Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Invest Ophthalmol Vis Sci ; 60(6): 2134-2139, 2019 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-31100106

RESUMO

Purpose: There is no prevention or treatment for diabetic retinal neurodegeneration (DRN), which is a complication of diabetes that can occur independently of diabetic retinopathy (DR). We hypothesized that an intravitreal fluocinolone acetonide (FAc) implant may affect the rate of DRN when used in patients with diabetic macular edema (DME). Methods: In this retrospective analysis, optical coherence tomography with neuroretinal analysis was obtained at 3-month intervals from 130 patients in the USER study both before (mean duration 903 days, range 35-4005 days) and after administration of FAc (mean 408 days, range 7 to 756 days). The rate of DRN was defined as the change over time on inner neuroretinal thickness using logistic regression. A DRN rate was calculated independently for two areas: region 1 located within 1.5 mm of the fovea, and region 2 from 1.5 mm to 3.0 mm from the fovea. Results: In regions of the macula more than 1.5 mm from the central fovea, there was a statistically significant decrease in the rate of DRN in the post-FAc period. The pre-FAc neuroretinal loss in this area occurred at 4.0 µm/y, compared with a post-FAc loss rate of 1.1 µm/y (P = 0.001). Conclusions: This retrospective study suggests that FAc may decelerate the rate of inner retinal thinning in patients with persistent DME. Further prospective studies are necessary to determine the effects of FAc on the rate of DRN in patients with DME.


Assuntos
Anti-Inflamatórios/administração & dosagem , Retinopatia Diabética/tratamento farmacológico , Fluocinolona Acetonida/administração & dosagem , Glucocorticoides/administração & dosagem , Degeneração Retiniana/tratamento farmacológico , Idoso , Feminino , Humanos , Injeções Intravítreas , Modelos Logísticos , Edema Macular/tratamento farmacológico , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estudos Retrospectivos , Tomografia de Coerência Óptica
2.
Ophthalmic Epidemiol ; 24(2): 104-110, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-28032805

RESUMO

PURPOSE: To examine the associations of nerve fiber layer (NFL) thickness with other ocular characteristics in older adults. METHODS: Participants in the Beaver Dam Eye Study (2008-2010) underwent spectral domain optical coherence tomography (SD-OCT) scans of the optic nerve head, imaging of optic discs, frequency doubling technology (FDT) perimetry, measurement of intraocular pressure (IOP), and an interview concerning their history of glaucoma and use of drops to lower eye pressure. Self-reported histories of glaucoma and the use of drops to lower eye pressure were obtained at follow-up examinations (2014-2016). RESULTS: NFL thickness measured on OCTs varied by location around the optic nerve. Age was associated with mean NFL thickness. Mean NFL was thinnest in eyes with larger cup/disc (C/D) ratios. Horizontal hemifield defects or other optic nerve-field defects were associated with thinner NFL. NFL in persons who reported taking eye drops for high intraocular pressure was thinner compared to those not taking drops. After accounting for the presence of high intraocular pressure, large C/D ratios or hemifield defects, eyes with thinner NFL in the arcades were more likely (OR = 2.3 for 30 micron thinner NFL, p = 0.04) to have incident glaucoma at examination 5 years later. CONCLUSION: Retinal NFL thickness was associated with a new history of self-reported glaucoma 5 years later. A trial testing the usefulness of NFL as part of a screening battery for predicting glaucoma in those previously undiagnosed might lead to improved case finding and, ultimately, to diminishing the risk of visual field loss.


Assuntos
Glaucoma/diagnóstico , Fibras Nervosas/patologia , Disco Óptico/patologia , Células Ganglionares da Retina/patologia , Adulto , Idoso , Envelhecimento/fisiologia , Estudos Transversais , Feminino , Glaucoma/fisiopatologia , Humanos , Pressão Intraocular , Masculino , Programas de Rastreamento/métodos , Pessoa de Meia-Idade , Hipertensão Ocular/diagnóstico , Tomografia de Coerência Óptica , Transtornos da Visão/fisiopatologia , Campos Visuais/fisiologia
3.
Am J Cardiol ; 118(2): 162-9, 2016 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-27289292

RESUMO

The accepted definition of virtual histology intravascular ultrasound (IVUS-VH) thin-cap fibroatheroma (TCFA) is only a modest predictor of plaque rupture (PR). We sought to determine the relation between IVUS-VH findings and culprit lesions with PR using computational analysis. A total of 80 culprit lesions from 80 patients with stable angina (n = 37), unstable angina (n = 20), and myocardial infarction (n = 23) were divided into those with (n = 15) and without PR (n = 65). By use of automated computational analysis, the standard IVUS-VH TCFA criterion and 124 additional criteria were compared. The standard TCFA definition demonstrated modest ability to discriminate lesions with and without PR (sensitivity 87%, specificity 37%, PPV 0.24, and NPV 0.92). Of 124 additional IVUS-VH TCFA definitions, only 2 improved the discriminative ability even modestly. However, a positive correlation was demonstrated between cavity size and necrotic core percentage (r = 0.78, p <0.01) and a negative correlation with percentage of fibrous tissue (r = -0.81, p <0.01). In conclusion, IVUS-VH criteria were only modestly associated with PR, without significant improvement by varying IVUS-VH TCFA features, but IVUS-VH features of ruptured plaques were strongly correlated with cavity size.


Assuntos
Angina Estável/diagnóstico por imagem , Angina Instável/diagnóstico por imagem , Calcinose/diagnóstico por imagem , Doença da Artéria Coronariana/diagnóstico por imagem , Infarto do Miocárdio/diagnóstico por imagem , Placa Aterosclerótica/diagnóstico por imagem , Ruptura Espontânea/diagnóstico por imagem , Idoso , Angina Estável/cirurgia , Angina Instável/cirurgia , Calcinose/patologia , Doença da Artéria Coronariana/cirurgia , Feminino , Fibrose , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/cirurgia , Necrose , Placa Aterosclerótica/patologia , Estudos Retrospectivos , Ultrassonografia de Intervenção
4.
PeerJ ; 4: e2057, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27257542

RESUMO

Background. Imaging biomarkers hold tremendous promise for precision medicine clinical applications. Development of such biomarkers relies heavily on image post-processing tools for automated image quantitation. Their deployment in the context of clinical research necessitates interoperability with the clinical systems. Comparison with the established outcomes and evaluation tasks motivate integration of the clinical and imaging data, and the use of standardized approaches to support annotation and sharing of the analysis results and semantics. We developed the methodology and tools to support these tasks in Positron Emission Tomography and Computed Tomography (PET/CT) quantitative imaging (QI) biomarker development applied to head and neck cancer (HNC) treatment response assessment, using the Digital Imaging and Communications in Medicine (DICOM(®)) international standard and free open-source software. Methods. Quantitative analysis of PET/CT imaging data collected on patients undergoing treatment for HNC was conducted. Processing steps included Standardized Uptake Value (SUV) normalization of the images, segmentation of the tumor using manual and semi-automatic approaches, automatic segmentation of the reference regions, and extraction of the volumetric segmentation-based measurements. Suitable components of the DICOM standard were identified to model the various types of data produced by the analysis. A developer toolkit of conversion routines and an Application Programming Interface (API) were contributed and applied to create a standards-based representation of the data. Results. DICOM Real World Value Mapping, Segmentation and Structured Reporting objects were utilized for standards-compliant representation of the PET/CT QI analysis results and relevant clinical data. A number of correction proposals to the standard were developed. The open-source DICOM toolkit (DCMTK) was improved to simplify the task of DICOM encoding by introducing new API abstractions. Conversion and visualization tools utilizing this toolkit were developed. The encoded objects were validated for consistency and interoperability. The resulting dataset was deposited in the QIN-HEADNECK collection of The Cancer Imaging Archive (TCIA). Supporting tools for data analysis and DICOM conversion were made available as free open-source software. Discussion. We presented a detailed investigation of the development and application of the DICOM model, as well as the supporting open-source tools and toolkits, to accommodate representation of the research data in QI biomarker development. We demonstrated that the DICOM standard can be used to represent the types of data relevant in HNC QI biomarker development, and encode their complex relationships. The resulting annotated objects are amenable to data mining applications, and are interoperable with a variety of systems that support the DICOM standard.

5.
IEEE Trans Med Imaging ; 23(11): 1391-403, 2004 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-15554127

RESUMO

A novel approach for platform-independent virtual endoscopy in human coronary arteries is presented in this paper. It incorporates previously developed and validated methodology for multimodality fusion of two X-ray angiographic images with pullback data from intravascular ultrasound (IVUS). These modalities pose inherently different challenges than those present in many tomographic modalities that provide parallel slices. The fusion process results in a three- or four-dimensional (3-D/4-D) model of a coronary artery, specifically of its lumen/plaque and media/adventitia surfaces. The model is used for comprehensive quantitative hemodynamic, morphologic, and functional analyses. The resulting quantitative indexes are then used to supplement the model. Platform-independent visualization is achieved through the use of the ISO/IEC-standardized Virtual Reality Modeling Language (VRML). The visualization includes an endoscopic fly-through animation that enables the user to interactively select vessel location and fly-through speed, as well as to display image pixel data or quantification results in 3-D. The presented VRML virtual-endoscopy system is used in research studies of coronary atherosclerosis development, quantitative assessment of coronary morphology and function, and vascular interventions.


Assuntos
Algoritmos , Angioscopia/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Imageamento Tridimensional/métodos , Técnica de Subtração , Interface Usuário-Computador , Angiografia/métodos , Doença da Artéria Coronariana/patologia , Interpretação de Imagem Assistida por Computador/métodos , Reconhecimento Automatizado de Padrão/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ultrassonografia de Intervenção/métodos
6.
IEEE Trans Biomed Eng ; 50(11): 1286-95, 2003 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-14619999

RESUMO

In-stent restenosis is commonly observed in coronary arteries after intervention. Intravascular brachytherapy has been found effective in reducing the recurrence of restenosis after stent placement. Conventional dosing models for brachytherapy with beta (beta) radiation neglect vessel geometry as well as the position of the delivery catheter. This paper demonstrates in computer simulations on phantoms and on in vivo patient data that the estimated dose distribution varies substantially in curved vessels. In simulated phantoms of 50-mm length with a shape corresponding to a 60 degrees - 180 degrees segment of a respectively sized torus, the average dose in 2-mm depth was decreased by 2.70%-7.48% at the outer curvature and increased by 2.95%-9.70% at the inner curvature as compared with a straight phantom. In vivo data were represented in a geometrically correct three-dimensional model that was derived by fusion of intravascular ultrasound (IVUS) and biplane angiography. These data were compared with a simplified tubular model reflecting common assumptions of conventional dosing schemes. The simplified model yielded significantly lower estimates of the delivered radiation and the dose variability as compared with a geometrically correct model (p < 0.001). The estimated dose in ten vessel segments of eight patients was on average 8.76% lower at the lumen/plaque and 6.52% lower at the media/adventitia interfaces (simplified tubular model relative to geometrically correct model). The differences in dose estimates between the two models were significantly higher in the right coronary artery as compared with the left coronary artery (p < 0.001).


Assuntos
Braquiterapia/métodos , Cateterismo/métodos , Reestenose Coronária/patologia , Reestenose Coronária/radioterapia , Modelos Cardiovasculares , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Artérias/patologia , Artérias/fisiopatologia , Artérias/efeitos da radiação , Braquiterapia/instrumentação , Cateterismo/instrumentação , Simulação por Computador , Reestenose Coronária/fisiopatologia , Reestenose Coronária/prevenção & controle , Vasos Coronários/patologia , Vasos Coronários/fisiopatologia , Vasos Coronários/efeitos da radiação , Humanos , Dosagem Radioterapêutica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA