Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Laryngoscope ; 2024 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-38989899

RESUMO

OBJECTIVES: Training of temporal bone drilling requires more than mastering technical skills with the drill. Skills such as visual imagery, bimanual dexterity, and stress management need to be mastered along with precise knowledge of anatomy. In otorhinolaryngology, these psychomotor skills underlie performance in the drilling of the temporal bone for access to the inner ear in cochlear implant surgery. However, little is known about how psychomotor skills and workload management impact the practitioners' continuous and overall performance. METHODS: To understand how the practitioner's workload and performance unfolds over time, we examine task-evoked pupillary responses (TEPR) of 22 medical students who performed transmastoid-posterior tympanotomy (TMPT) and removal of the bony overhang of the round window niche in a 3D-printed model of the temporal bone. We investigate how students' TEPR metrics (Average Pupil Size [APS], Index of Pupil Activity [IPA], and Low/High Index of Pupillary Activity [LHIPA]) and time spent in drilling phases correspond to the performance in key drilling phases. RESULTS: All TEPR measures revealed significant differences between key drilling phases that corresponded to the anticipated workload. Enlarging the facial recess lasted significantly longer than other phases. IPA captured significant increase of workload in thinning of the posterior canal wall, while APS revealed increased workload during the drilling of the bony overhang. CONCLUSION: Our findings contribute to the contemporary competency-based medical residency programs where objective and continuous monitoring of participants' progress allows to track progress in expertise acquisition. Laryngoscope, 2024.

2.
Eur Arch Otorhinolaryngol ; 281(2): 701-710, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37505263

RESUMO

PURPOSE: The opportunities for surgical training and practice in the operating room are in decline due to limited resources, increased efficiency demands, growing complexity of the cases, and concerns for patient safety. Virtual reality (VR) offers a novel opportunity to enhance surgical training and provide complementary three-dimensional experience that has been usually available in the operating room. Since VR allows viewing and manipulation of realistic 3D models, the VR environment could enhance anatomical and topographical knowledge, in particular. In this study, we explored whether incorporating VR anatomy training improves novices' performance during mastoidectomy over traditional methods. METHODS: Thirty medical students were randomized into two groups and taught mastoidectomy in a structured manner. One group utilized a VR temporal bone model during the training while the other group used more traditional materials such as anatomy books. After the training, all participants completed a mastoidectomy on a 3D-printed temporal bone model under expert supervision. Performance during the mastoidectomy was evaluated with multiple metrics and feedback regarding the two training methods was gathered from the participants. RESULTS: The VR training method was rated better by the participants, and they also needed less guidance during the mastoidectomy. There were no significant differences in operational time, the occurrence of injuries, self-assessment scores, and the surgical outcome between the two groups. CONCLUSION: Our results support the utilization of VR training in complete novices as it has higher trainee satisfaction and leads to at least as good results as the more traditional methods.


Assuntos
Otolaringologia , Treinamento por Simulação , Realidade Virtual , Humanos , Mastoidectomia/educação , Estudos Prospectivos , Otolaringologia/educação , Treinamento por Simulação/métodos , Competência Clínica
3.
World Neurosurg ; 175: e614-e635, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37030483

RESUMO

BACKGROUND: Hyperspectral imaging (HSI) has the potential to enhance surgical tissue detection and diagnostics. Definite utilization of intraoperative HSI guidance demands validated machine learning and public datasets that currently do not exist. Moreover, current imaging conventions are dispersed, and evidence-based paradigms for neurosurgical HSI have not been declared. METHODS: We presented the rationale and a detailed clinical paradigm for establishing microneurosurgical HSI guidance. In addition, a systematic literature review was conducted to summarize the current indications and performance of neurosurgical HSI systems, with an emphasis on machine learning-based methods. RESULTS: The published data comprised a few case series or case reports aiming to classify tissues during glioma operations. For a multitissue classification problem, the highest overall accuracy of 80% was obtained using deep learning. Our HSI system was capable of intraoperative data acquisition and visualization with minimal disturbance to glioma surgery. CONCLUSIONS: In a limited number of publications, neurosurgical HSI has demonstrated unique capabilities in contrast to the established imaging techniques. Multidisciplinary work is required to establish communicable HSI standards and clinical impact. Our HSI paradigm endorses systematic intraoperative HSI data collection, which aims to facilitate the related standards, medical device regulations, and value-based medical imaging systems.


Assuntos
Neoplasias Encefálicas , Glioma , Humanos , Imageamento Hiperespectral , Diagnóstico por Imagem , Aprendizado de Máquina , Glioma/diagnóstico por imagem , Glioma/cirurgia , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/cirurgia
4.
Cancer Treat Res Commun ; 32: 100615, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35905671

RESUMO

BACKGROUND: 5-aminolevulinic acid (5-ALA) - precursor of protoporphyrin IX (PpIX) - is utilized in fluorescence guided surgery (FGS) of high-grade gliomas. PpIX is used to identify traces of glioma during resection. Visual inspection of the fluorescence seems inaccurate in comparison to optic techniques such as hyperspectral imaging (HSI). AIM: To characterize the limits of PpIX fluorescence detection of (i) visual evaluation and (ii) HSI analysis and to (iii) develop a classification system for visible and non-visible PpIX fluorescence. METHODS: Samples with increasing concentrations (C) of PpIX and non-fluorescent controls were evaluated using a surgical microscope under blue light illumination. Similar samples were imaged with a HSI system tuned to PpIX fluorescence peak wavelength (635 nm) and control (RGB) channels. Samples' intensities were defined, leading to 96 analysed pixels after batching. RESULTS: Three expert neurosurgeons assessed the PpIX samples (n = 16) and controls (n = 8) with unanimous decisions (ICC = 0.704), resulting in 63% recognition rate, 48% sensitivity, 92% specificity, 92% positive predictive value (PPV) and 47% negative predictive value (NPV). HSI image analysis, comparing mean relative values, resulted in 96%, 100%, 86%, 94%, 100%, respectively. Minimum PpIX concentration detection for experts was 0.6-1.8 µmol/l and HSI's 0.03-0.15 µmol/l. CONCLUSIONS: PpIX concentrations of low-grade gliomas, and those reported on glioblastoma infiltration zones, are below experts' detection threshold. HSI analysis exceeds the performance of expert's visual inspection nearly by 20-fold. Hybrid FGS-HSI systems should be investigated in parallel to long-term outcomes. Described methods are applicable as a standard for calibration, testing and development of subvisual FGS techniques.


Assuntos
Neoplasias Encefálicas , Glioma , Ácido Aminolevulínico , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/cirurgia , Glioma/diagnóstico por imagem , Glioma/cirurgia , Humanos , Imageamento Hiperespectral , Fármacos Fotossensibilizantes , Protoporfirinas
5.
J Invest Surg ; 35(6): 1340-1349, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35038963

RESUMO

BackgroundEye tracking is a powerful tool for unobtrusive and real time assessment of workload in clinical settings. Before the complex eye tracking derived surrogates can be proactively utilized to improve surgical safety, the indications, validity and reliability requires careful evaluation.MethodsWe conducted a systematic review of literature from 2010 to 2020 according to PRISMA guidelines. A search on PubMed, Cochrane, Scopus, Web of science, PsycInfo and Google scholar databases was conducted on July 2020. The following search query was used" ("eye tracking" OR "gaze tracking") AND (surgery OR surgical OR operative OR intraoperative) AND (workload OR stress)". Short papers, no peer reviewed or papers in which eye-tracking methodology was not used to investigate workload or stress factors in surgery, were omitted.ResultsA total of 17 (N = 17) studies were identified eligible to this review. Most of the studies (n = 15) measured workload in simulated setting. Task difficulty and expertise were the most studied factors. Studies consistently showed surgeon's eye movements such as pupil responses, gaze patterns, blinks were associated with the level of perceived workload. However, differences between measurements in operational room and simulated environments have been found.ConclusionPupil responses, blink rate and gaze indices are valid indicators of workload. However, the effect of distractions and non-technical factors on workload is underrepresented aspect in the literature even though recognized as underlying factors in successful surgery.


Assuntos
Tecnologia de Rastreamento Ocular , Carga de Trabalho , Movimentos Oculares , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA