Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Surgery ; 173(3): 855-863, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36435648

RESUMO

BACKGROUND: Mechanical circulatory support effectively treats adult cardiogenic shock. Whereas cardiogenic shock confers high mortality, acute limb ischemia is a known complication of mechanical circulatory support that confers significant morbidity. We compared our novel approach to peripheral mechanical circulatory support with a conventional femoral approach, with a focus on the incidence of acute limb ischemia. METHODS: This was a retrospective cohort study of patients treated with mechanical circulatory support between January 1, 2015 and December 5, 2021 at our institution. Patients receiving any femoral peripheral venoarterial extracorporeal membrane oxygenation were compared with those receiving minimally invasive, peripherally inserted, concomitant right and left ventricular assist devices. These included the Impella 5.0 (Abiomed, Danvers, MA) left ventricular assist device and the ProtekDuo (LivaNova, London, UK) right ventricular assist device used concomitantly (Propella) approach. The primary outcome was incidence of acute limb ischemia. The baseline patient characteristics, hemodynamic data, and post-mechanical circulatory support outcomes were collected. Fisher exact test and Wilcoxon rank sum test was used for the categorical and continuous variables, respectively. Kaplan-Meier curves and log-rank test were used to estimate overall survival probabilities and survival experience, respectively. RESULTS: Fifty patients were treated with mechanical circulatory support at our institution for cardiogenic shock, with 13 patients supported with the novel Propella strategy and 37 with peripheral venoarterial extracorporeal membrane oxygenation. The baseline characteristics, including patient organ function and medical comorbidities, were similar among the groups. Nine patients suffered mortality in ≤48 hours of mechanical circulatory support initiation and were excluded. Twenty patients (69%) suffered acute limb ischemia in the peripheral venoarterial extracorporeal membrane oxygenation group; 0 patients receiving Propella suffered acute limb ischemia (P < .001). The percentages of patients surviving to discharge in peripheral venoarterial extracorporeal membrane oxygenation and Propella groups were 24% and 69%, respectively (P = .007). CONCLUSION: Patients treated with the Propella experienced a lower incidence of acute limb ischemia compared with patients treated with peripheral venoarterial extracorporeal membrane oxygenation.


Assuntos
Oxigenação por Membrana Extracorpórea , Coração Auxiliar , Adulto , Humanos , Choque Cardiogênico/etiologia , Choque Cardiogênico/terapia , Estudos Retrospectivos , Oxigenação por Membrana Extracorpórea/efeitos adversos , Isquemia/etiologia , Isquemia/terapia , Coração Auxiliar/efeitos adversos
2.
Artif Organs ; 46(8): 1597-1607, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35261065

RESUMO

BACKGROUND: Body mass index (BMI) is an important consideration for transplant-eligible left ventricular assist device (LVAD) recipients. LVAD therapy's impact on BMI is unclear. We evaluated BMI changes in patients who underwent LVAD implantation. The association between these patients' BMI and the transplant was studied. METHODS: This was a retrospective cohort study of patients who underwent LVAD implantation between January 1, 2012 and December 31, 2018 at our institution. Patients were stratified by preoperative BMI (kg/m2 ) into four groups: <30, 30-34.9, 34.9-39.9, and ≥40. BMI data were collected at 12 and 6 months prior to implantation, time of implantation, and 3- and 6- months postimplantation. RESULTS: A total of 107 patients underwent LVAD implantation at our institution. Data were available for 80 patients. Baseline characteristics included a mean age of 56.0 years, 69% male, and a mean implant BMI of 29.9 ± 6.8 kg/m2 . The mean BMI (kg/m2 ) for each of the BMI (kg/m2 ) groups <30, 30-34.9, 35-39.9, and ≥40 (n = 60, 25, 12, and 10, respectively) was 25.1, 32.5, 36.8, and 43.8, respectively. There was no consistent pattern with weight change across differing implant BMIs. No patient with a BMI of <30 gained sufficient weight to impact transplant candidacy. Twenty-three percent of patients with a BMI of 30-34.9 kg/m2 , 60% of patients with a BMI of 35-39.9 kg/m2 , and 87.5% of patients with a BMI of ≥40 kg/m2 had a 6-month BMI potentially affecting transplant. CONCLUSIONS: Associated weight changes during LVAD support may significantly impact transplant candidacy. Higher BMI groups may benefit from multimodal and multidisciplinary targeted weight-loss interventions.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Índice de Massa Corporal , Feminino , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA