Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Magn Reson Med Sci ; 2024 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-38910138

RESUMO

PURPOSE: To compare the utility of thin-slice fat-suppressed single-shot T2-weighted imaging (T2WI) with deep learning image reconstruction (DLIR) and conventional fast spin-echo T2WI with DLIR for evaluating pancreatic protocol. METHODS: This retrospective study included 42 patients (mean age, 70.2 years) with pancreatic cancer who underwent gadoxetic acid-enhanced MRI. Three fat-suppressed T2WI, including conventional fast-spin echo with 6 mm thickness (FSE 6 mm), single-shot fast-spin echo with 6 mm and 3 mm thickness (SSFSE 6 mm and SSFSE 3 mm), were acquired for each patient. For quantitative analysis, the SNRs of the upper abdominal organs were calculated between images with and without DLIR. The pancreas-to-lesion contrast on DLIR images was also calculated. For qualitative analysis, two abdominal radiologists independently scored the image quality on a 5-point scale in the FSE 6 mm, SSFSE 6 mm, and SSFSE 3 mm with DLIR. RESULTS: The SNRs significantly improved among the three T2-weighted images with DLIR compared to those without DLIR in all patients (P < 0.001). The pancreas-to-lesion contrast of SSFSE 3 mm was higher than those of the FSE 6 mm (P < 0.001) and tended to be higher than SSFSE 6 mm (P = 0.07). SSFSE 3 mm had the highest image qualities regarding pancreas edge sharpness, pancreatic duct clarity, and overall image quality, followed by SSFSE 6 mm and FSE 6 mm (P < 0.0001). CONCLUSION: SSFSE 3 mm with DLIR demonstrated significant improvements in SNRs of the pancreas, pancreas-to-lesion contrast, and image quality more efficiently than did SSFSE 6 mm and FSE 6 mm. Thin-slice fat-suppressed single-shot T2WI with DLIR can be easily implemented for pancreatic MR protocol.

2.
Neuroradiology ; 66(6): 937-945, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38374411

RESUMO

PURPOSE: To evaluate the diagnostic value of T1-weighted 3D fast spin-echo sequence (CUBE) with deep learning-based reconstruction (DLR) for depiction of pituitary adenoma and parasellar regions on contrast-enhanced MRI. METHODS: We evaluated 24 patients with pituitary adenoma or residual tumor using CUBE with and without DLR, 1-mm slice thickness 2D T1WI (1-mm 2D T1WI) with DLR, and 3D spoiled gradient echo sequence (SPGR) as contrast-enhanced MRI. Depiction scores of pituitary adenoma and parasellar regions were assigned by two neuroradiologists, and contrast-to-noise ratio (CNR) was calculated. RESULTS: CUBE with DLR showed significantly higher scores for depicting pituitary adenoma or residual tumor compared to CUBE without DLR, 1-mm 2D T1WI with DLR, and SPGR (p < 0.01). The depiction score for delineation of the boundary between adenoma and the cavernous sinus was higher for CUBE with DLR than for 1-mm 2D T1WI with DLR (p = 0.01), but the difference was not significant when compared to SPGR (p = 0.20). CUBE with DLR had better interobserver agreement for evaluating adenomas than 1-mm 2D T1WI with DLR (Kappa values, 0.75 vs. 0.41). The CNR of the adenoma to the brain parenchyma increased to a ratio of 3.6 (obtained by dividing 13.7, CNR of CUBE with DLR, by 3.8, that without DLR, p < 0.01). CUBE with DLR had a significantly higher CNR than SPGR, but not 1-mm 2D T1WI with DLR. CONCLUSION: On the contrast-enhanced MRI, compared to CUBE without DLR, 1-mm 2D T1WI with DLR and SPGR, CUBE with DLR improves the depiction of pituitary adenoma and parasellar regions.


Assuntos
Adenoma , Aprendizado Profundo , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Neoplasias Hipofisárias , Humanos , Neoplasias Hipofisárias/diagnóstico por imagem , Neoplasias Hipofisárias/cirurgia , Masculino , Feminino , Adenoma/diagnóstico por imagem , Adenoma/cirurgia , Imageamento Tridimensional/métodos , Pessoa de Meia-Idade , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Meios de Contraste , Interpretação de Imagem Assistida por Computador/métodos , Estudos Retrospectivos , Neoplasia Residual/diagnóstico por imagem
3.
Invest Radiol ; 2023 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-37975732

RESUMO

OBJECTIVE: The aim of this study was to evaluate the impact of ultra-high-resolution acquisition and deep learning reconstruction (DLR) on the image quality and diagnostic performance of T2-weighted periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) imaging of the rectum. MATERIALS AND METHODS: This prospective study included 34 patients who underwent magnetic resonance imaging (MRI) for initial staging or restaging of rectal tumors. The following 4 types of oblique axial PROPELLER images perpendicular to the tumor were obtained: a standard 3-mm slice thickness with conventional reconstruction (3-CR) and DLR (3-DLR), and 1.2-mm slice thickness with CR (1.2-CR) and DLR (1.2-DLR). Three radiologists independently evaluated the image quality and tumor extent by using a 5-point scoring system. Diagnostic accuracy was evaluated in 22 patients with rectal cancer who underwent surgery after MRI without additional neoadjuvant therapy (median interval between MRI and surgery, 22 days). The signal-to-noise ratio and tissue contrast were measured on the 4 types of PROPELLER imaging. RESULTS: 1.2-DLR imaging showed the best sharpness, overall image quality, and rectal and lesion conspicuity for all readers (P < 0.01). Of the assigned scores for tumor extent, extramural venous invasion (EMVI) scores showed moderate agreement across the 4 types of PROPELLER sequences in all readers (intraclass correlation coefficient, 0.60-0.71). Compared with 3-CR imaging, the number of cases with MRI-detected extramural tumor spread was significantly higher with 1.2-DLR imaging (19.0 ± 2.9 vs 23.3 ± 0.9, P = 0.03), and the number of cases with MRI-detected EMVI was significantly increased with 1.2-CR, 3-DLR, and 1.2-DLR imaging (8.0 ± 0.0 vs 9.7 ± 0.5, 11.0 ± 2.2, and 12.3 ± 1.7, respectively; P = 0.02). For the diagnosis of histopathologic extramural tumor spread, 3-CR and 1.2-CR had significantly higher specificity than 3-DLR and 1.2-DLR imaging (0.75 and 0.78 vs 0.64 and 0.58, respectively; P = 0.02), and only 1.2-CR had significantly higher accuracy than 3-CR imaging (0.83 vs 0.79, P = 0.01). The accuracy of MRI-detected EMVI with reference to pathological EMVI was significantly lower for 3-CR and 3-DLR compared with 1.2-CR (0.77 and 0.74 vs 0.85, respectively; P < 0.01), and was not significantly different between 1.2-CR and 1.2-DLR (0.85 vs 0.80). Using any pathological venous invasion as the reference standard, the accuracy of MRI-detected EMVI was significantly the highest with 1.2-DLR, followed by 1.2-CR, 3-CR, and 3-DLR (0.71 vs 0.67 vs 0.59 vs 0.56, respectively; P < 0.01). The signal-to-noise ratio was significantly highest with 3-DLR imaging (P < 0.05). There were no significant differences in tumor-to-muscle contrast between the 4 types of PROPELLER imaging. CONCLUSIONS: Ultra-high-resolution PROPELLER T2-weighted imaging of the rectum combined with DLR improved image quality, increased the number of cases with MRI-detected extramural tumor spread and EMVI, but did not improve diagnostic accuracy with respect to pathology in rectal cancer, possibly because of false-positive MRI findings or false-negative pathologic findings.

4.
Eur J Radiol Open ; 11: 100519, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37609047

RESUMO

Purpose: To assess the feasibility of the 6-point Dixon method for evaluating liver masses. We also report our initial experience with the quantitative values in various liver masses on a 3T system. Materials and methods: Of 251 consecutive patients for whom 6-point Dixon was employed in abdominal magnetic resonance imaging scans between October 2020 and October 2021, 117 nodules in 117 patients with a mass diameter of more than 1 cm were included in the study. Images for measuring the proton density fat fraction (PDFF) and R2 * values were obtained using the iterative decomposition of water and fat with echo asymmetry and least-squares estimation-quantitative technique for liver imaging. Two radiologists independently measured PDFF (%) and R2 * (Hz). Inter-reader agreement and the differences between readers were examined using intra-class correlation coefficient (ICC) and the Bland-Altman method, respectively. PDFF and R2 * values in differentiating liver masses were examined. Results: The masses included hepatocellular carcinoma (n = 59), cyst (n = 20), metastasis (n = 14), hemangioma (n = 8), and others (n = 16). The ICCs for the region of interest (mm2), PDFF, and R2 * were 0.988 (95 % confidence interval (CI): 0.983, 0.992), 0.964 (95 % CI: 0.949, 0.975), and 0.962 (95 % CI: 0.941, 0.975), respectively. The differences of measurements between the readers showed that 5.1 % (6/117) and 6.0% (7/117) for PDFF and R2 * , respectively, were outside the 95 % CI. Conclusion: Our observation indicates that the 6-point Dixon method is applicable to liver masses.

5.
Eur J Radiol ; 150: 110271, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35334243

RESUMO

PURPOSE: A newly developed Adaptive Image Receive (AIR) coil is designed to be more flexible to conform to the human body habitus, and may improve image quality by reducing the distance between the coil element and the imaging subject. This study evaluated the AIR coil's usefulness for liver MR imaging at 3.0 T in comparison with that of a conventional coil retrospectively. METHOD: The study population comprised 50 consecutive patients, who underwent follow-up liver MR examinations with a 3.0-T MR system using both an AIR coil and a conventional coil to evaluate hepatocellular carcinoma. Three-dimensional fat-suppressed T1-weighted gradient-echo images before and after injection of an MRI contrast agent, T2-weighted single-shot fast spin-echo (SSFSE) images, and diffusion-weighted (DW) images obtained with the AIR coil were compared with corresponding images obtained with the conventional coil. One radiologist measured signal-to-noise ratios (SNRs), while two other radiologists used a 3-point scale to independently assess subjective image noise, artifacts, signal uniformity, and overall image quality. RESULTS: SNRs for the AIR coil were significantly higher than those for the conventional coil (P <.05). Subjective image noise for the AIR coil on pre- and postcontrast T1-weighted and DW images was lower than for the conventional coil for both readers (P <.05). Overall image quality on pre- and postcontrast T1-weighted and DW images for the AIR coil was better than that for the conventional coil for at least one reader (P <.05). CONCLUSIONS: In comparison with the conventional coil, AIR coil improved SNR and image quality of liver MR imaging.


Assuntos
Neoplasias Hepáticas , Imageamento por Ressonância Magnética , Humanos , Aumento da Imagem/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Estudos Retrospectivos , Tecnologia
6.
Diagnostics (Basel) ; 10(8)2020 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-32751723

RESUMO

BACKGROUND: We evaluated the feasibility of the reduced field-of-view (rFOV) diffusion-weighted imaging (DWI) with computed DWI technique by comparison and analysis of the inter-method agreement among acquired rFOV DWI (rFOVA), rFOV DWI with computed DWI technique (rFOVS), and dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) in patients with breast cancer. METHODS: A total of 130 patients with biopsy-proven breast cancers who underwent breast MRI from April 2017 to December 2017 were included in this study. The rFOVS were reformatted by calculation of the apparent diffusion coefficient curve obtained from rFOVA b = 0 s/mm2 and b = 500 s/mm2. Visual assessment of the image quality of rFOVA b = 1000 s/mm2, rFOVS, and DCE MRI was performed using a four-point grading system. Morphologic analyses of the index cancer was performed on rFOVA, rFOVS, and DCE MRI. The signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and contrast of tumor-to-parenchyma (TPC) were calculated. RESULTS: Image quality scores with rFOVA, rFOVS, and DCE MRI were not significantly different (p = 0.357). Lesion analysis of shape, margin, and size of the index cancer also did not show significant differences among the three sequences (p = 0.858, p = 0.242, and p = 0.858, respectively). SNR, CNR, and TPC of DCE MRI were significantly higher than those of rFOVA and rFOVS (p < 0.001, p = 0.001, and p = 0.016, respectively). Significant differences were not found between the SNR, CNR, and TPC of rFOVA and those of rFOVS (p > 0.999, p > 0.999, and p > 0.999, respectively). CONCLUSION: The rFOVA and rFOVS showed nearly equivalent levels of image quality required for morphological analysis of the tumors and for lesion conspicuity compared with DCE MRI.

7.
Invest Radiol ; 53(4): 191-199, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29084013

RESUMO

OBJECTIVE: The aim of this study was to evaluate the efficacy of multiphasic hepatic arterial phase (HAP) imaging using DISCO (differential subsampling with Cartesian ordering) in increasing the confidence of diagnosis of hepatocellular carcinoma (HCC). MATERIALS AND METHODS: This retrospective study was approved by the institutional review board, and the requirement for informed patient consent was waived. Consecutive patients (from 2 study periods) with malignant liver nodules were examined by gadoxetic acid-enhanced magnetic resonance imaging using either multiphasic (6 phases; n = 135) or single (n = 230) HAP imaging, which revealed 519 liver nodules other than benign ones (HCC, 497; cholangiocarcinoma, 11; metastases, 10; and malignant lymphoma, 1). All nodules were scored in accordance with the Liver Imaging Reporting and Data System (LI-RADS v2014), with or without consideration of ring-like enhancement in multiphasic HAP images as a major feature. RESULTS: In the multiphasic HAP group, 178 of 191 HCCs were scored as LR-3 to LR-5 (3 [1.69%], 85 [47.8%], and 90 [50.6%], respectively). Upon considering ring-like enhancement in multiphasic HAP images as a major feature, 5 more HCCs were scored as LR-5 (95 [53.4%]), which was a significantly more confident diagnosis than that with single HAP images (295 of 306 HCCs scored as LR-3 to LR-5: 13 [4.41%], 147 [49.8%], and 135 [45.8%], respectively; P = 0.0296). There was no significant difference in false-positive or false-negative diagnoses between the multiphasic and single HAP groups (P = 0.8400 and 0.1043, respectively). CONCLUSIONS: Multiphasic HAP imaging can improve the confidence of diagnosis of HCCs in gadoxetic acid-enhanced magnetic resonance imaging.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Gadolínio DTPA , Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Idoso , Idoso de 80 Anos ou mais , Carcinoma Hepatocelular/patologia , Meios de Contraste , Feminino , Artéria Hepática/diagnóstico por imagem , Artéria Hepática/patologia , Humanos , Neoplasias Hepáticas/patologia , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos
8.
Jpn J Radiol ; 35(8): 463-471, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28540464

RESUMO

PURPOSE: This study aimed to compare the detectability of neoplastic lesion enhancement after gadolinium-based contrast media injection in three-dimensional T1-weighted black blood Cube (3D-T1W BB Cube) and three-dimensional T1-weighted fast spoiled gradient-echo (3D-T1W fast SPGR) images obtained with 1.5-T magnetic resonance imaging (MRI). MATERIALS AND METHODS: Phantom and clinical studies were performed to compare the lesion detectability and contrast ratio (CR) between 3D-T1W BB Cube and 3D-T1W fast SPGR pulse sequences. RESULTS: In the phantom study, the CRs for 3D-T1W BB Cube and 3D-T1W fast SPGR were equivalent at low gadolinium concentrations (0.125-1.25 mmol/l). In the clinical study, the detectability in the two modalities was similar for enhanced lesions ≥5 mm, but was significantly better in 3D-T1W BB Cube for lesions <5 mm (p = 0.011). Similarly, the CRs in both modalities were similar for lesions ≥5 mm (0.66 ± 0.36 vs. 0.56 ± 0.30, p = 0.153), but significantly lower in 3D-T1W BB Cube images for lesions <5 mm (0.29 ± 0.19 vs. 0.39 ± 0.21, p = 0.006). CONCLUSIONS: Contrast 3D-T1W BB Cube imaging appears more sensitive than 3D-T1W fast SPGR imaging for detecting neoplastic lesion enhancement in the clinical setting using a 1.5-T MRI scanner, particularly for lesions <5 mm in diameter.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Gadolínio , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Sensibilidade e Especificidade
9.
J Magn Reson Imaging ; 46(2): 595-603, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28152259

RESUMO

PURPOSE: To assess the performance of four-dimensional phase-contrast vastly undersampled isotropic projection reconstruction (4D PC-VIPR) at 3.0T in depicting intrarenal arteries compared with computed tomography angiography (CTA), and its correlation with arterial flowmetry in comparison with Doppler ultrasonography (DUS). MATERIALS AND METHODS: In our prospective single-arm study, subjects were 25 patients who underwent renal transplant-related surgery at our hospital between July 2011 and June 2015. In the morphological study, depictions of renal artery branches delineated by magnetic resonance angiography (MRA)/4D PC-VIPR without gadolinium contrast agent were compared in seven living transplant recipients with the same kidney delineated by CTA in seven living transplant donors. In the flowmetric study, flow velocities in the renal (main stem), segmental, and interlobar arteries during systole and diastole were measured in 12 recipients using noncontrast MRA/4D PC-VIPR, and were compared with those obtained from DUS. RESULTS: Concerning MRA, average confidence levels of delineation rated by six observers for secondary to third level renal artery branches were 82.9-100% and for the fourth to fifth branches were 60.8-89.7% (average kappa value of 0.588 [95% confidence interval: 0.522-0.653]). Total flow velocities measured using 4D PC-VIPR and DUS demonstrated significant correlations during both systole and diastole with acceptable bias (r = 0.902; P < 0.001 in systole and r = 0.734; P < 0.001 in diastole). CONCLUSION: 4D PC-VIPR was useful in generating both morphological and hemodynamic information for evaluation of transplant intrarenal arteries without the need for contrast media. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 2 J. MAGN. RESON. IMAGING 2017;46:595-603.


Assuntos
Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Rim/diagnóstico por imagem , Artéria Renal/diagnóstico por imagem , Insuficiência Renal/diagnóstico por imagem , Ultrassonografia Doppler , Adulto , Idoso , Velocidade do Fluxo Sanguíneo , Meios de Contraste/química , Feminino , Gadolínio/química , Hemodinâmica , Humanos , Aumento da Imagem , Interpretação de Imagem Assistida por Computador , Transplante de Rim , Angiografia por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Insuficiência Renal/cirurgia , Reprodutibilidade dos Testes , Fatores de Tempo , Tomografia Computadorizada por Raios X , Transplantados
10.
Magn Reson Imaging ; 34(4): 545-51, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26747408

RESUMO

PURPOSE: To prospectively evaluate the efficacy of a new three-dimensional gradient-echo sequence (Turbo LAVA) that uses undersampled k-space acquisition combined with a two-dimensional parallel imaging technique for hepatobiliary MRI. MATERIALS AND METHODS: Sixty patients underwent T1-weighted gadoxetic acid-enhanced hepatobiliary axial MRI during a single breath-hold using both Turbo LAVA (thickness/interval=1.6/0.8mm) and conventional three-dimensional gradient-echo (4/2mm; LAVA) sequences at 3T. Axial 4-mm-thick reformation was performed from Turbo LAVA images. Portal vein-to-liver contrast (PLC), bile duct-to-liver contrast (BLC), and lesion-to-liver contrast (LLC) were compared. Two radiologists independently assessed image quality using a five-point scale. Sagittal 4-mm-thick multiplanar reconstructions (MPR) were performed from both sequences and assessed together with directly obtained 4-mm-thick sagittal LAVA images in terms of sharpness. The paired t-test was used to compare PLC, BLC, and LLC. The Wilcoxon signed rank test was used to compare five-point scales. RESULTS: The mean PLC (P<0.001), BLC (P<0.001), and LLC (P<0.005) were significantly higher for Turbo LAVA than for LAVA; the scores for image noise and sharpness were inferior (P=0.000 and 0.005) and superior (0.005 and 0.157) for Turbo LAVA. There were no significant differences in the scores for bile duct visualization, artifacts, fat suppression quality, overall quality, and focal lesion conspicuity. For sagittal images, MPR Turbo LAVA showed significantly better sharpness than MPR LAVA but showed significantly worse sharpness compared with directly obtained LAVA. CONCLUSION: High-spatial-resolution single-breath-hold hepatobiliary MRI using Turbo LAVA was feasible. Diagnostic-quality MPR images can be obtained using this sequence.


Assuntos
Ductos Biliares/diagnóstico por imagem , Gadolínio DTPA/química , Aumento da Imagem , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Suspensão da Respiração , Meios de Contraste/química , Feminino , Humanos , Imageamento Tridimensional , Hepatopatias/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
11.
Eur Radiol ; 25(11): 3175-86, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25929942

RESUMO

OBJECTIVES: The purpose of this study was to investigate the usefulness of T1W black-blood Cube (BB Cube) and T1W BB Cube fluid-attenuated inversion recovery (BB Cube-FLAIR) sequences for contrast-enhanced brain imaging, by evaluating flow-related artefacts, detectability, and contrast ratio (CR) of intracranial lesions among these sequences and T1W-SE. METHODS: Phantom studies were performed to determine the optimal parameters of BB Cube and BB Cube-FLAIR. A clinical study in 23 patients with intracranial lesions was performed to evaluate the usefulness of these two sequences for the diagnosis of intracranial lesions compared with the conventional 2D T1W-SE sequence. RESULTS: The phantom study revealed that the optimal parameters for contrast-enhanced T1W imaging were TR/TE = 500 ms/minimum in BB Cube and TR/TE/TI = 600 ms/minimum/300 ms in BB Cube-FLAIR imaging. In the clinical study, the degree of flow-related artefacts was significantly lower in BB Cube and BB Cube-FLAIR than in T1W-SE. Regarding tumour detection, BB Cube showed the best detectability; however, there were no significant differences in CR among the sequences. CONCLUSIONS: At 1.5 T, contrast-enhanced BB Cube was a better imaging sequence for detecting brain lesions than T1W-SE or BB Cube-FLAIR. KEY POINTS: • Cube is a single-slab 3D FSE imaging sequence. • We applied a black-blood (BB) imaging technique to T1W Cube. • At 1.5 T, contrast-enhanced T1W BB Cube was valuable for detecting brain lesions.


Assuntos
Neoplasias Encefálicas/diagnóstico , Meios de Contraste , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Encéfalo/anatomia & histologia , Neoplasias Encefálicas/secundário , Circulação Cerebrovascular/fisiologia , Imagem de Difusão por Ressonância Magnética/métodos , Feminino , Gadolínio DTPA , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas
12.
BMC Res Notes ; 7: 527, 2014 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-25125076

RESUMO

BACKGROUND: New imaging modalities to assess the efficacy of drugs that have molecular targets remain under development. Here, we describe for the first time the use of time-resolved three-dimensional phase-contrast magnetic resonance imaging to monitor changes in blood supply to a tumor during sunitinib treatment in a patient with localized renal cell carcinoma. CASE PRESENTATION: A 43-year-old Japanese woman with a tumor-bearing but functional single kidney presented at our hospital in July 2012. Computed tomography and magnetic resonance imaging revealed a cT1aN0M0 renal cell carcinoma embedded in the upper central region of the left kidney. She was prescribed sunitinib as neoadjuvant therapy for 8 months, and then underwent partial nephrectomy. Tumor monitoring during this time was done using time-resolved three-dimensional phase-contrast magnetic resonance imaging, a recent technique which specifically measures blood flow in the various vessels of the kidney. This imaging allowed visualization of the redistribution of renal blood flow during treatment, and showed that flow to the tumor was decreased and flows to other areas increased. Of note, this change occurred in the absence of any change in tumor size. CONCLUSION: The ability of time-resolved three-dimensional phase-contrast magnetic resonance imaging to provide quantitative information on blood supply to tumors may be useful in monitoring the efficacy of sunitinib treatment.


Assuntos
Carcinoma de Células Renais/irrigação sanguínea , Carcinoma de Células Renais/tratamento farmacológico , Imageamento Tridimensional , Neoplasias Renais/irrigação sanguínea , Neoplasias Renais/tratamento farmacológico , Imageamento por Ressonância Magnética , Circulação Renal , Adulto , Carcinoma de Células Renais/cirurgia , Meios de Contraste , Feminino , Humanos , Indóis/uso terapêutico , Neoplasias Renais/cirurgia , Nefrectomia , Pirróis/uso terapêutico , Sunitinibe , Fatores de Tempo
13.
Abdom Imaging ; 39(4): 694-701, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24562726

RESUMO

PURPOSE: To investigate optimal flip angle (FA) of three-dimensional fat-suppressed T1-weighted image on Gd-EOB-DTPA-enhanced MRI. METHODS: Forty-five patients with 35 hepatocellular carcinomas (HCCs) and 16 liver metastases (METs) were investigated. Signal-to-noise ratio (SNR), tumor-to-liver contrast (TLC) of HCC and MET, visual image quality (IQ) and lesion conspicuity (LeCo) were evaluated at hepatobiliary phase with different FAs (FA15°-30°-45°-60° in 13 patients, FA5°-10°-15°-20°-25° in 32 patients). RESULTS: TLC gradually showed better in range from FA15° to FA60° and FA5° to FA25°, but SNRs gradually decreased. SNR and TLC-MET at FA15° were significantly better than those at FA45° and FA60°. SNR at FA10° was significantly higher than at FA5°, FA20°, and FA25°. TLC-HCC and TLC-MET at FA5° were inferior to other FAs. IQs and LeCos at FA15° and FA30° were superior to those at FA45° and FA60°. IQs at FA5° and FA25° were significantly lower than those at FA10°-20°, although LeCos for HCC and MET at FA25° were superior to those at FA5°-20°. CONCLUSIONS: FA ranging from 10° to 20° is suitable for hepatobiliary phase of Gd-EOB-DTPA-enhanced MRI, to image HCC and MET.


Assuntos
Carcinoma Hepatocelular/diagnóstico , Gadolínio DTPA , Aumento da Imagem , Processamento de Imagem Assistida por Computador , Neoplasias Hepáticas/diagnóstico , Imageamento por Ressonância Magnética , Idoso , Idoso de 80 Anos ou mais , Carcinoma Hepatocelular/patologia , Carcinoma Hepatocelular/secundário , Meios de Contraste , Feminino , Humanos , Fígado/patologia , Neoplasias Hepáticas/patologia , Neoplasias Hepáticas/secundário , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA