Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
Catheter Cardiovasc Interv ; 102(1): 121-137, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37210617

RESUMO

Left circumflex coronary artery (LCx) injury related to mitral valve surgery is a rare complication. The best treatment option is not defined, and percutaneous coronary intervention (PCI) may represent an effective treatment to avoid prolonged myocardial ischemia. To evaluate feasibility and efficacy of PCI treatment, all records of LCx injury related to mitral valve surgery and treated with PCI were included after a systematic PubMed searching. Moreover, we retrospectively analyzed our single-center PCI database and patients fulfilling the inclusion criteria were included. Patients undergoing transcatheter mitral valve intervention, non-mitral valve surgery, conservatively or surgically treated after LCx injury were excluded. Data about patient characteristics, procedural details, PCI success, and in-hospital mortality were collected. Fifty-six patients were included, 58.9% were male (n = 33) and the median age was 60.5 years (IQR = 21.75). The majority had left dominant or codominant coronary system (62.2%, n = 28 and 15.6%, n = 7, respectively). Clinical manifestations ranged from hemodynamic stability (21.1%, n = 8) to hemodynamic instability (42.1%, n = 16) and cardiac arrest (18.4%, n = 7). On ECG, 23.5% of patients (n = 12) presented ST-segment depression, 58.8% (n = 30) ST-segment elevation, 7.8% (n = 4) atrioventricular block, and 29.4% (n = 15) ventricular arrhythmias. Left ventricle dysfunction was present in 52.3% (n = 22) of patients and wall motion abnormalities in 71.4% (n = 30). PCI success rate was 82.1% (n = 46) and in-hospital mortality 4.5% (n = 2). LCx injury related to mitral surgery is a rare complication characterized by an increased risk of mortality. PCI seems a feasible treatment option, still burdened by suboptimal results, probably related to the technical challenges posed by the surgical failure.


Assuntos
Vasos Coronários , Intervenção Coronária Percutânea , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Intervenção Coronária Percutânea/efeitos adversos , Resultado do Tratamento , Estudos Retrospectivos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia
2.
Am J Cardiol ; 195: 98-106, 2023 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-36804737

RESUMO

The Evaluation of XIENCE versus EXCEL (Coronary Artery Bypass Surgery for Effectiveness of Left Main Revascularization) trial is the largest randomized study comparing percutaneous coronary intervention (PCI) with second-generation drug-eluting stents and bypass surgery in unprotected left main disease (ULMD). Our aim was to assess which proportion of patients from a contemporary all-comer population of ULMD PCI would be eligible for the EXCEL trial and whether these patients show different long-term outcomes than the rest of the ULMD population. A total of 246 consecutive patients underwent ULMD PCI between January 2018 and December 2021 and were retrospectively analyzed. After application of the EXCEL trial inclusion and exclusion criteria, 98 patients (39%) were allocated to the "EXCEL-like" cohort and 148 to the "non-EXCEL-like." Baseline characteristics of the 2 groups were substantially comparable. The mean baseline SYNTAX score was lower in the EXCEL-like patients than the non-EXCEL-like group (20.1 ± 7.1 vs 23.0 ± 11.2, p = 0.025), with the latter also showing a higher degree of incomplete revascularization (residual SYNTAX score >8 : 11% vs 26%, p = 0.005). At 1 year, the cumulative major adverse cardiovascular and cerebral events rate was 7% for the EXCEL-like and 17% for the non-EXCEL-like patients, respectively (p = 0.03). At the last follow-up available, the significant difference in major adverse cardiovascular and cerebral events rate persisted (19% vs 37%, p = 0.02) and a significant difference in any unplanned revascularization was also shown (1.5% vs 13%, p = 0.04). In conclusion, in a contemporary real-world cohort of ULMD PCI, only a minority of patients could be enrolled in the EXCEL trial; the EXCEL-like patients, in our population, showed less clinical events at long-term follow-up than the cohort of patients who were ineligible for EXCEL, despite comparable baseline cardiovascular profiles; these findings may challenge a broad external applicability of the results of the EXCEL trial in routine clinical activity.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Humanos , Intervenção Coronária Percutânea/métodos , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento , Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/etiologia
3.
EuroIntervention ; 18(16): e1339-e1347, 2023 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-36602883

RESUMO

BACKGROUND: R-One is a robotic percutaneous coronary intervention (PCI) system (CE mark 2019) designed to reduce operator radiation exposure, improve ergonomics, and accurately navigate, position, and deliver guidewires/devices during PCI. AIMS: We aimed to evaluate the safety and efficacy of the R-One system for PCI. METHODS: The European multicentre prospective R-EVOLUTION study included patients with a de novo coronary artery stenosis (length <38 mm, reference diameter 2.5-4.0 mm) undergoing stent implantation. Patients with recent ST-segment elevation myocardial infarction, ostial or left main lesion, bifurcation, severe tortuosity, or calcification were excluded. Clinical success was defined as the absence of major intraprocedural complications. Technical success was defined as the successful advancement and retraction of all PCI devices (guidewires/balloon/stents) without total manual conversion. Radiation exposure to patients, to a simulated manual operator, and to robotic PCI operators was measured. RESULTS: Sixty-two consecutive patients (B2/C lesions: 25.0% [16/64]) underwent robotic PCI. Radial access was used in 96.8% (60/62) of procedures. The mean robotic procedure duration was 19.9±9.6 min and the mean fluoroscopy time was 10.3±5.4 min. Clinical success was 100% with no complications at 30 days. Technical success was 95.2% (59/62). Total manual conversion was required in 4.8% (3/62) cases, with 1 case directly related to the robotic system. Operator radiation exposure was reduced by 84.5% under and 77.1% on top of the lead apron, compared to doses received on the patient table. CONCLUSIONS: This study suggests that robotic PCI using R-One is safe and effective with markedly lower radiation exposure to the operator. Further studies are needed to evaluate R-One in larger patient populations with more complex lesions. (ClinicalTrials.gov: NCT04163393).


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Intervenção Coronária Percutânea , Procedimentos Cirúrgicos Robóticos , Humanos , Angiografia Coronária , Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/etiologia , Estenose Coronária/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Estudos Prospectivos , Resultado do Tratamento
4.
Acta Cardiol ; 77(10): 960-969, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36326198

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) has been adopted as an alternative to surgery in severe aortic stenosis treatment, even in low-intermediate risk. The aim of this study is to retrospectively report our single-centre 13-year TAVI experience with emphasis on learning curve, referral indication and trends in outcomes over time. METHODS: We included 361 consecutive patients who underwent TAVI from January 2008 to December 2020, grouped according to similar per-year volume of procedures: G1 (2008-2014), G2 (2015-2017) and G3 (2018-2020). RESULTS: The number of procedures increased (group size: 59 vs. 106 vs. 196). No major differences were observed in STS-PROM and EuroSCORE-II between groups, despite TAVI in patients with prior surgical revascularisation was mainly performed in G1. Trans-femoral approach raised from 80.8 to 93.4%, while the most common alternative access was trans-subclavian. The pre-dilation rate was higher in G1 with lower prosthesis post-dilation rate. The length of hospital stay decreased in time by 30%. At 30 days a reduction in all-cause mortality, vascular complications, bleedings and para-valvular leak combined with higher rate of permanent pacing were observed over the groups. At 1-year there was no difference in all-cause mortality but over 30% reduction in cardiovascular death (8.5 vs. 7.5 vs. 5.6%). CONCLUSIONS: Favourable trends were observed across the groups, with an improvement in periprocedural outcomes and cardiovascular mortality at 1-year. These improvements could depend on increased expertise because mortality reduction was noted only after reaching a significant procedure volume. A trend towards lower risk patients selection was present in our cohort, as previously described worldwide.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Bélgica/epidemiologia , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos
5.
Int J Cardiol ; 337: 29-37, 2021 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-34029618

RESUMO

INTRODUCTION: Refractory angina (RA) is considered the end-stage of coronary artery disease, and often has no interventional treatment options. Coronary sinus Reducer (CSR) is a recent addition to the therapeutic arsenal, but its efficacy has only been evaluated on small populations. The RESOURCE registry provides further insights into this therapy. METHODS: The RESOURCE is an observational, retrospective registry that includes 658 patients with RA from 20 centers in Europe, United Kingdom and Israel. Prespecified endpoints were the amelioration of anginal symptoms evaluated with the Canadian Cardiovascular Society (CCS) score, the rates of procedural success and complications, and MACEs as composite of all-cause mortality, acute coronary syndromes, and stroke. RESULTS: At a median follow-up of 502 days (IQR 225-1091) after CSR implantation, 39.7% of patients improved by ≥2 CCS classes (primary endpoint), and 76% by ≥1 class. Procedural success was achieved in 96.7% of attempts, with 3% of procedures aborted mostly for unsuitable coronary sinus anatomy. Any complication occurred in 5.7% of procedures, but never required bailout surgery nor resulted in intra- or periprocedural death or myocardial infarction. One patient developed periprocedural stroke after inadvertent carotid artery puncture. At the last available follow-up, overall mortality and MACE were 10.4% and 14.6% respectively. At one, three and five years, mortality rate at Kaplan-Meier analysis was 4%, 13.7%, and 23.4% respectively. CONCLUSIONS: CSR implantation is safe and reduces angina in patients with refractory angina.


Assuntos
Seio Coronário , Canadá , Seio Coronário/diagnóstico por imagem , Seio Coronário/cirurgia , Europa (Continente)/epidemiologia , Humanos , Israel , Estudos Retrospectivos , Resultado do Tratamento , Reino Unido/epidemiologia
8.
J Vasc Interv Radiol ; 29(8): 1158-1166, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29921526

RESUMO

PURPOSE: To report results of renal denervation (RDN) with the first catheter-based, non-balloon occlusion ultrasonic system in patients with resistant hypertension. MATERIALS AND METHODS: In a multicenter, single-arm trial, 39 patients with resistant hypertension (defined as uncontrolled hypertension while taking ≥ 3 antihypertensive medications) were treated. The cohort consisted of 4 groups: severe resistant hypertension (office systolic blood pressure [OSBP] ≥ 160 mm Hg) treated with a unidirectional catheter (group 1; n = 14); severe resistant hypertension treated with a multidirectional catheter (group 2; n = 18); moderate resistant hypertension (OSBP 140-159 mm Hg) treated with a multidirectional catheter (group 3; n = 5); and recurrent severe resistant hypertension, after an initial response to RF RDN (group 4; n = 2). Blood pressure monitoring was performed for 6 months. RESULTS: Severe adverse events were not noted immediately after the procedure or during follow-up. Treatment time was longer with unidirectional than with multidirectional catheters (36.7 min ± 9.6 vs 11.9 min ± 5.8; P < .001). Mean reductions in office blood pressure (systolic/diastolic) at 1, 3, and 6 months were -26.1/-9.6 mm Hg, -28.0/-9.9 mm Hg, and -30.6/-14.1 mm Hg (P < .01 for all). Per-group analysis showed significant OSBP reduction for groups 1 and 2. Patients with isolated systolic hypertension had a significantly smaller reduction in OSBP after 6 months compared with patients with combined systolic/diastolic hypertension (-16.2 mm Hg ± 18.5 vs -9.9 mm Hg ± 33.4; P < .005). CONCLUSIONS: Use of the RDN system was feasible and safe in this phase I study. Significant blood pressure reductions were observed over 6 months, although less in patients with isolated systolic hypertension.


Assuntos
Denervação Autônoma/métodos , Pressão Sanguínea , Ablação por Cateter , Hipertensão/cirurgia , Rim/irrigação sanguínea , Artéria Renal/inervação , Procedimentos Cirúrgicos Ultrassônicos , Idoso , Anti-Hipertensivos/uso terapêutico , Austrália , Denervação Autônoma/efeitos adversos , Denervação Autônoma/instrumentação , Pressão Sanguínea/efeitos dos fármacos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/instrumentação , Catéteres , Resistência a Medicamentos , Quimioterapia Combinada , Europa (Continente) , Estudos de Viabilidade , Feminino , Humanos , Hipertensão/diagnóstico , Hipertensão/fisiopatologia , Israel , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento , Procedimentos Cirúrgicos Ultrassônicos/efeitos adversos , Procedimentos Cirúrgicos Ultrassônicos/instrumentação , Ultrassonografia de Intervenção
9.
EuroIntervention ; 12(6): 748-56, 2016 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-26448576

RESUMO

AIMS: In the last 10 years, cryotherapy has been investigated as a new technology to treat vascular disease. The efficiency of cryotherapy in stabilising atherosclerotic plaques has never been described. The purpose of the present study was to evaluate the effect of catheter-based cryotherapy on atherosclerotic plaque composition in a rabbit model of atherosclerosis. METHODS AND RESULTS: Twenty-four New Zealand white rabbits were fed a 0.3% cholesterol-supplemented diet for 24 weeks. At two predefined sites of the atherosclerotic thoracic aorta, catheter-based cryotherapy, applying either single-dose, double-dose cryotherapy or control inflation, was performed after randomisation. Rabbits were continued on a cholesterol-supplemented diet for one day (acute) or four weeks (chronic). One day after cryotherapy, apoptotic cell death of smooth muscle cells (SMCs) and endothelial cells (ECs) was observed, whereas macrophages were unaffected. Four weeks later, the amount of SMCs was restored, the EC layer was regenerated, and a subendothelial macrophage-free layer was formed, indicative of a more stable plaque. In addition, both the thickness and the type I collagen content of the fibrous cap were increased. CONCLUSIONS: The present study demonstrated that cryotherapy is feasible and appears to stabilise atherosclerotic plaques in a rabbit model.


Assuntos
Aterosclerose/terapia , Crioterapia , Animais , Aorta Torácica/patologia , Apoptose , Aterosclerose/imunologia , Aterosclerose/metabolismo , Aterosclerose/patologia , Colágeno Tipo I/metabolismo , Modelos Animais de Doenças , Células Endoteliais/metabolismo , Macrófagos , Miócitos de Músculo Liso/metabolismo , Coelhos , Calcificação Vascular/patologia , Molécula 1 de Adesão de Célula Vascular/metabolismo
11.
Am J Cardiol ; 115(8): 1056-62, 2015 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-25726380

RESUMO

Although smoking is a risk factor for coronary atherosclerosis, the age-related impact on lesion morphology has not been studied. The aim of this study was to assess the age-related impact of smoking on the extent of atherosclerosis and arterial remodeling. In Providing Regional Observations to Study Predictors of Events in the Coronary Tree, 687 patients with acute coronary syndrome underwent 3-vessel gray scale and virtual histology intravascular ultrasound imaging of 3,185 nonculprit lesions. In 207 patients ≤65 years, current (smoking within 1 month) and former (no smoking for >1 month) smokers showed significantly smaller normalized volumes of external elastic membrane (EEM), lumen, and P + M (plaque + media) compared with nonsmokers. At the minimal lumen area site, current and former smokers had significantly smaller EEM, lumen, and P + M areas than nonsmokers. Conversely, in 480 patients >65 years, current smokers had greater normalized P + M volumes than nonsmokers with no difference in normalized EEM or lumen volumes. Finally, in patients >65 years (but not in patients ≤65 years), current smokers showed more plaque ruptures (4.7% vs 1.8%, p = 0.05) and echolucent plaques (8.3% vs 3.9%, p = 0.05) compared with nonsmokers. On multivariable analysis, a history of smoking (combining current and former smoking) predicted smaller normalized EEM volumes compared with nonsmokers ≤65 years. In conclusion, in patients ≤65 years, but not in patients >65 years, smoking had a vascular constrictive effect that contributed to severe luminal stenosis. Conversely, smokers >65 years had more plaque with greater plaque instability.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Placa Aterosclerótica/diagnóstico por imagem , Fumar/efeitos adversos , Ultrassonografia de Intervenção/métodos , Interface Usuário-Computador , Idoso , Doença da Artéria Coronariana/epidemiologia , Doença da Artéria Coronariana/patologia , Feminino , Seguimentos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Placa Aterosclerótica/epidemiologia , Placa Aterosclerótica/patologia , Valor Preditivo dos Testes , Estudos Prospectivos , Índice de Gravidade de Doença , Estados Unidos/epidemiologia
12.
EuroIntervention ; 11(5): 541-8, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25136883

RESUMO

AIMS: To report the six-month angiographic and two-year clinical outcome data from the first-in-man study with the Ultimaster DES, a thin-strut cobalt-chromium sirolimus-eluting stent (SES) with an innovative abluminal-gradient-coated bioresorbable polymer. METHODS AND RESULTS: CENTURY is a multicentre, single-arm, prospective study that enrolled 105 patients (113 lesions) with coronary artery disease. All patients were scheduled to have an angiographic follow-up at six months, while 45 and 20 patients respectively had IVUS and OCT assessments. The primary endpoint was six-month in-stent late lumen loss. Secondary endpoints included clinical, IVUS and OCT outcomes. Clinical follow-up is available up to two years and will continue up to five years. Procedural success was 97.1% and device success was 100%. Angiographic late loss at six months was 0.04±0.35 mm, also reflected in a low binary restenosis rate of 0.9% and confirmed by IVUS-assessed neointimal volume obstruction of 1.02±1.62%. The mean strut coverage assessed by OCT was 96.2% with 1.66±4.02 malapposed stent struts. There were no deaths in the study, three (2.9%) periprocedural and one (0.9%) spontaneous myocardial infarction, not related to the target vessel. At one and two years, the target lesion failure rate was 3.8% and 5.7%, while the TLR rate was 1.9% and 2.8%, respectively. There was one acute definite stent thrombosis. CONCLUSIONS: The Ultimaster™ novel bioresorbable polymer sirolimus-eluting stent demonstrated good performance, including high procedural success and strong suppression of neointimal proliferation at six months. Good safety and effectiveness were shown up to two years in the studied population.


Assuntos
Antibióticos Antineoplásicos/uso terapêutico , Ligas de Cromo , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Neointima , Intervenção Coronária Percutânea , Polímeros , Sirolimo/uso terapêutico , Implantes Absorvíveis , Idoso , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/terapia , Estudos Prospectivos , Tomografia de Coerência Óptica , Resultado do Tratamento , Ultrassonografia de Intervenção
13.
EuroIntervention ; 10(12): 1383-90, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24801119

RESUMO

AIMS: To compare the efficacy and safety of the MiStent absorbable polymer sirolimus-eluting stent (APSES) with a zotarolimus-eluting stent (ZES). METHODS AND RESULTS: The trial was a 2:1 randomisation at 26 sites of 184 patients implanted with an APSES (n=123) versus a ZES (n=61). Following stent implantation, all patients underwent quantitative coronary angiography at baseline and at nine months of follow-up, while a select subgroup also underwent optical coherence tomography (OCT). The primary efficacy hypothesis was superiority of in-stent late lumen loss (LLL) of APSES compared to ZES. At nine months, the primary endpoint was met, with a mean in-stent LLL of 0.27±0.46 mm in 103 APSES patients versus 0.58±0.41 mm in 52 ZES patients (p<0.001). The proportion of uncovered stent struts by OCT at nine months was very low in both groups. The mean neointimal thickness of covered struts (p=0.002) and percent net volume obstruction (p≤0.003) were significantly lower in the APSES than in the ZES group. Major adverse cardiac event and stent thrombosis rates were low and comparable between groups. CONCLUSIONS: The DESSOLVE II trial demonstrated superiority in the primary efficacy endpoint of nine-month mean LLL for APSES compared to ZES. Strut coverage by OCT was high with both stents and the clinical safety endpoints including stent thrombosis were equally low in both groups. ClinicalTrials.gov Identifier: NCT01294748.


Assuntos
Implantes Absorvíveis , Antibióticos Antineoplásicos/uso terapêutico , Reestenose Coronária/patologia , Estenose Coronária/terapia , Stents Farmacológicos , Neointima/patologia , Intervenção Coronária Percutânea/métodos , Sirolimo/análogos & derivados , Sirolimo/uso terapêutico , Idoso , Angiografia Coronária , Reestenose Coronária/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neointima/diagnóstico por imagem , Polímeros , Método Simples-Cego , Tomografia de Coerência Óptica , Resultado do Tratamento
14.
J Am Coll Cardiol ; 64(17): 1814-9, 2014 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-25443704

RESUMO

BACKGROUND: Mitral regurgitation (MR) is the most common valvular heart disease, and mitral valve surgery is the gold standard therapy for severe MR. Many patients with severe MR are not referred for surgery because of old age, comorbidities, or severe left ventricular dysfunction. Transcatheter mitral valve implantation may be a better therapeutic option for these high-risk patients with severe symptomatic MR. OBJECTIVES: This study sought to describe the first-in-man series of transapical mitral valve implantation for mitral regurgitation with the TIARA device. METHODS: Extensive preclinical ex vivo and animal studies were conducted with the transapical mitral valve implantation of the Tiara system. The first 2 cases of human implantation were successfully performed in a 73-year-old man and a 61-year-old woman with severe functional MR. Both patients were in New York Heart Association class IV heart failure with depressed left ventricular ejection fraction, pulmonary hypertension, and additional comorbidities. RESULTS: The valve was implanted uneventfully in both patients. General anesthesia and transapical access were used. Patients were hemodynamically stable with no need for cardiopulmonary bypass. Immediately after implantation, systemic arterial pressure and stroke volume increased and pulmonary pressure decreased dramatically. There were no intraoperative complications, and both patients were extubated in the operating room. Post-procedural echocardiograms at 48 h, 1 month, and 2 months demonstrated excellent prosthetic valve function with a low transvalvular gradient and no left ventricular outflow tract obstruction. There was a trivial paravalvular leak in the first patient at 48 h, which was completely resolved at subsequent studies; no paravalvular leak occurred in the second patient. CONCLUSIONS: Transapical transcatheter mitral valve implantation is technically feasible and can be performed safely. Early hemodynamic performance of the prosthesis was excellent. Transcatheter mitral valve implantation may become an important treatment option for patients with severe MR who are at high operative risk.


Assuntos
Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas/efeitos adversos , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Idoso , Bioprótese/efeitos adversos , Comorbidade , Feminino , Humanos , Hipertensão Pulmonar/complicações , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Índice de Gravidade de Doença , Resultado do Tratamento , Disfunção Ventricular Esquerda/fisiopatologia
15.
EuroIntervention ; 10 Suppl U: U115-9, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25256324

RESUMO

Mitral valve surgery is the gold standard therapy for severe mitral regurgitation, but can be associated with significant morbidity and mortality. Percutaneous mitral leaflet repair has recently been established as a viable alternative to surgery, but many patients are ineligible and repair may not be optimal. Transcatheter mitral valve implantation may be an alternate therapeutic option, particularly for high-risk patients. We outline the initial preclinical and first-in-human experience with the Tiara transapical mitral valve implantation system, highlighting the ease of implantation, proven feasibility and excellent haemodynamic performance.


Assuntos
Bioprótese , Procedimentos Endovasculares , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Valva Mitral , Idoso , Animais , Bovinos , Humanos , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/cirurgia
16.
Basic Res Cardiol ; 108(1): 321, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23233268

RESUMO

Autophagy is a reparative, life-sustaining process by which cytoplasmic components are sequestered in double membrane vesicles and degraded upon fusion with lysosomal compartments. Mice with a macrophage-specific deletion of the essential autophagy gene Atg5 develop plaques with increased apoptosis and oxidative stress as well as enhanced plaque necrosis. This finding indicates that basal autophagy in macrophages is anti-apoptotic and present in atherosclerotic plaques to protect macrophages against various atherogenic stressors. However, autophagy is impaired in advanced stages of atherosclerosis and its deficiency promotes atherosclerosis in part through activation of the inflammasome. Because basal autophagy can be intensified selectively in macrophages by specific drugs such as mammalian target of rapamycin (mTOR) inhibitors or Toll-like receptor 7 (TLR7) ligands, these drugs were recently tested as potential plaque stabilizing compounds. Stent-based delivery of the mTOR inhibitor everolimus promotes a stable plaque phenotype, whereas local administration of the TLR7 ligand imiquimod stimulates inflammation and plaque progression. Therefore, more drugs capable of inducing autophagy should be tested in plaque macrophages to evaluate the feasibility of this approach. Given that drug-induced macrophage autophagy is associated with pro-inflammatory responses due to cytokine release, induction of postautophagic necrosis or activation of phagocytes after clearance of the autophagic corpse, cotreatment with anti-inflammatory compounds may be required. Overall, this review highlights the pros and cons of macrophage autophagy as a drug target for plaque stabilization.


Assuntos
Autofagia/efeitos dos fármacos , Macrófagos/efeitos dos fármacos , Placa Aterosclerótica/tratamento farmacológico , Aminoquinolinas/farmacologia , Animais , Citocinas/biossíntese , Everolimo , Humanos , Imiquimode , Macrófagos/fisiologia , Camundongos , Placa Aterosclerótica/induzido quimicamente , Sirolimo/análogos & derivados , Sirolimo/farmacologia , Serina-Treonina Quinases TOR/fisiologia , Receptor 7 Toll-Like/fisiologia
17.
JACC Cardiovasc Interv ; 5(12): 1209-19, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23257368

RESUMO

OBJECTIVES: This study sought to investigate whether self-expanding stents are more effective than balloon-expandable stents for reducing stent malapposition at 3 days after implantation in patients with ST-segment elevation myocardial infarction undergoing primary percutaneous coronary intervention. BACKGROUND: Acute myocardial infarction is associated with vasoconstriction and large thrombus burden. Resolution of vasoconstriction and thrombus load during the first hours to days after primary percutaneous coronary intervention may lead to stent undersizing and malapposition, which may subsequently lead to stent thrombosis or restenosis. In addition, aggressive stent deployment may cause distal embolization. METHODS: Eighty patients with ST-segment elevation myocardial infarction undergoing primary percutaneous coronary intervention were randomized to receive a self-expanding stent (STENTYS, STENTYS SA, Paris, France) (n = 43) or a balloon-expandable stent (VISION, Abbott Vascular, Santa Clara, California; or Driver, Medtronic, Minneapolis, Minnesota) (n = 37) at 9 European centers. The primary endpoint was the proportion of stent strut malapposition at 3 days after implantation measured by optical coherence tomography. Secondary endpoints included major adverse cardiac events (cardiac death, recurrent myocardial infarction, emergent bypass surgery, or clinically driven target lesion revascularization). RESULTS: At 3 days after implantation, on a per-strut basis, a lower rate of malapposed stent struts was observed by optical coherence tomography in the self-expanding stent group than in the balloon-expandable group (0.58% vs. 5.46%, p < 0.001). On a per-patient basis, none of the patients in the self-expanding stent group versus 28% in the balloon-expandable group presented ≥5% malapposed struts (p < 0.001). At 6 months, major adverse cardiac events were 2.3% versus 0% in the self-expanding and balloon-expandable groups, respectively (p = NS). CONCLUSIONS: Strut malapposition at 3 days is significantly lower in ST-segment elevation myocardial infarction patients allocated to self-expanding stents when than in those allocated to balloon-expandable stents. The impact of this difference on clinical outcome and the risk of late stent thrombosis need to be evaluated further. (Randomized Comparison Between the STENTYS Self-expanding Coronary Stent and a Balloon-expandable Stent in Acute Myocardial Infarction [APPOSITION II]; NCT01008085).


Assuntos
Infarto do Miocárdio/cirurgia , Intervenção Coronária Percutânea , Stents , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/fisiopatologia , Complicações Pós-Operatórias/prevenção & controle , Desenho de Prótese , Falha de Prótese
19.
Arterioscler Thromb Vasc Biol ; 32(5): 1228-35, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22345170

RESUMO

OBJECTIVE: Stent-based delivery of the mammalian target of rapamycin (mTOR) inhibitor everolimus is a promising strategy for the treatment of coronary artery disease. We studied potential adverse effects associated with mTOR inhibition. METHODS AND RESULTS: Macrophages in culture were either treated with everolimus or starved to inhibit mTOR. Everolimus led to inhibition of protein translation, activation of p38 MAPK, and the release of proinflammatory cytokines (eg, IL-6, TNFα) and chemokines (eg, MCP1, Rantes) before induction of autophagic death. These effects were also observed with rapamycin, but not after starvation. Everolimus-induced cytokine release was similar in macrophages lacking the essential autophagy gene Atg7 but was inhibited when macrophages were cotreated with p38 MAPK inhibitor SB202190 or the glucocorticoid clobetasol. Combined stent-based delivery of clobetasol and everolimus in rabbit plaques downregulated TNFα expression as compared with everolimus-treated plaques but did not affect the ability of everolimus to induce macrophage clearance. CONCLUSIONS: mTOR inhibition by everolimus triggers cytokine release in macrophages through inhibition of protein translation and p38 activation. These findings provide a rationale for combined local treatment of atherosclerotic plaques with everolimus and an anti-inflammatory agent.


Assuntos
Doença da Artéria Coronariana/cirurgia , Citocinas/biossíntese , Stents Farmacológicos , Glucocorticoides/farmacologia , Macrófagos/metabolismo , Sirolimo/análogos & derivados , Animais , Autofagia/efeitos dos fármacos , Western Blotting , Sobrevivência Celular , Células Cultivadas , Doença da Artéria Coronariana/metabolismo , Doença da Artéria Coronariana/patologia , Modelos Animais de Doenças , Ensaio de Imunoadsorção Enzimática , Everolimo , Humanos , Imuno-Histoquímica , Macrófagos/efeitos dos fármacos , Macrófagos/ultraestrutura , Camundongos , Microscopia Eletrônica de Transmissão , Desenho de Prótese , Coelhos , Sirolimo/farmacologia
20.
J Am Coll Cardiol ; 59(15): 1371-6, 2012 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-22284328

RESUMO

OBJECTIVES: This study sought to demonstrate the noninferiority of polymer-free amphilimus-eluting stents (Cre8, CID, Saluggia, Italy) versus permanent-polymer paclitaxel-eluting stents (Taxus Liberté, Boston Scientific, Natick, Massachusetts) in de novo percutaneous coronary intervention. BACKGROUND: Although the efficacy of the drug-eluting stent has been well established, the risk-benefit balance is still suboptimal, and the safety of polymers remains uncertain. METHODS: Patients undergoing percutaneous coronary intervention for de novo lesions were randomly assigned 1:1 to Cre8 or Taxus Liberté stents. Primary endpoint was 6-month angiographic in-stent late lumen loss (LLL) within a noninferiority scope. Six-month intravascular ultrasound was performed in 20% of the patients. All patients will be clinically followed up to 5 years. RESULTS: Out of 323 patients enrolled, 162 received Cre8 and 161 Taxus Liberté stents. In-stent LLL was significantly lower in Cre8 group (0.14 ± 0.36 mm vs. 0.34 ± 0.40 mm, p noninferiority <0.0001, p superiority <0.0001). Clinical endpoints (cardiac death, myocardial infarction, target lesion revascularization, and stent thrombosis) up to 12 months did not differ significantly between the groups. CONCLUSIONS: The Cre8 stent in de novo lesions showed significantly lower in-stent LLL at 6 months than the Taxus Liberté stent did, with a trend toward better 12-month clinical safety and efficacy results. (International Randomized Comparison Between DES Limus Carbostent and Taxus Drug-Eluting Stents in the Treatment of De Novo Coronary Lesions [NEXT]; NCT01373502).


Assuntos
Angioplastia Coronária com Balão/métodos , Materiais Revestidos Biocompatíveis , Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos , Paclitaxel/farmacologia , Antineoplásicos Fitogênicos/farmacologia , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Eletrocardiografia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Método Simples-Cego , Resultado do Tratamento , Ultrassonografia de Intervenção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA