of left atrial thrombus, left ventricular thrombus, vulnerable aortic plaque, cardiac tumors, and valvular vegetation as causes of cardioembolic stroke. The end point was stroke recurrence. Sensitivity, specificity, PPV, and NPV for recurrent stroke were calculated; the diagnostic accuracy of CMRI, CCTA, and TTE was compared between and within groups using AUC. RESULTS. Twelve and 14 recurrent strokes occurred in the CCTA and CMRI groups, respectively. Sensitivity, specificity, PPV, and NPV were 33.3%, 93.7%, 50.0%, and 88.2% for CCTA; 14.3%, 80.3%, 14.3%, and 80.3% for CMRI; 14.3%, 83.6%, 16.7%, and 80.9% for TTE in the CMRI group; and 8.3%, 93.7%, 20.0%, and 84.5% for TTE in the CCTA group. Accuracy was not different (p > .05) between CCTA (AUC = 0.63; 95% CI, 0.49-0.77), CMRI (0.53; 95% CI, 0.42-0.63), TTE in the CMRI group (0.51; 95% CI, 0.40-0.61), and TTE in the CCTA group (0.51; 95% CI, 0.42-0.59). In the CCTA group, atrial and ventricular thrombus were detected by CCTA in three patients and TTE in one patient; in the CMRI group, thrombus was detected by CMRI in one patient and TTE in two patients. CONCLUSION. CCTA, CMRI, and TTE showed comparably high specificity and NPV for cardioembolic stroke recurrence. CCTA and CMRI may be valid alternatives to TTE. CCTA may be preferred given potentially better detection of atrial and ventricular thrombus. CLINICAL IMPACT. CCTA and CMRI have similar clinical performance as TTE for predicting cardioembolic stroke recurrence. This observation may be especially important when TTE provides equivocal findings.


Assuntos
Ecocardiografia/métodos , AVC Embólico/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Feminino , Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Recidiva , Estudos Retrospectivos , Sensibilidade e Especificidade
9.
J Thorac Imaging ; 36(6): 345-352, 2021 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-32205821

RESUMO

OBJECTIVES: Computed tomography (CT) myocardial perfusion imaging (CT-MPI) with hyperemia induced by regadenoson was evaluated for the detection of myocardial ischemia, safety, relative radiation exposure, and patient experience compared with single-photon emission computed tomography (SPECT) imaging. MATERIALS AND METHODS: Twenty-four patients (66.5 y, 29% male) who had undergone clinically indicated SPECT imaging and provided written informed consent were included in this phase II, IRB-approved, and FDA-approved clinical trial. All patients underwent coronary CT angiography and CT-MPI with hyperemia induced by the intravenous administration of regadenoson (0.4 mg/5 mL). Patient experience and findings on CT-MPI images were compared to SPECT imaging. RESULTS: Patient experience and safety were similar between CT-MPI and SPECT procedures and no serious adverse events due to the administration of regadenoson occurred. SPECT resulted in a higher number of mild adverse events than CT-MPI. Patient radiation exposure was similar during the combined coronary computed tomography angiography and CT-MPI (4.4 [2.7] mSv) and SPECT imaging (5.6 [1.7] mSv) (P-value 0.401) procedures. Using SPECT as the reference standard, CT-MPI analysis showed a sensitivity of 58.3% (95% confidence interval [CI]: 27.7-84.8), a specificity of 100% (95% CI: 73.5-100), and an accuracy of 79.1% (95% CI: 57.9-92.87). Low apparent sensitivity occurred when the SPECT defects were small and highly suspicious for artifacts. CONCLUSIONS: This study demonstrated that CT-MPI is safe, well tolerated, and can be performed with comparable radiation exposure to SPECT. CT-MPI has the benefit of providing both complete anatomic coronary evaluation and assessment of myocardial perfusion.


Assuntos
Doença da Artéria Coronariana , Imagem de Perfusão do Miocárdio , Angiografia Coronária , Estudos de Viabilidade , Feminino , Humanos , Masculino , Purinas , Pirazóis , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada por Raios X
10.
ESC Heart Fail ; 7(5): 2544-2552, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32790159

RESUMO

AIMS: The purpose of this retrospective single-centre study was to evaluate the non-invasive detection of endomyocardial biopsy (EMB)-established chronic myocardial inflammation in patients with heart failure with reduced ejection fraction (HFrEF) using T1 and T2 mapping. METHODS AND RESULTS: The study population consisted of 52 retrospectively identified HFrEF patients who underwent EMB and cardiac magnetic resonance imaging at 3 Tesla. EMB was defined according to the position statement of the European Society of Cardiology and served as reference to identify inflammation in all patients. A control group of healthy volunteers with prior cardiac magnetic resonance imaging studies (n = 58) was also identified. Global and segmental T1 and T2 values as well as septal measurements and tissue heterogeneity parameters were calculated. Out of the 52 patients with HFrEF, 33 patients had myocardial inflammation detected by EMB, while 19 patients were EMB negative for inflammation. Mean left ventricular ejection fraction was 31% in both groups (P = 0.97). Global T1 and T2 values in HFrEF patients were significantly higher compared with healthy controls (T1 1275 ± 69 ms vs. 1,175 ± 44 ms, P < 0.001; T2 40.0 ± 3.4 ms vs. 37.9 ± 1.6 ms, P < 0.001). The distribution of T1 and T2 values between patients with and without EMB-proven chronic myocardial inflammation was not statistically different when regarding global (T1 1292 ± 71 ms vs. 1266 ± 67 ms, P = 0.26; T2 40.0 ± 2.6 ms vs. 40.0 ± 3.9 ms, P = 1.0), septal (T1 1299 ± 63 ms vs. 1289 ± 76 ms, P = 0.76; T2 40.1 ± 3.5 ms vs 40.0 ± 6.4 ms, P = 0.49) or maximum segmental values (T1 1414 ± 111 ms vs. 1363 ± 88 ms, P = 0.15; T2 47.3 ± 5.2 ms vs. 48.8 ± 11.8 ms, P = 0.53). Mean absolute deviation of segmental T1 and T2 values and log-transformed pixel-wise standard deviation as parameters of tissue heterogeneity did not reveal statistical significant differences between inflammation-positive and inflammation-negative HFrEF patients (all P > 0.4). CONCLUSIONS: Conventionally performed quantitative T1 and T2 mapping values significantly correlated with prevalence of HFrEF but did not discriminate HFrEF patients with or without chronic myocardial inflammation in our cohort. This suggests that EMB is the preferred method to detect chronic myocardial inflammation in HFrEF.


Assuntos
Insuficiência Cardíaca , Insuficiência Cardíaca/diagnóstico , Humanos , Inflamação/diagnóstico , Imageamento por Ressonância Magnética , Imagem Cinética por Ressonância Magnética , Miocárdio , Valor Preditivo dos Testes , Estudos Retrospectivos , Volume Sistólico , Função Ventricular Esquerda
11.
J Thorac Imaging ; 35 Suppl 1: S28-S34, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32235188

RESUMO

OBJECTIVES: The objective of this study was to evaluate an artificial intelligence (AI)-based prototype algorithm for the fully automated per lobe segmentation and emphysema quantification (EQ) on chest-computed tomography as it compares to the Global Initiative for Chronic Obstructive Lung Disease (GOLD) severity classification of chronic obstructive pulmonary disease (COPD) patients. METHODS: Patients (n=137) who underwent chest-computed tomography acquisition and spirometry within 6 months were retrospectively included in this Institutional Review Board-approved and Health Insurance Portability and Accountability Act-compliant study. Patient-specific spirometry data, which included forced expiratory volume in 1 second, forced vital capacity, and the forced expiratory volume in 1 second/forced vital capacity ratio (Tiffeneau-Index), were used to assign patients to their respective GOLD stage I to IV. Lung lobe segmentation was carried out using AI-RAD Companion software prototype (Siemens Healthineers), a deep convolution image-to-image network and emphysema was quantified in each lung lobe to detect the low attenuation volume. RESULTS: A strong correlation between the whole-lung-EQ and the GOLD stages was found (ρ=0.88, P<0.0001). The most significant correlation was noted in the left upper lobe (ρ=0.85, P<0.0001), and the weakest in the left lower lobe (ρ=0.72, P<0.0001) and right middle lobe (ρ=0.72, P<0.0001). CONCLUSIONS: AI-based per lobe segmentation and its EQ demonstrate a very strong correlation with the GOLD severity stages of COPD patients. Furthermore, the low attenuation volume of the left upper lobe not only showed the strongest correlation to GOLD severity but was also able to most clearly distinguish mild and moderate forms of COPD. This is particularly relevant due to the fact that early disease processes often elude conventional pulmonary function diagnostics. Earlier detection of COPD is a crucial element for positively altering the course of disease progression through various therapeutic options.


Assuntos
Inteligência Artificial , Doença Pulmonar Obstrutiva Crônica/diagnóstico por imagem , Enfisema Pulmonar/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Fumantes/estatística & dados numéricos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Pulmão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Doença Pulmonar Obstrutiva Crônica/complicações , Enfisema Pulmonar/complicações , Radiografia Torácica/métodos , Estudos Retrospectivos , Índice de Gravidade de Doença , Adulto Jovem
13.
Radiology ; 293(2): 260-271, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31502938

RESUMO

In this article, the authors discuss the technical background and summarize the current body of literature regarding virtual monoenergetic (VM) images derived from dual-energy CT data, which can be reconstructed between 40 and 200 keV. Substantially improved iodine attenuation at lower kiloelectron volt levels and reduced beam-hardening artifacts at higher kiloelectron volt levels have been demonstrated from all major manufacturers of dual-energy CT units. Improved contrast attenuation with VM imaging at lower kiloelectron volt levels enables better delineation and diagnostic accuracy in the detection of various vascular or oncologic abnormalities. Low-kiloelectron-volt VM imaging may be useful for salvaging CT studies with suboptimal contrast material delivery or providing additional information on the arterial vasculature obtained from venous phase acquisitions. For patients with renal impairment, substantial reductions in the use of iodinated contrast material can be achieved by using lower-energy VM imaging. The authors recommend routine reconstruction of VM images at 50 keV when using dual-energy CT to exploit the increased contrast properties. For reduction of beam-hardening artifacts, VM imaging at 120 keV is useful for the initial assessment.


Assuntos
Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Artefatos , Doenças Cardiovasculares/diagnóstico por imagem , Estenose das Carótidas/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Meios de Contraste , Humanos , Neoplasias/diagnóstico por imagem , Artéria Pulmonar/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
14.
Int J Cardiol ; 281: 150-155, 2019 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-30738608

RESUMO

BACKGROUND: The noninvasive equilibrium contrast-enhanced cardiac computed tomography (CCT) has potential for myocardial tissue characterization. The objective of this study was to test the feasibility of CCT-based extracellular volume (ECV) fraction in beagle models of doxorubicin-induced interstitial myocardial fibrosis, with cardiac magnetic resonance (CMR) as the reference. METHODS: This study was approved by local ethics committee. Thirteen beagles were included with ECV quantified by CCT and CMR at baseline, 16 and 24 weeks after modeling. Spearman correlation analysis was used to determine the association between CT ECV, CMR ECV, collagen volume fraction (CVF), LVEF and serum fibrosis index (Hyaluronic acid [HA], Laminin [LN] and Type-III procollagen [PCIII]). RESULTS: Median ECV values in CT and CMR at 16 and 24 weeks were significantly higher than those at baseline (CT ECV: 34.4% and 37.7% vs. 25.2%; CMR ECV: 32.2% and 37.4% vs. 22.7%; P < 0.001). A strong correlation was found between CCT and CMR for ECV (r = 0.899, P < 0.001). Both correlated well with CVF (r = 0.951 and 0.879 for CT and MR ECV vs. CVF, P < 0.001), serum fibrosis index (r = 0.830-0.907 for CT and MR ECV vs. HA, LN, PCIII, respectively, P < 0.05) and were inversely related to LVEF (r = -0.846 and -0.804 for CCT and CMR, P < 0.001). Bland-Altman analysis showed a small bias (1.5%), with 95% limits of agreement of -2.7% and 5.6%. CONCLUSIONS: CCT-derived ECV correlates well with CMR, histology and serum fibrosis index, suggesting that CCT is capable of myocardial tissue characterization.


Assuntos
Cardiomiopatias/diagnóstico por imagem , Modelos Animais de Doenças , Doxorrubicina/toxicidade , Imagem Cinética por Ressonância Magnética/métodos , Miocárdio/patologia , Tomografia Computadorizada por Raios X/métodos , Animais , Antibióticos Antineoplásicos/toxicidade , Cardiomiopatias/induzido quimicamente , Cães , Feminino , Fibrose
15.
J Cardiovasc Comput Tomogr ; 13(1): 81-84, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30377090

RESUMO

ObjectiveTo assess the feasibility of dual energy CT (DECT) to derive myocardial extracellular volume (ECV) and detect myocardial ECV differences without a non-contrast acquisition, compared to single energy CT (SECT). MethodsSubjects (n = 35) with focal fibrosis (n = 17), diffuse fibrosis (n = 10), and controls (n = 9) underwent non-contrast and delayed acquisitions to calculate SECT-ECV. DECT-ECV was calculated using the delayed acquisition and the derived virtual non-contrast images. In the control and diffuse fibrotic groups, the entire myocardium of the left ventricle was used to calculate ECV. Two ROIs were placed in the focal fibrotic group, one in normal and one in fibrotic myocardium. ResultsMedian ECV was 33.4% (IQR, 30.1-37.4) using SECT and 34.9% (IQR, 31.2-39.2) using DECT (p = 0.401). For both techniques, focal and diffuse fibrosis had significantly higher ECV values (all p < 0.021) than normal myocardium. There was no systematic bias between DECT and SECT (p = 0.348). SECT had a higher radiation dose (1.1 mSv difference) than DECT (p < 0.001). ConclusionECV can be measured using a DECT approach with only a delayed acquisition. The DECT approach provides similar results at a lower radiation dose compared to SECT.


Assuntos
Cardiomiopatias/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Cardiomiopatias/patologia , Estudos de Casos e Controles , Meios de Contraste/administração & dosagem , Estudos de Viabilidade , Feminino , Fibrose , Humanos , Iohexol/administração & dosagem , Iohexol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Miocárdio/patologia , Valor Preditivo dos Testes , Doses de Radiação , Exposição à Radiação/efeitos adversos , Exposição à Radiação/prevenção & controle , Tomografia Computadorizada por Raios X/efeitos adversos
16.
Expert Rev Cardiovasc Ther ; 16(6): 441-453, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29734858

RESUMO

INTRODUCTION: Computed tomographic (CT) coronary artery calcium scoring (CAC) has been validated as a well-established screening method for cardiovascular risk stratification and treatment management that is used in addition to traditional risk factors. The purpose of this review is to present an update on current and future applications of CAC. Areas covered: The topic of CAC is summarized from its introduction to current application with focus on the validation and clinical integration including cardiovascular risk prediction and outcome, cost-effectiveness, impact on downstream medical testing, and the technical advances in scanner and software technology that are shaping the future of CAC. Furthermore, this review aims to provide guidance for the appropriate clinical use of CAC. Expert commentary: CAC is a well-established screening test in preventive care that is underused in daily clinical practice. The widespread clinical implementation of CAC will be decided by future technical advances in CT image acquisition, cost-effectiveness, and reimbursement status.


Assuntos
Cálcio/metabolismo , Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Vasos Coronários/patologia , Análise Custo-Benefício , Humanos , Medição de Risco/métodos , Fatores de Risco
17.
Eur Radiol ; 28(8): 3393-3404, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29460075

RESUMO

OBJECTIVES: To assess the image quality and diagnostic accuracy of a noise-optimized virtual monoenergetic imaging (VMI+) algorithm compared with standard virtual monoenergetic imaging (VMI) and linearly-blended (M_0.6) reconstructions for the detection of hypervascular liver lesions in dual-energy CT (DECT). METHODS: Thirty patients who underwent clinical liver MRI were prospectively enrolled. Within 60 days of MRI, arterial phase DECT images were acquired on a third-generation dual-source CT and reconstructed with M_0.6, VMI and VMI+ algorithms from 40 to 100 keV in 5-keV intervals. Liver parenchyma and lesion contrast-to-noise-ratios (CNR) were calculated. Two radiologists assessed image quality. Lesion sensitivity, specificity and area under the receiver operating characteristic curves (AUCs) were calculated for the three algorithms with MRI as the reference standard. RESULTS: VMI+ datasets from 40 to 60 keV provided the highest liver parenchyma and lesion CNR (p ≤0.021); 50 keV VMI+ provided the highest subjective image quality (4.40±0.54), significantly higher compared to VMI and M_0.6 (all p <0.001), and the best diagnostic accuracy in < 1-cm diameter lesions (AUC=0.833 vs. 0.777 and 0.749, respectively; p ≤0.003). CONCLUSIONS: 50-keV VMI+ provides superior image quality and diagnostic accuracy for the detection of hypervascular liver lesions with a diameter < 1cm compared to VMI or M_0.6 reconstructions. KEY POINTS: • Low-keV VMI+ are characterized by higher contrast resulting from maximum iodine attenuation. • VMI+ provides superior image quality compared with VMI or M_0.6. • 50-keV_VMI+ provides higher accuracy for the detection of hypervascular liver lesions < 1cm.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Neoplasias Hepáticas/irrigação sanguínea , Neoplasias Hepáticas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Algoritmos , Feminino , Humanos , Fígado/irrigação sanguínea , Fígado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Razão Sinal-Ruído
18.
Eur Radiol ; 28(7): 3097-3104, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29404770

RESUMO

OBJECTIVES: To investigate diagnostic accuracy and radiation dose of high-pitch CT coronary artery calcium scoring (CACS) with tin filtration (Sn100kVp) versus standard 120kVp high-pitch acquisition. METHODS: 78 patients (58% male, 61.5±9.1 years) were prospectively enrolled. Subjects underwent clinical 120kVp high-pitch CACS using third-generation dual-source CT followed by additional high-pitch Sn100kVp acquisition. Agatston scores, calcium volume scores, Agatston score categories, percentile-based risk categorization and radiation metrics were compared. RESULTS: 61/78 patients showed coronary calcifications. Median Agatston scores were 34.9 [0.7-197.1] and 41.7 [0.7-207.2] and calcium volume scores were 34.1 [0.7-218.0] for Sn100kVp and 35.7 [1.1-221.0] for 120kVp acquisitions, respectively (both p<0.0001). Bland-Altman analysis revealed underestimated Agatston scores and calcium volume scores with Sn100kVp versus 120kVp acquisitions (mean difference: 16.4 and 11.5). However, Agatston score categories and percentile-based risk categories showed excellent agreement (ĸ=0.98 and ĸ=0.99). Image noise was 25.8±4.4HU and 16.6±2.9HU in Sn100kVp and 120kVp scans, respectively (p<0.0001). Dose-length-product was 9.9±4.8mGy*cm and 40.9±14.4mGy*cm with Sn100kVp and 120kVp scans, respectively (p<0.0001). This resulted in significant effective radiation dose reduction (0.13±0.07mSv vs. 0.57±0.2mSv, p<0.0001) for Sn100kVp acquisitions. CONCLUSION: CACS using high-pitch low-voltage tin-filtered acquisitions demonstrates excellent agreement in Agatston score and percentile-based cardiac risk categorization with standard 120kVp high-pitch acquisitions. Furthermore, radiation dose was significantly reduced by 78% while maintaining accurate risk prediction. KEY POINTS: • Coronary artery calcium scoring with tin filtration reduces radiation dose by 78%. • There is excellent correlation between high-pitch Sn100kVp and standard 120kVp acquisitions. • Excellent agreement regarding Agatston score categories and percentile-based risk categorization was achieved. • No cardiac risk reclassifications were observed using Sn100kVp coronary artery calcium scoring.


Assuntos
Calcinose/diagnóstico por imagem , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Cálcio , Feminino , Filtração/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes , Medição de Risco/métodos , Estanho
19.
Int J Cardiovasc Imaging ; 34(6): 921-929, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29305739

RESUMO

To develop a quantitative T1-mapping-based synthetic inversion recovery (IRsynth) approach to calculate the optimal inversion time (TI0) for late gadolinium enhancement (LGE) imaging. Prospectively enrolled patients (n = 130, 58 ± 16 years) underwent cardiac MRI on a 1.5T system including Look-Locker TI-scout (LL), modified LL IR (MOLLI)-based T1-mapping, and LGE acquisitions. Patients were randomized into two groups: LL group (TI-scout followed T1-mapping) or MOLLI group (T1-mapping followed TI-scout). In both groups, the second acquisition was used to determine the TI0 for LGE. IRsynth images were generated from T1-maps between TI = 200-400 ms in 5 ms increments. Image quality was rated on a 3-point scale and the remote/background signal intensity ratio (SIR) was calculated. In the LL group (n = 53), the TI-scout-based TI0 was significantly shorter compared to IRsynth [230 ms (219-242) vs. 280 ms (263-297), P < 0.0001]. The TI0 used for LGE was set 30-40 ms longer [261 ms (247-276), P < 0.0001] than the TI-scout-based TI0, resulting in a TI0 ~ 20 ms shorter than what was obtained by IRsynth (P = 0.0156). In the MOLLI group (n = 63), IRsynth-based TI0 was significantly longer than the TI-scout-based TI0 [298 ms (262-334) vs. 242 ms (217-267), P = 0.0313]. The quality of myocardial nulling was rated higher [2.4 (2.2-2.5) vs. 2.0 (1.8-2.1), P = 0.0042] and the remote/background SIR was found to be more optimal (1.6 [1.1-2.1] vs. 2.6 [1.8-3.3], P = 0.0256) in the MOLLI group. T1-based IRsynth selects TI0 for LGE more accurately than conventional TI-scout imaging. IRsynth improves TI0 selection by providing excellent visualization of the representative image contrast for LGE images, reducing operator dependence in LGE acquisition.


Assuntos
Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Miocárdio/patologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Técnicas de Imagem Cardíaca/métodos , Técnicas de Imagem Cardíaca/normas , Doença Crônica , Meios de Contraste , Feminino , Gadolínio , Humanos , Imageamento por Ressonância Magnética/normas , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Fatores de Tempo , Adulto Jovem
20.
Eur J Radiol ; 91: 29-34, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28629567

RESUMO

OBJECTIVES: To investigate the diagnostic accuracy of CT coronary artery calcium scoring (CACS) with tin pre-filtration (Sn100kVp) using iterative beam-hardening correction (IBHC) calcium material reconstruction compared to the standard 120kVp acquisition. BACKGROUND: Third generation dual-source CT (DSCT) CACS with Sn100kVp acquisition allows significant dose reduction. However, the Sn100kVp spectrum is harder with lower contrast compared to 120kVp, resulting in lower calcium score values. Sn100kVp spectral correction using IBHC-based calcium material reconstruction may restore comparable calcium values. METHODS: Image data of 62 patients (56% male, age 63.9±9.2years) who underwent a clinically-indicated CACS acquisition using the standard 120kVp protocol and an additional Sn100kVp CACS scan as part of a research study were retrospectively analyzed. Datasets of the Sn100kVp scans were reconstructed using a dedicated spectral IBHC CACS reconstruction to restore the spectral response of 120kVp spectra. Agatston scores were derived from 120kVp and IBHC reconstructed Sn100kVp studies. Pearson's correlation coefficient was assessed and Agatston score categories and percentile-based risk categorization were compared. RESULTS: Median Agatston scores derived from IBHC Sn100kVp scans and 120kVp acquisition were 31.7 and 34.1, respectively (p=0.057). Pearson's correlation coefficient showed excellent correlation between the acquisitions (r=0.99, p<0.0001). Agatston score categories and percentile-based cardiac risk categories showed excellent agreement (ĸ=1.00 and ĸ=0.99), resulting in a low cardiac risk reclassification of 1.6% with the use of IBHC CACS reconstruction. Image noise was 24.9±3.6HU in IBHC Sn100kVp and 17.1±3.9HU in 120kVp scans (p<0.0001). The dose-length-product was 13.2±3.4mGycm with IBHC Sn100kVp and 59.1±22.9mGycm with 120kVp scans (p<0.0001), resulting in a significantly lower effective radiation dose (0.19±0.07mSv vs. 0.83±0.33mSv, p<0.0001) for IBHC Sn100kVp scans. CONCLUSION: Low voltage CACS with tin filtration using a dedicated IBHC CACS material reconstruction algorithm shows excellent correlation and agreement with the standard 120kVp acquisition regarding Agatston score and cardiac risk categorization, while radiation dose is significantly reduced by 75% to the level of a chest x-ray.


Assuntos
Calcinose/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Algoritmos , Cálcio , Feminino , Filtração , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Reprodutibilidade dos Testes , Estudos Retrospectivos , Estanho
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA