Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Med Phys ; 41(2): 021714, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24506605

RESUMO

PURPOSE: Modulated electron radiotherapy (MERT) promises sparing of organs at risk for certain tumor sites. Any implementation of MERT treatment planning requires an accurate beam model. The aim of this work is the development of a beam model which reconstructs electron fields shaped using the Millennium photon multileaf collimator (MLC) (Varian Medical Systems, Inc., Palo Alto, CA) for a Varian linear accelerator (linac). METHODS: This beam model is divided into an analytical part (two photon and two electron sources) and a Monte Carlo (MC) transport through the MLC. For dose calculation purposes the beam model has been coupled with a macro MC dose calculation algorithm. The commissioning process requires a set of measurements and precalculated MC input. The beam model has been commissioned at a source to surface distance of 70 cm for a Clinac 23EX (Varian Medical Systems, Inc., Palo Alto, CA) and a TrueBeam linac (Varian Medical Systems, Inc., Palo Alto, CA). For validation purposes, measured and calculated depth dose curves and dose profiles are compared for four different MLC shaped electron fields and all available energies. Furthermore, a measured two-dimensional dose distribution for patched segments consisting of three 18 MeV segments, three 12 MeV segments, and a 9 MeV segment is compared with corresponding dose calculations. Finally, measured and calculated two-dimensional dose distributions are compared for a circular segment encompassed with a C-shaped segment. RESULTS: For 15 × 34, 5 × 5, and 2 × 2 cm(2) fields differences between water phantom measurements and calculations using the beam model coupled with the macro MC dose calculation algorithm are generally within 2% of the maximal dose value or 2 mm distance to agreement (DTA) for all electron beam energies. For a more complex MLC pattern, differences between measurements and calculations are generally within 3% of the maximal dose value or 3 mm DTA for all electron beam energies. For the two-dimensional dose comparisons, the differences between calculations and measurements are generally within 2% of the maximal dose value or 2 mm DTA. CONCLUSIONS: The results of the dose comparisons suggest that the developed beam model is suitable to accurately reconstruct photon MLC shaped electron beams for a Clinac 23EX and a TrueBeam linac. Hence, in future work the beam model will be utilized to investigate the possibilities of MERT using the photon MLC to shape electron beams.


Assuntos
Elétrons/uso terapêutico , Modelos Biológicos , Método de Monte Carlo , Fótons/uso terapêutico , Algoritmos , Estudos de Viabilidade , Órgãos em Risco/efeitos da radiação , Dosagem Radioterapêutica , Reprodutibilidade dos Testes
2.
Med Phys ; 31(4): 828-31, 2004 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15125000

RESUMO

In external beam radiotherapy, electronic portal imaging becomes more and more an indispensable tool for the verification of the patient setup. For the safe clinical introduction of high dose conformal radiotherapy like intensity modulated radiation therapy, on-line patient setup verification is a prerequisite to ensure that the planned dosimetric coverage of the tumor volume is actually realized in the patient. Since the direction of setup fields often deviates from the direction of the treatment beams, extra dose is delivered to the patient during the acquisition of these portal images which may reach clinical relevance. The aim of this work was to develop a new acquisition mode for the PortalVision aS500 electronic portal imaging device from Varian Medical Systems that allows one to take portal images with reduced dose while keeping good image quality. The new acquisition mode, called RadMode, selectively enables and disables beam pulses during image acquisition allowing one to stop wasting valuable dose during the initial acquisition of "reset frames." Images of excellent quality can be taken with 1 MU only. This low dose per image facilitates daily setup verification with considerably reduced extra dose.


Assuntos
Eletrônica Médica/instrumentação , Análise de Falha de Equipamento/métodos , Garantia da Qualidade dos Cuidados de Saúde/métodos , Radiometria/instrumentação , Planejamento da Radioterapia Assistida por Computador/instrumentação , Radioterapia Conformacional/instrumentação , Doses de Radiação , Proteção Radiológica/instrumentação , Proteção Radiológica/métodos , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
Z Med Phys ; 11(3): 163-70, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11668813

RESUMO

PURPOSE: Study of behavior and influence of a multileaf collimator (MLC) on dose calculation, verification, and portal energy spectra in the case of intensity-modulated fields obtained with a step-and-shoot or a dynamic technique. METHODS: The 80-leaf MLC for the Varian Clinac 2300 C/D was implemented in a previously developed Monte Carlo (MC) based multiple source model (MSM) for a 6 MV photon beam. Using this model and the MC program GEANT, dose distributions, energy fluence maps and energy spectra at different portal planes were calculated for three different MLC applications. RESULTS: The comparison of MC-calculated dose distributions in the phantom and portal plane, with those measured with films showed an agreement within 3% and 1.5 mm for all cases studied. The deviations mainly occur in the extremes of the intensity modulation. The MC method allows to investigate, among other aspects, dose components, energy fluence maps, tongue-and-groove effects and energy spectra at portal planes. CONCLUSION: The MSM together with the implementation of the MLC is appropriate for a number of investigations in intensity-modulated radiation therapy (IMRT).


Assuntos
Método de Monte Carlo , Planejamento da Radioterapia Assistida por Computador/métodos , Simulação por Computador , Humanos , Imagens de Fantasmas , Fótons/uso terapêutico , Reprodutibilidade dos Testes
4.
Ther Umsch ; 55(7): 445-8, 1998 Jul.
Artigo em Alemão | MEDLINE | ID: mdl-9702116

RESUMO

Stereotactic radiosurgery stands for a high precision irradiation concept, which allows to deliver a high dose of ionizing radiation to the tumor volume. The characteristic steep dose fall-off immediately outside the target volume enables the selective destruction of small intracranial tumors while sharply minimizing the dose to the surrounding healthy tissue. This treatment modality is non-invasive and in general well tolerated with minimal side-effects. Especially for palliative concepts the short treatment time is of great importance.


Assuntos
Neoplasias Encefálicas/radioterapia , Radiocirurgia/instrumentação , Desenho de Equipamento , Planejamento de Assistência ao Paciente , Garantia da Qualidade dos Cuidados de Saúde
5.
Strahlenther Onkol ; 174(6): 306-10, 1998 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-9645211

RESUMO

BACKGROUND: Patients with carcinomas of the upper aero-digestive tract often suffer from ear pain as a tumor associated syndrome. This prospective study examines the predictive and prognostic value of this symptom. PATIENTS AND METHODS: Ninety-six consecutive patients who completed a locally radiotherapy of a carcinoma of the oropharynx were prospectively evaluated and followed. Forty-nine out of 96 patients stated the symptom, either spontaneously or after questioning. The 2 groups showed no difference regarding TNM-classification, histology and total dose. Overall survival, local control and disease specific survival were calculated according to Kaplan-Meier and compared by the log-rank test. RESULTS: A clinically complete remission was obtained in significantly fewer patients with reflex-otalgia as compared to patients without reflex-otalgia, 61.2% versus 89.3%, p < 0.002. Local control of patients with reflex-otalgia was significantly less with 49%, mean follow-up 564 days, in comparison to local control in patients without reflex-otalgia, mean follow-up 613 days, p = 0.01. Disease specific survival was significantly worse for patients with reflex-otalgia, p < 0.012. The probability of local control of T1/T2 tumors with reflex-otalgia was similar to T3/T4 tumors without reflex-otalgia. Local control for all tumor categories combined is 74% for patients without reflex-otalgia versus 49% for patients with reflex-otalgia. CONCLUSION: In our patients, reflex-otalgia is a new and statistically significant parameter for the probability of local control and disease specific survival.


Assuntos
Carcinoma de Células Escamosas/radioterapia , Dor de Orelha/radioterapia , Neoplasias Orofaríngeas/radioterapia , Síndromes Paraneoplásicas/radioterapia , Reflexo Anormal/efeitos da radiação , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma de Células Escamosas/mortalidade , Carcinoma de Células Escamosas/patologia , Dor de Orelha/mortalidade , Dor de Orelha/patologia , Feminino , Humanos , Metástase Linfática , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Neoplasias Orofaríngeas/mortalidade , Neoplasias Orofaríngeas/patologia , Síndromes Paraneoplásicas/mortalidade , Síndromes Paraneoplásicas/patologia , Prognóstico , Estudos Prospectivos , Radioterapia de Alta Energia , Análise de Sobrevida
6.
Eur J Cancer ; 34(3): 378-83, 1998 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-9640226

RESUMO

In approximately 5% of cancer patients undergoing radiotherapy, this treatment has to be interrupted because of an acute reaction of normal tissues. To test the possibility of predicting this type of reaction, the micronucleus assay was used to determine radiosensitivities of peripheral blood lymphocytes of 15 patients with severe acute reaction of normal tissue, 15 patients without this reaction and 15 healthy donors. Whole-blood cultures were irradiated with X-rays (4 Gy, 1.08 Gy/min) and treated with cytochalasin B. The micronuclei scores observed in irradiated cells were corrected for the scores in unirradiated cells. Intra-individual and interindividual variations in micronuclei scores were analysed in samples from healthy donors, and highly significant interindividual differences were found (P < 0.001). Scores of cells not irradiated in vitro were higher for cancer patients before radiotherapy than for healthy donors (P < 0.001), and those for cancer patients after radiotherapy were higher than for patients before radiotherapy (P < 0.001). Average micronuclei scores induced by in vitro irradiation were significantly higher in samples from cancer patients compared with those from healthy donors (P < 0.01). Moreover, all subgroups of cancer patients included individuals with very high levels of micronuclei after in vitro irradiation. There was, however, no relationship between the micronuclei scores and the occurrence of severe acute reactions in normal tissues.


Assuntos
Linfócitos/efeitos da radiação , Neoplasias/radioterapia , Lesões por Radiação/diagnóstico , Reação de Fase Aguda/etiologia , Adulto , Idoso , Feminino , Humanos , Linfócitos/patologia , Masculino , Testes para Micronúcleos/métodos , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Tolerância a Radiação
7.
Am J Physiol ; 260(3 Pt 2): F466-9, 1991 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-2000958

RESUMO

The advent of accelerator mass spectrometry (AMS) now permits the ultrasensitive detection of extremely long-lived isotopes, including 14C, 26Al, and 41Ca. Until now, tracer studies of aluminum kinetics have not been possible because aluminum has only two isotopes, with half-lives of 6.5 min (29Al) and 7 x 10(5) yr (26Al), neither of which is suitable for conventional studies. In a novel experiment we have employed AMS to study aluminum kinetics in a normal rat and a 5/6-nephrectomized rat over a 3-wk period of intravenous injection of a tracer dose of 26Al. Kinetics were similar in the two animals; approximately 75% of intravenously injected tracer 26Al was excreted in the urine in the first 24 h as was approximately 80% after 3 wk. Renal clearance of 26Al was approximately 0.75 ml.min-1.kg body wt-1 in both rats. The results clearly demonstrate the potential of this technique for isotope tracer studies in animals as well as in humans.


Assuntos
Alumínio/farmacocinética , Espectrometria de Massas , Alumínio/sangue , Alumínio/urina , Animais , Injeções Intravenosas , Rim/fisiologia , Masculino , Nefrectomia , Ratos , Ratos Endogâmicos , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA