Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Thorac Imaging ; 31(6): 380-390, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27768631

RESUMO

PURPOSE: Coronary-pulmonary arterial fistulas (CPAFs) are rare coronary artery anomalies that have been described only in limited case reports. This study aims to evaluate the clinical presentation and imaging findings of CPAFs collected from 6 participating medical centers along with CPAFs reported in the literature, to discern any general trends present in CPAFs. MATERIALS AND METHODS: A total of 25 cases of CPAF diagnosed by coronary computed tomography angiography were collected across 6 participating institutions. In addition, utilizing a PubMed literature search, 78 additional CPAF cases were obtained. The imaging findings and relevant clinical history were reviewed. RESULTS: Of the 103 CPAF patients, 60 (63% of patients with sex known) were male, with ages ranging from newborn to 88 years (mean=46.1 y). The most common symptoms reported were chest pain (n=40, 39%) and dyspnea (n=26, 25%), with a murmur as the most common physical examination finding (n=38, 37%). The most common coronary artery of origin for a CPAF was the left main/left anterior descending (n=87, 84%), followed by the right coronary artery (n=39, 38%). The fistula most commonly terminated in the main pulmonary artery (n=92, 89%). Multiple CPAFs were present in 46 cases (45%). Coronary artery aneurysms were identified in 20 cases (19%). Pediatric CPAF cases were usually associated with pulmonary atresia with ventricular septal defect. CONCLUSIONS: CPAFs are seen in a variety of clinical settings, from infants with advanced congenital heart disease to elderly patients who have undergone revascularization surgery. Although coronary artery fistulas have previously been described as rarely involving multiple coronary arteries, with the right coronary artery being most often involved, our series demonstrates that multiple fistulas are commonly present, with the most common pattern being between the left main/left anterior descending and the main pulmonary trunk.


Assuntos
Fístula Artério-Arterial/diagnóstico por imagem , Anomalias dos Vasos Coronários/diagnóstico por imagem , Artéria Pulmonar/anormalidades , Artéria Pulmonar/diagnóstico por imagem , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Vasos Coronários/diagnóstico por imagem , Humanos
2.
J Cardiovasc Magn Reson ; 16: 47, 2014 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-24996808

RESUMO

BACKGROUND: We sought to evaluate the effect of application of the revised 2010 Task Force Criteria (TFC) on the prevalence of major and minor Cardiovascular Magnetic Resonance (CMR) criteria for Arrhythmogenic Right Ventricular Cardiomyopathy (ARVC) versus application of the original 1994 TFC. We also assessed the utility of MRI to identify alternative diagnoses for patients referred for ARVC evaluation. METHODS: 968 consecutive patients referred to our institution for CMR with clinical suspicion of ARVC from 1995 to 2010, were evaluated for the presence of major and minor CMR criteria per the 1994 and 2010 ARVC TFC. CMR criteria included right ventricle (RV) dilatation, reduced RV ejection fraction, RV aneurysm, or regional RV wall motion abnormalities. When quantitative measures of RV size and function were not available, and in whom abnormal size or function was reported, a repeat quantitative analysis by 2 qualified CMR physicians in consensus. RESULTS: Of 968 patients, 220 (22.7%) fulfilled either a major or a minor 1994 TFC, and 25 (2.6%) fulfilled any of the 2010 TFC criterion. Among patients meeting any 1994 criteria, only 25 (11.4%) met at least one 2010 criterion. All patients who fulfilled a 2010 criteria also satisfied at least one 1994 criterion. Per the 2010 TFC, 21 (2.2%) patients met major criteria and 4 (0.4%) patients fulfilled at least one minor criterion. Eight patients meeting 1994 minor criteria were reclassified as satisfying 2010 major criteria, while 4 patients fulfilling 1994 major criteria were reclassified to only minor or no criteria under the 2010 TFC.Eighty-nine (9.2%) patients had alternative cardiac diagnoses, including 43 (4.4%) with clinically significant potential ARVC mimics. These included cardiac sarcoidosis, RV volume overload conditions, and other cardiomyopathies. CONCLUSIONS: Application of the 2010 TFC resulted in reduction of total patients meeting any diagnostic CMR criteria for ARVC from 22.7% to 2.6% versus the 1994 TFC. CMR identified alternative cardiac diagnoses in 9.2% of patients, and 4.4% of the diagnoses were potential mimics of ARVC.


Assuntos
Displasia Arritmogênica Ventricular Direita/diagnóstico , Ventrículos do Coração/patologia , Imageamento por Ressonância Magnética/normas , Miocárdio/patologia , Adulto , Displasia Arritmogênica Ventricular Direita/classificação , Displasia Arritmogênica Ventricular Direita/epidemiologia , Displasia Arritmogênica Ventricular Direita/patologia , Displasia Arritmogênica Ventricular Direita/fisiopatologia , Meios de Contraste , Diagnóstico Diferencial , Feminino , Fidelidade a Diretrizes , Ventrículos do Coração/fisiopatologia , Humanos , Hipertrofia Ventricular Direita/diagnóstico , Hipertrofia Ventricular Direita/epidemiologia , Hipertrofia Ventricular Direita/patologia , Masculino , Pessoa de Meia-Idade , Contração Miocárdica , Guias de Prática Clínica como Assunto , Valor Preditivo dos Testes , Prevalência , Estudos Retrospectivos , Volume Sistólico , Disfunção Ventricular Direita/diagnóstico , Disfunção Ventricular Direita/epidemiologia , Disfunção Ventricular Direita/patologia , Função Ventricular Direita
3.
Am J Med ; 125(8): 764-72, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22703931

RESUMO

PURPOSE: We aimed to assess the temporal change in radiation doses from coronary computed tomography angiography (CCTA) during a 6-year period. High CCTA radiation doses have been reduced by multiple technologies that, if used appropriately, can decrease exposures significantly. METHODS: A total of 1277 examinations performed from 2005 to 2010 were included. Univariate and multivariable regression analysis of patient- and scan-related variables was performed with estimated radiation dose as the main outcome measure. RESULTS: Median doses decreased by 74.8% (P<.001), from 13.1 millisieverts (mSv) (interquartile range 9.3-14.7) in period 1 to 3.3 mSv (1.8-6.7) in period 4. Factors associated with greatest dose reductions (P<.001) were all most frequently applied in period 4: axial-sequential acquisition (univariate: -8.0 mSv [-9.7 to -7.9]), high-pitch helical acquisition (univariate: -8.8 mSv [-9.3 to -7.9]), reduced tube voltage (100 vs 120 kV) (univariate: -6.4 mSv [-7.4 to -5.4]), and use of automatic exposure control (univariate: -5.3 mSv [-6.2 to -4.4]). CONCLUSIONS: CCTA radiation doses were reduced 74.8% through increasing use of dose-saving measures and evolving scanner technology.


Assuntos
Angiografia Coronária/tendências , Tomografia Computadorizada Multidetectores/tendências , Doses de Radiação , Adulto , Fatores Etários , Idoso , Algoritmos , Índice de Massa Corporal , Técnicas de Imagem de Sincronização Cardíaca/instrumentação , Técnicas de Imagem de Sincronização Cardíaca/tendências , Angiografia Coronária/instrumentação , Relação Dose-Resposta à Radiação , Frequência Cardíaca , Humanos , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores/instrumentação , Lesões por Radiação/prevenção & controle , Proteção Radiológica/instrumentação , Estados Unidos
4.
J Cardiovasc Comput Tomogr ; 6(1): 24-30, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22222164

RESUMO

BACKGROUND: Evaluation of left ventricular (LV) volumes and ejection fraction (LVEF) represent important components of pharmacologic stress imaging with either myocardial CT perfusion (CTP) or gated single-photon emission CT (SPECT) myocardial perfusion imaging (SPECT-MPI). OBJECTIVES: We compared measurements of left ventricular function and volumes obtained with CTP and SPECT-MPI. METHODS: Forty-seven patients (mean age, 62 ± 11 years; male, n = 39) underwent stress CTP and SPECT-MPI. LVEF (in %), end-systolic volume (ESV; in mL), and end-diastolic volume (EDV; in mL) derived from stress CTP images were compared with SPECT-MPI. RESULTS: Stress CTP was in good agreement with SPECT-MPI for quantification of LVEF (r = 0.91), EDV (r = 0.75), and ESV (r = 0.83; all P < 0.001). The mean LVEF measured by stress CTP (66% ± 17%) was similar to SPECT-MPI (64% ± 15%). Similar values were also derived for mean EDV (123 ± 30 mL vs 120 ± 34 mL) and ESV (44 ± 28 mL vs 51 ± 34 mL) for CTP and SPECT-MPI, respectively. Good agreement was also shown between both techniques for the assessment of regional wall motion with identical wall motion scores in 95.3% of the segments (κ = 0.79). CONCLUSIONS: LVEF and LV volume parameters as determined by dual-source 64-slice adenosine stress CTP show a high correlation with values obtained with stress-gated SPECT-MPI.


Assuntos
Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico , Imagem de Perfusão do Miocárdio/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada por Raios X/métodos , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/etiologia , Técnicas de Imagem de Sincronização Cardíaca/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Volume Sistólico
5.
J Cardiovasc Comput Tomogr ; 5(6): 459-66, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-22146505

RESUMO

BACKGROUND: Myocardial stress computed tomography perfusion (CTP) has similar diagnostic accuracy for detecting perfusion defects (PDs) versus single-photon emission computed tomography (SPECT). However, the optimal diagnostic viewing and image processing parameters for CTP are unknown. OBJECTIVE: We sought to compare the diagnostic accuracy of different image processing techniques, cardiac phases, slice thicknesses, and viewing parameters for detection of PDs. METHODS: A stress and rest dual-source CTP protocol was performed with adenosine. Twelve subjects with severe stenosis proven by quantitative coronary angiography (QCA), with corresponding territorial defects at SPECT, were selected as well as 7 controls (subjects with similar clinical suspicion but negative QCA and SPECT). Short-axis stress images were processed with 3 techniques: minimum intensity projection (MinIP), maximum intensity projection, and average intensity multiplanar reconstruction (MPR), 3 thicknesses (1, 3, 8 mm), and 2 phases (systolic, mid-diastolic). The resulting images (n = 1026) were randomized and interpreted by independent readers. RESULTS: Diastolic reconstructions (8-mm MPR) showed the highest sensitivity (81%) to detect true PDs. The highest accuracy was achieved with the 8-mm (61%) and 1-mm (61%) MPR diastolic images. The most sensitive and accurate systolic reconstructions were 3-mm MinIP images. These findings related to viewing in relatively narrow window width and window level settings. CONCLUSION: Viewing parameters for optimal accuracy in detection of perfusion defects on CTP differ for systolic and diastolic images.


Assuntos
Adenosina , Circulação Coronária , Estenose Coronária/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos , Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada por Raios X , Vasodilatadores , Idoso , Boston , Estudos de Casos e Controles , Angiografia Coronária , Estenose Coronária/fisiopatologia , Estudos de Viabilidade , Feminino , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Estudos Prospectivos , Índice de Gravidade de Doença , Tomografia Computadorizada de Emissão de Fóton Único
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA