Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 79(1): 46-51, 2023 Jan 20.
Artigo em Japonês | MEDLINE | ID: mdl-36418062

RESUMO

Confirmation of patient information is required to ensure the safety of radiation therapy. The purpose of this study was to construct a system that facilitates radiation therapy operations by linking a radiation therapy information system to a smartphone. By linking a smartphone to a radiation therapy operation support system, without using a PC terminal, we were able to input information about the patient's position and fixation into images taken with a smartphone. In addition, patient information could be directly linked into the radiation therapy information system. In addition, patient information could be verified in the irradiation room by synchronizing the smartphone with the radiation therapy support system. The questionnaire was highly evaluated in terms of radio reception, usability, visibility and barcode reading. In this study, by linking a smartphone to a radiotherapy information system, it was possible to construct a system that facilitates radiotherapy operations by checking and registering patient information at hand.


Assuntos
Radiocirurgia , Smartphone , Humanos , Inquéritos e Questionários , Extremidade Superior
2.
Anticancer Res ; 41(11): 5793-5802, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34732453

RESUMO

BACKGROUND/AIM: To evaluate the incidence and grade of radiation pneumonitis after volumetric modulated arc therapy (VMAT) performed for the treatment of non-small cell cancer (NSCLC). PATIENTS AND METHODS: Fifty consecutive non-surgical candidates with NSCLC underwent VMAT. Thirty-five patients had stage-III tumors and 15 had recurrent tumors. The prescribed radiation dose for the gross tumor and the elective nodal area was 69 Gy in 30 fractions and 51 Gy in 30 fractions, respectively. RESULTS: Radiation pneumonitis developed in 38 patients (76%, 38/50), and grade ≥2 radiation pneumonitis developed in 11 patients (22%, 11/50). The percentage of lung volume that received a dose in excess of 5 Gy (V5), V10, V20, V30, and the mean lung dose (MLD) in the bilateral and ipsilateral lung were significantly associated with the development of grade ≥2 radiation pneumonitis. CONCLUSION: The incidence and degree of radiation pneumonitis are acceptable following treatment of NSCLC with VMAT.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/radioterapia , Neoplasias Pulmonares/radioterapia , Pneumonite por Radiação/epidemiologia , Radioterapia de Intensidade Modulada/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Carcinoma Pulmonar de Células não Pequenas/patologia , Feminino , Humanos , Incidência , Japão/epidemiologia , Neoplasias Pulmonares/patologia , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Estudos Prospectivos , Doses de Radiação , Pneumonite por Radiação/diagnóstico , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
3.
Artigo em Japonês | MEDLINE | ID: mdl-34544920

RESUMO

PURPOSE: For whole-breast irradiation after breast-conserving surgery, computed tomography simulation (CTS) and irradiation are generally performed during free breathing. In treatment planning, there are three techniques: field-in-field (FIF), physical wedge (PW), and enhanced dynamic wedge (EDW). The aim of this study was to investigate the impact of respiratory motion on doses for these three irradiation techniques. METHODS: All doses were measured using an ionization chamber in a cylindrical phantom on a respiratory motion platform. Doses for each technique were measured with and without phantom motion. The dose without phantom motion was defined as the reference. The reference was compared to the dose with the phantom motion. The positions of the isocenter with respect to the ranges of phantom motion were set as exhale and intermediate. The phantom motion amplitude was set to 5 mm or 10 mm. The respiratory phase to initiate irradiation was varied as inhale, intermediate-inhale, exhale and intermediate-exhale. RESULTS: When the motion amplitude was 10 mm, the dose differences for the FIF, PW, and EDW techniques were 4.2%, 0.5%, and 0.8%, respectively, at the maximum. However, the dose difference for the FIF technique was -0.5% when the isocenter position was set to the intermediate phase of phantom motion. CONCLUSION: We found that the dose difference per fraction was reduced when the respiratory phase during CTS image acquisition was set to the intermediate phase. Meanwhile, the dose differences per fraction for the PW and EDW techniques were less affected by the respiratory motion.


Assuntos
Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Mastectomia Segmentar , Movimento (Física) , Imagens de Fantasmas , Dosagem Radioterapêutica , Respiração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA