Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
2.
Magn Reson Med ; 85(5): 2608-2621, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33432613

RESUMO

PURPOSE: To enable motion-robust, ungated, free-breathing R2∗ mapping of hepatic iron overload in children with 3D multi-echo UTE cones MRI. METHODS: A golden-ratio re-ordered 3D multi-echo UTE cones acquisition was developed with chemical-shift encoding (CSE). Multi-echo complex-valued source images were reconstructed via gridding and coil combination, followed by confounder-corrected R2∗ (=1/ T2∗ ) mapping. A phantom containing 15 different concentrations of gadolinium solution (0-300 mM) was imaged at 3T. 3D multi-echo UTE cones with an initial TE of 0.036 ms and Cartesian CSE-MRI (IDEAL-IQ) sequences were performed. With institutional review board approval, 85 subjects (81 pediatric patients with iron overload + 4 healthy volunteers) were imaged at 3T using 3D multi-echo UTE cones with free breathing (FB cones), IDEAL-IQ with breath holding (BH Cartesian), and free breathing (FB Cartesian). Overall image quality of R2∗ maps was scored by 2 blinded experts and compared by a Wilcoxon rank-sum test. For each pediatric subject, the paired R2∗ maps were assessed to determine if a corresponding artifact-free 15 mm region-of-interest (ROI) could be identified at a mid-liver level on both images. Agreement between resulting R2∗ quantification from FB cones and BH/FB Cartesian was assessed with Bland-Altman and linear correlation analyses. RESULTS: ROI-based regression analysis showed a linear relationship between gadolinium concentration and R2∗ in IDEAL-IQ (y = 8.83x - 52.10, R2 = 0.995) as well as in cones (y = 9.19x - 64.16, R2 = 0.992). ROI-based Bland-Altman analysis showed that the mean difference (MD) was 0.15% and the SD was 5.78%. However, IDEAL-IQ R2∗ measurements beyond 200 mM substantially deviated from a linear relationship for IDEAL-IQ (y = 5.85x + 127.61, R2 = 0.827), as opposed to cones (y = 10.87x - 166.96, R2 = 0.984). In vivo, FB cones R2∗ had similar image quality with BH and FB Cartesian in 15 and 42 cases, respectively. FB cones R2∗ had better image quality scores than BH and FB Cartesian in 3 and 21 cases, respectively, where BH/FB Cartesian exhibited severe ghosting artifacts. ROI-based Bland-Altman analyses were 2.23% (MD) and 6.59% (SD) between FB cones and BH Cartesian and were 0.21% (MD) and 7.02% (SD) between FB cones and FB Cartesian, suggesting a good agreement between FB cones and BH (FB) Cartesian R2∗ . Strong linear relationships were observed between BH Cartesian and FB cones (y = 1.00x + 1.07, R2 = 0.996) and FB Cartesian and FB cones (y = 0.98x + 1.68, R2 = 0.999). CONCLUSION: Golden-ratio re-ordered 3D multi-echo UTE Cones MRI enabled motion-robust, ungated, and free-breathing R2∗ mapping of hepatic iron overload, with comparable R2∗ measurements and image quality to BH Cartesian, and better image quality than FB Cartesian.


Assuntos
Aumento da Imagem , Sobrecarga de Ferro , Criança , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Sobrecarga de Ferro/diagnóstico por imagem , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética , Respiração
3.
J Magn Reson Imaging ; 52(6): 1688-1698, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32452088

RESUMO

BACKGROUND: Quantitative T2 * MRI is the standard of care for the assessment of iron overload. However, patient motion corrupts T2 * estimates. PURPOSE: To develop and evaluate a motion-robust, simultaneous cardiac and liver T2 * imaging approach using non-Cartesian, rosette sampling and a model-based reconstruction as compared to clinical-standard Cartesian MRI. STUDY TYPE: Prospective. PHANTOM/POPULATION: Six ferumoxytol-containing phantoms (26-288 µg/mL). Eight healthy subjects and 18 patients referred for clinically indicated iron overload assessment. FIELD STRENGTH/SEQUENCE: 1.5T, 2D Cartesian and rosette gradient echo (GRE) ASSESSMENT: GRE T2 * values were validated in ferumoxytol phantoms. In healthy subjects, test-retest and spatial coefficient of variation (CoV) analysis was performed during three breathing conditions. Cartesian and rosette T2 * were compared using correlation and Bland-Altman analysis. Images were rated by three experienced radiologists on a 5-point scale. STATISTICAL TESTS: Linear regression, analysis of variance (ANOVA), and paired Student's t-testing were used to compare reproducibility and variability metrics in Cartesian and rosette scans. The Wilcoxon rank test was used to assess reader score comparisons and reader reliability was measured using intraclass correlation analysis. RESULTS: Rosette R2* (1/T2 *) was linearly correlated with ferumoxytol concentration (r2 = 1.00) and not significantly different than Cartesian values (P = 0.16). During breath-holding, ungated rosette liver and heart T2 * had lower spatial CoV (liver: 18.4 ± 9.3% Cartesian, 8.8% ± 3.4% rosette, P = 0.02, heart: 37.7% ± 14.3% Cartesian, 13.4% ± 1.7% rosette, P = 0.001) and higher-quality scores (liver: 3.3 [3.0-3.6] Cartesian, 4.7 [4.1-4.9] rosette, P = 0.005, heart: 3.0 [2.3-3] Cartesian, 4.5 [3.8-5.0] rosette, P = 0.005) compared to Cartesian values. During free-breathing and failed breath-holding, Cartesian images had very poor to average image quality with significant artifacts, whereas rosette remained very good, with minimal artifacts (P = 0.001). DATA CONCLUSION: Rosette k-sampling with a model-based reconstruction offers a clinically useful motion-robust T2 * mapping approach for iron quantification. J. MAGN. RESON. IMAGING 2020;52:1688-1698.


Assuntos
Óxido Ferroso-Férrico/análise , Coração/anatomia & histologia , Processamento de Imagem Assistida por Computador/métodos , Fígado/anatomia & histologia , Imageamento por Ressonância Magnética/métodos , Adulto , Artefatos , Feminino , Voluntários Saudáveis , Humanos , Masculino , Movimento (Física) , Imagens de Fantasmas , Estudos Prospectivos , Valores de Referência , Reprodutibilidade dos Testes
4.
Int J Cardiovasc Imaging ; 36(4): 657-669, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31894524

RESUMO

Lengthy exams and breath-holding limit the use of pediatric cardiac MRI (CMR). 3D time-resolved flow MRI (4DF) is a free-breathing, single-sequence exam that obtains magnitude (anatomic) and phase contrast (PC) data. We compare the accuracy of gadobenate dimeglumine-enhanced 4DF on a 1.5 T magnet to 2D CMR in children with repaired tetralogy of Fallot (rTOF) to measure pulmonary net flow (PNF) as a reflection of pulmonary regurgitation, forward flow (FF) and ventricular volumetry. Thirty-four consecutive cases were included. 2D PCs were obtained at the valve level. Using 4DF, we measured PNF at the valve and at the main and branch pulmonary arteries. PNF measured at the valve by 4DF demonstrated the strongest correlation (r = 0.87, p < 0.001) and lowest mean difference (3.5 ± 9.4 mL/beat) to aortic net flow (ANF). Semilunar FF and stroke volume of the respective ventricle demonstrated moderate-strong correlation by 4DF (r = 0.66-0.81, p < 0.001) and strong correlation by 2D (r = 0.81-0.84, p < 0.001) with similar correlations and mean differences between techniques (p > 0.05). Ventricular volumes correlated strongly between 2D and 4DF (r = 0.75-0.96, p < 0.001), though 4DF overestimated right ventricle volumes by 11.8-19.2 mL/beat. Inter-rater reliability was excellent for 2D and 4DF volumetry (ICC = 0.91-0.99). Ejection fraction moderately correlated (r = 0.60-0.75, p < 0.001) with better reliability by 4DF (ICC: 0.80-0.85) than 2D (ICC: 0.69-0.89). 4DF exams were shorter than 2D (9 vs. 71 min, p < 0.001). 4DF provides highly reproducible and accurate measurements of flow with slight overestimation of RV volumes compared to 2D in pediatric rTOF. 4DF offers important advantages in this population with long-term monitoring needs.


Assuntos
Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Ecocardiografia Quadridimensional , Imageamento por Ressonância Magnética , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/diagnóstico por imagem , Volume Sistólico , Tetralogia de Fallot/cirurgia , Função Ventricular Esquerda , Função Ventricular Direita , Adolescente , Velocidade do Fluxo Sanguíneo , Criança , Meios de Contraste/administração & dosagem , Feminino , Humanos , Masculino , Meglumina/administração & dosagem , Meglumina/análogos & derivados , Variações Dependentes do Observador , Compostos Organometálicos/administração & dosagem , Valor Preditivo dos Testes , Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/fisiopatologia , Reprodutibilidade dos Testes , Estudos Retrospectivos , Tetralogia de Fallot/fisiopatologia , Resultado do Tratamento , Adulto Jovem
5.
Curr Probl Diagn Radiol ; 49(3): 173-176, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31126664

RESUMO

BACKGROUND: Prostate imaging reporting and data system version 2 (PI-RADS v2) relegates dynamic contrast enhanced (DCE) imaging to a minor role. We sought to determine how often DCE is used in PI-RADS v2 scoring. MATERIALS AND METHODS: We retrospectively reviewed data from 388 patients who underwent prostate magnetic resonance imaging and subsequent biopsy from January 2016 through December 2017. In accordance with PI-RADS v2, DCE was deemed necessary if a peripheral-zone lesion had a diffusion-weighted imaging score of 3, or if a transition-zone lesion had a T2 score of 3 and diffusion-weighted imaging experienced technical failure. Receiver operating characteristic curve analysis assessed the accuracy of prostate-specific antigen density (PSAD) at different threshold values for differentiating lesions that would be equivocal with noncontrast technique. Accuracy of PSAD was compared to DCE using McNemar's test. RESULTS: Sixty-nine lesions in 62 patients (16%) required DCE for PI-RADS scoring. Biopsy of 10 (14%) of these lesions showed clinically significant cancer (Gleason score ≥7). In the subgroup of patients with equivocal lesions, those with clinically significant cancer had significantly higher PSADs than those with clinically insignificant lesions (means of 0.18 and 0.13 ng/mL/mL, respectively; P= 0.038). In this subgroup, there was no statistical difference in accuracy in determining clinically significant cancer between a PSAD threshold value of 0.13 and DCE (P= 0.25). CONCLUSIONS: Only 16% of our patients needed DCE to generate the PI-RADS version 2 score, raising the possibility of limiting the initial screening prostate MRI to a noncontrast exam. PSAD may also be used to further decrease the need for or to replace DCE altogether.


Assuntos
Meios de Contraste , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Neoplasias da Próstata/diagnóstico por imagem , Sistemas de Informação em Radiologia/estatística & dados numéricos , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia , Humanos , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Próstata/diagnóstico por imagem , Próstata/patologia , Neoplasias da Próstata/patologia , Reprodutibilidade dos Testes , Estudos Retrospectivos
6.
Mol Imaging Biol ; 22(2): 397-406, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31236756

RESUMO

PURPOSE: The purpose of this study is to prospectively evaluate the performance of sodium 18F]fluoride (Na[18F]F)/2-deoxy-2-[18F]fluoro-D-glucose ([18F]FDG) simultaneous time-of-flight enabled positron emission tomography (PET)/magnetic resonance imaging (MRI) for the detection of skeletal metastases in selected patients with advanced breast and prostate cancers. PROCEDURE: The institutional review board approved this HIPAA-compliant protocol. Written informed consent was obtained from each patient. A total of 74 patients (23 women and 51 men with breast and prostate cancer, respectively) referred for standard-of-care whole-body bone scintigraphy (WBBS) were enrolled in this prospective study. All patients underwent a [99mTc]methyldiphosphonate ([99mTc]MDP) WBBS followed by Na[18F]F/[18F]FDG PET/MRI. Lesions detected by each imaging modality were tabulated and a lesion-based and patient-based analysis was conducted. RESULTS: On a patient-based analysis, [99mTc]MDP WBBS identified skeletal lesions in 37 patients and PET/MRI in 45 patients. On a lesion-based analysis, WBBS identified a total of 81 skeletal lesions, whereas PET/MRI identified 140 lesions. Additionally, PET/MRI showed extra-skeletal lesions in 19 patients, including lymph nodes (16), prostate (4) lung (3), and liver (2) lesions. CONCLUSIONS: The ability of Na[18F]F/[18F]FDG PET/MRI to identify more skeletal lesions than 99mTc-MDP WBBS and to additionally identify extra-skeletal disease may be beneficial for patient care and represent an alternative to the single modalities performed separately. Na[18F]F/[18F]FDG PET/MRI is a promising approach for evaluation of skeletal and extra-skeletal lesions in a selected population of breast and prostate cancer patients.


Assuntos
Neoplasias Ósseas/diagnóstico por imagem , Neoplasias da Mama/diagnóstico por imagem , Fluordesoxiglucose F18 , Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons , Neoplasias da Próstata/diagnóstico por imagem , Fluoreto de Sódio , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias Ósseas/secundário , Neoplasias da Mama/patologia , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Imagem Multimodal/métodos , Estudos Prospectivos , Neoplasias da Próstata/patologia , Cintilografia , Compostos Radiofarmacêuticos , Sódio , Medronato de Tecnécio Tc 99m , Imagem Corporal Total
7.
Aging Cell ; 18(6): e13028, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31496122

RESUMO

Epigenetic "clocks" can now surpass chronological age in accuracy for estimating biological age. Here, we use four such age estimators to show that epigenetic aging can be reversed in humans. Using a protocol intended to regenerate the thymus, we observed protective immunological changes, improved risk indices for many age-related diseases, and a mean epigenetic age approximately 1.5 years less than baseline after 1 year of treatment (-2.5-year change compared to no treatment at the end of the study). The rate of epigenetic aging reversal relative to chronological age accelerated from -1.6 year/year from 0-9 month to -6.5 year/year from 9-12 month. The GrimAge predictor of human morbidity and mortality showed a 2-year decrease in epigenetic vs. chronological age that persisted six months after discontinuing treatment. This is to our knowledge the first report of an increase, based on an epigenetic age estimator, in predicted human lifespan by means of a currently accessible aging intervention.


Assuntos
Envelhecimento/genética , Epigênese Genética/genética , Imunossenescência , Idoso , Voluntários Saudáveis , Humanos , Longevidade , Masculino , Pessoa de Meia-Idade
8.
J Magn Reson Imaging ; 49(7): e271-e281, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30614145

RESUMO

BACKGROUND: Pelvic ultrasound (US) diagnosis of uterine fibroids may overlook coexisting gynecological conditions that contribute to women's symptoms. PURPOSE: To determine the added value of pelvic MRI for women diagnosed with symptomatic fibroids by US, and to identify clinical factors associated with additional MRI findings. STUDY TYPE: Retrospective observational study. POPULATION: In all, 367 consecutive women with fibroids diagnosed by US and referred to our multidisciplinary fibroid center between 2013-2017. FIELD STRENGTH/SEQUENCE: All patients had both pelvic US and MRI prior to their consultations. MRIs were performed at 1.5 T or 3 T and included multiplanar T2 -weighted sequences, and precontrast and postcontrast T1 -weighted imaging. ASSESSMENT: Demographics, symptoms, uterine fibroid symptom severity scores, and health-related quality of life scores, as well as imaging findings were evaluated. STATISTICAL TESTS: Patients were separated into two subgroups according to whether MRI provided additional findings to the initial US. Univariate and multivariate regression analyses were performed. RESULTS: Pelvic MRI provided additional information in 162 patients (44%; 95% confidence interval [CI] 39-49%). The most common significant findings were adenomyosis (22%), endometriosis (17%), and partially endocavitary fibroids (15%). Women with pelvic pain, health-related quality of life scores less than 30 out of 100, or multiple fibroids visualized on US had greater odds of additional MRI findings (odds ratio [OR] 1.68, 2.26, 1.63; P = 0.02, 0.004, 0.03, respectively), while nulliparous women had reduced odds (OR 0.55, P = 0.01). Patients with additional MRI findings were treated less often with uterine fibroid embolization (14% vs. 36%, P < 0.001) or MR-guided focused US (1% vs. 5%, P = 0.04), and more often with medical management (17% vs. 8%, P = 0.01). DATA CONCLUSION: Pelvic MRI revealed additional findings in more than 40% of women presenting with symptoms initially ascribed to fibroids by US. Further evaluation using MRI is particularly useful for parous women with pelvic pain, poor quality of life scores, and/or multiple fibroids. LEVEL OF EVIDENCE: 4 Technical Efficacy: Stage 3 J. Magn. Reson. Imaging 2019.


Assuntos
Leiomioma/diagnóstico por imagem , Imageamento por Ressonância Magnética , Adenomiose/diagnóstico por imagem , Adulto , Endometriose/diagnóstico por imagem , Feminino , Humanos , Pessoa de Meia-Idade , Análise Multivariada , Qualidade de Vida , Estudos Retrospectivos , Ultrassonografia
9.
J Magn Reson Imaging ; 49(4): 984-993, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30390358

RESUMO

BACKGROUND: View-sharing (VS) increases spatiotemporal resolution in dynamic contrast-enhanced (DCE) MRI by sharing high-frequency k-space data across temporal phases. This temporal sharing results in respiratory motion within any phase to propagate artifacts across all shared phases. Compressed sensing (CS) eliminates the need for VS by recovering missing k-space data from pseudorandom undersampling, reducing temporal blurring while maintaining spatial resolution. PURPOSE: To evaluate a CS reconstruction algorithm on undersampled DCE-MRI data for image quality and hepatocellular carcinoma (HCC) detection. STUDY TYPE: Retrospective. SUBJECTS: Fifty consecutive patients undergoing MRI for HCC screening (29 males, 21 females, 52-72 years). FIELD STRENGTH/SEQUENCE: 3.0T MRI. Multiphase 3D-SPGR T1 -weighted sequence undersampled in arterial phases with a complementary Poisson disc sampling pattern reconstructed with VS and CS algorithms. ASSESSMENT: VS and CS reconstructions evaluated by blinded assessments of image quality and anatomic delineation on Likert scales (1-4 and 1-5, respectively), and HCC detection by OPTN/UNOS criteria including a diagnostic confidence score (1-5). Blinded side-by-side reconstruction comparisons for lesion depiction and overall series preference (-3-3). STATISTICAL ANALYSIS: Two-tailed Wilcoxon signed rank tests for paired nonparametric analyses with Bonferroni-Holm multiple-comparison corrections. McNemar's test for differences in lesion detection frequency and transplantation eligibility. RESULTS: CS compared with VS demonstrated significantly improved contrast (mean 3.6 vs. 2.9, P < 0.0001) and less motion artifact (mean 3.6 vs. 3.2, P = 0.006). CS compared with VS demonstrated significantly improved delineations of liver margin (mean 4.5 vs. 3.8, P = 0.0002), portal veins (mean 4.5 vs. 3.7, P < 0.0001), and hepatic veins (mean 4.6 vs. 3.5, P < 0.0001), but significantly decreased delineation of hepatic arteries (mean 3.2 vs. 3.7, P = 0.004). No significant differences were seen in the other assessments. DATA CONCLUSION: Applying a CS reconstruction to data acquired for a VS reconstruction significantly reduces motion artifacts in a clinical DCE protocol for HCC screening. LEVEL OF EVIDENCE: 3 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019;49:984-993.


Assuntos
Artefatos , Carcinoma Hepatocelular/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Imageamento por Ressonância Magnética , Idoso , Algoritmos , Meios de Contraste , Compressão de Dados , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Variações Dependentes do Observador , Reconhecimento Automatizado de Padrão , Respiração , Estudos Retrospectivos
10.
J Neurosurg Pediatr ; 22(3): 251-260, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29882734

RESUMO

OBJECTIVE Patients with brain arteriovenous malformations (AVMs) often require repeat imaging with MRI or MR angiography (MRA), CT angiography (CTA), and digital subtraction angiography (DSA). The ideal imaging modality provides excellent vascular visualization without incurring added risks, such as radiation exposure. The purpose of this study is to evaluate the performance of ferumoxytol-enhanced MRA using a high-resolution 3D volumetric sequence (fe-SPGR) for visualizing and grading pediatric brain AVMs in comparison with CTA and DSA, which is the current imaging gold standard. METHODS In this retrospective cohort study, 21 patients with AVMs evaluated by fe-SPGR, CTA, and DSA between April 2014 and August 2017 were included. Two experienced raters graded AVMs using Spetzler-Martin criteria on all imaging studies. Lesion conspicuity (LC) and diagnostic confidence (DC) were assessed using a 5-point Likert scale, and interrater agreement was determined. The Kruskal-Wallis test was performed to assess the raters' grades and scores of LC and DC, with subsequent post hoc pairwise comparisons to assess for statistically significant differences between pairs of groups at p < 0.05. RESULTS Assigned Spetzler-Martin grades for AVMs on DSA, fe-SPGR, and CTA were not significantly different (p = 0.991). LC and DC scores were higher with fe-SPGR than with CTA (p < 0.05). A significant difference in LC scores was found between CTA and fe-SPGR (p < 0.001) and CTA and DSA (p < 0.001) but not between fe-SPGR and DSA (p = 0.146). A significant difference in DC scores was found among DSA, fe-SPGR, and CTA (p < 0.001) and between all pairs of the groups (p < 0.05). Interrater agreement was good to very good for all image groups (κ = 0.77-1.0, p < 0.001). CONCLUSIONS Fe-SPGR performed robustly in the diagnostic evaluation of brain AVMs, with improved visual depiction of AVMs compared with CTA and comparable Spetzler-Martin grading relative to CTA and DSA.


Assuntos
Encéfalo/efeitos dos fármacos , Encéfalo/diagnóstico por imagem , Óxido Ferroso-Férrico/farmacocinética , Hematínicos/farmacocinética , Malformações Arteriovenosas Intracranianas/diagnóstico por imagem , Angiografia por Ressonância Magnética/métodos , Adolescente , Angiografia Digital , Criança , Pré-Escolar , Meios de Contraste/farmacocinética , Relação Dose-Resposta a Droga , Feminino , Humanos , Imageamento Tridimensional , Masculino , Estudos Retrospectivos , Adulto Jovem
11.
J Magn Reson Imaging ; 48(4): 1147-1158, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29638024

RESUMO

BACKGROUND: In patients with mitral or tricuspid valve regurgitation, evaluation of regurgitant severity is essential for determining the need for surgery. While transthoracic echocardiography is widely accessible, it has limited reproducibility for grading inlet valve regurgitation. Multiplanar cardiac MRI is the quantitative standard but requires specialized local expertise, and is thus not widely available. Volumetric 4D flow MRI has potential for quantitatively grading the severity of inlet valve regurgitation in adult patients. PURPOSE: To evaluate the accuracy and reproducibility of volumetric 4D flow MRI for quantification of inlet valvular regurgitation compared to conventional multiplanar MRI, which may simplify and improve accessibility of cardiac MRI. STUDY TYPE: This retrospective, HIPAA-compliant imaging-based comparison study was conducted at a single institution. SUBJECTS: Twenty-one patients who underwent concurrent multiplanar and 4D flow cardiac MRI between April 2015 and January 2017. FIELD STRENGTH/SEQUENCES: 3T; steady-state free-precession (SSFP), 2D phase contrast (2D-PC), and postcontrast 4D flow. ASSESSMENT: We evaluated the intertechnique (4D flow vs. 2D-PC), intermethod (direct vs. indirect measurement), interobserver and intraobserver reproducibility of measurements of regurgitant flow volume (RFV), fraction (RF), and volume (RVol). STATISTICAL TESTS: Statistical analysis included Pearson correlation, Bland-Altman statistics, and intraclass correlation coefficients. RESULTS: There was high concordance between 4D flow and multiplanar MRI, whether using direct or indirect methods of quantifying regurgitation (r = 0.813-0.985). Direct interrogation of the regurgitant jet with 4D flow showed high intraobserver consistency (r = 0.976-0.999) and interobserver consistency (r = 0.861-0.992), and correlated well with traditional indirect measurements obtained as the difference between stroke volume and forward outlet valve flow. DATA CONCLUSION: 4D flow MRI provides highly reproducible measurements of mitral and tricuspid regurgitant volume, and may be used in place of conventional multiplanar MRI. LEVEL OF EVIDENCE: 4 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;48:1147-1158.


Assuntos
Imageamento Tridimensional , Imageamento por Ressonância Magnética , Insuficiência da Valva Mitral/diagnóstico por imagem , Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Velocidade do Fluxo Sanguíneo , Feminino , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Estudos Retrospectivos , Volume Sistólico , Fatores de Tempo , Adulto Jovem
12.
Sci Rep ; 8(1): 3409, 2018 02 21.
Artigo em Inglês | MEDLINE | ID: mdl-29467370

RESUMO

To evaluate the performance of computed high b value diffusion-weighted images (DWI) in prostate cancer detection. 97 consecutive patients who had undergone multiparametric MRI of the prostate followed by biopsy were reviewed. Five radiologists independently scored 138 lesions on native high b-value images (b = 1200 s/mm2), apparent diffusion coefficient (ADC) maps, and computed high b-value images (contrast equivalent to b = 2000 s/mm2) to compare their diagnostic accuracy. Receiver operating characteristic (ROC) analysis and McNemar's test were performed to assess the relative performance of computed high b value DWI, native high b-value DWI and ADC maps. No significant difference existed in the area under the curve (AUC) for ROCs comparing B1200 (b = 1200 s/mm2) to computed B2000 (c-B2000) in 5 readers. In 4 of 5 readers c-B2000 had significantly increased sensitivity and/or decreased specificity compared to B1200 (McNemar's p < 0.05), at selected thresholds of interpretation. ADC maps were less accurate than B1200 or c-B2000 for 2 of 5 readers (P < 0.05). This study detected no consistent improvement in overall diagnostic accuracy using c-B2000, compared with B1200 images. Readers detected more cancer with c-B2000 images (increased sensitivity) but also more false positive findings (decreased specificity).


Assuntos
Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico , Idoso , Área Sob a Curva , Imagem de Difusão por Ressonância Magnética/métodos , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Biópsia Guiada por Imagem/métodos , Masculino , Pessoa de Meia-Idade , Próstata/diagnóstico por imagem , Curva ROC , Estudos Retrospectivos , Sensibilidade e Especificidade
13.
Abdom Radiol (NY) ; 43(3): 593-599, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28689221

RESUMO

PURPOSE: To evaluate acquisition time and clinical image quality of a variable refocusing flip angle (vrf) single-shot fast spin echo (SSFSE) sequence in comparison with a conventional SSFSE sequence for imaging of liver lesions in patients undergoing whole-body PET/MRI for oncologic staging. METHODS: A vrfSSFSE sequence was acquired in 43 patients with known pancreatic neuroendocrine tumors undergoing 68Ga-DOTA-TOC PET on a simultaneous time-of-flight 3.0T PET/MRI. Liver lesions ≥1.5 cm with radionucleotide uptake were analyzed. Contrast-to-noise ratios (CNRs) were measured, and four blinded radiologists assessed overall image quality. Differences in repetition time and CNR were assessed using a paired Student's t test with p < 0.05 considered statistically significant. Inter-reader variability was assessed with Fleiss' kappa statistic. RESULTS: 53 eligible lesions in 27 patients were included for analysis. vrfSSFSE demonstrated higher mean lesion CNR compared to SSFSE (9.9 ± 4.1 vs. 6.7 ± 4.1, p < 0.001). Mean repetition time (TR) was 679 ± 97 ms for the vrfSSFSE sequence compared to 1139 ± 106 ms for SSFSE (p < 0.0001), corresponding to a 1.7-fold decrease in acquisition time. Overall quality of liver lesion and common bile duct images with the vrfSSFSE sequence was graded as superior than or equivalent to the SSFSE sequence for 59% and 67% of patients, respectively. CONCLUSIONS: Compared to conventional SSFSE, vrfSSFSE resulted in improved lesion contrast on simultaneous PET/MRI in patients with liver metastases. Due to decreased SAR demands, vrfSSFSE significantly decreased TR, allowing coverage of the entire liver in a single twenty-second breath hold. This may have important clinical implications in the setting of PET/MRI, where scan time is limited by the necessity of whole-body image acquisition in addition to bed specific imaging.


Assuntos
Aumento da Imagem/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Imagem Multimodal , Tumores Neuroendócrinos/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Adulto , Idoso , Imagem Ecoplanar/métodos , Feminino , Compostos Heterocíclicos , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Neoplasias Hepáticas/secundário , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Tumores Neuroendócrinos/secundário , Compostos Organometálicos , Neoplasias Pancreáticas/patologia , Compostos Radiofarmacêuticos
14.
AJR Am J Roentgenol ; 210(1): 189-200, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29090998

RESUMO

OBJECTIVE: We report here an initial experience using 4D flow MRI in pelvic imaging-specifically, in imaging uterine fibroids. We hypothesized that blood flow might correlate with fibroid volume and that quantifying blood flow might help to predict the amount of embolic required to achieve stasis at subsequent uterine fibroid embolization (UFE). MATERIALS AND METHODS: Thirty-three patients with uterine fibroids and seven control subjects underwent pelvic MRI with 4D flow imaging. Of the patients with fibroids, 10 underwent 4D flow imaging before UFE and seven after UFE; in the remaining 16 patients with fibroids, UFE had yet to be performed. Four-dimensional flow measurements were performed using Arterys CV Flow. The flow fraction of the internal iliac artery was expressed as the ratio of internal iliac artery flow to external iliac artery flow and was compared between groups. The flow ratios between the internal iliac arteries on each side were calculated. Fibroid volume versus internal iliac flow fraction, embolic volume versus internal iliac flow fraction, and embolic volume ratio between sides versus the ratio of internal iliac artery flows between sides were compared. RESULTS: The mean internal iliac flow fraction was significantly higher in the 26 patients who underwent imaging before UFE (mean ± standard error, 0.78 ± 0.06) than in the seven patients who underwent imaging after UFE (0.48 ± 0.07, p < 0.01) and in the seven control patients without fibroids (0.48 ± 0.08, p < 0.0001). The internal iliac flow fraction correlated well with fibroid volumes before UFE (r = 0.7754, p < 0.0001) and did not correlate with fibroid volumes after UFE (r = -0.3051, p = 0.51). The ratio of embolic required to achieve stasis between sides showed a modest correlation with the ratio of internal iliac flow (r = 0.6776, p = 0.03). CONCLUSION: Internal iliac flow measured by 4D flow MRI correlates with fibroid volume and is predictive of the ratio of embolic required to achieve stasis on each side at subsequent UFE and may be useful for preprocedural evaluation of patients with uterine fibroids.


Assuntos
Embolização Terapêutica , Leiomioma/diagnóstico por imagem , Leiomioma/terapia , Pelve/irrigação sanguínea , Neoplasias Uterinas/diagnóstico por imagem , Neoplasias Uterinas/terapia , Adulto , Feminino , Humanos , Aumento da Imagem , Angiografia por Ressonância Magnética , Pessoa de Meia-Idade , Projetos Piloto , Valor Preditivo dos Testes , Estudos Retrospectivos , Resultado do Tratamento
15.
Kidney Int ; 92(1): 47-66, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28434822

RESUMO

Contrast-enhanced magnetic resonance imaging is a commonly used diagnostic tool. Compared with standard gadolinium-based contrast agents, ferumoxytol (Feraheme, AMAG Pharmaceuticals, Waltham, MA), used as an alternative contrast medium, is feasible in patients with impaired renal function. Other attractive imaging features of i.v. ferumoxytol include a prolonged blood pool phase and delayed intracellular uptake. With its unique pharmacologic, metabolic, and imaging properties, ferumoxytol may play a crucial role in future magnetic resonance imaging of the central nervous system, various organs outside the central nervous system, and the cardiovascular system. Preclinical and clinical studies have demonstrated the overall safety and effectiveness of this novel contrast agent, with rarely occurring anaphylactoid reactions. The purpose of this review is to describe the general and organ-specific properties of ferumoxytol, as well as the advantages and potential pitfalls associated with its use in magnetic resonance imaging. To more fully demonstrate the applications of ferumoxytol throughout the body, an imaging atlas was created and is available online as supplementary material.


Assuntos
Meios de Contraste/administração & dosagem , Óxido Ferroso-Férrico/administração & dosagem , Imageamento por Ressonância Magnética/métodos , Adolescente , Adulto , Animais , Atlas como Assunto , Pré-Escolar , Meios de Contraste/efeitos adversos , Meios de Contraste/farmacocinética , Feminino , Óxido Ferroso-Férrico/efeitos adversos , Óxido Ferroso-Férrico/farmacocinética , Hematínicos/administração & dosagem , Humanos , Rim/fisiopatologia , Imageamento por Ressonância Magnética/efeitos adversos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Eliminação Renal , Insuficiência Renal Crônica/fisiopatologia , Reprodutibilidade dos Testes
16.
Radiology ; 282(2): 561-568, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27564132

RESUMO

Purpose To assess image quality and speed improvements for single-shot fast spin-echo (SSFSE) with variable refocusing flip angles and full-Fourier acquisition (vrfSSFSE) pelvic imaging via a prospective trial performed in the context of uterine leiomyoma evaluation. Materials and Methods Institutional review board approval and informed consent were obtained. vrfSSFSE and conventional SSFSE sagittal and coronal oblique acquisitions were performed in 54 consecutive female patients referred for 3-T magnetic resonance (MR) evaluation of known or suspected uterine leiomyomas. Two radiologists who were blinded to the image acquisition technique semiquantitatively scored images on a scale from -2 to 2 for noise, image contrast, sharpness, artifacts, and perceived ability to evaluate uterine, ovarian, and musculoskeletal structures. The null hypothesis of no significant difference between pulse sequences was assessed with a Wilcoxon signed rank test by using a Holm-Bonferroni correction for multiple comparisons. Results Because of reductions in specific absorption rate, vrfSSFSE imaging demonstrated significantly increased speed (more than twofold, P < .0001), with mean repetition times compared with conventional SSFSE imaging decreasing from 1358 to 613 msec for sagittal acquisitions and from 1494 to 621 msec for coronal oblique acquisitions. Almost all assessed image quality and perceived diagnostic capability parameters were significantly improved with vrfSSFSE imaging. These improvements included noise, sharpness, and ability to evaluate the junctional zone, myometrium, and musculoskeletal structures for both sagittal acquisitions (mean values of 0.56, 0.63, 0.42, 0.56, and 0.80, respectively; all P values < .0001) and coronal oblique acquisitions (mean values of 0.81, 1.09, 0.65, 0.93, and 1.12, respectively; all P values < .0001). For evaluation of artifacts, there was an insufficient number of cases with differences to allow statistical testing. Conclusion Compared with conventional SSFSE acquisition, vrfSSFSE acquisition increases 3-T imaging speed via reduced specific absorption rate and leads to significant improvements in perceived image quality and perceived diagnostic capability when evaluating pelvic structures. © RSNA, 2016 Online supplemental material is available for this article.


Assuntos
Aumento da Imagem/métodos , Leiomioma/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Neoplasias Uterinas/diagnóstico por imagem , Artefatos , Imagem Ecoplanar/métodos , Feminino , Análise de Fourier , Humanos , Pessoa de Meia-Idade , Pelve/diagnóstico por imagem
17.
Magn Reson Med ; 77(1): 209-220, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-26778549

RESUMO

PURPOSE: To develop a technique for high-resolution diffusion-weighted imaging (DWI) and to compare it with standard DWI methods. METHODS: Multiple in-plane bands of magnetization were simultaneously excited by identically phase modulating each subpulse of a two-dimensional (2D) RF pulse. Several excitations with the same multiband pattern progressively shifted in the phase-encode direction were used to cover the prescribed field of view (FOV). The phase-encoded FOV was limited to the width of a single band to reduce off-resonance-induced distortion and blurring. Parallel imaging (PI) techniques were used to resolve aliasing from the other bands and to combine the different excitations. Following validation in phantoms and healthy volunteers, a preliminary study in breast cancer patients (N=14) was performed to compare the proposed method to conventional DWI with PI and to reduced-FOV DWI. RESULTS: The proposed method gave high-resolution diffusion-weighted images with minimal artifacts at the band intersections. Compared to PI alone, higher phase-encoded FOV-reduction factors and reduced noise amplification were obtained, which translated to higher resolution images than conventional (non-multiband) DWI. The same resolution and image quality achievable over targeted regions using existing reduced-FOV methods was obtained, but the proposed method also enables complete bilateral coverage. CONCLUSION: We developed an in-plane multiband technique for high-resolution DWI and compared its performance with other standard DWI methods. Magn Reson Med 77:209-220, 2017. © 2016 Wiley Periodicals, Inc.


Assuntos
Mama/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Interpretação de Imagem Assistida por Computador/métodos , Adulto , Idoso , Neoplasias da Mama/diagnóstico por imagem , Feminino , Humanos , Pessoa de Meia-Idade , Imagens de Fantasmas , Ondas de Rádio , Reprodutibilidade dos Testes , Adulto Jovem
18.
Magn Reson Med ; 75(5): 2107-11, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26890830

RESUMO

Ferumoxytol is an ultrasmall superparamagnetic iron oxide agent marketed for the treatment of anemia. There has been increasing interest in its properties as an MRI contrast agent as well as greater awareness of its adverse event profile. This mini-review summarizes the current state of knowledge of the risks of ferumoxytol and methods of administration.


Assuntos
Óxido Ferroso-Férrico/administração & dosagem , Imageamento por Ressonância Magnética , Neoplasias/diagnóstico por imagem , Neoplasias/patologia , Ensaios Clínicos como Assunto , Meios de Contraste/química , Compostos Férricos/química , Óxido Ferroso-Férrico/efeitos adversos , Óxido Ferroso-Férrico/química , Gadolínio/química , Humanos , Iodo/química , Macrófagos/metabolismo , Metástase Neoplásica , Segurança do Paciente , Perfusão
19.
J Magn Reson Imaging ; 43(4): 859-65, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26340309

RESUMO

PURPOSE: To assess the ability of high-resolution arterial phase imaging of hepatocellular carcinoma (HCC) to provide combined vascular characterization and parenchymal evaluation. MATERIALS AND METHODS: Thirty-eight consecutive studies in cirrhotic patients with HCC scanned with a view-shared 2-point-Dixon-based Differential Subsampling with Cartesian Ordering (DISCO) sequence were analyzed. Lesion contrast relative to precontrast and adjacent parenchyma was evaluated and compared using a Fisher's exact test. Visibility of hepatic arteries and tumor feeding vessels were graded on a 5-point scale. Catheter angiography was used as a reference standard for arterial anatomy. RESULTS: The high spatiotemporal multiphasic acquisition allowed imaging of both the angiographic and late arterial phase in 30 of 38 studies with good image quality. Maximal lesion enhancement compared to precontrast occurred more frequently during the late arterial phase compared to maximal lesion-to-adjacent, which occurred more frequently during the early arterial phase (P < 0.001). Common and proper hepatic arteries were visualized adequately in 100%, right hepatic artery in 94-97%, left hepatic artery in 94%, and segmental vessel in 83% of cases. Arterial variants were detected with sensitivity of 87-100% and specificity of 100%. CONCLUSION: High spatiotemporal resolution arterial phase imaging provides multiple angiographic and arterial phases in a single breath-hold, enabling accurate depiction of vascular anatomy while maintain optimal arterial phase imaging for characterization of focal lesions.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Angiografia , Suspensão da Respiração , Carcinoma Hepatocelular/patologia , Meios de Contraste/química , Artéria Hepática/patologia , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional/métodos , Fígado/patologia , Cirrose Hepática/fisiopatologia , Neoplasias Hepáticas/patologia , Imageamento por Ressonância Magnética , Padrões de Referência , Estudos Retrospectivos , Sensibilidade e Especificidade
20.
Clin Invest Med ; 38(3): E90-9, 2015 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-26026643

RESUMO

PURPOSE: To determine the reliability of arterial phase capture and evaluate hypervascular lesion contrast kinetics with a combined view-sharing and parallel imaging dynamic contrast-enhanced acquisition, DIfferential Sub-sampling with Cartesian Ordering (DISCO), in patients with known chronic liver disease. METHODS: A retrospective review of 3T MR images from 26 patients with known chronic liver disease referred for hepatocellular carcinoma surveillance or post-treatment follow up was performed. After administration of a gadolinium-based contrast agent, a multiphasic acquisition was obtained in a 28 s breath-hold, from which seven sequential post-contrast image volumes were reconstructed. RESULTS: The late arterial phase was successfully captured in all cases (26/26, 95% CI 87-100%). Images obtained 26 s post-injection had the highest frequency of late arterial phase capture (20/26) and lesion detection (23/26) of any individual post-contrast time; however, the multiphasic data resulted in a significantly higher frequency of late arterial phase capture (26/26, p=0.03) and a higher relative contrast (5.37+/-0.97 versus 7.10+/-0.98, p < 0.01). CONCLUSION: Multiphasic acquisition with combined view-sharing and parallel imaging reliably captures the late arterial phase and provides sufficient temporal resolution to characterize hepatic lesion contrast kinetics in patients with chronic liver disease while maintaining high spatial resolution.


Assuntos
Carcinoma Hepatocelular/diagnóstico , Imagem Ecoplanar/métodos , Neoplasias Hepáticas/diagnóstico , Fígado/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma Hepatocelular/patologia , Doença Crônica , Feminino , Humanos , Hepatopatias/diagnóstico , Hepatopatias/patologia , Neoplasias Hepáticas/patologia , Masculino , Pessoa de Meia-Idade , Triagem Multifásica/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA