Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Sex Med ; 10(3): 100517, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35461065

RESUMO

BACKGROUND: Collagenase Clostridium histolyticum (CCH), which was approved by the FDA for the treatment of Peyronie's disease (PD) in 2013, may obviate the need for surgery but its historically high cost must be considered when offering CCH vs surgical intervention to affected patients. AIM: To compare trends of intralesional injections vs surgical treatment for PD and assess the contemporary cost of treatment with CCH vs surgical intervention. METHODS: We reviewed 2009-2019 MarketScan Commercial Claims data to identify all men 18 years and older with PD. CPT and HCPCS codes were used to identify PD treatments for each patient. Associated insurance claims in USD were summed for each treatment type. OUTCOMES: Total and out-of-pocket costs, as well as frequencies, for treatments were calculated on a yearly basis and the Cochran-Armitage test was used to compare frequencies before and after FDA approval of CCH. RESULTS: Of 89,205 men diagnosed with PD, 21,605 (24.2%) underwent treatment; most required only intralesional injections, however 1,519 (7.0%) received only surgical therapy and 1,951 (9.0%) required medical and surgical therapy. Intralesional CCH use sharply increased after its FDA-approval in 2013 with a concomitant fall of intralesional verapamil use. The use of both surgical plication and plaque grafting decreased steadily from 2009 to 2019. The median cost per patient for all 3 treatments increased over the study time-period: $1,856 to $3,196 for plication, $2,233 to $3,631 for plaque grafting, and $6,940 to $8,895 per cycle for CCH. Out-of-pocket median patient contribution for plication, plaque grafting, and per cycle intralesional CCH injection were similar over the study period and never exceeded $300. CLINICAL IMPLICATIONS: CCH is significantly more expensive than any surgical treatment option, however, the out-of-pocket patient contribution for surgery and CCH are similar. STRENGTHS & LIMITATIONS: This study incorporated all procedure costs and is the most contemporary, comprehensive, and accurate reflection of overall and out-of-pocket costs to patients for surgical and intralesional PD therapies. We anticipate these data to allow for a more complete discussion between patients and providers regarding their care. The use of a commercial claims database prohibited assessment of post-procedural costs and treatment outcomes. CONCLUSION: CCH use has increased significantly since its FDA approval in 2013 with out-of-pocket patient contribution comparable to surgical therapy despite significantly higher total treatment costs. Walton EL, Quinn TP, Mulloy E, et al. Cost of Intralesional Collagenase Clostridium Histiolyticum Therapy Versus Surgery for the Management of Peyronie's Disease: A Claims-Based Analysis (2009-2019). Sex Med 2022;10:100517.

2.
Cancer Med ; 8(8): 3659-3665, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31111654

RESUMO

PURPOSE: Magnetic resonance imaging is playing an ever-bigger role in the management of prostate cancer. This study investigated barriers to obtaining multi-parametric MRI (mpMRI) in African-American men on active surveillance for prostate cancer in comparison to white men affected by the same type of cancer. MATERIALS AND METHODS: Retrospective review of prostate mpMRI orders from August 2015 to October 2017 at a single health organization treating a diverse population was performed. Data was extracted from the electronic medical records and cancellations were examined based on the documented reason for mpMRI cancellation, race, median zip code household income, and distance from healthcare facility. RESULTS: Out of 793 prostate mpMRI orders, 201 (25%) went unscanned. Access to care issues accounted for 46% of unscanned orders. Patient cancellations were the most common, followed by difficulty contacting patients, and insurance denials. African-American patients disproportionately went unscanned because institution staff were unable to contact patients (29% vs 10% in white men, P = 0.0015). Median zip code household income was significantly different between racial groups but did not vary between indication for cancellation. CONCLUSIONS: African-American prostate cancer patients' access to mpMRI is hindered more by barriers to care than White patients. Urology providers must consider these issues before using prostate mpMRI within their active surveillance pathways.


Assuntos
Negro ou Afro-Americano , Acessibilidade aos Serviços de Saúde , Imageamento por Ressonância Magnética , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/epidemiologia , Conduta Expectante , Adulto , Idoso , Idoso de 80 Anos ou mais , Etnicidade , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Vigilância em Saúde Pública , Estudos Retrospectivos
3.
Lab Chip ; 14(12): 2023-32, 2014 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-24763966

RESUMO

We report two 3D printed devices that can be used for electrochemical detection. In both cases, the electrode is housed in commercially available, polymer-based fittings so that the various electrode materials (platinum, platinum black, carbon, gold, silver) can be easily added to a threaded receiving port printed on the device; this enables a module-like approach to the experimental design, where the electrodes are removable and can be easily repolished for reuse after exposure to biological samples. The first printed device represents a microfluidic platform with a 500 × 500 µm channel and a threaded receiving port to allow integration of either polyetheretherketone (PEEK) nut-encased glassy carbon or platinum black (Pt-black) electrodes for dopamine and nitric oxide (NO) detection, respectively. The embedded 1 mm glassy carbon electrode had a limit of detection (LOD) of 500 nM for dopamine and a linear response (R(2) = 0.99) for concentrations between 25-500 µM. When the glassy carbon electrode was coated with 0.05% Nafion, significant exclusion of nitrite was observed when compared to signal obtained from equimolar injections of dopamine. When using flow injection analysis with a Pt/Pt-black electrode and standards derived from NO gas, a linear correlation (R(2) = 0.99) over a wide range of concentrations (7.6-190 µM) was obtained, with the LOD for NO being 1 µM. The second application showcases a 3D printed fluidic device that allows collection of the biologically relevant analyte adenosine triphosphate (ATP) while simultaneously measuring the release stimulus (reduced oxygen concentration). The hypoxic sample (4.8 ± 0.5 ppm oxygen) released 2.4 ± 0.4 times more ATP than the normoxic sample (8.4 ± 0.6 ppm oxygen). Importantly, the results reported here verify the reproducible and transferable nature of using 3D printing as a fabrication technique, as devices and electrodes were moved between labs multiple times during completion of the study.


Assuntos
Dopamina/análise , Técnicas Eletroquímicas , Técnicas Analíticas Microfluídicas , Óxido Nítrico/análise , Impressão Tridimensional , Técnicas Eletroquímicas/instrumentação , Técnicas Eletroquímicas/métodos , Eletrodos , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Oxigênio/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA