Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Anal Chem ; 93(22): 7808-7814, 2021 06 08.
Artigo em Inglês | MEDLINE | ID: mdl-34038090

RESUMO

Integration of multiomics at the single-cell level allows the unambiguous dissecting of phenotypic heterogeneity at different states such as health, disease, and biomedical response. Imaging mass spectrometry holds the promise of being able to measure multiple types of biomolecules in parallel in the same cell. We have explored the possibility of using water gas cluster ion beam secondary ion mass spectrometry [(H2O)n-GCIB-SIMS] as an analytical tool for multiomics assay. (H2O)n-GCIB has been hailed as an ideal ionization source for biological sampling owing to the enhanced chemical sensitivity and reduced matrix effect. Taking advantage of 1 µm spatial resolution by using a high-energy beam system, we have clearly shown the enhancement of multiple intact biomolecules up to a few hundredfold in single cells. Coupled with the cryogenic sample preparation/measurement, the lipids and metabolites were imaged simultaneously within the cellular region, uncovering the pristine chemistry for integrated omics in the same sample. We have demonstrated that double-charged myelin protein fragments and single-charged multiple lipids and metabolites can be localized in the same cells/tissue with a single acquisition. Our exploration has also been extended to the capability of (H2O)n-GCIB in the generation of multiple charged peptides on protein standards. Frozen hydration combined with (H2O)n-GCIB provides the possibility of universal enhancement for the ionization of multiple bio-molecules, including peptides/proteins which has allowed "omics" to become feasible in the same sample using SIMS.


Assuntos
Espectrometria de Massa de Íon Secundário , Água , Lipídeos , Fenômenos Físicos , Proteínas
2.
Anal Bioanal Chem ; 405(21): 6621-8, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23836082

RESUMO

A novel application of time-of-flight secondary ion mass spectrometry (ToF-SIMS) with continuous Ar cluster beams to peptide analysis was investigated. In order to evaluate peptide structures, it is necessary to detect fragment ions related to multiple neighbouring amino acid residues. It is, however, difficult to detect these using conventional ToF-SIMS primary ion beams such as Bi cluster beams. Recently, C60 and Ar cluster ion beams have been introduced to ToF-SIMS as primary ion beams and are expected to generate larger secondary ions than conventional ones. In this study, two sets of model peptides have been studied: (des-Tyr)-Leu-enkephalin and (des-Tyr)-Met-enkephalin (molecular weights are approximately 400 Da), and [Asn(1) Val(5)]-angiotensin II and [Val(5)]-angiotensin I (molecular weights are approximately 1,000 Da) in order to evaluate the usefulness of the large cluster ion beams for peptide structural analysis. As a result, by using the Ar cluster beams, peptide molecular ions and large fragment ions, which are not easily detected using conventional ToF-SIMS primary ion beams such as Bi3 (+), are clearly detected. Since the large fragment ions indicating amino acid sequences of the peptides are detected by the large cluster beams, it is suggested that the Ar cluster and C60 ion beams are useful for peptide structural analysis.


Assuntos
Aminoácidos/análise , Aminoácidos/química , Argônio/química , Fulerenos/química , Peptídeos/análise , Peptídeos/química , Espectrometria de Massas por Ionização por Electrospray/métodos , Sequência de Aminoácidos , Aminoácidos/efeitos da radiação , Íons Pesados , Dados de Sequência Molecular , Peptídeos/efeitos da radiação
3.
Anal Chem ; 83(10): 3793-800, 2011 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-21462969

RESUMO

Time-of-flight secondary ion mass spectrometry (TOF-SIMS) is an established technique for the characterization of solid sample surfaces. The introduction of polyatomic ion beams, such as C(60), has provided the associated ability to perform molecular depth-profiling and 3D molecular imaging. However, not all samples perform equally under C(60) bombardment, and it is probably naïve to think that there will be an ion beam that will be applicable in all situations. It is therefore important to explore the potential of other candidates. A systematic study of the suitability of argon gas cluster ion beams (Ar-GCIBs) of general composition Ar(n)(+), where n = 60-3000, as primary particles in TOF-SIMS analysis has been performed. We have assessed the potential of the Ar-GCIBs for molecular depth-profiling in terms of damage accumulation and sputter rate and also as analysis beams where spectral quality and secondary ion yields are considered. We present results with direct comparison with C(60) ions on the same sample in the same instrument on polymer, polymer additive, and biomolecular samples, including lipids and small peptides. Large argon clusters show reduced damage accumulation compared with C(60) with an approximately constant sputter rate as a function of Ar cluster size. Further, on some samples, large argon clusters produce changes in the mass spectra indicative of a more gentle ejection mechanism. However, there also appears to be a reduction in the ionization of secondary species as the size of the Ar cluster increases.


Assuntos
Argônio/química , Fulerenos/química , Lasers de Gás , Espectrometria de Massa de Íon Secundário/métodos , Angiotensina III/química , Íons/química , Espectrometria de Massa de Íon Secundário/instrumentação
4.
Anal Chem ; 82(19): 8291-9, 2010 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-20836508

RESUMO

Although the benefits of decreased sample temperature for the molecular profiling of organic materials with time-of-flight secondary ion mass spectrometry (TOF-SIMS) have been established, the mechanism behind spectral changes observed at low temperature, particularly increased protonated molecular ion (M + H)(+) yields, have not been examined in detail. We have developed a procedure to investigate these effects by monitoring secondary ion yields under sustained primary ion bombardment as the sample temperature is cooled from room temperature down to 80 K. Examination of biomaterials such as an amino acid (arginine), a polypeptide (Gly-Gly-Tyr-Arg), a lipid (1,2 dipalmitoyl-sn-glycero-3 phosphatidylcholine), and a drug molecule (cyclosporine A) each provide evidence of ion yield enhancement at 80 K under either 20 keV C(60)(+) or 20 keV Au(3)(+) bombardment. For example, arginine shows a 2-fold increase in the steady-state intensity for the (M + H)(+) ion at 80 K compared to the steady state at 300 K. It is shown that there is a correlation between the yield enhancement and a reduction in the damage cross section, which for arginine under 20 keV Au(3)(+) bombardment decreases from 5.0 ± 0.4 × 10(-14) cm(2) at 300 K to 2.0 ± 0.3 × 10(-14) cm(2) at 80 K. The role of water as the facilitator for this reduction is explored through the use of H(2)O and D(2)O dosing experiments at 80 K.


Assuntos
Espectrometria de Massa de Íon Secundário/métodos , 1,2-Dipalmitoilfosfatidilcolina/química , Arginina/química , Ciclosporina/química , Óxido de Deutério/química , Oligopeptídeos/química , Temperatura
5.
Anal Chem ; 82(15): 6652-9, 2010 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-20593800

RESUMO

An in situ freeze fracture device featuring a spring-loaded trap system has been designed and characterized for time of flight secondary ion mass spectrometry (TOF SIMS) analysis of single cells. The device employs the sandwich assembly, which is typically used in freeze fracture TOF SIMS experiments to prepare frozen, hydrated cells for high-resolution SIMS imaging. The addition of the spring-loaded trap system to the sandwich assembly offers two advances to this sample preparation method. First, mechanizing the fracture by adding a spring standardizes each fracture by removing the need to manually remove the top of the sandwich assembly with a cryogenically cooled knife. A second advance is brought about because the top of the sandwich is not discarded after the sandwich assembly has been fractured. This results in two imaging surfaces effectively doubling the sample size and providing the unique ability to image both sections of a cell bifurcated by the fracture. Here, we report TOF SIMS analysis of freeze fractured rat pheochromocytoma (PC12) cells using a Bi cluster ion source. This work exhibits the ability to obtain single cell chemical images with subcellular lateral resolution from cells preserved in an ice matrix. In addition to preserving the cells, the signal from lipid fragment ions rarely identified in single cells are better observed in the freeze-fractured samples for these experiments. Furthermore, using the accepted argument that K(+) signal indicates a cell that has been fractured though the cytoplasm, we have also identified different fracture planes of cells over the surface. Coupling a mechanized freeze fracture device to high-resolution cluster SIMS imaging will provide the sensitivity and resolution as well as the number of trials required to carry out biologically relevant SIMS experiments.


Assuntos
Técnica de Fratura por Congelamento/métodos , Espectrometria de Massa de Íon Secundário/métodos , Animais , Células PC12 , Fosfatidiletanolaminas/química , Fosforilcolina/química , Potássio/química , Ratos , Espectrometria de Massa de Íon Secundário/instrumentação
6.
Analyst ; 133(2): 175-9, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18227938

RESUMO

This communication utilises Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS) combined with multivariate analysis to obtain spectra from the surfaces of three closely related cell lines allowing their discrimination based upon mass spectral ions.


Assuntos
Neoplasias da Próstata/diagnóstico , Espectrometria de Massa de Íon Secundário/métodos , Linhagem Celular Tumoral , Análise Discriminante , Humanos , Masculino , Análise de Componente Principal/métodos
7.
Anal Chem ; 80(23): 9058-64, 2008 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-19551933

RESUMO

Time-of-flight secondary ion mass spectrometry (TOF-SIMS) has unique capabilities in the area of high-resolution mass spectrometric imaging of biological samples. The technique offers parallel detection of native and non-native molecules at physiological concentrations with potentially submicrometer spatial resolution. Recent advances in SIMS technology have been focused on generating new ion sources that can in turn be used to eject more intact molecular and biological characteristic species from a sample. The introduction of polyatomic ion beams, particularly C60, for TOF-SIMS analysis has created a whole new application of molecular depth profiling and 3D molecular imaging. However, such analyses, particularly at high lateral resolution, are severely hampered by the accompanying mass spectrometry associated with current TOF-SIMS instruments. Hence, we have developed an instrument that overcomes many of the drawbacks of current TOF-SIMS spectrometers by removing the need to pulse the primary ion beam. The instrument samples the secondary ions using a buncher that feeds into a specially designed time-of-flight analyzer. We have validated this new instrumental concept by analyzing a number of biological samples generating 2D and 3D images showing molecular localization on a subcellular scale, over a practical time frame, while maintaining high mass resolution. We also demonstrate large area mapping and the MS/MS capability of the instrument.


Assuntos
Imageamento Tridimensional/instrumentação , Mucosa Bucal/citologia , Hiperplasia Prostática/patologia , Espectrometria de Massa de Íon Secundário/instrumentação , Espectrometria de Massa de Íon Secundário/métodos , Animais , Blastômeros/citologia , Linhagem Celular Tumoral , Células Epiteliais/citologia , Desenho de Equipamento , Células HeLa , Humanos , Imageamento Tridimensional/métodos , Masculino , Xenopus/embriologia
8.
Faraday Discuss ; 126: 41-59; discussion 77-92, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-14992399

RESUMO

At present. a prognosis for prostate cancer (CaP) is determined by its accurate assessment of disease grade and stage. Histopathological typing using the Gleason grading system is the most universally accepted approach for grading CaP and provides an indication as to the aggressiveness of the tumour at the time of presentation. However, this system is based upon a visual criterion of pattern recognition that is operator dependent and subject to intra- and inter-observer variability, which can result in inappropriate patient management. Thus, there is a need for a molecular based diagnostic technique to grade tissue samples in a reliable and reproducible manner. In this paper we report a prototype diagnostic classifier for Gleason graded CaP tissue, based upon the integration of FTIR microspectroscopy with linear discriminant analysis (LDA). Blind testing of this model demonstrates 80% agreement of FTIR-LDA grade to histology, for the specimens analysed. We also study the effects of connective tissue absorption upon the area ratio of peaks at A1030 cm(-1)/A1080(cm(-1) which we use as a criterion to biospectroscopically map and distinguish areas of benign from malignant tissue. In addition, imaging time-of-flight secondary ion mass spectrometry (ToF-SIMS) has been applied to study freeze-dried, freeze-fractured prostate cancer cells in vitro. Preliminary results demonstrate localisation of various species including K, Ca and Mg within the cytoplasm that are present at millimolar concentrations and vital to cell physiology. The soft ionisation technique employed also permits for molecular information to be obtained and this has been used to evaluate chemically, different fracture planes within the analysis area.


Assuntos
Neoplasias da Próstata/patologia , Algoritmos , Linhagem Celular Tumoral , Técnica de Fratura por Congelamento , Humanos , Masculino , Espectrometria de Massas , Microscopia de Fluorescência , Espectroscopia de Infravermelho com Transformada de Fourier
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA