Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Knee Surg ; 37(3): 193-197, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37023764

RESUMO

BACKGROUND: Surgical repair is indicated for patellar tendon ruptures that result in loss of knee extensor mechanism function. However, biomechanical studies report conflicting results when comparing transosseous suture versus suture anchor repair techniques. This discrepancy may be due to inconsistencies in experimental design as these studies use various numbers of suture strands. Therefore, the main objective of this study is to compare the ultimate load of four- versus six-strand transosseous suture repair. Secondary objectives are to compare gap formation after cyclical loading and mode of failure. METHODS: Six pairs of fresh-frozen cadaveric specimen were randomly allocated to either four- or six-strand transosseous suture repair. Specimen underwent preconditioning cyclical loading and then load to failure. RESULTS: The six-strand repair had a significantly higher maximum load to failure compared with the four-strand repair (mean difference = 319.3 N [57.9%], p = 0.03). There was no significant difference in gap length after cyclical loading or at max load. There were no significant differences in mode of failure. CONCLUSION: Utilizing a six-stand transosseous patella tendon repair construct with one additional suture increases overall construct strength by over 50% compared with a four-strand construct.


Assuntos
Traumatismos do Joelho , Ligamento Patelar , Procedimentos de Cirurgia Plástica , Traumatismos dos Tendões , Humanos , Ligamento Patelar/cirurgia , Fenômenos Biomecânicos , Traumatismos dos Tendões/cirurgia , Traumatismos do Joelho/cirurgia , Suturas , Técnicas de Sutura , Âncoras de Sutura , Cadáver , Ruptura/cirurgia
2.
J Knee Surg ; 35(5): 521-528, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32898902

RESUMO

The purpose of this study was to evaluate Patient-Reported Outcomes Measurement Information System physical function (PROMIS PF) 2 years following knee surgery, and identify preoperative factors associated with postoperative PROMIS PF. Three hundred and sixty-five patients, age 17 years and older, undergoing knee surgery at one institution were studied. Patients completed multiple questionnaires prior to surgery and again 2 years postoperatively including PROMIS PF, International Knee Documentation Committee (IKDC), joint and body numeric pain scales (NPS), Tegner's activity scale (TAS), and Marx's activity rating scale (MARS). Mean PROMIS PF improved from 41.4 to 50.9 at 2 years postoperatively (p < 0.001) and was strongly correlated with 2-year IKDC scores. Older age, female gender, non-Hispanic ethnicity, unemployment, lower income, government insurance, smoking, preoperative opioid use, having a legal claim, comorbidities, previous surgeries, higher body mass index (BMI), and knee arthroplasty were associated with worse 2-year PROMIS PF. Multivariable analysis confirmed that lower BMI, less NPS body pain, and higher MARS were independent predictors of greater 2-year PROMIS PF and better improvement in PROMIS PF. In this large, broad cohort of knee surgery patients, multiple preoperative factors were associated with PROMIS PF 2 years postoperatively. PROMIS PF scores improved significantly, but worse 2 year PROMIS PF scores and less improvement from baseline were independently predicted by higher BMI, greater NPS body pain, and lower MARS activity level. PROMIS PF can be implemented as an efficient means to assess outcomes after knee surgery.


Assuntos
Procedimentos Ortopédicos , Medidas de Resultados Relatados pelo Paciente , Adolescente , Feminino , Humanos , Joelho/cirurgia , Articulação do Joelho/cirurgia , Dor
3.
J Clin Orthop Trauma ; 20: 101486, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34277340

RESUMO

BACKGROUND: Patient satisfaction metrics are increasingly being utilized as tools to evaluate the quality of healthcare and affect reimbursements. The objectives of this study were to (1) identify factors associated with two-year patient satisfaction after elective knee surgery, (2) compare the Surgical Satisfaction Questionnaire-8 (SSQ-8) and a numeric satisfaction scale (NSS), and (3) determine if two-year patient satisfaction can be predicted based on preoperative factors. METHODS: A total of 365 patients undergoing elective knee surgery at a single center were administered questionnaires to assess demographics, medical history, and various patient-reported outcomes preoperatively and at two years postoperatively. Patient satisfaction was measured at two years postoperatively with SSQ-8 and NSS. Bivariate and multivariate statistical analyses were performed to identify significant associations and independent predictors of satisfaction. RESULTS: SSQ-8 and NSS scores were significantly correlated (rs = 0.68, P < 0.0001). Lower SSQ-8 and NSS scores were associated with black race, higher BMI, more comorbidities, unemployment, smoking, higher ASA score, and greater Met Expectations (P < 0.05). Better scores on patient-based outcome measures and better improvement from baseline were significantly correlated with higher satisfaction on both SSQ-8 and NSS. Multivariable analysis identified greater Met Expectations and higher two-year Patient-Reported Outcomes Measurement Information System (PROMIS) Pain Interference scores as independent predictors of greater SSQ-8 scores (adjusted r2 = .52). Greater Met Expectations and better two-year PROMIS Social Satisfaction scores were independent predictors of NSS score (adjusted r2 = .41). In contrast, when only preoperative variables were considered, the multivariable regression model accounted for only 14% of the variance in SSQ-8 and 6% of the variance in NSS. CONCLUSION: While there are multiple preoperative factors that are associated with two-year patient satisfaction after knee surgery, those factors contribute relatively little to satisfaction. Meeting expectations and better patient-based outcomes at two years are more important.

4.
J Orthop ; 25: 10-15, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33897134

RESUMO

INTRODUCTION: The purpose of this study is to determine which patient factors predict two-year postoperative met expectations in a cohort of patients undergoing knee surgery. Additionally, this study aims to measure the association between met expectations and postoperative outcomes. METHODS: 319 patients undergoing knee surgery at one institution were studied. Patients completed patient-reported outcome questionnaires prior to surgery and again two years postoperatively. Preoperative Expectations and postoperative Met Expectations were measured using the Musculoskeletal Outcomes and Data Evaluation Management System (MODEMS) Expectations domain. RESULTS: The mean Met Expectations score was significantly lower than the preoperative Expectations Score. Worse two-year Met Expectations were associated with older age, higher BMI, greater comorbidities, more previous surgeries, black race, unemployment, lower income, government insurance, Worker's Compensation, smoking, and no injury prior to surgery. Greater Met Expectations were correlated with better scores on all two-year outcome measures as well as greater improvement on most outcome measures. Race, insurance status, function, mental health, and knee pain were found to be independent predictors of Met Expectations. CONCLUSION: This study identified multiple patient factors and outcome measures that were associated with Met Expectations two years after knee surgery.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA