Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 77
Filtrar
1.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1528861

RESUMO

This case report aimed to describe the importance of endodontic treatment in reducing infectious foci in patients with Eisenmenger syndrome (ES) and describe the characteristics of ES, so that the endodontist can safely treat these patients. A 57-year-old male with ES sought dental care complaining of dental pain. Irreversible pulpitis was diagnosed in tooth 37 and pulp necrosis in teeth 36, 34 and 31. Tests of prothrombin time (PT), activated partial thromboblastin time (APTT) and international normalized ratio (INR) were prescribed to evaluate the profile of coagulation using Marevan and antibiotic prophylaxis with amoxicillin. The endodontic treatments were performed. At the end, the patient reported no pain or discomfort in the teeth and improved masticatory function. The removal of oral infectious foci in patients with ES is important to reduce the risk of IE, which could seriously compromise the health and overall prognosis of the patient.


Este reporte de caso tuvo como objetivo describir la importancia del tratamiento endodóntico en la reducción de focos infecciosos en pacientes con síndrome de Eisenmenger (SE) y describir las características del SE, para que el endodoncista pueda tratar con seguridad a estos pacientes. Un hombre de 57 años con ES buscó atención dental quejándose de dolor dental. Se diagnosticó pulpitis irreversible en el diente 37 y necrosis pulpar en los dientes 36, 34 y 31. Se solicitaron pruebas de tiempo de protrombina (PT), tiempo de tromboblastina parcial activada (TTPA) y índice internacional normalizado (INR) para evaluar el perfil de coagulación utilizando Marevan y profilaxis antibiótica con amoxicilina. Se realizaron los tratamientos de endodoncia. Al final, el paciente no refirió dolor ni molestias en los dientes y mejoró la función masticatoria. La eliminación de focos infecciosos orales en pacientes con ES es importante para reducir el riesgo de EI, que podría comprometer gravemente la salud y el pronóstico general del paciente.

2.
Clin Oral Investig ; 28(1): 10, 2023 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-38127289

RESUMO

OBJECTIVES: The study aimed to evaluate the potential for the dissolution of organic tissue in areas of simulated complexity and cleaning of root canal walls of the new iVac® endodontic irrigation system. MATERIAL AND METHODS: Thirty mandibular premolars were evaluated by scanning electron microscopy before and after biomechanical preparation. Then, they were distributed according to the final irrigation protocol into groups with conventional irrigation, ultrasonic agitation with metallic insert (UA), and iVac® system, and new photomicrographs were obtained. For tissue dissolution analysis, glass capillaries filled with catgut were attached to the cervical and apical thirds of twenty-one prototyped upper incisors. They were weighed before and after the previously mentioned irrigation protocols. The data were statistically compared with a significance level of 5%. RESULTS: The final irrigation provided greater cleaning of the root canal walls in the cervical, middle, and apical thirds of the root canals (P < 0.05), with no statistically significant difference between UA and iVac®, regardless of the analyzed thirds. Both ultrasonic irrigation protocols dissolved a significantly greater volume than the conventional irrigation protocol (P < 0.05), with no difference between the two protocols (P < 0.05). CONCLUSIONS: The iVac® system showed root canal wall cleaning and tissue dissolution similar to UA with a metallic insert, and both were superior to conventional irrigation. CLINICAL RELEVANCE: The new irrigation system iVac is more effective than conventional irrigation and has similar root canal wall cleaning and tissue dissolution to UA.


Assuntos
Camada de Esfregaço , Humanos , Vidro , Incisivo , Microscopia Eletrônica de Varredura , Pescoço
3.
J. res. dent ; 11(2): 25-31, Oct 2023.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1513036

RESUMO

Aims: The aim was to evaluate the cyclic and torsional fatigue resistance among thermally treated NiTi rotary instruments with different design features.Materials and methods: Sixty instruments of three systems were used (n=20): TruNatomy 26.04 (TN 26.04), BassiLogic 25.05 (BL 25.05), and Flat File 25.04 (FF 25.04). The cyclic fatigue test (n=10) was performed to evaluate the time to fracture (s) and the number of cycles until failure (NCF). The torsion test was performed to evaluate the torque (N.cm) and maximum angular deflection until fracture (n=10). The fracture surface of each fragment was examined under a scanning electron microscope. The data were analyzed by Tukey's test (p<0.05).Results: BL 25.05 and FF 25.04 instruments had a higher number of cycles and time to fracture compared with TN 26.04 (p<0.05). TN 26.04 instruments showed lower torque to fracture.Conclusions: Based on the proposed objectives and the methodology used, TruNatomy 26.04 instruments present lower resistance to cyclic fatigue and torsional fatigue when compared to BassiLogic 25.05 and Flat File 25.04 instruments.

4.
Aust Endod J ; 49(3): 524-529, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37439395

RESUMO

This study investigated the cyclic fatigue and torsional resistance of Unicone Plus (UCP 25.06), Unicone (UC 25.06), Reciproc Blue (RB 25.08) and Wave One Gold (WOG 25.07) performed at body temperature (35° ± 1°C). Time and number of cycles to fracture (NCF), as well as torque and angular deflection were recorded. Fractured surfaces were evaluated by scanning electron microscopy (SEM). Data were analysed using one-way ANOVA and Holm-Sidak's tests for multiple comparison. The RB had a significantly higher time to fracture, followed by the WOG and UCP (p < 0.05). Regarding the NCF, there was no significantly difference between RB and WOG (p > 0.05). UC presented highest torque values and the lowest angular deflection (p < 0.05). SEM analysis demonstrated typical failures features in both cyclic and torsional fatigue tests. Overall, UC had the lowest time, NCF and angular deflection at fracture. RB presented the highest time to fracture and angular deflection values.


Assuntos
Ligas Dentárias , Temperatura Alta , Estresse Mecânico , Titânio , Níquel , Instrumentos Odontológicos , Desenho de Equipamento , Preparo de Canal Radicular , Teste de Materiais
5.
Braz. dent. j ; 34(1): 12-18, Jan.-Feb. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO | ID: biblio-1420578

RESUMO

Abstract This study aimed to evaluate the influence of temperature on torsional strength and angular deflection of two experimental NiTi rotary instruments manufactured from Blue and Gold thermal treatments and with identical cross-sections. A total of 40 experimental NiTi instruments 25.06 and with a triangular cross-section and manufactured from Blue and Gold thermal treatments were used (n=20). The torsional test was performed in the 3 mm from the tip of the instrument according to ISO 3630-1. The torsional test evaluated the torsional strength and angular deflection to failure at room temperature (21°C ± 1° C) and body temperature (36°C ±1°C). The fractured surface of each fragment was observed by using scanning electron microscopy (SEM). Data were analyzed using an unpaired t test for inter and intra-group comparison and the level of significance was set at 5%. The results showed that the body temperature did not affect the torsional strength and angular deflection of the instruments when compared with room temperature (P>0.05). However, at body temperature, the Blue NiTi instruments presented significantly lower angular deflection in comparison with Gold NiTi instruments (P<0.05). There was no significant difference regarding the torsional strength of the instruments at body temperature (P>0.05). The temperature did not affect the torsional strength of the instruments manufactured from Blue and Gold technology. However, the Blue NiTi instruments presented significantly lower angular deflection than Gold instruments at 36°C temperature.


Resumo O objetivo deste estudo foi avaliar a influência da temperatura nas propriedades de torção (resistência à torção e deflexão angular) de dois instrumentos rotatórios experimentais de NiTi fabricados com secção triangu.ar e tratamentos térmicos Blue e Gold. Quarenta instrumentos experimentais de NiTi 25.06 com tratamento térmico Blue e Gold foram usados (n= 20). Foi avaliada a resistência torcional e a deflexão angular até a fratura na temperatura ambiente (21°C ± 1°C) e corporal (36°C ± 1°C). O teste torcional foi realizado nos 3 mm da ponta dos instrumentos de acordo com a ISO 3630-1. A superfície fraturada de cada instrumento foi observada pelo microscópio eletrônico de varredura (MEV). Os dados foram analisados por meio do teste t não pareado para a comparação inter e intragrupos e o nível de significância à 5%. Os resultados demonstraram que a temperatura corporal não afetou a resistência a torção e deflexão angular quando comparada com a temperatura ambiente (P>0.05). No entanto, na temperatura de 36°C o instrumento com tratamento térmico Blue apresentou menor deflexão angular quando comparado com o Gold (P<0.05). Não houve diferença significante entre os dois instrumentos em relação a resistência à torção. A temperatura corporal não modificou a resistência torcional dos instrumentos fabricados com tecnologia Blue e Gold. No entanto, os instrumentos com NiTi Blue apresentaram menor deflexão angular do que o Gold a 36°C.

6.
Aust Endod J ; 49 Suppl 1: 18-26, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36093994

RESUMO

The aim of this study was to evaluate the maximum penetration depth (MPD) and penetration area (PA) of CaOH2 paste agitated by different methods and to measure the pH after performing these methods. Fifty-five mandibular premolars were divided into control, GL and 4 experimental groups, GEC, GXP, GEDDY and GI (n = 11), where the paste was agitated with Easy Clean, XP-endo Finisher, EDDY and Irrisonic, respectively. The canals were instrumented and irrigated with NaOCl. The paste was manipulated with propylene glycol and rhodamine B dye. Root sections were examined using confocal laser scanning microscopy. There was no difference between groups regarding PA (p > 0.05). At 5 mm, MPD was greater in GEC than in GL or GEDDY, and greater in GI than in GL (p < 0.05). At 2 mm, MPD was greater in GEC than in the other groups (p < 0.05). In conclusion, both Easy Clean and Irrisonic promoted deeper paste penetration and were associated with higher pH levels.


Assuntos
Propilenoglicol , Irrigantes do Canal Radicular , Irrigantes do Canal Radicular/farmacologia , Microscopia Confocal , Dente Pré-Molar , Cavidade Pulpar , Preparo de Canal Radicular/métodos
7.
J. appl. oral sci ; 31: e20230222, 2023. tab
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1514410

RESUMO

Abstract This study aimed to assess the self-reported levels of confidence and knowledge related to non-odontogenic pain among a group of Brazilian endodontists. Methodology A total of one hundred and forty-six endodontists affiliated with the Brazilian Society of Endodontics participated in the survey. The questionnaire, distributed via email or WhatsApp, contained inquiries designed to gauge self-perceived confidence and knowledge concerning non-odontogenic pain. The practitioners were categorized into four groups based on their self-reported familiarity with various orofacial pain types, classified as either sufficient or insufficient, and on their engagement in ongoing educational programs related to orofacial pain. Data were analyzed by Chi-Square Test and Fischer's exact test (p<0.05). Results Overall, self-reported confidence about non-odontogenic pain was high, especially for endodontists who considered their knowledge about orofacial pain sufficient, regardless of whether they had (71.1% - 97.8%) or not (35.7% - 96.4%) been continuously involved in education courses on orofacial pain. In general, self-reported knowledge about non-odontogenic pain was insufficient (0% - 42%), except in the question about how they would act in cases of pain that persists beyond the normal healing time after an endodontic procedure (70.6% - 81.9%). In general, endodontists are confident in their diagnosis and treatment of non-odontogenic pain. Nonetheless, this confidence did not correlate with a commensurate knowledge depth of. Thus, specialization courses in endodontics should highly consider training and qualifying these professionals in the diagnosis of non-odontogenic pain.

8.
Eur Endod J ; 7(3): 217-222, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36217638

RESUMO

OBJECTIVE: To evaluate the solubility, pH, antimicrobial action, and cytotoxicity of ambroxol hydrochloride (AMB), N-acetylcysteine (NAC), and calcium hydroxide (CH) pastes for use as intracanal medications. METHODS: Solubility was determined by micro-CT, based on the paste volume remaining after immersion in water for 7 days. pH was measured by immersing acrylic tubes containing the pastes in ultrapure water and then measuring pH after 3 hours, 3 days, and 7 days. Antimicrobial action against Enterococcus faecalis was assessed based on the percentage of living cells, using the live/dead staining method under confocal microscopy. Cytotoxicity was assessed based on the cell viability of L929 fibroblast-like cells after 6, 24, and 48 hours. Cytotoxicity data were compared using the ANOVA and Tukey tests, and the antimicrobial data were compared using the Kruskal-Wallis and Dunn tests. The significance level used was 5% (α=0.05). RESULTS: The solubility values for all the study groups were significantly different (P<0.05), where the highest values were for NAC, followed by AMB, and then CH. Likewise, the pH levels were all significantly different (P<0.05), where NAC and AMB levels were acidic, and CH levels were alkaline. The antimicrobial action of AMB was significantly higher than that of CH (P<0.05), and that of NAC was also higher than that of CH, albeit not significantly. AMB and NAC were more cytotoxic than CH, and higher dilutions of CH promoted higher cell viability levels than lower dilutions of the same paste (P<0.05). CONCLUSION: The NAC and AMB pastes were more soluble and cytotoxic than the CH paste and had acidic pH levels. The AMB paste displayed the highest antimicrobial action against Enterococcus faecalis biofilm.


Assuntos
Ambroxol , Anti-Infecciosos , Acetilcisteína/farmacologia , Ambroxol/farmacologia , Anti-Infecciosos/farmacologia , Hidróxido de Cálcio/toxicidade , Fenômenos Químicos , Enterococcus faecalis , Água
9.
J Appl Oral Sci ; 30: e20220108, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35920449

RESUMO

OBJECTIVE: Filling materials should be restricted to the root canal space. However, sometimes it is impossible to control the apical extrusion, in this case, the fate of the filling material and the result of the treatment will depend on its physicochemical properties and biocompatibility. To evaluate the tissue response and bone repair capacity of endodontic sealers that were implanted in the calvaria of Wistar rats, forming the groups (n=16): AH Plus and Sealer Plus, compared to the clot group. METHODOLOGY: On days 30 and 60, the animals were euthanized, the calvaria was removed and processed for hematoxylin-eosin, immunohistochemistry for collagen type I, Picrosirus red and microtomographic analysis. Data were subjected to ANOVA and Tuckey tests (p<0.05). RESULTS: At 30 days, all groups showed an intense inflammatory reaction (p>0.05). At 60 days, the AH Plus and Sealer Plus maintained an intense inflammatory infiltrate compared to the clot group (p<0.05). We observed immunopositive areas for type I collagen in all groups at 30 days and 60 days (p>0.05). We observed more red collagen fibers for the Sealer Plus compared to the clot group at 30 days (p<0.05). Considering the total fibers, the clot group at 30 days compared to 60 days after surgery showed an increase in the amount of matrix (p<0.05). There were no statistical differences between groups for green and yellow fibers (p>0.05). Regarding morphometric parameters, at 30 days, the newly formed bone volume and number of bone trabeculae were higher in the groups with sealers compared to the clot group (p<0.05). At 60 days, AH Plus and Sealer Plus showed greater bone neoformation compared to the clot group (p<0.05). CONCLUSIONS: Despite AH Plus and Sealer Plus induced an intense inflammatory reaction, they can be considered biocompatible materials, since they allowed bone repair.


Assuntos
Materiais Restauradores do Canal Radicular , Animais , Materiais Biocompatíveis , Resinas Epóxi , Teste de Materiais , Ratos , Ratos Wistar , Materiais Restauradores do Canal Radicular/farmacologia , Tratamento do Canal Radicular , Silicatos/farmacologia , Cicatrização
10.
Braz Oral Res ; 36: e085, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35703710

RESUMO

The aim of this study was to evaluate the quality of curved root canal preparation, torsional fatigue, and cyclic fatigue of rotary systems manufactured with different NiTi alloys. Ninety single-rooted canals with curvatures of 15° to 30o were scanned and divided into three groups according to the rotary system used: BT-Race (BTR) - 10.06, 35.00, 35.04; SequenceRotaryFile (SRF) - 15.04, 25.06, 35.04; and ProDesignLogic (PDL) - 25.01, 25.06, 35.05. Each system was used on three specimens. The teeth were prepared, scanned, and analyzed to assess increase in volume, transportation, and centering ability of the root canal. Torsional fatigue of glide path instruments (BTR 10.06, SRF 15.04 and PDL 25.01) and cyclic fatigue of the finishing instrument (BTR 35.04, SRF 35.04 and PDL 35.05) were obtained by analyzing completely new instruments (n = 10) and instruments after they had been used three times (n = 10). After the torsional and cyclic fatigue tests, the fractured surface of the new and used instruments were examined by scanning electron microscopy. Increase in volume, canal transportation, and centering ability showed no significant differences among the groups (p > 0.05). The torsional test showed that SRF 15.04 produced the highest torque values for both new and used instruments, followed by PDL 25.01 and BTR 10.06 (p < 0.05). PDL 25.01, both new and used, exhibited higher values of angular deflection followed by SRF 15.04 and BTR 10.06 (p < 0.05). As regards cyclic fatigue, use of PDL 35.05, both new and used, required a longer time and larger number of cycles than did SRF 35.04 and BTR 35.04 (p < 0.05). Clinical use affected the torsional fatigue of BTR; however, cyclic fatigue was not significantly affected (p < 0.05). All rotary systems were able to prepare the curved canals satisfactorily and were used safely on the three specimens. Relative to torsional fatigue, SRF 15.04 exhibited a higher torque, and PDL 25.01, higher angular deflection. BTR 10.06 was the most affected by clinical use. PDL 35.05 showed greater resistance to cyclic fatigue.


Assuntos
Ligas Dentárias , Preparo de Canal Radicular , Instrumentos Odontológicos , Desenho de Equipamento , Falha de Equipamento , Teste de Materiais , Níquel , Estresse Mecânico , Titânio , Torção Mecânica
11.
J. res. dent ; 10(2): 1-6, apr.-jun2022.
Artigo em Inglês | LILACS, BBO | ID: biblio-1395871

RESUMO

Background: The aim of this study was to evaluate the cyclic fatigue and torsional fatigue resistance of three thermally treated rotary instruments, such as: Logic 2 25.05 (LOG 25.05), Edge Taper Platinum 25.06 (EDT 25.06) and ProTaper Gold 25.08 (PTG 25.08).Methods: A total of 60 rotary instruments of LOG 25.05, EDT 25.06 and PTG 25.08 were used (n=20). Cyclic fatigue tests were performed at 36°C using an artificial stainless steel canal with a 60ºangle and a 5-mm radius of curvature. The time (in seconds) and number of cycles to fracture (NCF) was recorded. The torsional test evaluated the torque and angle of rotation to failure at 3 mm from the tip according to ISO 3630-1. The fractured surface of each fragment was observed by using scanning electron microscopy (SEM). Data were analyzed using one-way ANOVA and Holm-Sidak's tests for multiple comparison, the level of significance was set at 5%.Results: EDT 25.06 had highest cyclic fatigue resistance (time and NFC), followed by LOG 25.05 and PTG 25.08 (P<0.05). There were no significantly difference between LOG 25.05 and ETP 25.06 regarding the NCF (P>0.05). In relation the torsional test, the LOG 25.05 and ETP 25.06 presented similar torque (P>0.05). The PTG presented greater torque than the other groups (P<0.05). The PTG 25.08 presented the lowest angular rotation to fracture than the other groups (P<0.05). The SEM images demonstrated typical features of cyclic and torsional fracture.Conclusion: In conclusion, the LOG 25.05 and ETP 25.06 presented similar cyclic and torsional properties. The PTG 25.08 showed greater torsional strength.


Assuntos
Humanos , Endodontia
12.
Iran Endod J ; 17(3): 132-137, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36704086

RESUMO

Introduction: The aim of this study was to evaluate the bending and cyclic fatigue resistance of Wave One Gold (WOG) and X1 Blue (X1B) instruments when tested at body temperature (36°C ± 1°C) with and without subjected to an alloy cooling protocol. Materials and Methods: A total of sixty instruments (n=30) were tested. Forty instruments (n=20) were randomly selected and divided into two groups: body temperature (BT; n=20) and body temperature with cooling protocol (CP; n=20). Cyclic fatigue test was performed until fracture in a conventional stainless-steel device with water bath equipment to simulate body temperature. CP group instruments were subjected to 5 seconds of spray cooling every 30 seconds. Time to fracture was recorded in seconds. Resistance to bending at an angle of 45 degrees was evaluated using twenty instruments (n=10). Fractured surfaces were examined under scanning electron microscopy (SEM). Statistical analysis was performed at a 5% significance level. Results: There was no difference in the cyclic fatigue resistance between instruments in BT groups (P>0.05). Cooling protocol significantly increased the cyclic fatigue resistance of X1B instruments (P=0.0003) and WOG instruments (P=0.0003). Results: WOG instruments had a significantly lower cyclic fatigue resistance compared to X1B instruments in CP group (P=0.0001). There were no significant differences between the values of resistance increase presented by the instruments after cooling (P>0.05). Bending test presented no statistically significant differences between the tested instruments (P>0.05). Both instruments in both groups showed typical features of cyclic fatigue behavior under SEM. Conclusions: X1 Blue #25.06 and WaveOne Gold #25.07 instruments presented similar cyclic fatigue resistance. The investigated clinical-replicable cooling protocol improved the cyclic fatigue resistance of the tested instruments, with X1 Blue #25.06 presenting a greater cyclic fatigue resistance after cooling. Both instruments presented a similar bending capacity.

13.
J. appl. oral sci ; 30: e20220108, 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1386007

RESUMO

Abstract Filling materials should be restricted to the root canal space. However, sometimes it is impossible to control the apical extrusion, in this case, the fate of the filling material and the result of the treatment will depend on its physicochemical properties and biocompatibility. Objective To evaluate the tissue response and bone repair capacity of endodontic sealers that were implanted in the calvaria of Wistar rats, forming the groups (n=16): AH Plus and Sealer Plus, compared to the clot group. Methodology On days 30 and 60, the animals were euthanized, the calvaria was removed and processed for hematoxylin-eosin, immunohistochemistry for collagen type I, Picrosirus red and microtomographic analysis. Data were subjected to ANOVA and Tuckey tests (p<0.05). Results At 30 days, all groups showed an intense inflammatory reaction (p>0.05). At 60 days, the AH Plus and Sealer Plus maintained an intense inflammatory infiltrate compared to the clot group (p<0.05). We observed immunopositive areas for type I collagen in all groups at 30 days and 60 days (p>0.05). We observed more red collagen fibers for the Sealer Plus compared to the clot group at 30 days (p<0.05). Considering the total fibers, the clot group at 30 days compared to 60 days after surgery showed an increase in the amount of matrix (p<0.05). There were no statistical differences between groups for green and yellow fibers (p>0.05). Regarding morphometric parameters, at 30 days, the newly formed bone volume and number of bone trabeculae were higher in the groups with sealers compared to the clot group (p<0.05). At 60 days, AH Plus and Sealer Plus showed greater bone neoformation compared to the clot group (p<0.05). Conclusions Despite AH Plus and Sealer Plus induced an intense inflammatory reaction, they can be considered biocompatible materials, since they allowed bone repair.

14.
Braz. oral res. (Online) ; 36: e080, 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO | ID: biblio-1384188

RESUMO

Abstract This study aimed to evaluate the root canal real length (RL) changes due to the mechanical instrumentation use with different flaring magnitudes. After access cavity, 60 mesial root canals of mandibular molars were randomly separated in three groups: Hyflex EDM (HF; #25/.12, #10/.05 e #25/~), Reciproc Blue (RB; R25), and MTwo (M2; #10/.04, #15/.05, #20/.06 e #25/.06). The RL was defined as the apical limit, and 2.5% sodium hypochlorite irrigating solution was chosen. After the access cavity (RL 1), cervical flaring (RL 2), and complete chemical-mechanical preparation (RL 3), the RL was evaluated. The RL was evaluated by a blind examiner with the aid of a microscope (16x) placing the endodontic file stop at the coronary reference. When comparing length measurements, the RL was shorter before instrumentation than that after instrumentation. A reduction of 0.65 mm (HF), 0.61 mm (RB), and 0.48 mm (M2) was observed. However, among groups, no statistical differences were found (p > 0.05). Under the conditions tested, it can be inferred that all mechanical systems provoked RL variations, which emphasizes the need for constant verification of the odontometry, mainly before root canal obturation.

15.
Braz. oral res. (Online) ; 36: e085, 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO | ID: biblio-1384205

RESUMO

Abstract The aim of this study was to evaluate the quality of curved root canal preparation, torsional fatigue, and cyclic fatigue of rotary systems manufactured with different NiTi alloys. Ninety single-rooted canals with curvatures of 15° to 30o were scanned and divided into three groups according to the rotary system used: BT-Race (BTR) - 10.06, 35.00, 35.04; SequenceRotaryFile (SRF) - 15.04, 25.06, 35.04; and ProDesignLogic (PDL) - 25.01, 25.06, 35.05. Each system was used on three specimens. The teeth were prepared, scanned, and analyzed to assess increase in volume, transportation, and centering ability of the root canal. Torsional fatigue of glide path instruments (BTR 10.06, SRF 15.04 and PDL 25.01) and cyclic fatigue of the finishing instrument (BTR 35.04, SRF 35.04 and PDL 35.05) were obtained by analyzing completely new instruments (n = 10) and instruments after they had been used three times (n = 10). After the torsional and cyclic fatigue tests, the fractured surface of the new and used instruments were examined by scanning electron microscopy. Increase in volume, canal transportation, and centering ability showed no significant differences among the groups (p > 0.05). The torsional test showed that SRF 15.04 produced the highest torque values for both new and used instruments, followed by PDL 25.01 and BTR 10.06 (p < 0.05). PDL 25.01, both new and used, exhibited higher values of angular deflection followed by SRF 15.04 and BTR 10.06 (p < 0.05). As regards cyclic fatigue, use of PDL 35.05, both new and used, required a longer time and larger number of cycles than did SRF 35.04 and BTR 35.04 (p < 0.05). Clinical use affected the torsional fatigue of BTR; however, cyclic fatigue was not significantly affected (p < 0.05). All rotary systems were able to prepare the curved canals satisfactorily and were used safely on the three specimens. Relative to torsional fatigue, SRF 15.04 exhibited a higher torque, and PDL 25.01, higher angular deflection. BTR 10.06 was the most affected by clinical use. PDL 35.05 showed greater resistance to cyclic fatigue.

16.
Braz. oral res. (Online) ; 36: e100, 2022. tab, graf
Artigo em Português | LILACS-Express | LILACS, BBO | ID: biblio-1403959

RESUMO

Abstract This study aimed to evaluate physicochemical properties of three ready-to-use calcium silicate-based endodontic sealers: Endosequence BC Sealer, Bio C Sealer, and Sealer Plus BC. Radiopacity was evaluated using specimens of 10 mm in diameter and 1 mm in height, along with an aluminum step wedge. For the flow test, 0.5 mL of each sealer was deposited between glass plates and the mean of the measurement of two diameters was considered the cement flow value. For pH and calcium release, root canals of 30 prototypes of upper incisor acrylic resin teeth were filled with sealer and gutta percha point and then immersed in containers with 13 mL of ultrapure water. Both pH and release of calcium ions (atomic absorption spectrophotometer) were measured at 3, 24, 72, and 168 h. Acrylic resin teeth were scanned by Micro-CT 1174 at the time of pH and calcium ion readings for volumetric change analysis. The data were analyzed by ANOVA, Tukey's, Kruskal-Wallis, and Dunn's tests. Endosequence BC Sealer presented the lowest, and Bio C Sealer the highest volumetric change after 72 h and 168 h (p < 0.05). Endosequence BC Sealer presented higher radiopacity (p < 0.05). All materials showed alkalinization capacity. All of them presented calcium ion release, with a higher value for Sealer Plus BC. All materials presented alkalinization, calcium release capacity, radiopacity, and flow above the minimum values required by the ISO standard. The highest volumetric loss was experienced by Bio C Sealer and the lowest one by Endosequence BC Sealer.

17.
J. res. dent ; 9(3): 12-18, sep.-dec2021.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1358579

RESUMO

Background: Infection control is mandatory for revascularization procedures, enabling to eliminate patient's clinical symptoms and signs. Despite presenting a complex morphology when compared to anterior teeth, if a strict disinfection protocol is adopted and the revascularization procedure's biological principles are followed, the therapy can be successful in molar teeth. Methods: This case report aims to present a clinical case of successful revascularization in an immature permanent necrotic second lower molar. Clinical decisions and explanations regarding possible mechanisms related to the treatment's success in a tooth with complex morphology are discussed. Results: Revascularization procedures were performed on a 12-year-old male patient diagnosed with symptomatic periapical periodontitis in a tooth 37. The case highlights the need for infection control and biological principles that surrounds the success of this therapy. Follow-up times presented in this case were six months, 1, 2, 4 and 4.5-years, respectively. Continued root development was observed, and the tooth remains intact and without symptoms. Conclusion: The association of infection control and the biological principles of revascularization procedures allow the maintenance and continuation of tooth development, even when these present complex morphologies.

18.
Braz. j. oral sci ; 20: e212098, jan.-dez. 2021. ilus
Artigo em Inglês | BBO, LILACS | ID: biblio-1281101

RESUMO

Aim: This study aimed to evaluate the pH, Ca2+ release, solubility, and antimicrobial activity of calcium hydroxide (Ca(OH)2) pastes in association with different substances. Methods: Sixty acrylic teeth (n=10) were filled with pastes that associated Ca(OH)2 with the following substances: benzalkonium chloride 5% (G1) and 50% (G2) both in propylene glycol, arnica glycolic extract (G3), green tea glycolic extract (G4), Calen/PMCC™ (G5), and Calen™ (G6). In the group G1 to G4 were used 1g of Ca(OH)2 powder with 0,8g of vehicle. pH and Ca2+ release was measured after 7, 15, and 30 days. For solubility, micro-CT was used immediately and at the periods of 7, 15, and 30 days. For the antimicrobial analysis, a biofilm of E. faecalis was induced in vitro on bovine dentin discs. Live/dead viability dye and confocal scanning microscopy were used. Results: The highest pH values occurred on the first 7 days, and the G6, G1, G3, and G5 presented the highest pH values at this period (P <0.05). Ca2+ release was higher in all groups at 7 days, with the highest values observed in G1, G5, and G6. The volume of all pastes showed no significant difference in the intragroup analysis at 7 and 15 days (P <0.05). G1 and G2 showed the highest antimicrobial action (P <0.05). For the biovolume, there was difference between the G6 and the other groups (P >0.05) with G1 presenting the lowest values. Conclusion: Benzalkonium chloride 5% increases the antimicrobial action of the Ca(OH2), without impairs physicochemical properties


Assuntos
Materiais Restauradores do Canal Radicular , Hidróxido de Cálcio , Biofilmes , Fenômenos Químicos , Anti-Infecciosos
19.
Aust Endod J ; 47(2): 265-272, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33296137

RESUMO

This study investigated the cyclic fatigue, bending, torsional resistance and angular deflection of Pro-R 25.08, Logic RT 25.08, MK Retreatment 25.08 (MK RT) and ProTaper Retreatment D2 instruments. Cyclic fatigue test was performed until fracture in a custom stainless-steel device with water bath equipment to simulate body temperature. Fracture time was recorded. A number of cycles were calculated. Resistance to bending at 45°, torsional resistance and angular deflection were evaluated. The fracture surfaces were examined by scanning electron microscopy. Statistical analysis was performed with one-way ANOVA and Tukey and Kruskal-Wallis and Dunn tests. Pro-R and Logic RT presented the highest cyclic fatigue (P < 0.05). D2 had higher strength to bend than Pro-R and Logic RT (P < 0.05). Logic RT showed the highest torque and angular deflection (P < 0.05), without differences when compared to D2 (P > 0.05). Instrument performances were dependent on their geometrical features and heat treatments.


Assuntos
Níquel , Titânio , Ligas Dentárias , Desenho de Equipamento , Falha de Equipamento , Teste de Materiais , Retratamento , Preparo de Canal Radicular , Estresse Mecânico , Torção Mecânica
20.
Int. j. odontostomatol. (Print) ; 14(4): 632-638, dic. 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1134550

RESUMO

ABSTRACT: The aim of this in vitro study was to investigate the influence of ethylenediaminetetraacetic acid (EDTA) associated with the benzalkonium chloride (BAK) on the adhesion and formation of Enterococcus faecalis biofilms attached to coated dentin. Discs standard bovine dentin blocks were treated with the coating materials evaluated: Saline solution (control), 17 % EDTA, 17 % EDTA associated with 1 % BAK for 5 minutes and subsequently washed with saline solution. Afterwards, biofilms of E. faecalis (ATCC 29212) were grown on the surface of coated dentin blocks for time intervals of 1 hour and 7 days (n = 20) and were subsequently washed with phosphate-buffered saline (PBS). Bacterial viability and total biovolume were analyzed by confocal laser scanning microscopy (CLSM) using the Live/Dead technique. Nonparametric Kruskal-Wallis followed by Dunn tests were used to determine statistical differences (a = 5 %). The 17 % EDTA + 1 % BAK group showed significantly lower biovolume and bacterial viability values at the end of 1 hour (p < 0.05). After 7 days of contamination, the 17 % EDTA and 17 % EDTA + 1 % BAK groups showed similar results that differed statistically from those of the control group (p < 0.05). The saline solution group showed higher values. The use of BAK associated with EDTA on dentin blocks surfaces before exposure to contamination was able to interfere in the adhesion of E. faecalis to dentin. Also, dentin treatment by BAK associated with a chelating agent influences the secondary biofilm formation, which could have important effects on the long-term success of root canal treatment.


RESUMEN: El objetivo del estudio consistió en investigar in vitro, la influencia del ácido etilendiamino-tetraacético (EDTA) con cloruro de benzalconio (BAK) en la adhesión y formación de biopelículas de Enterococcus faecalis a la dentina. Discos de dentina bovina fueron tratadas con solución salina (control), 17 % de EDTA, 17% de EDTA asociado con 1 % de BAK durante 5 minutos y lavadas con solución salina. Las biopelículas de E. faecalis (ATCC 29212) se cultivaron sobre los discos de dentina durante intervalos de tiempo de 1 hora y 7 días (n = 20), lavados con solución salina tamponada con fosfato (PBS). La viabilidad bacteriana y el biovolumen total se analizaron mediante microscopía de barrido por láser (CLSM) utilizando la técnica Live / Dead. Se realizó prueba no paramétrica de Kruskal-Wallis, seguida por Dunn con una diferencia estadística (a = 5 %). El grupo de 17 % EDTA + 1 % BAK mostró valores significativamente menores de biovolumen y viabilidad bacteriana al final de 1 hora (p < 0,05). Después de 7 días de contaminación, los grupos de 17 % EDTA y 17 % EDTA + 1 % BAK mostraron resultados similares que diferían estadísticamente del grupo control (p < 0,05). La solución salina mostró valores más altos. La asociación de BAK con EDTA antes de la contaminación interfirió en la adhesión de E. faecalis. Además, el tratamiento de la dentina por BAK asociado con EDTA influye en la formación de biopelículas secundarias, lo que podría tener efectos importantes sobre el éxito a largo plazo del tratamiento del conducto radicular.


Assuntos
Animais , Bovinos , Aderência Bacteriana/efeitos dos fármacos , Ácido Edético/farmacologia , Enterococcus faecalis/crescimento & desenvolvimento , Enterococcus faecalis/efeitos dos fármacos , Biofilmes/efeitos dos fármacos , Dentina/microbiologia , Compostos de Benzalcônio/farmacologia , Microscopia Confocal , Solução Salina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA