Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
Diagnostics (Basel) ; 14(11)2024 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-38893655

RESUMO

The early detection of esophageal cancer presents a substantial difficulty, which contributes to its status as a primary cause of cancer-related fatalities. This study used You Only Look Once (YOLO) frameworks, specifically YOLOv5 and YOLOv8, to predict and detect early-stage EC by using a dataset sourced from the Division of Gastroenterology and Hepatology, Ditmanson Medical Foundation, Chia-Yi Christian Hospital. The dataset comprised 2741 white-light images (WLI) and 2741 hyperspectral narrowband images (HSI-NBI). They were divided into 60% training, 20% validation, and 20% test sets to facilitate robust detection. The images were produced using a conversion method called the spectrum-aided vision enhancer (SAVE). This algorithm can transform a WLI into an NBI without requiring a spectrometer or spectral head. The main goal was to identify dysplasia and squamous cell carcinoma (SCC). The model's performance was evaluated using five essential metrics: precision, recall, F1-score, mAP, and the confusion matrix. The experimental results demonstrated that the HSI model exhibited improved learning capabilities for SCC characteristics compared with the original RGB images. Within the YOLO framework, YOLOv5 outperformed YOLOv8, indicating that YOLOv5's design possessed superior feature-learning skills. The YOLOv5 model, when used in conjunction with HSI-NBI, demonstrated the best performance. It achieved a precision rate of 85.1% (CI95: 83.2-87.0%, p < 0.01) in diagnosing SCC and an F1-score of 52.5% (CI95: 50.1-54.9%, p < 0.01) in detecting dysplasia. The results of these figures were much better than those of YOLOv8. YOLOv8 achieved a precision rate of 81.7% (CI95: 79.6-83.8%, p < 0.01) and an F1-score of 49.4% (CI95: 47.0-51.8%, p < 0.05). The YOLOv5 model with HSI demonstrated greater performance than other models in multiple scenarios. This difference was statistically significant, suggesting that the YOLOv5 model with HSI significantly improved detection capabilities.

2.
Biomed Opt Express ; 15(2): 753-771, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38404333

RESUMO

This research aims to explore the potential application of this approach in the production of biosensor chips. The biosensor chip is utilized for the identification and examination of early-stage lung cancer cells. The findings of the optical microscope were corroborated by the field emission scanning electron microscopy, which provided further evidence that the growth of MoS2 is uniform and that there is minimal disruption in the electrode, hence minimizing the likelihood of an open circuit creation. Furthermore, the bilayer structure of the produced MoS2 has been validated through the utilization of Raman spectroscopy. A research investigation was undertaken to measure the photoelectric current generated by three various types of clinical samples containing lung cancer cells, specifically the CL1, NCI-H460, and NCI-H520 cell lines. The findings from the empirical analysis indicate that the coefficient of determination (R-Square) for the linear regression model was approximately 98%. Furthermore, the integration of a double-layer MoS2 film resulted in a significant improvement of 38% in the photocurrent, as observed in the device's performance.

3.
Cancers (Basel) ; 16(3)2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-38339322

RESUMO

Esophageal carcinoma (EC) is a prominent contributor to cancer-related mortality since it lacks discernible features in its first phases. Multiple studies have shown that narrow-band imaging (NBI) has superior accuracy, sensitivity, and specificity in detecting EC compared to white light imaging (WLI). Thus, this study innovatively employs a color space linked to décor to transform WLIs into NBIs, offering a novel approach to enhance the detection capabilities of EC in its early stages. In this study a total of 3415 WLI along with the corresponding 3415 simulated NBI images were used for analysis combined with the YOLOv5 algorithm to train the WLI images and the NBI images individually showcasing the adaptability of advanced object detection techniques in the context of medical image analysis. The evaluation of the model's performance was based on the produced confusion matrix and five key metrics: precision, recall, specificity, accuracy, and F1-score of the trained model. The model underwent training to accurately identify three specific manifestations of EC, namely dysplasia, squamous cell carcinoma (SCC), and polyps demonstrates a nuanced and targeted analysis, addressing diverse aspects of EC pathology for a more comprehensive understanding. The NBI model effectively enhanced both its recall and accuracy rates in detecting dysplasia cancer, a pre-cancerous stage that might improve the overall five-year survival rate. Conversely, the SCC category decreased its accuracy and recall rate, although the NBI and WLI models performed similarly in recognizing the polyp. The NBI model demonstrated an accuracy of 0.60, 0.81, and 0.66 in the dysplasia, SCC, and polyp categories, respectively. Additionally, it attained a recall rate of 0.40, 0.73, and 0.76 in the same categories. The WLI model demonstrated an accuracy of 0.56, 0.99, and 0.65 in the dysplasia, SCC, and polyp categories, respectively. Additionally, it obtained a recall rate of 0.39, 0.86, and 0.78 in the same categories, respectively. The limited number of training photos is the reason for the suboptimal performance of the NBI model which can be improved by increasing the dataset.

4.
Cancers (Basel) ; 16(1)2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-38201644

RESUMO

This study pioneers the application of artificial intelligence (AI) and hyperspectral imaging (HSI) in the diagnosis of skin cancer lesions, particularly focusing on Mycosis fungoides (MF) and its differentiation from psoriasis (PsO) and atopic dermatitis (AD). By utilizing a comprehensive dataset of 1659 skin images, including cases of MF, PsO, AD, and normal skin, a novel multi-frame AI algorithm was used for computer-aided diagnosis. The automatic segmentation and classification of skin lesions were further explored using advanced techniques, such as U-Net Attention models and XGBoost algorithms, transforming images from the color space to the spectral domain. The potential of AI and HSI in dermatological diagnostics was underscored, offering a noninvasive, efficient, and accurate alternative to traditional methods. The findings are particularly crucial for early-stage invasive lesion detection in MF, showcasing the model's robust performance in segmenting and classifying lesions and its superior predictive accuracy validated through k-fold cross-validation. The model attained its optimal performance with a k-fold cross-validation value of 7, achieving a sensitivity of 90.72%, a specificity of 96.76%, an F1-score of 90.08%, and an ROC-AUC of 0.9351. This study marks a substantial advancement in dermatological diagnostics, thereby contributing significantly to the early and precise identification of skin malignancies and inflammatory conditions.

5.
Int J Mol Sci ; 25(2)2024 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-38279310

RESUMO

Mitochondria are critical for providing energy to maintain cell viability. Oxidative phosphorylation involves the transfer of electrons from energy substrates to oxygen to produce adenosine triphosphate. Mitochondria also regulate cell proliferation, metastasis, and deterioration. The flow of electrons in the mitochondrial respiratory chain generates reactive oxygen species (ROS), which are harmful to cells at high levels. Oxidative stress caused by ROS accumulation has been associated with an increased risk of cancer, and cardiovascular and liver diseases. Glutathione (GSH) is an abundant cellular antioxidant that is primarily synthesized in the cytoplasm and delivered to the mitochondria. Mitochondrial glutathione (mGSH) metabolizes hydrogen peroxide within the mitochondria. A long-term imbalance in the ratio of mitochondrial ROS to mGSH can cause cell dysfunction, apoptosis, necroptosis, and ferroptosis, which may lead to disease. This study aimed to review the physiological functions, anabolism, variations in organ tissue accumulation, and delivery of GSH to the mitochondria and the relationships between mGSH levels, the GSH/GSH disulfide (GSSG) ratio, programmed cell death, and ferroptosis. We also discuss diseases caused by mGSH deficiency and related therapeutics.


Assuntos
Glutationa , Mitocôndrias , Espécies Reativas de Oxigênio/metabolismo , Glutationa/metabolismo , Mitocôndrias/metabolismo , Estresse Oxidativo/fisiologia , Homeostase , Oxirredução
6.
Cancers (Basel) ; 15(23)2023 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-38067338

RESUMO

Skin cancer, a malignant neoplasm originating from skin cell types including keratinocytes, melanocytes, and sweat glands, comprises three primary forms: basal cell carcinoma (BCC), squamous cell carcinoma (SCC), and malignant melanoma (MM). BCC and SCC, while constituting the most prevalent categories of skin cancer, are generally considered less aggressive compared to MM. Notably, MM possesses a greater capacity for invasiveness, enabling infiltration into adjacent tissues and dissemination via both the circulatory and lymphatic systems. Risk factors associated with skin cancer encompass ultraviolet (UV) radiation exposure, fair skin complexion, a history of sunburn incidents, genetic predisposition, immunosuppressive conditions, and exposure to environmental carcinogens. Early detection of skin cancer is of paramount importance to optimize treatment outcomes and preclude the progression of disease, either locally or to distant sites. In pursuit of this objective, numerous computer-aided diagnosis (CAD) systems have been developed. Hyperspectral imaging (HSI), distinguished by its capacity to capture information spanning the electromagnetic spectrum, surpasses conventional RGB imaging, which relies solely on three color channels. Consequently, this study offers a comprehensive exploration of recent CAD investigations pertaining to skin cancer detection and diagnosis utilizing HSI, emphasizing diagnostic performance parameters such as sensitivity and specificity.

7.
Sci Rep ; 13(1): 20502, 2023 11 22.
Artigo em Inglês | MEDLINE | ID: mdl-37993660

RESUMO

The clinical signs and symptoms of esophageal cancer (EC) are often not discernible until the intermediate or advanced phases. The detection of EC in advanced stages significantly decreases the survival rate to below 20%. This study conducts a comparative analysis of the efficacy of several imaging techniques, including white light image (WLI), narrowband imaging (NBI), cycle-consistent adversarial network simulated narrowband image (CNBI), and hyperspectral imaging simulated narrowband image (HNBI), in the early detection of esophageal cancer (EC). In conjunction with Kaohsiung Armed Forces General Hospital, a dataset consisting of 1000 EC pictures was used, including 500 images captured using WLI and 500 images captured using NBI. The CycleGAN model was used to generate the CNBI dataset. Additionally, a novel method for HSI imaging was created with the objective of generating HNBI pictures. The evaluation of the efficacy of these four picture types in early detection of EC was conducted using three indicators: CIEDE2000, entropy, and the structural similarity index measure (SSIM). Results of the CIEDE2000, entropy, and SSIM analyses suggest that using CycleGAN to generate CNBI images and HSI model for creating HNBI images is superior in detecting early esophageal cancer compared to the use of conventional WLI and NBI techniques.


Assuntos
Neoplasias Esofágicas , Imageamento Hiperespectral , Humanos , Detecção Precoce de Câncer , Neoplasias Esofágicas/diagnóstico por imagem , Neoplasias Esofágicas/radioterapia , Imagem de Banda Estreita , Luz
8.
Biomed Opt Express ; 14(8): 4383-4405, 2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-37799695

RESUMO

One of the leading causes of cancer deaths is esophageal cancer (EC) because identifying it in early stage is challenging. Computer-aided diagnosis (CAD) could detect the early stages of EC have been developed in recent years. Therefore, in this study, complete meta-analysis of selected studies that only uses hyperspectral imaging to detect EC is evaluated in terms of their diagnostic test accuracy (DTA). Eight studies are chosen based on the Quadas-2 tool results for systematic DTA analysis, and each of the methods developed in these studies is classified based on the nationality of the data, artificial intelligence, the type of image, the type of cancer detected, and the year of publishing. Deeks' funnel plot, forest plot, and accuracy charts were made. The methods studied in these articles show the automatic diagnosis of EC has a high accuracy, but external validation, which is a prerequisite for real-time clinical applications, is lacking.

9.
Cancers (Basel) ; 15(19)2023 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-37835409

RESUMO

Video capsule endoscopy (VCE) is increasingly used to decrease discomfort among patients owing to its small size. However, VCE has a major drawback of not having narrow band imaging (NBI) functionality. The current VCE has the traditional white light imaging (WLI) only, which has poor performance in the computer-aided detection (CAD) of different types of cancer compared to NBI. Specific cancers, such as esophageal cancer (EC), do not exhibit any early biomarkers, making their early detection difficult. In most cases, the symptoms are unnoticeable, and EC is diagnosed only in later stages, making its 5-year survival rate below 20% on average. NBI filters provide particular wavelengths that increase the contrast and enhance certain features of the mucosa, thereby enabling early identification of EC. However, VCE does not have a slot for NBI functionality because its size cannot be increased. Hence, NBI image conversion from WLI can presently only be achieved in post-processing. In this study, a complete arithmetic assessment of the decorrelated color space was conducted to generate NBI images from WLI images for VCE of the esophagus. Three parameters, structural similarity index metric (SSIM), entropy, and peak-signal-to-noise ratio (PSNR), were used to assess the simulated NBI images. Results show the good performance of the NBI image reproduction method with SSIM, entropy difference, and PSNR values of 93.215%, 4.360, and 28.064 dB, respectively.

10.
Cancers (Basel) ; 15(15)2023 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-37568599

RESUMO

Early detection of esophageal cancer through endoscopic imaging is pivotal for effective treatment. However, the intricacies of endoscopic diagnosis, contingent on the physician's expertise, pose challenges. Esophageal cancer features often manifest ambiguously, leading to potential confusions with other inflammatory esophageal conditions, thereby complicating diagnostic accuracy. In recent times, computer-aided diagnosis has emerged as a promising solution in medical imaging, particularly within the domain of endoscopy. Nonetheless, contemporary AI-based diagnostic models heavily rely on voluminous data sources, limiting their applicability, especially in scenarios with scarce datasets. To address this limitation, our study introduces novel data training strategies based on transfer learning, tailored to optimize performance with limited data. Additionally, we propose a hybrid model integrating EfficientNet and Vision Transformer networks to enhance prediction accuracy. Conducting rigorous evaluations on a carefully curated dataset comprising 1002 endoscopic images (comprising 650 white-light images and 352 narrow-band images), our model achieved exceptional outcomes. Our combined model achieved an accuracy of 96.32%, precision of 96.44%, recall of 95.70%, and f1-score of 96.04%, surpassing state-of-the-art models and individual components, substantiating its potential for precise medical image classification. The AI-based medical image prediction platform presents several advantageous characteristics, encompassing superior prediction accuracy, a compact model size, and adaptability to low-data scenarios. This research heralds a significant stride in the advancement of computer-aided endoscopic imaging for improved esophageal cancer diagnosis.

11.
J Clin Med ; 12(3)2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-36769781

RESUMO

Many studies have recently used several deep learning methods for detecting skin cancer. However, hyperspectral imaging (HSI) is a noninvasive optics system that can obtain wavelength information on the location of skin cancer lesions and requires further investigation. Hyperspectral technology can capture hundreds of narrow bands of the electromagnetic spectrum both within and outside the visible wavelength range as well as bands that enhance the distinction of image features. The dataset from the ISIC library was used in this study to detect and classify skin cancer on the basis of basal cell carcinoma (BCC), squamous cell carcinoma (SCC), and seborrheic keratosis (SK). The dataset was divided into training and test sets, and you only look once (YOLO) version 5 was applied to train the model. The model performance was judged according to the generated confusion matrix and five indicating parameters, including precision, recall, specificity, accuracy, and the F1-score of the trained model. Two models, namely, hyperspectral narrowband image (HSI-NBI) and RGB classification, were built and then compared in this study to understand the performance of HSI with the RGB model. Experimental results showed that the HSI model can learn the SCC feature better than the original RGB image because the feature is more prominent or the model is not captured in other categories. The recall rate of the RGB and HSI models were 0.722 to 0.794, respectively, thereby indicating an overall increase of 7.5% when using the HSI model.

12.
Cancers (Basel) ; 14(17)2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36077827

RESUMO

In this study, the combination of hyperspectral imaging (HSI) technology and band selection was coupled with color reproduction. The white-light images (WLIs) were simulated as narrow-band endoscopic images (NBIs). As a result, the blood vessel features in the endoscopic image became more noticeable, and the prediction performance was improved. In addition, a single-shot multi-box detector model for predicting the stage and location of esophageal cancer was developed to evaluate the results. A total of 1780 esophageal cancer images, including 845 WLIs and 935 NBIs, were used in this study. The images were divided into three stages based on the pathological features of esophageal cancer: normal, dysplasia, and squamous cell carcinoma. The results showed that the mean average precision (mAP) reached 80% in WLIs, 85% in NBIs, and 84% in HSI images. This study's results showed that HSI has more spectral features than white-light imagery, and it improves accuracy by about 5% and matches the results of NBI predictions.

13.
J Pers Med ; 12(8)2022 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-35893299

RESUMO

Early detection of esophageal cancer has always been difficult, thereby reducing the overall five-year survival rate of patients. In this study, semantic segmentation was used to predict and label esophageal cancer in its early stages. U-Net was used as the basic artificial neural network along with Resnet to extract feature maps that will classify and predict the location of esophageal cancer. A total of 75 white-light images (WLI) and 90 narrow-band images (NBI) were used. These images were classified into three categories: normal, dysplasia, and squamous cell carcinoma. After labeling, the data were divided into a training set, verification set, and test set. The training set was approved by the encoder-decoder model to train the prediction model. Research results show that the average time of 111 ms is used to predict each image in the test set, and the evaluation method is calculated in pixel units. Sensitivity is measured based on the severity of the cancer. In addition, NBI has higher accuracy of 84.724% when compared with the 82.377% accuracy rate of WLI, thereby making it a suitable method to detect esophageal cancer using the algorithm developed in this study.

14.
Biosensors (Basel) ; 12(6)2022 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-35735553

RESUMO

In this study, a biochip was fabricated using a light-absorbing layer of a silicon solar element combined with serrated, interdigitated electrodes and used to identify four different types of cancer cells: CE81T esophageal cancer, OE21 esophageal cancer, A549 lung adenocarcinoma, and TSGH-8301 bladder cancer cells. A string of pearls was formed from dielectrophoretic aggregated cancer cells because of the serrated interdigitated electrodes. Thus, cancer cells were identified in different parts, and electron-hole pairs were separated by photo-excited carriers through the light-absorbing layer of the solar element. The concentration catalysis mechanism of GSH and GSSG was used to conduct photocurrent response and identification, which provides the fast, label-free measurement of cancer cells. The total time taken for this analysis was 13 min. Changes in the impedance value and photocurrent response of each cancer cell were linearly related to the number of cells, and the slope of the admittance value was used to distinguish the location of the cancerous lesion, the slope of the photocurrent response, and the severity of the cancerous lesion. The results show that the number of cancerous cells was directly proportional to the admittance value and the photocurrent response for all four different types of cancer cells. Additionally, different types of cancer cells could easily be differentiated using the slope value of the photocurrent response and the admittance value.


Assuntos
Neoplasias Esofágicas , Silício , Impedância Elétrica , Eletrodos , Humanos , Análise de Sequência com Séries de Oligonucleotídeos
15.
Int J Mol Sci ; 23(9)2022 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-35563136

RESUMO

In this study, n-type MoS2 monolayer flakes are grown through chemical vapor deposition (CVD), and a p-type Cu2O thin film is grown via electrochemical deposition. The crystal structure of the grown MoS2 flakes is analyzed through transmission electron microscopy. The monolayer structure of the MoS2 flakes is verified with Raman spectroscopy, multiphoton excitation microscopy, atomic force microscopy, and photoluminescence (PL) measurements. After the preliminary processing of the grown MoS2 flakes, the sample is then transferred onto a Cu2O thin film to complete a p-n heterogeneous structure. Data are confirmed via scanning electron microscopy, SHG, and Raman mapping measurements. The luminous energy gap between the two materials is examined through PL measurements. Results reveal that the thickness of the single-layer MoS2 film is 0.7 nm. PL mapping shows a micro signal generated at the 627 nm wavelength, which belongs to the B2 excitons of MoS2 and tends to increase gradually when it approaches 670 nm. Finally, the biosensor is used to detect lung cancer cell types in hydroplegia significantly reducing the current busy procedures and longer waiting time for detection. The results suggest that the fabricated sensor is highly sensitive to the change in the photocurrent with the number of each cell, the linear regression of the three cell types is as high as 99%. By measuring the slope of the photocurrent, we can identify the type of cells and the number of cells.


Assuntos
Técnicas Biossensoriais , Neoplasias Pulmonares , Técnicas Biossensoriais/métodos , Humanos , Neoplasias Pulmonares/diagnóstico , Microscopia Eletrônica de Transmissão , Molibdênio/química , Análise Espectral Raman
16.
Cancers (Basel) ; 13(18)2021 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-34572819

RESUMO

This study uses hyperspectral imaging (HSI) and a deep learning diagnosis model that can identify the stage of esophageal cancer and mark the locations. This model simulates the spectrum data from the image using an algorithm developed in this study which is combined with deep learning for the classification and diagnosis of esophageal cancer using a single-shot multibox detector (SSD)-based identification system. Some 155 white-light endoscopic images and 153 narrow-band endoscopic images of esophageal cancer were used to evaluate the prediction model. The algorithm took 19 s to predict the results of 308 test images and the accuracy of the test results of the WLI and NBI esophageal cancer was 88 and 91%, respectively, when using the spectral data. Compared with RGB images, the accuracy of the WLI was 83% and the NBI was 86%. In this study, the accuracy of the WLI and NBI was increased by 5%, confirming that the prediction accuracy of the HSI detection method is significantly improved.

17.
Nanomaterials (Basel) ; 11(5)2021 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-33919216

RESUMO

P-type and N-type photoelectrochemical (PEC) biosensors were established in the laboratory to discuss the correlation between characteristic substances and photoactive material properties through the photogenerated charge carrier transport mechanism. Four types of human esophageal cancer cells (ECCs) were analyzed without requiring additional bias voltage. Photoelectrical characteristics were examined by scanning electron microscopy (SEM), X-ray diffraction (XRD), UV-vis reflectance spectroscopy, and photocurrent response analyses. Results showed that smaller photocurrent was measured in cases with advanced cancer stages. Glutathione (L-glutathione reduced, GSH) and Glutathione disulfide (GSSG) in cancer cells carry out redox reactions during carrier separation, which changes the photocurrent. The sensor can identify ECC stages with a certain level of photoelectrochemical response. The detection error can be optimized by adjusting the number of cells, and the detection time of about 5 min allowed repeated measurement.

18.
J Clin Med ; 10(1)2021 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-33406761

RESUMO

An artificial intelligence algorithm to detect mycosis fungoides (MF), psoriasis (PSO), and atopic dermatitis (AD) is demonstrated. Results showed that 10 s was consumed by the single shot multibox detector (SSD) model to analyze 292 test images, among which 273 images were correctly detected. Verification of ground truth samples of this research come from pathological tissue slices and OCT analysis. The SSD diagnosis accuracy rate was 93%. The sensitivity values of the SSD model in diagnosing the skin lesions according to the symptoms of PSO, AD, MF, and normal were 96%, 80%, 94%, and 95%, and the corresponding precision were 96%, 86%, 98%, and 90%. The highest sensitivity rate was found in MF probably because of the spread of cancer cells in the skin and relatively large lesions of MF. Many differences were found in the accuracy between AD and the other diseases. The collected AD images were all in the elbow or arm and other joints, the area with AD was small, and the features were not obvious. Hence, the proposed SSD could be used to identify the four diseases by using skin image detection, but the diagnosis of AD was relatively poor.

19.
Cancers (Basel) ; 13(2)2021 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-33477274

RESUMO

Diagnosis of early esophageal neoplasia, including dysplasia and superficial cancer, is a great challenge for endoscopists. Recently, the application of artificial intelligence (AI) using deep learning in the endoscopic field has made significant advancements in diagnosing gastrointestinal cancers. In the present study, we constructed a single-shot multibox detector using a convolutional neural network for diagnosing different histological grades of esophageal neoplasms and evaluated the diagnostic accuracy of this computer-aided system. A total of 936 endoscopic images were used as training images, and these images included 498 white-light imaging (WLI) and 438 narrow-band imaging (NBI) images. The esophageal neoplasms were divided into three classifications: squamous low-grade dysplasia, squamous high-grade dysplasia, and squamous cell carcinoma, based on pathological diagnosis. This AI system analyzed 264 test images in 10 s, and the sensitivity, specificity, and diagnostic accuracy of this system in detecting esophageal neoplasms were 96.2%, 70.4%, and 90.9%, respectively. The accuracy of this AI system in differentiating the histological grade of esophageal neoplasms was 92%. Our system showed better accuracy in diagnosing NBI (95%) than WLI (89%) images. Our results showed the great potential of AI systems in identifying esophageal neoplasms as well as differentiating histological grades.

20.
Sensors (Basel) ; 20(9)2020 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-32357418

RESUMO

A highly sensitive photoelectrochemical (PEC) biosensor without external bias was developed in this study. The biosensor was configured with a p-Cu2O and n-ZnO heterostructure. Hexamethylenetetramine (HMTA) and poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS) was used to improve the crystal structure of Cu2O and ZnO and reduce the defects in the Cu2O/ZnO interface. This fabrication method provided the highly crystallized Cu2O/ZnO structure with excellent electrical property and photoresponse in visible light. The structure was applied to a biosensor for detecting two different cancerous levels of esophageal cells, namely, OE21 and OE21-1, with a high gain in photocurrent (5.8 and 6.2 times, respectively) and a low detection limit (3000 cells in 50 µL). We believe that such a p-n heterojunction PEC biosensor could advance biosensor development and provide a promising candidate for biomedical applications.


Assuntos
Técnicas Biossensoriais , Neoplasias Esofágicas/diagnóstico , Nanocompostos/química , Compostos Bicíclicos Heterocíclicos com Pontes/química , Cobre/química , Humanos , Polímeros/química , Óxido de Zinco/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA