Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Pept Res ; 61(3): 109-21, 2003 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-12558946

RESUMO

The resolution of several structurally related synthetic peptides, derived from the loop 3 region of the activin betaA-betaD subunits, has been studied using capillary electrochromatography (CEC) with Hypersil n-octadecylsilica as the sorbent. The results confirm that the CEC migration of these peptides can be varied in a charge-state-specific manner as the properties of the background electrolyte, such as pH, salt concentration and content of organic modifier, or temperature are systematically changed. Acidic peptides followed similar trends in retention behaviour, which was distinctly different to that shown by more basic peptides. The CEC separation of these peptides with the Hypersil n-octadecyl-silica involved distinguishable contributions from both electrophoretic mobility and chromatographic retention. Temperature effects were reflected as variations in both the electro-osmotic flow and the electrophoretic mobility of the peptides. When the separation forces acting on the peptides were synergistic with the electro-osmotic flow, as, for example, with the positively charged peptides at a particular pH and buffer electrolyte composition, their retention coefficient, kappacec, decreased with increasing capillary temperature, whereas when the separation forces worked in opposite directions, as for example with negatively charged peptides, their kappacec values increased slightly with increasing temperature. Moreover, when the content of organic modifier, acetonitrile, was sufficiently high, e.g. > 40% (v/v) and nonpolar interactions with the Hypersil n-octadecyl-silica sorbent were suppressed, mixtures of both the basic and acidic synthetic peptides could be baseline resolved under isocratic conditions by exploiting the mutual processes of electrophoretic mobility and electrostatic interaction. A linear relationship between the ln kappacec values and the volume fractions, psi, of the organic modifier over a limited range of psi-values, was established for the negatively charged peptides under these isocratic conditions. These findings thus provide useful guidelines in a more general context for the resolution and analysis of structurally related synthetic peptides using CEC methods.


Assuntos
Eletroforese Capilar/métodos , Subunidades beta de Inibinas/química , Peptídeos/química , Sequência de Aminoácidos , Cromatografia/métodos , Cromatografia Líquida de Alta Pressão , Relação Dose-Resposta a Droga , Eletrólitos/farmacologia , Concentração de Íons de Hidrogênio , Cinética , Dados de Sequência Molecular , Estrutura Secundária de Proteína , Estrutura Terciária de Proteína , Homologia de Sequência de Aminoácidos , Solventes/farmacologia , Temperatura , Fatores de Tempo
2.
J Pept Res ; 59(4): 159-73, 2002 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-11981956

RESUMO

In this study, we describe the application of a new analytical procedure based on capillary electrochromatographic(CEC) techniques for the characterization of different basic and acidic peptides using isocratic eluent conditions containing acetonitrile and ammonium acetate buffers of different molarities between pH 3.8 and 5.2. In particular,10 immunogenic peptide analogs with isoelectric points ranging from 3.7 to 10.1 were investigated; nine of these peptides, 1-9, were truncated analogs of the parent peptide, 10, which is a peptidomimetic related to a HIV-1 gp120 epitope. Several of these peptides have the propensity to form alpha-helical secondary structures in solution. Electrochromatographic separations of these peptides were achieved with packed fused silica capillaries(25 cm packed length, 100 microm i.d.) containing 3 microm n-octadecylsilica particles. The influence of temperature on the CEC elution behavior of these peptides, as well as the impact of changes in the eluent composition, e.g. pH, buffer concentration and acetonitrile content, were examined. The results confirm that improvements in the resolution and analysis of synthetic peptides by CEC procedures result from the increase inelectroosmotic flow (EOF) as the temperature is increased. These findings emphasize the dominant influence of the temperature-dependent viscosity parameter, eta, on the EOF and thus on peptide resolution in CEC. Moreover, these investigations have shown that eluent properties can be specifically chosen to favor either electrophoretic mobility or chromatographic retention, with the overall CEC selectivity peptides of different sequence or composition reflecting the summated contributions from both separation mechanisms. Over the pH range 4.0-5.0, and using eluents with ionic strengths ranging from 6.2 to 15 mM ammonium acetate but containing a fixed volume fraction, psi, of acetonitrile above psi = 0.40, the CEC retention behavior of peptides 1-10 correlated with a linear relationship linking the retention coefficient, kappta(cec), and the differential frictional size-to-mass ratio parameter, Xi(fric), of these peptides. However, using eluents with a low acetonitrile content and low pH values, linear correlations were also observed between the incremental retention coefficient, Delta(Kappa)cec, and the product term [-0.66(Delta(Sigma[Xn]) log(Mi/Mj)], which links the difference in intrinsic hydrophobicities and molecular masses of two peptides, Pi and Pj. This study thus demonstrates the power of CEC procedures in the analysis of synthetic bioactive peptides and provides a general experimental framework to evaluate,using CEC procedures, the influence of the key molecular attributes of peptides on their structure-retention dependencies.Finally, these studies provide additional, practical insights into the use of CEC procedures for the analysis, resolution and biophysical characterization of closely related peptide analogs derived from solid-state peptide synthesis under conditions of different eluent composition or temperature.


Assuntos
Cromatografia/métodos , Eletroforese Capilar/métodos , Proteína gp120 do Envelope de HIV/química , Proteína gp120 do Envelope de HIV/imunologia , Peptídeos/imunologia , Peptídeos/isolamento & purificação , Sequência de Aminoácidos , Soluções Tampão , Epitopos/química , Concentração de Íons de Hidrogênio , Interações Hidrofóbicas e Hidrofílicas , Mimetismo Molecular , Dados de Sequência Molecular , Concentração Osmolar , Solventes , Temperatura , Viscosidade
3.
J Chromatogr A ; 893(2): 401-9, 2000 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-11073308

RESUMO

The influence of temperature, T, on the retention times, peak widths, peak symmetry coefficients and theoretical plate numbers of two small linear peptides, [Met5]enkephalin and [Leu5]enkephalin, has been studied with capillary electrochromatography (CEC) capillary columns of 100 microm I.D. and 250 mm packed length with a total length of 335 mm, containing 3 microm Hypersil n-octadecyl bonded silica. With increasing column temperature from 15 to 60 degrees C, the electroosmotic flow (EOF) and the column efficiencies increased, whereas the retention coefficients (Kcec) of both peptides decreased. A linear relationship was found between the EOF value and the square root of the temperature over this temperature range, with a linear regression correlation of 0.998. Non linear Van 't Hoff plots (In Kcec versus 1/T) were observed for these peptides between 15 and 60 degrees C, suggesting that a phase-transition occurred with the n-octadecyl chains bonded on the silica surface, affecting the CEC retention behaviour of these peptides. In CEC systems, the Kcec values of peptides incorporate contributions from both electrophoretic migration and chromatographic retention. Positive and negative Kcec values can, in principle, thus arise with these charged analytes. However, the Kcec values of the enkephalin peptides under all temperature conditions studied were positive with an eluent composed of water-50 mM NH4OAc/AcOH, pH 5.2-acetonitrile (5:2:3, v/v) and therefore the chromatographic component dominates the retention process with these small peptides under these conditions.


Assuntos
Cromatografia Capilar Eletrocinética Micelar/métodos , Peptídeos/isolamento & purificação , Peptídeos/química , Temperatura
4.
Rapid Commun Mass Spectrom ; 14(16): 1448-54, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-10931536

RESUMO

The successful coupling of capillary electrochromatography (CEC) to an ion trap mass spectrometer via a nanoelectrospray interface (nESI) is described. Using a conductively coated tip butted to the end of a CEC column, it was possible to obtain a stable spray without any sheath liquid being employed. Selected small peptides were separated with CEC columns (100 microm i.d./25 cm long) packed with 3 microm Hypersil C8 or C18 bonded silica particles with an eluent composed of ammonium acetate/acetonitrile. Peptide mixtures of desmopressin, peptide A, oxytocin, carbetocin and [Met(5)]-enkephalin were detected in the mid-attomole range, which is the lowest amount analyzed using CEC combined with MS detection. It was also observed that sensitivity can be compromised at higher separation voltages. We demonstrate that CEC/nESI-MS, at the current stage of development, represents one of the most sensitive systems for peptide analysis.


Assuntos
Cromatografia/métodos , Espectrometria de Massas/métodos , Peptídeos/isolamento & purificação , Sequência de Aminoácidos , Desamino Arginina Vasopressina/química , Desamino Arginina Vasopressina/isolamento & purificação , Encefalina Metionina/química , Encefalina Metionina/isolamento & purificação , Proteína Oncogênica pp60(v-src)/química , Proteína Oncogênica pp60(v-src)/isolamento & purificação , Ocitocina/análogos & derivados , Ocitocina/química , Ocitocina/isolamento & purificação , Fragmentos de Peptídeos/química , Fragmentos de Peptídeos/isolamento & purificação , Controle de Qualidade , Sensibilidade e Especificidade
5.
J Chromatogr A ; 887(1-2): 165-85, 2000 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-10961310

RESUMO

This review focuses on the current state of peptide separation by capillary electroendoosmotic chromatography (CEC). When carried out under optimised conditions, peptide separation by CEC methods represents an orthogonal and complementary technique to micro-HPLC (micro-HPLC) and high-performance capillary zone electrophoresis (HPCZE). The origin of the selectivity differences that can be achieved with these three separation techniques (CEC, micro-HPLC and HPCZE), respectively are discussed, and the current limits of performance with CEC methods documented. Peptide separations by CEC methods with n-alkyl bonded silicas or mixed-mode phases are also illustrated. The development of different variants of CEC and pressurised CEC (also commonly referred to in the literature as electrically-assisted micro-HPLC) are examined. The potential of coupling CEC systems to mass spectrometers for real-time analyses of peptides or protein digests has been examined. Several future directions for the application of this technique in phenotype/proteomic and zeomic mapping of naturally occurring peptides and proteins are highlighted.


Assuntos
Eletroforese Capilar/métodos , Peptídeos/análise , Aminoácidos/análise , Cromatografia Líquida de Alta Pressão/métodos , Peptídeos/química , Terminologia como Assunto
6.
J Chromatogr A ; 853(1-2): 263-75, 1999 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-10486734

RESUMO

The retention behaviour and selectivity of selected basic, neutral and acidic peptides have been studied by capillary electroendoosmotic chromatography (CEC) with Hypersil C8, C18, Hypersil mixed-mode, and Spherisorb C18/SCX columns, 250 (335) mm x 100 microns, packed with 3 microns particles, and eluted with mobile phases composed of acetonitrile-triethylamine-phosphoric acid (TEAP) at pH 3.0 using a Hewlett-Packard Model HP3DCE capillary electrophoresis system. The selected peptides were desmopressin (D), two analogues (A and B) of desmopressin, oxytocin (O) and carbetocin (C). The peptides eluted either before or after the electroendoosmotic flow (EOF) marker, depending on the concentration of acetonitrile used and the buffer ionic strength. The retention and selectivity of these peptides under CEC conditions were compared to their behaviour in free zone capillary electrophoresis (CZE), where the separation mode was based on the electrophoretic migration of the analytes due to their charge and Stokes radius properties. In addition, their retention behaviour in RP-HPLC was also examined. As a result, it can be concluded that the elution process of this group of synthetic peptides in CEC with a TEAP buffer at pH 3.0 is mediated by a combination of both electrophoretic migration processes and retention mechanisms involving hydrophobic as well as silanophilic interactions. This CEC method when operated with these 3 microns reversed-phase and mixed-mode sorbents with peptides is thus a hybrid of two well-known analytical methods, namely CZE and RP-HPLC. However, the retention behaviour and selectivity of the selected peptides differs significantly in the CEC mode compared to the RP-HPLC or CZE modes. Therefore this CEC method with these peptides represents an orthogonal analytical separation procedure that is complimentary to both of these alternative techniques.


Assuntos
Cromatografia/métodos , Peptídeos/análise , Dióxido de Silício/química , Cromatografia Líquida de Alta Pressão , Desamino Arginina Vasopressina/análise , Ocitocina/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA