1.
Acad Radiol ; 28(10): e314-e322, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-32654956

RESUMO

RATIONALE AND OBJECTIVES: Cone-beam CT (CBCT) applications possess potential for dose reduction in musculoskeletal imaging. This study evaluates the ultra-high-resolution CBCT prototype of a twin robotic X-ray system in wrist examinations compared to high-resolution multidetector CT (MDCT). MATERIALS AND METHODS: Sixteen wrists of body donors were examined with the CBCT scan mode and a 384 slice MDCT system. Radiation-equivalent low-dose (CTDIvol(16cm)  = 3.3 mGy) and full-dose protocols (CTDIvol(16cm)  = 13.8 mGy) were used for both systems. Two observers assessed image quality on a seven-point Likert scale. In addition, software-assisted quantification of signal intensity fractions in cancellous bone was performed. Fewer pixels with intermediate signal intensity were considered to indicate superior depiction of bone microarchitecture. RESULTS: Subjective image quality in CBCT was superior to dose equivalent MDCT with p ≤ 0.03 for full-dose and p < 0.001 for low-dose scans, respectively. Median Likert values were 7/7 (reader 1 / reader 2) in full-dose CBCT, 6/6 in full-dose MDCT, 5/6 in low-dose CBCT and 3/3 in low-dose MDCT. Intraclass correlation coefficient was 0.936 (95% confidence interval, 0.897-0.961; p < 0.001), indicating excellent reliability. Objective analysis displayed smaller fractions of "indecisive" pixels with intermediate signal intensity for full-dose CBCT (0.57 [interquartile range 0.13]) compared to full-dose MDCT (0.68 [0.21]), low-dose CBCT (0.72 [0.19]), and low-dose MDCT (0.80 [0.15]) studies. No significant difference was observed between low-dose CBCT and full-dose MDCT. CONCLUSION: The new CBCT prototype provides superior image quality for trabecula and bone marrow in cadaveric wrist studies and enables dose reduction up to 75% compared to high-resolution MDCT.


Assuntos
Procedimentos Cirúrgicos Robóticos , Punho , Cadáver , Tomografia Computadorizada de Feixe Cônico , Humanos , Radiografia , Reprodutibilidade dos Testes , Punho/diagnóstico por imagem
2.
AJR Am J Roentgenol ; 214(2): 422-427, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31799871

RESUMO

OBJECTIVE. The purpose of this study was to assess image quality and radiation dose of a novel twin robotic x-ray system's 3D cone-beam CT (CBCT) function for the depiction of cadaveric wrists. MATERIALS AND METHODS. Sixteen cadaveric wrists were scanned using dedicated low-dose and standard-dose CBCT protocols as well as clinical MDCT for comparison. Three readers assessed overall image quality, noise, and artifacts in bone and soft tissue on 5-point Likert scales. For radiation dose analysis, volume CT dose indexes (CTDIvol) were compared. RESULTS. Overall image quality of most studies was very good or excellent in MDCT (for readers 1, 2, and 3: 100%, 100%, and 88%, respectively), standard-dose CBCT (100%, 100%, and 94%), and low dose CBCT (100%, 94%, and 88%) with two readers favoring standard-dose CBCT over MDCT image quality (readers 1 and 2; p ≤ 0.046). In soft tissue, standard-dose (readers 1, 2, and 3; p ≤ 0.021) and low-dose (all p ≤ 0.001) CBCT images had more noise than MDCT in all cases. Standard-dose (all p ≤ 0.003) and low-dose (all p < 0.001) CBCT images also displayed more artifacts. In osseous tissue, one reader observed more noise (p < 0.001) and artifacts (p = 0.020) for low-dose CBCT than for MDCT, whereas no difference was found between standard-dose CBCT and MDCT. Mean CTDIvol was significantly lower for standard-dose (5.2 ± 0.6 mGy; p < 0.001) and low-dose CBCT (1.8 ± 0.2 mGy; p < 0.001) than for clinical MDCT without automatic dose modulation (15.0 ± 0.0 mGy). CONCLUSION. The tested CBCT function delivers suitable image quality for clinical wrist imaging at significantly lower radiation levels than conventional MDCT. In combination with comfortable positioning options and the ability to perform additional radiographic and fluoroscopic examinations, the twin robotic x-ray system may hold the potential to be a one-stop shop device for trauma-associated wrist imaging.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Imageamento Tridimensional/métodos , Doses de Radiação , Robótica , Articulação do Punho/diagnóstico por imagem , Artefatos , Cadáver , Humanos , Posicionamento do Paciente
3.
Eur J Radiol ; 119: 108659, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31520930

RESUMO

PURPOSE: To evaluate image quality (IQ) and radiation dose in cone-beam computed tomography (CBCT) of the ankle using a novel twin robotic X-ray system. METHOD: We examined 16 cadaveric ankles with standard-dose (FD) and low-dose (LD) protocols using the new system's CBCT mode. For comparison, we performed multi-slice CT imaging (MSCT) with a clinical protocol. Three radiologists assessed IQ, noise and artifacts in bone and soft tissue on a five-point Likert scale (1= poor IQ; strong noise or artifacts; 5= excellent IQ; minimal noise or artifacts). Volume CT dose indices (CTDIvol) were calculated for radiation dose comparison between CBCT and MSCT. RESULTS: Overall IQ was described as very good or excellent by reader 1/2/3 in 62.5/87.5/56.3% of LD, 87.5/87.5/81.3% of FD and 100/87.5/87.5% of MSCT studies. Readers agreed that IQ was better in MSCT than LD (R1/R2/R3; p ≤ 0.008), two also found advantages of MSCT over FD (R1/R3; p ≤ 0.034). Soft tissue noise and artifacts were stronger in FD (all p ≤ 0.002) and LD (all p ≤ 0.001). In bone, artifacts and noise were also more severe in LD (all p < 0.001) and FD (all p ≤ 0.003). CTDIvol for clinical MSCT scans without dose modulation (15.0 ± 0.0 mGy) were higher than for FD (5.3 ± 1.0 mGy) and LD studies (2.9 ± 0.6 mGy; both p < 0.001). CONCLUSIONS: Despite MSCT providing better overall IQ than the twin robotic X-ray system's CBCT mode, both cone-beam protocols offer very good IQ in most studies and are suitable for clinical ankle imaging. Standard-dose and especially low-dose CBCT studies deliver up to five times less radiation dose than MSCT imaging.


Assuntos
Articulação do Tornozelo/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico/normas , Doses de Radiação , Robótica/normas , Artefatos , Cadáver , Tomografia Computadorizada de Feixe Cônico/instrumentação , Tomografia Computadorizada de Feixe Cônico/métodos , Desenho de Equipamento , Humanos , Imagens de Fantasmas , Robótica/métodos , Razão Sinal-Ruído , Tomógrafos Computadorizados/normas , Raios X
4.
Mol Pharmacol ; 95(1): 82-96, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30355744

RESUMO

A domain of protein RS1 (RSC1A1) called RS1-Reg down-regulates the plasma membrane abundance of Na+-d-glucose cotransporter SGLT1 by blocking the exocytotic pathway at the trans-Golgi. This effect is blunted by intracellular glucose but prevails when serine in a QSP (Gln-Ser-Pro) motif is replaced by glutamate [RS1-Reg(S20E)]. RS1-Reg binds to ornithine decarboxylase (ODC) and inhibits ODC in a glucose-dependent manner. Because the ODC inhibitor difluoromethylornithine (DFMO) acts like RS1-Reg(S20E), and DFMO and RS1-Reg(S20E) are not cumulative, we raised the hypothesis that RS1-Reg(S20E) down-regulates the exocytotic pathway of SGLT1 at the trans-Golgi by inhibiting ODC. We investigated whether QEP down-regulates human SGLT1 (hSGLT1) like hRS1-Reg(S20E) and whether human Na+-d-glucose cotransporter hSGLT2 and the human glucose sensor hSGLT3 are also addressed. We expressed hSGLT1, hSGLT1 linked to yellow fluorescent protein (hSGLT1-YFP), hSGLT2-YFP and hSGLT3-YFP in oocytes of Xenopus laevis, injected hRS1-Reg(S20E), QEP, DFMO, and/or α-methyl-d-glucopyranoside (AMG), and measured AMG uptake, glucose-induced currents, and plasma membrane-associated fluorescence after 1 hour. We also performed in vitro AMG uptake measurements into small intestinal mucosa of mice and human. The data indicate that QEP down-regulates the exocytotic pathway of SGLT1 similar to hRS1-Reg(S20E). Our results suggests that both peptides also down-regulate hSGLT2 and hSGLT3 via the same pathway. Thirty minutes after application of 5 mM QEP in the presence of 5 mM d-glucose, hSGLT1-mediated AMG uptake into small intestinal mucosa was decreased by 40% to 50%. Thus oral application of QEP in a formulation that optimizes uptake into enterocytes but prevents entry into the blood is proposed as novel antidiabetic therapy.


Assuntos
Regulação para Baixo/fisiologia , Exocitose/fisiologia , Glucose/metabolismo , Proteínas de Transporte de Monossacarídeos/metabolismo , Peptídeos/metabolismo , Proteínas de Transporte de Sódio-Glucose/metabolismo , Adulto , Animais , Transporte Biológico/efeitos dos fármacos , Membrana Celular/efeitos dos fármacos , Membrana Celular/metabolismo , Células Cultivadas , Regulação para Baixo/efeitos dos fármacos , Eflornitina/farmacologia , Exocitose/efeitos dos fármacos , Feminino , Humanos , Mucosa Intestinal/efeitos dos fármacos , Mucosa Intestinal/metabolismo , Intestino Delgado/efeitos dos fármacos , Intestino Delgado/metabolismo , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Pessoa de Meia-Idade , Oócitos/metabolismo , Ornitina Descarboxilase/metabolismo , Xenopus laevis
SELEÇÃO DE REFERÊNCIAS