Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Updates Surg ; 75(4): 855-862, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37093495

RESUMO

Management of diverticular abscess (DA) is still controversial. Antibiotic therapy is indicated in abscesses ≤ 4 cm, while percutaneous drainage/surgery in abscesses > 4 cm. The study aims to assess the role of antibiotics and surgical treatments in patients affected by DA. We retrospectively analyzed 100 consecutive patients with DA between 2013 and 2020, with a minimum follow-up of 12 months. They were divided into two groups depending on abscess size ≤ or > 4 cm (group 1 and group 2, respectively). All patients were initially treated with intravenous antibiotics. Surgery was considered in patients with generalized peritonitis at admission or after the failure of antibiotic therapy. The primary endpoint was to compare recurrence rates for antibiotics and surgery. The secondary endpoint was to assess the failure rate of each antibiotic regimen resulting in surgery. In group 1, 31 (72.1%) patients were conservatively treated and 12 (27.9%) underwent surgery. In group 2, percentages were respectively 50.9% (29 patients) and 49.1% (28 patients). We observed 4 recurrences in group 1 and 6 in group 2. Recurrence required surgery in 3 patients/group. We administered amoxicillin-clavulanic acid to 74 patients, piperacillin-tazobactam to 14 patients and ciprofloxacin + metronidazole to 12 patients. All patients referred to surgery had been previously treated with amoxicillin-Powered by Editorial Manager® and ProduXion Manager® from Aries Systems Corporation clavulanic acid. No percutaneous drainage was performed in a hundred consecutive patients. Surgical treatment was associated with a lower risk of recurrence in patients with abscess > 4 cm, compared to antibiotics. Amoxicillin-clavulanic acid was associated with a higher therapeutic failure rate than piperacillin-tazobactam/ciprofloxacin + metronidazole.


Assuntos
Abscesso Abdominal , Doença Diverticular do Colo , Diverticulose Cólica , Humanos , Abscesso/complicações , Abscesso/cirurgia , Doença Diverticular do Colo/complicações , Abscesso Abdominal/tratamento farmacológico , Abscesso Abdominal/etiologia , Abscesso Abdominal/cirurgia , Estudos Retrospectivos , Metronidazol , Combinação Amoxicilina e Clavulanato de Potássio , Colectomia/métodos , Diverticulose Cólica/cirurgia , Antibacterianos/uso terapêutico , Drenagem/métodos , Ciprofloxacina/uso terapêutico , Combinação Piperacilina e Tazobactam
2.
Int J Cardiovasc Imaging ; 36(10): 2007-2015, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32472299

RESUMO

To evaluate the accuracy of 3D models of the aortic-root generated from non-contrast cardiac magnetic resonance (CMR). Data were retrospectively collected from 30 consecutive patients who underwent surgical aortic valve replacement and had available records of both intra-operative assessment and pre-surgery annulus assessment by cardiovascular computed tomography (CCT) and CMR. The 3D models were independently segmented, modelled and printed by two blinded "manufacturers". The measurements on the models were carried out by two cardiac surgeons with Hegar dilator. Data were analyzed with non-parametric tests. There was no significant intra- or inter-observer variability (p ≥ 0.13). The agreement between the diameter of the 3D model derived from CMR images and either the anatomical reference of the intraoperative measurement (p = 0.10, r = 0.97) or the radiological reference of the 3D model generated from CCT (p = 0.71, r = 0.92) was very good. The process of segmentation plus the post-processing was about 17 ± 2 min for a model created by CMR, significantly higher than a model created from CCT (7 ± 2 min; p < 0.001). The printing time for a single model did not differ between the two modalities (p = 0.61) and was less than 60 min. The cost for a single model was approximately 0.5 €. 3D models generated from non-contrast CMR performed well when compared to the anatomical reference standard and are comparable to the pair CCT derived models.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Imageamento por Ressonância Magnética , Modelos Cardiovasculares , Tomografia Computadorizada Multidetectores , Impressão Tridimensional , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Tempo , Substituição da Valva Aórtica Transcateter , Fluxo de Trabalho
3.
J Cardiovasc Comput Tomogr ; 12(5): 391-397, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29857953

RESUMO

BACKGROUND: to determine reliability and reproducibility of measurements of aortic annulus in 3D models printed from cardiovascular computed tomography (CCT) images. METHODS: Retrospective study on the records of 20 patients who underwent aortic valve replacement (AVR) with pre-surgery annulus assessment by CCT and intra-operative sizing by Hegar dilators (IOS). 3D models were fabricated by fused deposition modelling of thermoplastic polyurethane filaments. For each patient, two 3D models were independently segmented, modelled and printed by two blinded "manufacturers": a radiologist and a radiology technician. Two blinded cardiac surgeons performed the annulus diameter measurements by Hegar dilators on the two sets of models. Matched data from different measurements were analyzed with Wilcoxon test, Bland-Altmann plot and within-subject ANOVA. RESULTS: No significant differences were found among the measurements made by each cardiac surgeon on the same 3D model (p = 0.48) or on the 3D models printed by different manufacturers (p = 0.25); also, no intraobserver variability (p = 0.46). The annulus diameter measured on 3D models showed good agreement with the reference CCT measurement (p = 0.68) and IOH sizing (p = 0.11). Time and cost per model were: model creation ∼10-15 min; printing time ∼60 min; post-processing ∼5min; material cost ∼1€. CONCLUSION: 3D printing of aortic annulus can offer reliable, not expensive patient-specific information to be used in the pre-operative planning of AVR or transcatheter aortic valve implantation (TAVI).


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Próteses Valvulares Cardíacas , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Impressão Tridimensional , Tomografia Computadorizada por Raios X , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Dados Preliminares , Desenho de Prótese , Estudos Retrospectivos
4.
Radiother Oncol ; 127(3): 481-486, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29729845

RESUMO

BACKGROUND AND PURPOSE: Inadvertent heart and coronary arteries (CA) irradiation may increase the risk of coronary artery disease (CAD) in patients receiving thoracic irradiation. To date, the entity of cardiac-related CA displacement and the possible margins to be used for planning organs at risk volume (PRV) have been poorly described. Aim of this study was to quantify CA displacement and to estimate PRV through the use of ECG-gated computed tomography (CT) scans. MATERIAL AND METHODS: Eight patients received an ECG-gated intravenous contrast enhanced CT for non-cancer related reasons. Nine data sets were reconstructed over the entire R-R cycle with a dedicated retrospective algorithm and the following structures were delineated: Left main trunk (LM), left anterior descending (LAD), left circumflex (CX) and right coronary artery (RCA). CA displacements across the different cardiac phases were evaluated in left-right (X), cranio-caudal (Y) and anteroposterior (Z) directions using the McKenzie-van Herk formula (1.3 * Σ + 0.5 * σ). RESULTS: The following CA displacements were found in X, Y and Z coordinates: 3.6, 2.7 and 2.7 mm for LMT, respectively; 2.6, 5.0 and 6.8 mm for LAD, respectively; 3.5, 4.5 and 3.7 mm for CX, respectively; 3.6, 4.6 and 6.9 mm for RCA, respectively. Based on the mean displacements, we created a PRV of 3 mm for LM, 4 mm for CX and 5 mm for LAD and RCA. CONCLUSION: CA showed relevant displacements over the heart cycle, suggesting the need for a specific PRV margin to accurately estimate the dose received by these structures and optimize the planning process.


Assuntos
Vasos Coronários/diagnóstico por imagem , Eletrocardiografia/métodos , Coração/diagnóstico por imagem , Neoplasias do Mediastino/diagnóstico por imagem , Neoplasias do Mediastino/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Algoritmos , Doença da Artéria Coronariana , Vasos Coronários/anatomia & histologia , Vasos Coronários/efeitos da radiação , Coração/anatomia & histologia , Coração/efeitos da radiação , Humanos , Mediastino/anatomia & histologia , Mediastino/diagnóstico por imagem , Mediastino/efeitos da radiação , Movimento (Física) , Órgãos em Risco/diagnóstico por imagem , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
5.
Int J Cardiovasc Imaging ; 32(8): 1255-63, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27117264

RESUMO

To assess the accuracy and reproducibly of cardiovascular magnetic resonance (CMR) in the measurement of the aortic annulus and in process of valve sizing as compared to intra-operative sizing, cardiovascular computed tomography (CCT) and transesophageal echocardiography (TEE). Retrospective study on 42 patients who underwent aortic valve replacement from September 2010 to September 2015, with available records of pre surgery annulus assessment by CMR, CCT and TEE and of peri-operative assessment. In CCT and CMR, the annular plane was considered a virtual ring formed by the lowest hinge points of the valvular attachments to the aorta. In TEE the annulus was measured at the base of leaflet insertion in the mid-esophageal long-axis view using the X-plane technique. Two double-blinded operators performed the assessments for each imaging technique. Intra-operative evaluation was performed using Hegar dilators. Continuous variables were studied with within-subject ANOVA, Bland-Altman (BA) plots, Wilcoxon's and Friedman's tests; trends were explored with scatter plots. Categorical variables were studied with Fisher's exact test. The intra- and inter-operator reliability was satisfying. There were no significant differences between the annulus dimensions measured by CMR and either one of the three references. Valve sizing for CoreValve by CMR had the same good agreement with CCT and TEE, with a 78 % match rate; for SAPIEN XT the agreement was slightly better (82 %) for CCT than for TEE (66 %). MR performs well when compared to the surgical reference of intra-operative sizing and stands up to the level of the most used imaging references (CCT and TEE).


Assuntos
Valva Aórtica/diagnóstico por imagem , Ecocardiografia Transesofagiana , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X , Idoso , Idoso de 80 Anos ou mais , Pontos de Referência Anatômicos , Valva Aórtica/cirurgia , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Humanos , Cuidados Intraoperatórios , Masculino , Variações Dependentes do Observador , Valor Preditivo dos Testes , Desenho de Prótese , Reprodutibilidade dos Testes , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA