Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Interact Cardiovasc Thorac Surg ; 33(2): 195-202, 2021 07 26.
Artigo em Inglês | MEDLINE | ID: mdl-33792711

RESUMO

OBJECTIVES: This study aims to evaluate the efficacy, safety and long-term outcomes of a renoprotective non-contrast, transoesophageal echocardiography-guided transapical (TA) transcatheter aortic valve replacement (TAVR) strategy with a balloon-expandable prosthesis, as well as to determine its impact on renal function. METHODS: Between 2009 and 2019, 200 consecutive patients underwent a non-contrast, transoesophageal echocardiography-guided TA TAVR with a balloon-expandable prosthesis. RESULTS: The device success rate was 95.5%. Transoesophageal echocardiography-guided deployment demonstrated a low rate of procedure-related complications: 9.5% of acute kidney injury, 8% postoperative bleeding, 6% low-cardiac output, 4.5% postprocedural aortic regurgitation ≥+2, 4% implantation of permanent pacemaker and 2% stroke. There were no significant differences between preoperative and on discharge estimated glomerular filtration rate (53.9 ± 22.2 vs 54.3 ± 22.9 ml/min/1.73 m2, P = 0.60). Logistic regression analysis confirmed postoperative bleeding as an independent predictor for acute kidney injury (odds ratio (OR) 11.148, 95% confidence interval 3.537-35.140, P < 0.001). In-hospital mortality was 7.5%. The mean follow-up was 48.5 ± 39.9 months. Renal function and patient's chronic kidney disease stage did not significantly vary during follow-up. Long-term cumulative survival at 1, 5 and 10 years was 84.2 ± 0.027%, 42.9 ± 0.038% and 32.5 ± 0.044%, respectively. Renal function affected on neither in-hospital mortality nor long-term survival. CONCLUSIONS: Non-contrast, transoesophageal echocardiography-guided TA TAVR is a safe and reproducible technique with a low incidence of periprocedural complications that avoids the use of contrast and mitigates the incidence of acute kidney injury.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
3.
J Card Surg ; 31(5): 264-73, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26991888

RESUMO

BACKGROUND: This study aims to determine the incidence and causes of structural valve deterioration (SVD) among all models of Mitroflow bioprostheses (A12/LX/DL), as well as to define their long-term clinical and hemodynamic performance. METHODS AND RESULTS: We retrospectively reviewed a series of 1023 patients who underwent aortic valve replacement with Mitroflow bioprostheses between 2001 and 2014. A small aortic root was found in 22.4% of patients. There were two cases of severe patient-prosthesis mismatch. Only 31 patients developed SVD. The rate of incidence was 8.1 cases per 1000 patient-years. Cumulative incidence of SVD was 1.4% and 3% at five and 10 years, respectively. Freedom from SVD was 97.4% and 88.2% at five and 10 years, respectively. Anticalcification phospholipid reduction treatment (PRT) for model DL was a protective factor for SVD. Multivariable analysis confirmed age <70 years and use of 19 mm valve as independent predictors of SVD. Cumulative survival was 76.6% at five years and 42.3% at 10 years (mean follow-up 3.8 ± 3.1 years). In multivariable analysis, neither the use of small aortic prosthesis (p = 0.18) nor the occurrence of SVD (p = 0.85) was found to be independent predictors of long-term survival. CONCLUSIONS: Mitroflow valves demonstrate an acceptable rate of SVD and satisfactory long-term hemodynamic performance, particularly in patients with small aortic roots, age >70 years, and cases with severe left ventricular hypertrophy. PRT might contribute to improved long-term durability. doi: 10.1111/jocs.12726 (J Card Surg 2016;31:264-273).


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese , Próteses Valvulares Cardíacas , Hemodinâmica , Teste de Materiais , Complicações Pós-Operatórias/epidemiologia , Idoso , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/fisiopatologia , Ecocardiografia , Feminino , Seguimentos , Humanos , Masculino , Desenho de Prótese , Estudos Retrospectivos , Espanha/epidemiologia , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA