Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Healthcare (Basel) ; 10(12)2022 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-36553906

RESUMO

According to the Health Promotion Administration in the Ministry of Health and Welfare statistics in Taiwan, over ten thousand women have breast cancer every year. Mammography is widely used to detect breast cancer. However, it is limited by the operator's technique, the cooperation of the subjects, and the subjective interpretation by the physician. It results in inconsistent identification. Therefore, this study explores the use of a deep neural network algorithm for the classification of mammography images. In the experimental design, a retrospective study was used to collect imaging data from actual clinical cases. The mammography images were collected and classified according to the breast image reporting and data-analyzing system (BI-RADS). In terms of model building, a fully convolutional dense connection network (FC-DCN) is used for the network backbone. All the images were obtained through image preprocessing, a data augmentation method, and transfer learning technology to build a mammography image classification model. The research results show the model's accuracy, sensitivity, and specificity were 86.37%, 100%, and 72.73%, respectively. Based on the FC-DCN model framework, it can effectively reduce the number of training parameters and successfully obtain a reasonable image classification model for mammography.

2.
Sensors (Basel) ; 21(21)2021 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-34770534

RESUMO

Positron emission tomography (PET) can provide functional images and identify abnormal metabolic regions of the whole-body to effectively detect tumor presence and distribution. The filtered back-projection (FBP) algorithm is one of the most common images reconstruction methods. However, it will generate strike artifacts on the reconstructed image and affect the clinical diagnosis of lesions. Past studies have shown reduction in strike artifacts and improvement in quality of images by two-dimensional morphological structure operators (2D-MSO). The morphological structure method merely processes the noise distribution of 2D space and never considers the noise distribution of 3D space. This study was designed to develop three-dimensional-morphological structure operators (3D MSO) for nuclear medicine imaging and effectively eliminating strike artifacts without reducing image quality. A parallel operation was also used to calculate the minimum background standard deviation of the images for three-dimensional morphological structure operators with the optimal response curve (3D-MSO/ORC). As a result of Jaszczak phantom and rat verification, 3D-MSO/ORC showed better denoising performance and image quality than the 2D-MSO method. Thus, 3D MSO/ORC with a 3 × 3 × 3 mask can reduce noise efficiently and provide stability in FBP images.


Assuntos
Algoritmos , Artefatos , Animais , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons , Ratos
3.
Biosensors (Basel) ; 11(6)2021 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-34201215

RESUMO

Anesthesia assessment is most important during surgery. Anesthesiologists use electrocardiogram (ECG) signals to assess the patient's condition and give appropriate medications. However, it is not easy to interpret the ECG signals. Even physicians with more than 10 years of clinical experience may still misjudge. Therefore, this study uses convolutional neural networks to classify ECG image types to assist in anesthesia assessment. The research uses Internet of Things (IoT) technology to develop ECG signal measurement prototypes. At the same time, it classifies signal types through deep neural networks, divided into QRS widening, sinus rhythm, ST depression, and ST elevation. Three models, ResNet, AlexNet, and SqueezeNet, are developed with 50% of the training set and test set. Finally, the accuracy and kappa statistics of ResNet, AlexNet, and SqueezeNet in ECG waveform classification were (0.97, 0.96), (0.96, 0.95), and (0.75, 0.67), respectively. This research shows that it is feasible to measure ECG in real time through IoT and then distinguish four types through deep neural network models. In the future, more types of ECG images will be added, which can improve the real-time classification practicality of the deep model.


Assuntos
Eletrocardiografia , Redes Neurais de Computação , Algoritmos , Arritmias Cardíacas , Humanos , Internet das Coisas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA