Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
1.
Annu Int Conf IEEE Eng Med Biol Soc ; 2018: 4150-4153, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30441269

RESUMO

In most conventional radiation therapy treatments, special attention is payed for neutron contamination when working with energy beams above 8 MeV and generally it is only considered for shielding requirements, not for dose study in patients or employees. The present work is focused on studying the unwanted generated photoneutrons in a Medical Linear Accelerator (LinAc) Varian TrueBeam using a 6 MeV radiation treatment beam. To that, Monte Carlo (MC) simulation code MCNP6.1.1 was used. This version of the code allows the use of unstructured mesh geometries as a novelty, offering more reliable results and higher speed computation. The particularity of the studied LinAc is the presence of a beryllium filter at the treatment head. Since Beryllium causes photonuclear reactions (γ, n) at energies much lower than other LinAc composing materials, this work aims to analyze if this type of units, when using low energy treatment beams (6 MeV), produce neutron pollution and to ensure that this unwanted radiation can be considered negligible.


Assuntos
Berílio , Aceleradores de Partículas , Método de Monte Carlo , Fótons
2.
Annu Int Conf IEEE Eng Med Biol Soc ; 2018: 6149-6152, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30441738

RESUMO

Radiation Therapy Planning Systems (RTPS) currently used in hospitals contain algorithms based on deterministic simplifications that do not properly consider electrons lateral transport in the areas where there are changes of density, and as a result, erroneous dose predictions could be produced. According to this, the present work proposes the use of Monte Carlo method in brachytherapy planning systems, which could affect positively on the radiotherapy treatment planning, since it provides results that are more accurate and takes into account the in homogeneities density variations. This paper presents a Monte Carlo (MC) simulation of a brachytherapy prostate treatment with I-125 seeds, using the latest version of MCNP, v.6.1.1. To that, a 3D model of the anatomy of a real anonymized patient is created from the segmentation of Computed Tomography (CT) images. Treatment over this 3D model is simulated and the dose given to each organ is obtained. These doses are compared with those calculated by deterministic planning system used in hospital demonstrating the effectiveness of MC method in the planning of brachytherapy treatments, because of not only the results precision but also regarding the affordable computing times.


Assuntos
Braquiterapia , Algoritmos , Humanos , Radioisótopos do Iodo , Masculino , Método de Monte Carlo , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
3.
Radiat Prot Dosimetry ; 164(4): 497-501, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25971342

RESUMO

(222)Rn is a naturally occurring gas created from the decay of (226)Ra. The long-term health risk of breathing radon is lung cancer. One particular place where indoor radon concentrations can exceed national guidelines is in wastewater treatment plants (WWTPs) where treatment processes may contribute to ambient airborne concentrations. The aim of this paper was to study the radon concentration decrease after the application of corrective measures in a Spanish WWTP. According to first measures, air radon concentration exceeded International Commission Radiologica1 Protection (ICRP) normative (recommends intervention between 400 and 1000 Bq m(-3)). Therefore, the WWTP improved mechanical forced ventilation to lower occupational exposure. This measure allowed to increase the administrative controls, since the limitation of workers access to the plant changed from 2 h d(-1) (considering a maximum permissible dose of 20 mSv y(-1) averaged over 5 y) to 7 h d(-1).


Assuntos
Poluentes Radioativos do Ar/análise , Poluição do Ar em Ambientes Fechados/análise , Radônio/análise , Instalações de Eliminação de Resíduos , Águas Residuárias/química , Poluentes Radioativos da Água/análise , Arquitetura de Instituições de Saúde , Gases , Humanos , Concentração Máxima Permitida , Exposição Ocupacional , Transição de Fase , Exposição à Radiação , Espanha , Ventilação , Purificação da Água
4.
Artigo em Inglês | MEDLINE | ID: mdl-26737878

RESUMO

Induced radioactivity and photoneutron contamination inside a radiation therapy bunker of a medical linear accelerator (Linac) is investigated in this work. The Linac studied is an Elekta Precise electron accelerator which maximum treatment photon energy is 15 MeV. This energy exceeds the photonuclear reaction threshold (around 7 MeV for high atomic number metals). The Monte Carlo code MCNP6 has been used for quantifying the neutron contamination inside the treatment room for different gantry rotation configuration. Walls activation processes have also been simulated. The approach described in this paper is useful to prevent the overexposure of patients and medical staff.


Assuntos
Nêutrons , Aceleradores de Partículas , Relação Dose-Resposta à Radiação , Humanos , Modelos Teóricos , Método de Monte Carlo
5.
Artigo em Inglês | MEDLINE | ID: mdl-24110018

RESUMO

Numerous improved physics-based methods for Linac photon spectra reconstruction have been published; some of them are based on transmission data analysis and others on scattering data. In this work, the two spectrum unfolding approaches are compared in order to experimentally validate its robustness and to determine which is the optimal methodology for application on a clinical quality assurance routine. Both studied methods are based on EPID images generated when the incident photon beam impinges onto plastic blocks. The distribution of transmitted/scatter radiation produced by this object centered at the beam field size was measured. Measurements were performed using a 6 MeV photon beam produced by the linear accelerator. The same radiation distribution conditions were also simulated with Monte Carlo code for a series of monoenergetic identical geometry photon beams for both cases. Two systems of linear equations were generated to combine the polyenergetic EPID measurements with the monoenergetic simulation results. Regularization techniques were applied to solve the systems for obtaining the incident photon spectrum. We present a comparison between the well-known photon Spectral Reconstruction based on Transmission Data (Trans-based) technology and the Spectral Reconstruction based on Scattering Data (Scatt-based), which we both developed using EPID images. It is shown that Trans-based reconstruction results display much better agreement with photon spectrum theoretical predictions.


Assuntos
Radioterapia de Intensidade Modulada , Algoritmos , Processamento de Imagem Assistida por Computador , Método de Monte Carlo , Aceleradores de Partículas , Fótons , Espalhamento de Radiação , Silício/química
6.
Appl Radiat Isot ; 70(7): 1267-71, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22698818

RESUMO

A calculation of the correct dose in radiation therapy requires an accurate description of the radiation source because uncertainties in characterization of the linac photon spectrum are propagated through the dose calculations. Unfortunately, detailed knowledge of the initial electron beam parameters is not readily available, and many researchers adjust the initial electron fluence values by trial-and-error methods. The main goal of this work was to develop a methodology to characterize the fluence of initial electrons before they hit the tungsten target of an Elekta Precise medical linear accelerator. To this end, we used a Monte Carlo technique to analyze the influence of the characteristics of the initial electron beam on the distribution of absorbed dose from a 6 MV linac photon beam in a water phantom. The technique is based on calculations with Software for Uncertainty and Sensitivity Analysis (SUSA) and Monte Carlo simulations with the MCNP5 transport code. The free parameters used in the SUSA calculations were the mean energy and full-width-at-half-maximum (FWHM) of the initial electron distribution. A total of 93 combinations of these parameters gave initial electron fluence configurations. The electron spectra thus obtained were used in a simulation of the electron transport through the target of the linear accelerator, which produced different photon (Bremsstrahlung) spectra. The simulated photon spectra were compared with the 6-MV photon spectrum provided by the linac manufacturer (Elekta). This comparison revealed how the mean energy and FWHM of the initial electron fluence affect the spectrum of the generated photons. This study has made it possible to fine-tune the examined electron beam parameters to obtain the resulted absorbed doses with acceptable accuracy (error<1%).

7.
Artigo em Inglês | MEDLINE | ID: mdl-23367244

RESUMO

The present work is focused on a MCNP Monte Carlo (MC) simulation of a multi-leaf collimator (MLC) radiation therapy treatment unit including its corresponding Electronic Portal Imaging Device (EPID). We have developed a methodology to perform a spatial calibration of the EPID signal to obtain dose distribution using MC simulations. This calibration is based on several images acquisition and simulation considering different thicknesses of solid water slabs, using a 6 MeV photon beam and a square field size of 20 cm x 20 cm. The resulting relationship between the EPID response and the MC simulated dose is markedly linear. This signal to dose EPID calibration was used as a dosimetric tool to perform the validation of the MLC linear accelerator MCNP model. Simulation results and measurements agreed within 2% of dose difference. The methodology described in this paper potentially offers an optimal verification of dose received by patients under complex multi-field conformal or intensity-modulated radiation therapy (IMRT).


Assuntos
Método de Monte Carlo , Dosagem Radioterapêutica , Calibragem , Humanos
8.
Artigo em Inglês | MEDLINE | ID: mdl-20981159

RESUMO

Radioprotection with natural products may be relevant to the mitigation of ionizing radiation-induced damage in mammalian systems; in this sense, propolis extracts have shown effects such as antioxidant, antitumoral, anti-inflammatory, and immunostimulant. We report for the first time a cytogenetic study to evaluate the radioprotective effect, in vitro, of propolis against radiation-induced chromosomal damage. Lymphocytes were cultured with increasing concentrations of ethanol extract of propolis (EEP), including 20, 40, 120, 250, 500, 750, 1000, and 2000 µg mL(-1) and then exposed to 2 Gy γ-rays. A significant and concentration-dependent decrease is observed in the frequency of chromosome aberrations in samples treated with EEP. The protection against the formation of dicentrics was concentration-dependent, with a maximum protection at 120 µg mL(-1) of EEP. The observed frequency of dicentrics is described as negative exponential function, indicating that the maximum protectible fraction of dicentrics is approximately 44%. Free radical scavenging and antioxidant activities are the mechanisms that these substances use to protect cells from ionizing radiation.

9.
Artigo em Inglês | MEDLINE | ID: mdl-22254262

RESUMO

Interventional radiologists and staff members are frequently exposed to the effects of direct and scattered radiation, which undergo in deterministic effects (radiodermitis, aged skin, cataracts, telangiectasia in nasal region, vasocellular epitelioms, hands depilation) and/or stochastic ones (cancer incidence). A methodology has been proposed for estimating the radiation risk or detriment from a group of six exposed interventional radiologists of the Hospital Universitario La Fe (Valencia, Spain), which had developed general exposition symptoms attributable to deterministic effects of ionizing radiation. Equivalent doses have been periodically registered using termoluminiscence dosimeters (TLD's) and wrist dosimeters, H(p)(10) and H(p)(0.07), respectively, and estimated through the observation of translocations in lymphocytes of peripheral blood (biological methods), by extrapolating the yield of translocations to their respective dose-effect curves. The software RADRISK has been applied for estimating radiation risks in these occupational radiation exposures. The minimum and maximum average excess ratio for skin cancer has been, using wrist physical doses, of [1.03 × 10(-3), 5.06 × 10(-2)], concluding that there is not an increased risk of skin cancer incidence. The minimum and maximum average excess ratio for leukemia has been, using TLD physical doses, of [7.84 × 10(-2), 3.36 × 10(-1)], and using biological doses, of [1.40 × 10(-1), 1.51], which is considerably higher than incidence rates, showing an excess radio-induced risk of leukemia in the group under study. Finally, the maximum radiological detriment in the group, evaluated as the total number of radio-induced cancers using physical dosimetry, has been of 2.18 per 1000 person-year (skin and leukemia), and using biological dosimetry of 9.20 per 1000 PY (leukemia). As a conclusion, this study has provided an assessment of the non-deterministic effects (rate of radio-induced cancer incidence) attributable to the group under study due to their professional activity.


Assuntos
Neoplasias Induzidas por Radiação/mortalidade , Exposição Ocupacional/estatística & dados numéricos , Modelos de Riscos Proporcionais , Doses de Radiação , Radiografia Intervencionista/estatística & dados numéricos , Radiometria/estatística & dados numéricos , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Medição de Risco , Fatores de Risco , Espanha/epidemiologia , Análise de Sobrevida , Taxa de Sobrevida , Adulto Jovem
10.
Artigo em Inglês | MEDLINE | ID: mdl-22254267

RESUMO

An accurate knowledge of the spectral distribution emission is essential for precise dose calculations in radiotherapy treatment planning. Reconstruction of photon spectra emitted by medical accelerators from measured depth dose distributions in a water cube is an important tool for commissioning a Monte Carlo treatment planning system. However, the reconstruction problem is an inverse radiation transport function which is poorly conditioned and its solution may become unstable due to small perturbations in the input data. In this paper we present a more stable spectral reconstruction method which can be used to provide an independent confirmation of source models for a given machine without any prior knowledge of the spectral distribution. This technique involves measuring the depth dose curve in a water phantom and applying an unfolding method using Monte Carlo simulated depth dose gradient curves for consecutives mono-energetic beams. We illustrate this theory to calculate a 6 and a 15 MeV photon beam emitted from an Elekta Precise radiotherapy unit using the gradient of depth dose curves in a cube-shaped water tank.


Assuntos
Algoritmos , Modelos Biológicos , Modelos Estatísticos , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Simulação por Computador , Relação Dose-Resposta à Radiação , Dosagem Radioterapêutica
11.
Artigo em Inglês | MEDLINE | ID: mdl-21095887

RESUMO

Megavoltage photon sources are normally used for radiotherapy treatments. For these equipments an accurate knowledge of their spectral distribution is essential for accurate dose calculations planning. There are several ways to determine the spectrum of a clinical photon beam: direct measurement, electron source modelling or reconstruction from experimental measures. In this paper we focus on the latter type of spectral reconstruction methods which can be used to provide an independent confirmation of source models for a given machine without any prior knowledge of the spectral distribution. This technique involves measuring the depth dose curve in a water phantom and applying an unfolding method using Monte Carlo simulated depth dose curves for consecutives mono-energetic beams. We illustrate this theory to calculate a 6 MeV photon beam from an Elekta Precise radiotherapy unit using the gradient of depth dose measurements in a cube-shaped water tank.


Assuntos
Modelos Teóricos , Aceleradores de Partículas/instrumentação , Doses de Radiação , Simulação por Computador , Desenho Assistido por Computador , Elétrons , Desenho de Equipamento , Análise de Falha de Equipamento , Fótons , Espalhamento de Radiação
12.
Appl Radiat Isot ; 68(4-5): 913-7, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-19963391

RESUMO

Commercial planning systems used in radiotherapy treatments use determinist correlations to evaluate dose distribution around regions of interest. Estimated dose with this type of planners can be problematic, especially when analyzing heterogeneous zones. The present work is focused in quantifying the dose distribution in a heterogeneous medium irradiated by a 6 MeV photon beam emitted by an Elekta Precise Radiotherapy Unit head. Dose mapping inside the heterogeneous water phantom has been simulated with the photon and electron transport with Monte Carlo computer code MCNP5 and also, using a commercial treatment planning software in the same irradiation conditions. The calculated results were compared with experimental relative dose curves. This comparison shows that inside the heterogeneity region, the commercial algorithms are not able to predict the variation of dose in the heterogeneous zones with the same precision as MCNP5.


Assuntos
Algoritmos , Modelos Biológicos , Método de Monte Carlo , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Software , Simulação por Computador , Dosagem Radioterapêutica
13.
Appl Radiat Isot ; 68(4-5): 709-13, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-19892556

RESUMO

The aim of this work is to provide the reconstruction of a real human voxelized phantom by means of a MatLab program and the simulation of the irradiation of such phantom with the photon beam generated in a Theratron 780 (MDS Nordion) (60)Co radiotherapy unit, by using the Monte Carlo transport code MCNP (Monte Carlo N-Particle), version 5. The project results in 3D dose mapping calculations inside the voxelized antropomorphic head phantom. The program provides the voxelization by first processing the CT slices; the process follows a two-dimensional pixel and material identification algorithm on each slice and three-dimensional interpolation in order to describe the phantom geometry via small cubic cells, resulting in an MCNP input deck format output. Dose rates are calculated by using the MCNP5 tool FMESH, superimposed mesh tally, which gives the track length estimation of the particle flux in units of particles/cm(2). Furthermore, the particle flux is converted into dose by using the conversion coefficients extracted from the NIST Physical Reference Data. The voxelization using a three-dimensional interpolation technique in combination with the use of the FMESH tool of the MCNP Monte Carlo code offers an optimal simulation which results in 3D dose mapping calculations inside anthropomorphic phantoms. This tool is very useful in radiation treatment assessments, in which voxelized phantoms are widely utilized.


Assuntos
Algoritmos , Carga Corporal (Radioterapia) , Modelos Biológicos , Método de Monte Carlo , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Simulação por Computador , Humanos
14.
Eur J Radiol ; 75(2): 259-64, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19380209

RESUMO

Interventional radiologists and staff members are frequently exposed to protracted and fractionated low doses of ionizing radiation, which extend during all their professional activities. These exposures can derive, due to the effects of direct and scattered radiation, in deterministic effects (radiodermitis, aged skin, cataracts, telangiectasia in nasal region, vasocellular epitelioms, hands depilation) and/or stochastic ones (cancer incidence). A methodology has been proposed for estimating the radiation risk or detriment from a group of six exposed interventional radiologists of the Hospital Universitario La Fe (Valencia, Spain), which had developed general exposition symptoms attributable to deterministic effects of ionizing radiation. Equivalent doses have been periodically registered using TLD's and wrist dosimeters, H(p)(10) and H(p)(0.07), respectively, and estimated through the observation of translocations in lymphocytes of peripheral blood (biological methods), by extrapolating the yield of translocations to their respective dose-effect curves. The software RADRISK has been applied for estimating radiation risks in these occupational radiation exposures. This software is based on transport models from epidemiological studies of population exposed to external sources of ionizing radiation, such as Hiroshima and Nagasaki atomic bomb survivors [UNSCEAR, Sources and effects of ionizing radiation: 2006 report to the general assembly, with scientific annexes. New York: United Nations; 2006]. The minimum and maximum average excess ratio for skin cancer has been, using wrist physical doses, of [1.03x10(-3), 5.06x10(-2)], concluding that there is not an increased risk of skin cancer incidence. The minimum and maximum average excess ratio for leukemia has been, using TLD physical doses, of [7.84x10(-2), 3.36x10(-1)], and using biological doses, of [1.40x10(-1), 1.51], which is considerably higher than incidence rates, showing an excess radio-induced risk of leukemia in the group under study. Finally, the maximum radiological detriment in the group, evaluated as the total number of radio-induced cancers using physical dosimetry, has been of 2.18/1000 person-year (skin and leukemia), and using biological dosimetry of 9.20/1000 PY (leukemia). As a conclusion, this study has provided an assessment of the non-deterministic effects (rate of radio-induced cancer incidence) attributable to the group under study due to their professional activity.


Assuntos
Neoplasias Induzidas por Radiação/etiologia , Doenças Profissionais/etiologia , Monitoramento de Radiação , Radiologia Intervencionista , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Exposição Ocupacional , Doses de Radiação , Monitoramento de Radiação/instrumentação , Medição de Risco
15.
Artigo em Inglês | MEDLINE | ID: mdl-19963982

RESUMO

The Valencian Breast Cancer Early Detection Program (VBCEDP) started in the Valencian Community (Spain) in 1992. Up to now, 24 mammographic units have been installed all over the region. Mammography is used to aid in the diagnosis of breast cancer diseases in women. There is a health risk in the studied women due to ionising radiation that has to be estimated and controlled. A methodology to calculate approximately the radiological detriment in the VBCEDP has been developed based on Monte Carlo techniques. It has been used, as qualitative parameter, the average mean glandular dose from representative sample populations undergoing screening mammography (digital or screenfilm) from each of the twenty-four units in operation. The American College of Radiology Imaging Network reached to conclusion that digital mammography performed significantly better than film for pre and perimenopausal women younger than 50. Women who are undergoing the program are between 45 and 69. This fact allows us to study premenopausic women. Our group uses the software SCREENRISK to estimate induction and mortality rates in order to corroborate American conclusions in an European region. The obtained results confirm the American results about the application of digital mammography in pre and perimenopausal women younger than 50 years.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/mortalidade , Mamografia/mortalidade , Programas de Rastreamento/mortalidade , Pós-Menopausa , Modelos de Riscos Proporcionais , Lesões por Radiação/mortalidade , Distribuição por Idade , Idoso , Feminino , Humanos , Incidência , Pessoa de Meia-Idade , Medição de Risco/métodos , Fatores de Risco , Espanha/epidemiologia , Análise de Sobrevida , Taxa de Sobrevida
16.
Artigo em Inglês | MEDLINE | ID: mdl-19964509

RESUMO

The purpose of this paper is to provide a comparison between the different methods utilized for building up anthropomorphic phantoms in Radiotherapy Treatment Plans. A simplified model of the Snyder Head Phantom was used in order to construct an analytical, voxelized and volumized phantom, throughout a segmentation program and different algorithms programmed in Matlab code. The irradiation of the resulting phantoms was simulated with the MCNP5 (Monte Carlo N-Particle) transport code, version 5, and the calculations presented in particle flux maps inside the phantoms by utilizing the FMESH tool, superimposed mesh tally. The different variables involved in the simulation were analyzed, like particle flux, MCNP standard deviation and real simulation CPU time cost. In the end the volumized model resulted to have the largest computer time cost and bigger discrepancies in the particle flux distribution.


Assuntos
Imagens de Fantasmas/estatística & dados numéricos , Planejamento da Radioterapia Assistida por Computador/estatística & dados numéricos , Algoritmos , Engenharia Biomédica , Simulação por Computador , Cabeça , Humanos , Método de Monte Carlo
17.
Artigo em Inglês | MEDLINE | ID: mdl-19965234

RESUMO

This work is focused on developing a methodology to obtain portal dosimetry with an amorphous silicon Electronic Portal Image Device (a-Si EPID) used in radiotherapy by means of Monte Carlo simulations and experimental measures. Pixel intensity values from portal images have been compared with dose measured from an ionization chamber and dose calculated from Monte Carlo simulations. To this end, several images were acquired with the Elekta iView GT EPID using an attenuator phantom slab (10 cm thickness of solid water) and a 6 MeV photon energy beam with different monitor units settings (MU). The average pixel value in a region of interest (ROI) centered at the beam for each image was extracted and compared to dose measures performed with an ionization chamber. These parameters were found to be linearly related with the number of monitor units. Since MCNP5 simulations allow calculating the deposited dose in the ROI within the phosphor layer of the EPID model, we could compare the portal dose with the simulated transit dose in order to perform a treatment control.


Assuntos
Radiometria/instrumentação , Planejamento da Radioterapia Assistida por Computador/instrumentação , Radioterapia de Intensidade Modulada/instrumentação , Algoritmos , Simulação por Computador , Desenho de Equipamento , Humanos , Método de Monte Carlo , Imagens de Fantasmas , Fótons , Doses de Radiação , Radiometria/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Raios X
18.
Artigo em Inglês | MEDLINE | ID: mdl-19162682

RESUMO

Mammographic phantom images are usually used to study the quality of images obtained by determined mammographic equipment. The digital image treatment techniques allow carrying out an automatic analysis of the phantom image. Nowadays, the digital radiographic equipments are replacing the traditional film-screen equipments and it is necessary to update the parameters to guarantee the quality of the process. In this work we apply some techniques of digital image processing to compute a specific image quality indexes for mammographic phantoms, namely CIRS SP01 and CDMAM 3.4. to study the evolution of this parameter with different varying conditions of the mammographic equipment. The indexes are calculated from a scoring system based on a designed algorithm which analyses the phantom image by means of an automatic detection of the test objects in each phantom.


Assuntos
Mamografia/instrumentação , Mamografia/normas , Imagens de Fantasmas/normas , Garantia da Qualidade dos Cuidados de Saúde/normas , Intensificação de Imagem Radiográfica/instrumentação , Intensificação de Imagem Radiográfica/normas , Interpretação de Imagem Radiográfica Assistida por Computador/instrumentação , Interpretação de Imagem Radiográfica Assistida por Computador/normas , Controle de Qualidade , Espanha
19.
Artigo em Inglês | MEDLINE | ID: mdl-19163410

RESUMO

The present work is centered in reconstructing by means of a scatter analysis method the primary beam photon spectrum of a linear accelerator. This technique is based on irradiating the isocenter of a rectangular block made of methacrylate placed at 100 cm distance from surface and measuring scattered particles around the plastic at several specific positions with different scatter angles. The MCNP5 Monte Carlo code has been used to simulate the particles transport of mono-energetic beams to register the scatter measurement after contact the attenuator. Measured ionization values allow calculating the spectrum as the sum of mono-energetic individual energy bins using the Schiff Bremsstrahlung model. The measurements have been made in an Elekta Precise linac using a 6 MeV photon beam. Relative depth and profile dose curves calculated in a water phantom using the reconstructed spectrum agree with experimentally measured dose data to within 3%.


Assuntos
Aceleradores de Partículas , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Espalhamento de Radiação , Análise Espectral/métodos , Algoritmos , Simulação por Computador , Desenho de Equipamento , Humanos , Íons , Modelos Estatísticos , Método de Monte Carlo , Fótons , Dosagem Radioterapêutica , Reprodutibilidade dos Testes
20.
Artigo em Inglês | MEDLINE | ID: mdl-18002994

RESUMO

Dose reduction in pediatric explorations is especially important because of children radiation sensitivity. According to this, with the aim of saving radiation exposure in future clinical practice, we have developed a technique to control delivered dose in pediatric radiographic exams. To that, a computer science program has been developed to calculate entrance skin dose (ESD) provided by AGFA radiology digital system, using the "lgM" parameter exported from Dicom files. ESD values are compared with dose limits established in regulations to detect if children are being exposed to excessive amounts of radiation during their explorations.


Assuntos
Doses de Radiação , Intensificação de Imagem Radiográfica/métodos , Software , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Intensificação de Imagem Radiográfica/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA