Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Clin Med ; 10(23)2021 Nov 26.
Artigo em Inglês | MEDLINE | ID: mdl-34884268

RESUMO

This is a consensus document of the Spanish Society of Cardiovascular Infections (SEICAV), the Spanish Society of Thoracic and Cardiovascular Surgery (SECTCV) and the Biomedical Research Centre Network for Respiratory Diseases (CIBERES). These three entities have brought together a multidisciplinary group of experts that includes anaesthesiologists, cardiac and cardiothoracic surgeons, clinical microbiologists, infectious diseases and intensive care specialists, internal medicine doctors and radiologists. Despite the clinical and economic consequences of sternal wound infections, to date, there are no specific guidelines for the prevention, diagnosis and management of mediastinitis based on a multidisciplinary consensus. The purpose of the present document is to provide evidence-based guidance on the most effective diagnosis and management of patients who have experienced or are at risk of developing a post-surgical mediastinitis infection in order to optimise patient outcomes and the process of care. The intended users of the document are health care providers who help patients make decisions regarding their treatment, aiming to optimise the benefits and minimise any harm as well as the workload.

2.
Interact Cardiovasc Thorac Surg ; 32(4): 499-505, 2021 04 19.
Artigo em Inglês | MEDLINE | ID: mdl-33881147

RESUMO

OBJECTIVES: Durability of sutureless aortic bioprosthetic valves remains a major issue. The aim of this study was to assess structural valve deterioration (SVD) and bioprosthetic valve failure (BVF) of the Perceval bioprosthesis using the new proposed standardized definitions. METHODS: All patients who underwent aortic valve replacement with sutureless Perceval S prostheses up to September 2016 were included. Clinical and echocardiographic follow-up was performed. New standardized definitions were used to assess the durability of sutureless bioprosthetic valves. From 2013 to 2016, 214 patients were included. RESULTS: The mean age and EuroSCORE II were 79 years and 2.74. Thirty-day mortality was 0.47%. The survival rate was 96.8%, 88.1% and 85.7% at 1, 3 and 4 years, respectively. The median echocardiographic follow-up was 3.28 years. The mean pressure gradient was 11.3 mmHg. No cases showed evidence of severe SVD, 17 patients had moderate SVD with a mean pressure gradient of 24 mmHg and 8 patients had definite late BVF. The incidence of moderate SVD and BVF at 4 years was 8.8% and 2.9%, respectively. CONCLUSIONS: Mid-term follow-up to 6.3 years after aortic valve replacement with the Perceval bioprosthesis documents favourable haemodynamic and clinical outcomes and low rates of SVD and BVF.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Bioprótese , Consenso , Humanos , Desenho de Prótese , Resultado do Tratamento
3.
J Thorac Dis ; 11(7): 2945-2954, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31463124

RESUMO

BACKGROUND: The main objective was to analyse the impact of the modification of the Perceval S implantation technique on the prevalence of postoperative atrioventricular block, which requires a permanent pacemaker, in our aortic valve replacement series. In addition, we attempted to identify those risk factors that are related to the appearance of this complication. METHODS: Five hundred and seventy-two valve replacements were carried out with PERCEVAL S in our centre up to July 2018. Use of modified technique (n=302). Minimally invasive approach (n=340). Associated coronary surgery (n=95). Patients with pacemakers prior to surgery (n=27) and associated mitral or tricuspid valve surgery (n=26) were excluded. We analysed variables of interest that could influence the increase in postoperative atrioventricular block. Technique performed, disorders of intraventricular conduction and pre/intraoperative characteristics. The influence of the modified technique was analysed. RESULTS: Five hundred and nineteen aortic valve replacements with PERCEVAL S. Age (years) (median 77, interquartile range 8). Height (cm) (159, 13.5). Euroscore II (%) (2.25, 2.27). Postoperative atrioventricular block standard technique (n=23, 10.14%). Modified technique (n=14, 4.30%) (P=0.009). Multivariate regression analysis. Final model AUC =0.740, maximum model AUC =0.774 (P>0.05). Includes: Technique used (P=0.024), height (P=0.043) and disorders of interventricular conduction, right bundle branch block (P=0.005), trifascicular block (P=0.008). CONCLUSIONS: In our experience, the modified technique significantly decreases the incidence of postoperative atrioventricular block that requires a permanent pacemaker in the aortic valve replacement with PERCEVAL S. The prior electrocardiographic presence of right bundle branch block, trifascicular block and the height of the patient are associated with an increased risk of blocking.

4.
Eur J Cardiothorac Surg ; 49(6): 1732-3, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26503726

RESUMO

We present a case of spontaneous fracture and embolization of the distal part of a cannula into the left inferior lobar artery. The embolized fragment was captured with an angioplasty balloon and extracted through the right atrium appendage. No adverse event related to the embolization was observed and the patient was discharged with no sequelae.


Assuntos
Cânula , Ponte Cardiopulmonar/instrumentação , Embolia/etiologia , Migração de Corpo Estranho/etiologia , Veia Cava Inferior , Idoso , Angioplastia com Balão/métodos , Ponte Cardiopulmonar/efeitos adversos , Embolia/diagnóstico por imagem , Embolia/cirurgia , Falha de Equipamento , Migração de Corpo Estranho/diagnóstico por imagem , Migração de Corpo Estranho/cirurgia , Implante de Prótese de Valva Cardíaca , Humanos , Rim/irrigação sanguínea , Masculino , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA