1.
Adv Sci (Weinh) ; 10(30): e2303441, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37587776

RESUMO

Hyperpolarization techniques increase nuclear spin polarization by more than four orders of magnitude, enabling metabolic MRI. Even though hyperpolarization has shown clear value in clinical studies, the complexity, cost and slowness of current equipment limits its widespread use. Here, a polarization procedure of [1-13 C]pyruvate based on parahydrogen-induced polarization by side-arm hydrogenation (PHIP-SAH) in an automated polarizer is demonstrated. It is benchmarked in a study with 48 animals against a commercial dissolution dynamic nuclear polarization (d-DNP) device. Purified, concentrated (≈70-160 mM) and highly hyperpolarized (≈18%) solutions of pyruvate are obtained at physiological pH for volumes up to 2 mL within 85 s in an automated process. The safety profile, image quality, as well as the quantitative perfusion and lactate-to-pyruvate ratios, are equivalent for PHIP and d-DNP, rendering PHIP a viable alternative to established hyperpolarization techniques.


Assuntos
Hidrogênio , Ácido Pirúvico , Animais , Ácido Pirúvico/metabolismo , Isótopos de Carbono , Imageamento por Ressonância Magnética/métodos , Hidrogenação
2.
J Am Chem Soc ; 145(10): 5960-5969, 2023 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-36857421

RESUMO

We present a versatile method for the preparation of hyperpolarized [1-13C]fumarate as a contrast agent for preclinical in vivo MRI, using parahydrogen-induced polarization (PHIP). To benchmark this process, we compared a prototype PHIP polarizer to a state-of-the-art dissolution dynamic nuclear polarization (d-DNP) system. We found comparable polarization, volume, and concentration levels of the prepared solutions, while the preparation effort is significantly lower for the PHIP process, which can provide a preclinical dose every 10 min, opposed to around 90 min for d-DNP systems. With our approach, a 100 mM [1-13C]-fumarate solution of volumes up to 3 mL with 13-20% 13C-hyperpolarization after purification can be produced. The purified solution has a physiological pH, while the catalyst, the reaction side products, and the precursor material concentrations are reduced to nontoxic levels, as confirmed in a panel of cytotoxicity studies. The in vivo usage of the hyperpolarized fumarate as a perfusion agent in healthy mice and the metabolic conversion of fumarate to malate in tumor-bearing mice developing regions with necrotic cell death is demonstrated. Furthermore, we present a one-step synthesis to produce the 13C-labeled precursor for the hydrogenation reaction with high yield, starting from 13CO2 as a cost-effective source for 13C-labeled compounds.


Assuntos
Fumaratos , Imageamento por Ressonância Magnética , Camundongos , Animais , Espectroscopia de Ressonância Magnética , Imageamento por Ressonância Magnética/métodos , Hidrogenação , Meios de Contraste
3.
J Phys Chem Lett ; 14(8): 2125-2132, 2023 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-36802642

RESUMO

Magnetic resonance imaging of 13C-labeled metabolites enhanced by parahydrogen-induced polarization (PHIP) enables real-time monitoring of processes within the body. We introduce a robust, easily implementable technique for transferring parahydrogen-derived singlet order into 13C magnetization using adiabatic radio frequency sweeps at microtesla fields. We experimentally demonstrate the applicability of this technique to several molecules, including some molecules relevant for metabolic imaging, where we show significant improvements in the achievable polarization, in some cases reaching above 60% nuclear spin polarization. Furthermore, we introduce a site-selective deuteration scheme, where deuterium is included in the coupling network of a pyruvate ester to enhance the efficiency of the polarization transfer. These improvements are enabled by the fact that the transfer protocol avoids relaxation induced by strongly coupled quadrupolar nuclei.

4.
J Am Chem Soc ; 138(31): 9747-50, 2016 08 10.
Artigo em Inglês | MEDLINE | ID: mdl-27472048

RESUMO

We report a (129)Xe NMR relaxation-based sensing approach that exploits changes in the bulk xenon relaxation rate induced by slowed tumbling of a cryptophane-based sensor upon target binding. The amplification afforded by detection of the bulk dissolved xenon allows sensitive detection of targets. The sensor comprises a xenon-binding cryptophane cage, a target interaction element, and a metal chelating agent. Xenon associated with the target-bound cryptophane cage is rapidly relaxed and then detected after exchange with the bulk. Here we show that large macromolecular targets increase the rotational correlation time of xenon, increasing its relaxation rate. Upon binding of a biotin-containing sensor to avidin at 1.5 µM concentration, the free xenon T2 is reduced by a factor of 4.


Assuntos
Técnicas Biossensoriais , Substâncias Macromoleculares/química , Isótopos de Xenônio/química , Biotina/química , Quelantes/química , Espectroscopia de Ressonância Magnética , Metais/química , Peso Molecular , Peptídeos/química , Compostos Policíclicos , Ligação Proteica , Solubilidade , Água/química
5.
Biosens Bioelectron ; 24(11): 3252-7, 2009 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-19442510

RESUMO

Biopsies provide required information to diagnose cancer but, because of their invasiveness, they are difficult to use for managing cancer therapy. The ability to repeatedly sample the local environment for tumor biomarker, chemotherapeutic agent, and tumor metabolite concentrations could improve early detection of metastasis and personalized therapy. Here we describe an implantable diagnostic device that senses the local in vivo environment. This device, which could be left behind during biopsy, uses a semi-permeable membrane to contain nanoparticle magnetic relaxation switches. A cell line secreting a model cancer biomarker produced ectopic tumors in mice. The transverse relaxation time (T(2)) of devices in tumor-bearing mice was 20+/-10% lower than devices in control mice after 1 day by magnetic resonance imaging (p<0.01). Short term applications for this device are numerous, including verification of successful tumor resection. This may represent the first continuous monitoring device for soluble cancer biomarkers in vivo.


Assuntos
Biomarcadores Tumorais/análise , Técnicas Biossensoriais/instrumentação , Coriocarcinoma/imunologia , Coriocarcinoma/mortalidade , Imunoensaio/instrumentação , Magnetismo/instrumentação , Monitorização Ambulatorial/instrumentação , Próteses e Implantes , Animais , Biomarcadores Tumorais/imunologia , Linhagem Celular Tumoral , Coriocarcinoma/patologia , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Camundongos , Camundongos Nus , Sensibilidade e Especificidade
6.
Lab Chip ; 7(10): 1288-93, 2007 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17896012

RESUMO

By combining the sensing capabilities of nanoscale magnetic relaxation switches (MRS) within multi-reservoir structures, a potentially powerful implantable multiplexed sensor has been developed. MRS are magnetic nanoparticles that decrease the transverse relaxation time (T(2)) of water in the presence of an analyte. The switches encased in polydimethylsiloxane (PDMS) devices with polycarbonate membranes (10 nm pores) have demonstrated in vitro sensing of the beta subunit of human chorionic gonadotrophin (hCG-beta), which is elevated in testicular and ovarian cancer. Devices showed transverse relaxation time (T(2)) shortening by magnetic resonance imaging (MRI) when incubated in analyte solutions of 0.5 to 5 microg hCG-beta mL(-1). The decrease in T(2) was between 9% and 27% (compared to control devices) after approximately 28 h. This prototype device is an important first step in developing an implantable sensor for detecting soluble cancer biomarkers in vivo.


Assuntos
Biomarcadores Tumorais/sangue , Técnicas Biossensoriais/instrumentação , Análise Química do Sangue/instrumentação , Análise de Injeção de Fluxo/instrumentação , Magnetismo/instrumentação , Técnicas Analíticas Microfluídicas/instrumentação , Neoplasias/sangue , Técnicas Biossensoriais/métodos , Análise Química do Sangue/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Análise de Injeção de Fluxo/métodos , Humanos , Técnicas Analíticas Microfluídicas/métodos