Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Orthop Surg Res ; 19(1): 213, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38561788

RESUMO

BACKGROUND: The application of lower limb traction during hip arthroscopy and femur fractures osteosynthesis is commonplace in orthopaedic surgeries. Traditional methods utilize a perineal post on a traction table, leading to soft tissue damage and nerve neuropraxia. A postless technique, using high-friction pads, has been considered as a potential damage-free alternative. However, whether these pads sufficiently prevent patient displacement remains unknown. Thus, this study systematically assesses the efficacy of commercial high-friction pads (PinkPad and CarePad) in restraining subject displacement, for progressively increasing traction loads and different Trendelenburg angles. METHODS: Three healthy male subjects were recruited and tested in supine and Trendelenburg positions (5° and 10°), using a customized boot-pulley system. Ten load disks (5 kg) were dropped at 15s intervals, increasing gradually the traction load up to 50 kg. Pelvis displacement along the traction direction was measured with a motion capture system. The displacement at 50 kg of traction load was analyzed and compared across various pads and bed inclinations. Response to varying traction loads was statistically assessed with a quadratic function model. RESULTS: Pelvis displacement at 50 kg traction load was below 60 mm for all conditions. Comparing PinkPad and CarePad, no significant differences in displacement were observed. Finally, similar displacements were observed for the supine and Trendelenburg positions. CONCLUSIONS: Both PinkPad and CarePad exhibited nearly linear behavior under increasing traction loads, limiting displacement to 60 mm at most for 50 kg loads. Contrary to expectations, placing subjects in the Trendelenburg position did not increase adhesion.


Assuntos
Ortopedia , Humanos , Masculino , Tração/métodos , Articulação do Quadril/cirurgia , Pelve , Fixação Interna de Fraturas
2.
Eur J Obstet Gynecol Reprod Biol ; 147(1): 25-8, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19640628

RESUMO

OBJECTIVE: This study aims to analyse changes in body sway over the course of pregnancy. STUDY DESIGN: This is a descriptive study in which stabilometric tests were applied at three stages of pregnancy and with a combination of different visual conditions (eyes open/closed) and support base configuration (feet together/apart). Twenty healthy pregnant women participated in the study. Changes in postural control with pregnancy were analysed via the elliptical area of the stabilograms and spectral analysis of the displacements of the centre of pressure (COP) along the lateral and anterior/posterior directions. RESULTS: The elliptical area encompassing the COP significantly increased over the course of the pregnancy for the feet apart and eyes closed test protocols. The spectral analysis revealed a significant increase of COP oscillations along the anterior-posterior direction when subjects stood with the eyes open/feet together and feet apart. A reduction (significant) of the lateral oscillations of COP was observed for the eyes open/feet together protocol. CONCLUSION: Pregnancy induced significant changes in the postural control when pregnant women stood with a reduced support base or with eyes closed.


Assuntos
Equilíbrio Postural/fisiologia , Postura/fisiologia , Gravidez/fisiologia , Acidentes por Quedas/prevenção & controle , Adulto , Dor nas Costas/prevenção & controle , Fenômenos Biomecânicos , Índice de Massa Corporal , Feminino , Humanos , Análise Multivariada , Propriocepção/fisiologia , Percepção Visual/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA