Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Diagnostics (Basel) ; 14(8)2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38667444

RESUMO

Abnormal uterine bleeding (AUB) poses a multifaceted challenge in women's health, necessitating an integrated approach that addresses its diverse etiologies and clinical presentations. The International Federation of Gynecology and Obstetrics PALM-COEIN classification system provides a systematic approach to the diagnosis of AUB in non-pregnant women, based on clinical and imaging-based categorization of causes into structural (Polyps, Adenomyosis, Leiomyomas and Malignancy; PALM), and non-structural causes (Coagulopathies, Ovulatory disorders, primary Endometrial disorders, Iatrogenic and Not otherwise classified; COEIN). On the other hand, placental disorders, uterine rupture, ectopic pregnancy and retained products of conceptions are the main causes of uterine bleeding during pregnancy and in the peripartum period. Ultrasound is usually the first-line imaging technique for the differential diagnosis of causes of AUB. Computed Tomography may be useful if ultrasound findings are unclear, especially in emergency settings. Magnetic resonance imaging, when indicated, is an excellent second-line diagnostic tool for a better non-invasive characterization of the underlying cause of AUB. This pictorial review aims to illustrate the main causes of AUB from the point of view of diagnostic imaging and to show not-so-common cases that can be treated by means of interventional radiology.

2.
Diagnostics (Basel) ; 11(9)2021 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-34573983

RESUMO

In women at high/intermediate lifetime risk of breast cancer (BC-LTR), contrast-enhanced magnetic resonance imaging (MRI) added to mammography ± ultrasound (MX ± US) increases sensitivity but decreases specificity. Screening with MRI alone is an alternative and potentially more cost-effective strategy. Here, we describe the study protocol and the characteristics of enrolled patients for MRIB feasibility, multicenter, randomized, controlled trial, which aims to compare MRI alone versus MX+US in women at intermediate breast cancer risk (aged 40-59, with a 15-30% BC-LTR and/or extremely dense breasts). Two screening rounds per woman were planned in ten centers experienced in MRI screening, the primary endpoint being the rate of cancers detected in the 2 arms after 5 years of follow-up. From July 2013 to November 2015, 1254 women (mean age 47 years) were enrolled: 624 were assigned to MX+US and 630 to MRI. Most of them were aged below 50 (72%) and premenopausal (45%), and 52% used oral contraceptives. Among postmenopausal women, 15% had used hormone replacement therapy. Breast and/or ovarian cancer in mothers and/or sisters were reported by 37% of enrolled women, 79% had extremely dense breasts, and 41% had a 15-30% BC-LTR. The distribution of the major determinants of breast cancer risk profiles (breast density and family history of breast and ovarian cancer) of enrolled women varied across centers.

3.
Eur J Radiol ; 143: 109926, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34438330

RESUMO

PURPOSE: Head-to-head comparison of Diffusion Weighted Imaging (DWI) and Acoustic Radiation Force Impulse (ARFI) elastography regarding the characterization of breast lesions in an assessment setting. METHOD: Patients undergoing an ultrasound examination including ARFI and an MRI protocol including DWI for the characterization of a BI-RADS 3-5 breast lesion between 06/2013 and 10/2016 were eligible for inclusion in this retrospective, IRB-approved study. 60 patients (30-84 years, median 50) with a median lesion size of 16 mm (range 5-55 mm) were included. The maximum shear wave velocity (SWVmax) and mean apparent diffusion coefficient (ADCmean) for each lesion were retrospectively evaluated by a radiologist experienced in the technique. Histology was the reference standard. Diagnostic performances of ARFI and DWI were assessed using ROC curve analysis. Spearman's rank correlation coefficient and multivariate logistic regression were used to investigate the independence of both tests regarding their diagnostic information to distinguish benign from malignant lesions. RESULTS: Corresponding areas under the ROC curve for differentiation of benign (n = 16) and malignant (n = 49) lesions were 0.822 (ARFI) and 0.871 (DWI, p-value = 0.48). SWVmax and ADCmean values showed a significant negative correlation (ρ = -0.501, p-value < 0.001). In multivariate analysis, combination of ARFI and DWI did not improve the results of each single modality, thus no significant independent diagnostic information was present. CONCLUSION: Significant correlation between quantitative findings of ARFI and DWI in breast lesions exists. Thus, ARFI provides similar diagnostic information as a DWI-including protocol of an additional "problem-solving" MRI for the characterization of a sonographically evident breast lesion, improving the immediate patient management in the assessment setting.


Assuntos
Neoplasias da Mama , Técnicas de Imagem por Elasticidade , Acústica , Mama/diagnóstico por imagem , Neoplasias da Mama/diagnóstico por imagem , Feminino , Humanos , Curva ROC , Estudos Retrospectivos , Sensibilidade e Especificidade , Ultrassonografia
5.
Tumori ; 101(3): e107-9, 2015 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-25908034

RESUMO

INTRODUCTION: Breast metastases are very uncommon, either from solid tumors or malignant melanoma. CASE REPORT: We present the case of a 42-year-old woman with a history of cutaneous melanoma of the shoulder excised 21 years ago. She presented with a palpable lump in the upper outer quadrant of the right breast. Ultrasound demonstrated a solid mass within a cystic lesion. A core biopsy was taken and first histology reported a poorly differentiated primary breast cancer suspected to be triple negative. MRI detected a satellite lesion in the same breast, a focus of suspected enhancement in the other breast, and the extramammary finding of an enhancing pulmonary lesion. Staging computed tomography detected widespread metastases to the lungs, brain, subcutaneous left shoulder, liver, pancreas, and hepatorenal recess. A core biopsy was taken from the left breast lesion and the previous slides were reviewed; histopathology and immunohistochemistry were in keeping with metastasis from melanoma. CONCLUSIONS: The possibility of a metastatic lesion to the breast should be taken into account in any patient presenting with a breast lump and a previous history of melanoma. Breast involvement cannot be considered an isolated finding, as it might be the first manifestation of widespread disease.


Assuntos
Neoplasias da Mama/diagnóstico , Neoplasias da Mama/secundário , Melanoma/diagnóstico , Melanoma/secundário , Neoplasias Cutâneas/patologia , Adulto , Biópsia com Agulha de Grande Calibre , Neoplasias Encefálicas/diagnóstico , Neoplasias Encefálicas/secundário , Feminino , Humanos , Imuno-Histoquímica , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/secundário , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/secundário , Imageamento por Ressonância Magnética , Estadiamento de Neoplasias , Neoplasias Pancreáticas/diagnóstico , Neoplasias Pancreáticas/secundário , Ombro
6.
Skeletal Radiol ; 42(1): 19-24, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22710923

RESUMO

Rotator cuff calcific tendinitis is a very common disease and may result in a very painful shoulder. Aetiology of this disease is still poorly understood. When symptoms are mild, this disease may be treated conservatively. Several treatment options have been proposed. Among them, ultrasound-guided procedures have been recently described. All procedures use one or two needles to inject a fluid, to dissolve calcium and to aspirate it. In the present article, we review some tips and tricks that may be useful to improve performance of an ultrasound-guided double-needle procedure.


Assuntos
Calcinose/diagnóstico por imagem , Calcinose/terapia , Manguito Rotador/diagnóstico por imagem , Dor de Ombro/diagnóstico por imagem , Dor de Ombro/terapia , Tendinopatia/diagnóstico por imagem , Tendinopatia/terapia , Ultrassonografia de Intervenção/métodos , Anestesia Local/métodos , Desinfecção/métodos , Humanos , Injeções Intralesionais , Agulhas , Cloreto de Sódio/administração & dosagem , Irrigação Terapêutica/métodos
9.
Int J Artif Organs ; 35(5): 346-51, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22684617

RESUMO

PURPOSE: Anemia in chronic kidney disease dialysis patients is a complex syndrome involving many causes. Adequate dialysis can contribute to its correction through many mechanisms, including the removal of molecules that may inhibit erythropoiesis. The aim of this pilot study was to evaluate the effect on renal anemia of two synthetic, high-flux dialyzers (polynephron vs. high-flux polysulphone). METHODS: 20 dialysis patients (11 male; mean age: 72 years) were randomly assigned and studied for 6 months. There were 2 dropouts in each group. Each patient underwent 3 hemodialysis treatments per week without any difference in dialysis prescription. At T = 0 and T = 6 (after 6 months), instantaneous plasma clearances and reduction rates of small solutes, ß2-microglobulin protein (ß2-µ); hemoglobin (Hb), and iron pattern were measured. The effect on anemia was evaluated by calculating the Erythropoesis Stimulating Agent (ESA) doses and the Erythropoietin Resistance Index (ERI). RESULTS: Kt/V increased between T0 and T6 in both groups. ß2-µ pre-dialysis levels significantly decreased between T0 and T6 in both dialyzer groups (p<0.001 in both groups). The Hb levels increased between T0 and T6, but significantly only for the polynephron patient group (p = 0.006 and 0.142). ESA dose did not change significantly. The ERI decreased by 22.7% between T0 and T6 in the polynephron-group and increased by 14% in the others; these changes were not significant. CONCLUSIONS: High-flux filters improved Hb levels, although only significantly in the polynephron group, suggesting a possible different effect. The results should be interpreted with caution and tested in an appropriately powered, large, prospective, randomized control trial.


Assuntos
Anemia/tratamento farmacológico , Hematínicos/administração & dosagem , Nefropatias/terapia , Membranas Artificiais , Diálise Renal/instrumentação , Idoso , Idoso de 80 Anos ou mais , Anemia/sangue , Anemia/etiologia , Biomarcadores/sangue , Desenho de Equipamento , Feminino , Hemoglobinas/metabolismo , Humanos , Itália , Nefropatias/sangue , Nefropatias/complicações , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Polímeros , Estudos Prospectivos , Diálise Renal/efeitos adversos , Sulfonas , Fatores de Tempo , Resultado do Tratamento
10.
J Comput Assist Tomogr ; 36(3): 301-5, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22592612

RESUMO

OBJECTIVE: This study aimed to estimate the frequency and timing of washout in a series of pathologically proven benign mass-like breast lesions at dynamic magnetic resonance imaging. METHODS: Institutional review board approval was obtained for this retrospective study. We evaluated enhancement kinetics of 33 pathologically confirmed benign breast lesions: fibroadenomas (n = 22), adenosis (n = 6), typical ductal hyperplasia (n = 2), fibroadenoma with ductal hyperplasia (n = 1), fibrosclerosis (n = 1), and inflammatory lesion (n = 1). Coronal 3-dimensional T1-weighted gradient-echo sequences were acquired before/after intravenous injection of 0.1 mmol/ kg gadoterate meglumine (time resolution, 111 seconds), 1 before and 5 after contrast injection. The time point at which the kinetic curve demonstrated a washout was recorded. Cumulative distribution of lesions showing washout was built. Paired comparisons of specificity for washout kinetics were performed using the McNemar test. RESULTS: Of 33 lesions, washout was never observed in 20 (61%), whereas 13 (39%) showed washout during the study. Of these 13 lesions, only 1 (inflammatory mass) exhibited washout within the first 3 minutes (specificity, 97%), 9 within 6 minutes (specificity, 73%), and 13 within 8 minutes (specificity, 61%). Specificity of washout kinetics within 3 minutes (97%) was significantly larger than that from the sixth minute (73%) and thereafter (P < 0.016). CONCLUSIONS: A prolonged observation for dynamic breast magnetic resonance imaging may result in false-positive washout, especially after 6 minutes. Late washout should not be considered a reliable marker of malignancy.


Assuntos
Doenças Mamárias/diagnóstico , Meios de Contraste/farmacocinética , Imageamento por Ressonância Magnética/métodos , Meglumina/farmacocinética , Compostos Organometálicos/farmacocinética , Adulto , Mama/patologia , Neoplasias da Mama/diagnóstico , Diagnóstico Diferencial , Feminino , Fibroadenoma/diagnóstico , Doença da Mama Fibrocística/diagnóstico , Humanos , Hiperplasia/diagnóstico , Aumento da Imagem/métodos , Imageamento Tridimensional/métodos , Neoplasias Inflamatórias Mamárias/diagnóstico , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA