Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Orthop J Sports Med ; 12(2): 23259671231226326, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38322980

RESUMO

Background: As information on the meniscus accumulates in PubMed, it is possible to evaluate the trends in research on the topic over time. Purpose: To evaluate the major trends in meniscus-related publications in PubMed from the earliest publication to the present day. Study Design: Cross-sectional study. Methods: PubMed was searched on January 3, 2023, using the search strategy "menisc *"[All Fields] AND ("knee"[MeSH Terms] OR "knee"[All Fields] OR "knee joint"[MeSH Terms] OR ("knee"[All Fields] AND "joint"[All Fields]) OR "knee joint"[All Fields]) AND 1900/01/01:2022/12/31[Date - Publication]. This retrieved 15,569 human and animal studies. We determined the top 10 meniscus-related publications in terms of overall citations and citations per year, as well as the top 10 authors, journals, countries, and institutions of cited publications on the meniscus. In addition, we performed word-cloud analyses based on meniscus-related terms from different periods (before 1981, before 2000, after 2005, and in the past 5 years [2018-2022]), including the year of first appearance and the number of publications featured. Results: Since the first recorded publication on the meniscus in 1928, there was a steady growth in the number of articles until 2005, when there was an upsurge in publications from 254 in 2005 to 955 in 2022. Noyes was the author with the most citations (n = 3314), and a 2006 study by Caplan and Dennis had the most citations per year (n = 125). Arthroscopy published the most articles on the meniscus with 1118, whereas the Journal of Cellular Biochemistry had the most citations per article with 125.69. The most published countries and institutes were the United States and the Hospital for Special Surgery, respectively. Word-cloud analysis of article titles showed that "meniscectomy" had become less prominent, and "root,""ramp,""transplantation," and "slope" had become more prominent. Conclusion: There has been an upsurge in publications on the meniscus since 2005, with word-cloud analysis indicating shifting interests in meniscus-related research.

2.
J Orthop ; 46: 24-50, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37942220

RESUMO

Introduction: Since previous studies, including small-scale meta-analyses comparing accelerometer-based portable navigation (APN-TKA) and conventional techniqueof total knee arthroplasty (CONV-TKA), have reported divergent results, there is a need for an updated meta-analysis to compare complications, functional outcomes, clinically relevant outcomes and radiographic alignment of components. Methods: This meta-analysis was conducted as per PRISMA guidelines. Randomised controlled trials, and non-randomised comparative cohort studies in English language on primary TKA were included. The complications compared were Deep Vein Thrombosis (DVT), Pulmonary Embolism (PE), infection, manipulation under anaesthesia (MUA) for postoperative knee stiffness, re-operation and mortality. The functional outcomes compared were the Knee Society Knee Score, Knee Society Score function, Oxford Knee Score, Knee Injury and Osteoarthritis Outcome Score and Western Ontario and McMaster Universities Arthritis Index. The evaluated clinically relevant outcomes were surgical time, blood loss, drop in haematocrit, tourniquet time, postoperative knee flexion and complications). The number of radiological outliers; as well as the absolute values of the alignment of the overall prosthesis, femoral and tibial components in both coronal and sagittal planes, was assessed. Results: Twenty-five studies were included. Both the groups were comparable in terms of preoperative demographic features. There was no difference in complications and functional outcomes. Operation time was longer in APN-TKA (p < 0.00001) but there was no difference in rest of the clinically relevant outcomes. Restoration of the lower limb mechanical axis (p = 0.003) and coronal femoral alignment angle (p = 0.0002) was better with APN. APN also significantly reduced the risk of the odds of outliers of lower limb mechanical axis (p < 0.0001), coronal femoral alignment (p = 0.03), coronal tibial alignment (p < 0.0001) and sagittal tibial alignment (p = 0.0001). Conclusion: The improvement in the accuracy of implantation by the use of APN-TKA, as determined by the overall alignments of prosthesis, or femoral and tibial components, does not necessarily translate into lesser complications and better functional and clinical outcomes. Level of evidence: Therapeutic study, Level II.

3.
Indian J Orthop ; 57(10): 1623-1632, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37766958

RESUMO

Purpose: To improve the clinical outcomes of anterior cruciate ligament reconstruction (ACLR), there have been attempts to reproduce anatomic reconstruction by modifying the single-bundle (SB) and double-bundle (DB) techniques. Although DB ACLR restores better rotational control compared to SB ACLR, it is still debatable whether there are higher clinical outcomes in favor of DB ACLR. We aimed to study the trends of publications on SB and DB ACLR techniques over the last 20 years. Methods: For this bibliometric study, we performed a PubMed search on 31/05/2022 with a well-defined search strategy. The articles were downloaded into Excel software, and citations were determined from the iCite website for PubMed. The analysis was performed using SPSS software version 28.0.1. Data mining was performed using Orange software, Mac version 3.32.0, from the titles of all articles and each group of SB and DB ACLR. The output is presented as word clouds. Results: A total of 10,530 publications were identified, of which 9699 publications (92.1%) pertained to SB-ACLR and 831 publications (7.9%) to DB-ACLR. There was a steady increase in the publications on SB-ACLR until 2012, followed by a steep increase that peaked in 2021. The highest number of publications on DB-ACLR was in 2012 (n = 76; 9.1%). The mean citations per year for SB-ACLR and DB-ACLR were 2.87 ± 4.31 and 2.74 ± 3.17, respectively. The most prolific journals publishing on this topic were Knee Surgery Sports Traumatology Arthroscopy, American Journal of Sports Medicine, and Arthroscopy. The top three articles that received the maximum number of citations were from Japanese authors. Conclusion: The number of publications related to SB-ACLR was significantly higher than that related to DB-ACLR in the last 20 years. The publications related to DB-ACLR have decreased in the recent past, after reaching a peak in 2012. The citations per year of SB-ACLR and DB-ACLR were similar.

4.
Int Orthop ; 47(8): 1947-1961, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37020032

RESUMO

PURPOSE: This meta-analysis aims to compare the early postoperative recovery, complications encountered, length of hospital stay, and initial functional scores between patellar eversion and non-eversion manoeuvres in patients undergoing during primary total knee arthroplasty (TKA) based on clinical studies available in the literature. METHODS: A systematic literature search was conducted using PubMed, Embase, Web of Science, and the Cochrane Library databases between January 1, 2000 and August 12, 2022. Prospective trials comparing clinical, radiological, and functional outcomes in patients undergoing TKA with and without patellar eversion manoeuvre were included. The meta-analysis was performed using Rev-Man version 5.41 (Cochrane Collaboration). Pooled-odds ratios (for categorical data) and mean differences with 95% confidence intervals (for continuous data) were calculated (p < 0.05 was regarded as statistically significant). RESULTS: Ten (out of the 298 publications identified in this subject) were included for the meta-analysis. The patellar eversion group (PEG) had a significantly shorter tourniquet time [mean difference (MD) - 8.91 min; p = 0.002], although the overall intraoperative blood loss was higher (IOBL; MD 93.02 ml; p = 0.0003). The patellar retraction group (PRG), on the other hand, revealed statistically better early clinical outcomes in terms of shorter time necessary to perform active straight leg raising (MD 0.66, p = 0.0001), shorter time to achieve 90° knee-flexion (MD 0.29, p = 0.03), higher degree of knee flexion achieved at 90 days (MD - 1.90, p = 0.03), and reduced length of hospital stay (MD 0.65, p = 0.03). There was no statistically significant difference in the early complication rates, 36-item short-form health survey (1 year), visual analogue scores (1 year), and Insall-Salvati index at follow-up between the groups. CONCLUSION: The implications from the evaluated studies suggest that in comparison with patellar eversion, patellar retraction manoeuvre during surgery provides significantly faster recovery of quadriceps function, earlier attainment of functional knee range of motion (ROM), and shorter length of hospital stay in patients undergoing TKA.


Assuntos
Artroplastia do Joelho , Humanos , Artroplastia do Joelho/efeitos adversos , Estudos Prospectivos , Articulação do Joelho/cirurgia , Patela/cirurgia , Músculo Quadríceps/cirurgia , Amplitude de Movimento Articular
5.
Artigo em Inglês | MEDLINE | ID: mdl-36767293

RESUMO

Assessment of work-related musculoskeletal disorders (WMSDs) using the Rapid Upper Limb Assessment (RULA) and the Nordic Musculoskeletal Questionnaire (NMQ) has become widely accepted and reported in the literature. The objectives of this study are to (1) recognize and describe the topmost 50 cited scientific articles in WMSDs using the RULA and NMQ and (2) explore the factors that contribute to making an article influential. In this bibliometric study, we used the Web of Science and MEDLINE databases to identify the top 50 cited articles published from 1993 to 2022. The data collected were the title of the journal, number of citations, year of publication, type of the study, institution where the work was conducted, level of evidence, contribution of primary authors, and country of origin of the work. Our results showed that the top 50 cited articles were published between 1980 and 2010. The 2000s was the most valuable decade. Regarding journals, the Work journal had the highest number of articles concerning the use of RULA and NMQ in healthcare professionals. The maximum number of citations regarding RULA occurred in the Journal of Robotic Surgery (n = 50) and the maximum for NMQ occurred in the Journal of Safety Research (n = 106). Most articles originated from the United States, followed by England and the Netherlands. Eight authors had two publications published in the top 50 list. The majority of the topmost cited research articles were cross-sectional studies. Most of these studies were level III evidence. The bibliometric analysis from this study provides insights to researchers to choose the most appropriate and influential journal for submitting work on WMSDs.


Assuntos
Bibliometria , Extremidade Superior , Estados Unidos , Humanos , Bases de Dados Factuais , Inglaterra , Gerenciamento de Dados
6.
J Orthop ; 34: 14-20, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35992612

RESUMO

Introduction and aims: There is paucity of prospective studies on conversion total hip arthroplasty (CTHA) for failed proximal femoral nailing. The objective of this study is to evaluate the functional outcome of CTHA using extensively porous coated distal loading stem for failed proximal femoral nailing. Patients and methods: Fifteen consecutively operated patients for failed proximal femoral nail treated with single stage procedure of nail extraction and CTHA were included in this prospective observational study. All patients received metal-on-polyethylene bearing with uncemented press-fit acetabular cup (Pinnacle cup; DePuy, Warsaw [IN], USA) and extensively porous coated distally loading revision stem (Solution stem; DePuy, Warsaw [IN], USA). All patients were assessed preoperatively and postoperatively at one, three, six and more than twelve months using the Harris Hip Score (HHS). The responsiveness of HHS was assessed using Effect Size (ES) and Standardised Response Mean (SRM). ES and SRM >0.8 indicates adequate responsiveness. Results: The mean duration of follow-up was 16.9 months for the overall cohort (SD: 7.9; range: 6-28 months). The mean preoperative HHS was 32 ± 6.1, the mean HHS at six months follow-up was 89.7 ± 4.0 and the mean HHS at final follow-up of atleast one year was 93.7 ± 3.0. There was a statistically and clinically significant improvement in the HHS from preoperatively to final follow-up postoperatively (p < 0.0001). At the final follow-up, twelve patients (80%) had an excellent outcome and three patients (20%) had a good outcome as per HHS grading. The ES was 9.87 and the SRM was 8.86 thereby suggesting adequate responsiveness. One patient developed surgical site infection and another patient developed dislocation. Both were successfully treated and subsequently the patients made uneventful recovery. None of the patients required revision surgery. Conclusion: HHS has adequate responsiveness for assessing the functional outcome of CTHA. We recommend the use of an uncemented cup and uncemented extensively porous coated, distal loading stem for failed PFN fixation in intertrochanteric hip fractures.

7.
Knee Surg Sports Traumatol Arthrosc ; 30(9): 3076-3091, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35013748

RESUMO

PURPOSE: No systematic review has compared the clinical outcome of anterior stabilized ultra-congruent and standard cruciate-retaining inserts in fixed-bearing primary total knee arthroplasty. This study aimed to compare the outcomes and establish the superiority or equivalence of these inserts. METHODS: Pubmed, EMBASE, Medline, AMED, ERIC, and Proquest databases were searched electronically. PRISMA guidelines were followed in the conduct of the study. The clinical outcomes compared in the meta-analysis were overall knee score, WOMAC, score for knee function, score for knee pain, SF-12 PCS, knee flexion, manipulation under anaesthesia for postoperative knee stiffness, revision total knee arthroplasty or change of polyethylene insert for post-operative instability (relative risk [RR]) and survivorship. Study quality was evaluated using the Newcastle Ottawa Scale and the Modified Jadad scale. RESULTS: Fourteen studies comprising 9989 knees (three RCTs and 11 comparative case-cohort studies) were included for qualitative and quantitative analysis. The pooled analysis of the ultracongruent insert and the standard cruciate retaining insert was based on a cohort of 2860 and 7129 TKA, respectively. Knee pain was significantly better in patients that had standard inserts (p = 0.02; 95% CI - 1.06 to - 0.10), and the physical component of health-related quality of life was also significantly better in patients that had standard inserts (p = 0.02; 95% CI - 6.43 to - 0.64). There was a 72% lesser chance of revision TKA or change of insert for postoperative instability in knees that had been implanted with ultracongruent inserts (RR = 0.28; p = 0.0002; 95% CI 0.15-0.55). There was no difference in the otheroutcome measures. There was no significant difference between the two inserts, considering the minimal clinically important difference or absolute ratio. CONCLUSION: Differences observed between the two types of inserts were not clinically significant. Therefore, based on current evidence, arthroplasty surgeons can use either of these inserts with cruciate-retaining knee prosthesis. LEVEL OF EVIDENCE: Therapeutic study, Level II.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Ligamento Cruzado Posterior , Humanos , Articulação do Joelho , Dor , Desenho de Prótese , Qualidade de Vida , Amplitude de Movimento Articular
8.
Acta Orthop Belg ; 87(2): 305-311, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34529385

RESUMO

There is no study that has compared the radiation exposure during short (Short PFN) and long proximal femoral nailing (Long PFN) for 31A2 intertrochanteric hip fractures. The objective of the present study was to compare the radiation exposure time in short and long proximal femoral nail during the treatment of 31A2 intertrochanteric hip fractures. This prospective cohort study was carried out in a University teaching hospital. Sixty one consecutive patients with 31A2 intertrochanteric femur fracture treated with proximal femoral nail were included in the study. The distal locking in the short PFN was performed using the locking zig and distal locking in the long PFN was performed using the free hand perfect circle technique. The same mobile image intensifier (Multimobil 5E, Siemens, Erlangen, Germany) was used in the entire study. The outcome measure was the fluoroscopy exposure time (seconds) which was measured directly from the image intensifier. Thirty patients underwent fixation with short PFN and 31 patients underwent fixation using long PFN. The mean fluoroscopy exposure time in short PFN cohort was 189.5 seconds ± 26 (range : 150-250 seconds) and the mean fluoroscopy exposure time in long PFN cohort was 283.4 seconds ± 43.8 (range : 200-400 seconds). The mean fluoroscopy exposure time was 93.9 seconds shorter in the short PFN cohort and this difference was statistically significant (p & 0.0001 ; 95% CI : 75.4 to 112.3). The radiation exposure to the operating team is significantly less during treatment with short PFN in 31A2 intertrochanteric fractures.


Assuntos
Fixação Intramedular de Fraturas , Fraturas do Quadril , Pinos Ortopédicos , Fluoroscopia , Fraturas do Quadril/diagnóstico por imagem , Fraturas do Quadril/cirurgia , Humanos , Estudos Prospectivos , Resultado do Tratamento
9.
J Clin Orthop Trauma ; 21: 101505, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34367911

RESUMO

As we step into a technology powered era, where information is available everywhere, managing data forms an important part of professional and everyday life. With developments like online databases, high definition videos and images, social media, robotics, explosion of academic publications, telecommunication, artificial intelligence and internet of things, there is a variable amount of data that the orthopaedic surgeon is exposed to and has to deal with on a regular basis. It is imperative that the surgeon has a basic working knowledge on data and its applications in relation to the field of orthopaedic surgery. This review introduces the surgeon to data and its types, its sources, collection, Electronic Medical Records (EMR), management after collection, Big data and legal issues related to data. Data generators from megabytes to yottabytes are discussed along with options for their storage and analysis. Knowledge on the types of data is important to decide on the type of statistical tests that may be used on them, for the options available for storage, analysis and legal issues. We discuss the different types of data, computer and cloud-based systems of Electronic Medical Records (EMRs) with their advantages and disadvantages as well as the differences between conventional and EMRs. Management of data after collection is discussed including storage and backup, archiving and sharing, organizing, tracking changes and analysis. High resolution images, videos, robotics and analytics are powering demand and production of data in Trauma and Orthopaedics. Issues like copyright, Privacy, security, encryption and legal issues related to data are highlighted as these are important as more and more data is being used online and involve issues of privacy and security. We also take a look into the future of data in orthopaedics as digitization of the world is occurring at a rapid pace.

10.
Eur J Orthop Surg Traumatol ; 29(6): 1199-1204, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30955091

RESUMO

INTRODUCTION: There is a paucity of studies reporting responsiveness of visual analogue scale (VAS) measures in patients treated by discectomy for symptomatic lumbar disc herniation. The aim of this study was to evaluate the responsiveness of different types of VAS. METHODS: VAS score was measured separately for constant leg pain (VAS-LP-constant), severe episode of leg pain (VAS-LP-severe), constant backache (VAS-BP-constant) and severe episode of backache (VAS-BP-severe) in a cohort of patients undergoing discectomy surgery for sciatica. VAS was evaluated preoperatively and postoperatively at final follow-up. Responsiveness was determined using standardised response mean (SRM), effect size (ES) and the area under the curve (AUC) analysis using receiver operating characteristic curves. For AUC analysis, the success of discectomy from the patient's perspective was chosen as the external anchor. RESULTS: Ninety-eight patients were included in this prospective study. Outcome was assessed at a mean follow-up of 12 weeks postoperatively. The SRM of VAS-LP-severe, VAS-LP-constant, VAS-BP-severe and VAS-BP-constant was 2.16, 2.16, 0.87 and 0.53, respectively. The ES of VAS-LP-severe, VAS-LP-constant, VAS-BP-severe and VAS-BP-constant was 3.53, 2.70, 0.89 and 0.53, respectively. The AUC of VAS-LP-severe, VAS-LP-constant, VAS-BP-severe and VAS-BP-constant was 0.88, 0.75, 0.74 and 0.59, respectively. CONCLUSION: We recommend the use of VAS-LP-Severe as the most responsive VAS measure when evaluating the results of discectomy surgery for sciatica.


Assuntos
Discotomia , Degeneração do Disco Intervertebral/complicações , Deslocamento do Disco Intervertebral/complicações , Complicações Pós-Operatórias/diagnóstico , Ciática , Escala Visual Analógica , Assistência ao Convalescente/métodos , Discotomia/efeitos adversos , Discotomia/métodos , Feminino , Humanos , Degeneração do Disco Intervertebral/cirurgia , Deslocamento do Disco Intervertebral/cirurgia , Vértebras Lombares/cirurgia , Masculino , Pessoa de Meia-Idade , Medição da Dor/métodos , Seleção de Pacientes , Assistência Perioperatória/métodos , Ciática/diagnóstico , Ciática/etiologia , Resultado do Tratamento
11.
Indian J Med Ethics ; 2(1): 45-48, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-27866145

RESUMO

Recently, a 23-year-old male patient underwent cosmetic limb lengthening, despite the fact that his height was that of the average Indian male (5 feet 7 inches). The patient's parents and the media criticised the orthopaedic surgeon who had performed the surgery for undertaking an unethical operation. This paper discusses the relevant clinical evidence, ethical aspects and ethical theories surrounding the case. We conclude that the surgeon's decision to perform the surgery seems to be fair and appropriate from the ethical and clinical perspectives.


Assuntos
Estatura , Alongamento Ósseo/ética , Ética Médica , Adulto , Análise Ética , Humanos , Consentimento Livre e Esclarecido , Masculino , Satisfação do Paciente , Autonomia Pessoal , Valores de Referência
12.
J Shoulder Elbow Surg ; 22(3): 312-7, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23312819

RESUMO

BACKGROUND: Responsiveness and floor and ceiling effect are important parameters for evaluating the sensitivity of an outcome instrument in detecting the changes in the clinical condition of patients after an intervention as well as evaluating the content validity of the instrument. The aim of this prospective observational study was to assess these parameters for the Liverpool Elbow Score (LES) in total elbow replacement (TER). METHODS: The study included 121 cemented TER cases with linked elbow prosthesis (Discovery Elbow, Biomet Orthopaedics, Swindon, UK) for various conditions, including inflammatory arthritis, noninflammatory arthritis, trauma, and loosening. The proportion of patients with the lowest score (0 points; floor effect) and maximum score (10 points; ceiling effect) was checked preoperatively and 1 year postoperatively. Distribution-based methods (effect size [ES], standardized response mean [SRM], Guyatt responsiveness ratio [GRR]) and anchor-based methods (receiver operating characteristic [ROC] curve and Spearman correlation coefficient) were used to assess responsiveness. Patient satisfaction after TER was used as an external anchor. RESULTS: Patients were a mean age of 63 years (range, 20-86 years). Large ES (1.64), SRM (1.25), and GRR (1.69) were found during the follow-up period. Area under the ROC curve was 0.71 (95% confidence interval, 0.56-0.87; P = .03). There was significant positive correlation (Spearman correlation coefficient, 0.35; P = .004) between changes in LES and satisfaction level. LES showed no floor and ceiling effect preoperatively and at 1 year postoperatively. CONCLUSION: LES is a responsive measure and has no floor and ceiling effect. LEVEL OF EVIDENCE: This encourages its use as an outcome instrument for TER. Basic Science Study, Development or Validation of Outcome Instruments.


Assuntos
Artroplastia de Substituição do Cotovelo , Articulação do Cotovelo/cirurgia , Indicadores Básicos de Saúde , Artropatias/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade , Resultado do Tratamento , Adulto Jovem , Lesões no Cotovelo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA