Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
Nat Commun ; 14(1): 3711, 2023 06 22.
Artigo em Inglês | MEDLINE | ID: mdl-37349287

RESUMO

Only 60-75% of conventional kidney stone surgeries achieve complete stone-free status. Up to 30% of patients with residual fragments <2 mm in size experience subsequent stone-related complications. Here we demonstrate a stone retrieval technology in which fragments are rendered magnetizable with a magnetic hydrogel so that they can be easily retrieved with a simple magnetic tool. The magnetic hydrogel facilitates robust in vitro capture of stone fragments of clinically relevant sizes and compositions. The hydrogel components exhibit no cytotoxicity in cell culture and only superficial effects on ex vivo human urothelium and in vivo mouse bladders. Furthermore, the hydrogel demonstrates antimicrobial activity against common uropathogens on par with that of common antibiotics. By enabling the efficient retrieval of kidney stone fragments, our method can lead to improved stone-free rates and patient outcomes.


Assuntos
Cálculos Renais , Ureteroscopia , Animais , Camundongos , Humanos , Hidrogéis , Cálculos Renais/cirurgia , Magnetismo , Fenômenos Magnéticos
2.
Chest ; 163(4): 966-976, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36368616

RESUMO

BACKGROUND: Deficiencies in risk assessment for patients with pulmonary nodules (PNs) contribute to unnecessary invasive testing and delays in diagnosis. RESEARCH QUESTION: What is the accuracy of a novel PN risk model that includes plasma proteins and clinical factors? How does the accuracy compare with that of an established risk model? STUDY DESIGN AND METHODS: Based on technology using magnetic nanosensors, assays were developed with seven plasma proteins. In a training cohort (n = 429), machine learning approaches were used to identify an optimal algorithm that subsequently was evaluated in a validation cohort (n = 489), and its performance was compared with the Mayo Clinic model. RESULTS: In the training set, we identified a support vector machine algorithm that included the seven plasma proteins and six clinical factors that demonstrated an area under the receiver operating characteristic curve of 0.87 and met other selection criteria. The resulting risk reclassification model (RRM) was used to recategorize patients with a pretest risk of between 10% and 84%, and its performance was assessed across five risk strata (low, ≤ 10%; moderate, 10%-34%; intermediate, 35%-70%; high, 71%-84%; very high, > 85%). Stratification by the RRM decreased the proportion of intermediate-risk patients from 26.7% to 10.8% (P < .001) and increased the low-risk and high-risk strata from 16.8% to 21.9% (P < .001) and from 3.7% to 12.1% (P < .001), respectively. Among patients classified as low risk by the RRM and Mayo Clinic model, the corresponding true-negative to false-negative ratios were 16.8 and 19.5, respectively. Among patients classified as very high risk by the RRM and Mayo Clinic model, the corresponding true-positive to false-positive ratios were 28.5 and 17.0, respectively. Compared with the Mayo Clinic model, the RRM provided higher specificity at the low-risk threshold and higher sensitivity at the very high-risk threshold. INTERPRETATION: The RRM accurately reclassified some patients into low-risk and very high-risk categories, suggesting the potential to improve PN risk assessment.


Assuntos
Nódulos Pulmonares Múltiplos , Humanos , Medição de Risco , Algoritmos , Instituições de Assistência Ambulatorial , Proteínas Sanguíneas
3.
Mikrochim Acta ; 189(7): 256, 2022 06 14.
Artigo em Inglês | MEDLINE | ID: mdl-35697882

RESUMO

A strategy is reported to improve the detection limits of current giant magnetoresistance (GMR) biosensors by augmenting the effective magnetic moment that the magnetic tags on the biosensors can exert. Magnetic supercluster particles (MSPs), each of which consists of ~ 1000 superparamagnetic cores, are prepared by a wet-chemical technique and are utilized to improve the limit of detection of GMR biosensors down to 17.6 zmol for biotin as a target molecule. This value is more than four orders of magnitude lower than that of the conventional colorimetric assay performed using the same set of reagents except for the signal transducer. The applicability of MSPs in immunoassay is further demonstrated by simultaneously detecting vascular endothelial growth factor (VEGF) and C-reactive protein (CRP) in a duplex assay format. MSPs outperform commercially available magnetic nanoparticles in terms of signal intensity and detection limit.


Assuntos
Técnicas Biossensoriais , Fator A de Crescimento do Endotélio Vascular , Técnicas Biossensoriais/métodos , Imunoensaio/métodos , Fenômenos Magnéticos , Magnetismo/métodos
4.
Biosens Bioelectron ; 202: 113982, 2022 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-35033828

RESUMO

Hepatocellular carcinoma (HCC) is one of the leading causes of cancer-related deaths worldwide. Most patients, however, are not diagnosed until advanced stage because early HCC lesions generally cause no overt symptoms, and the presence of cirrhosis adds another layer of complexity. While early diagnosis enables more therapeutic options and greatly improves survival rates, it is difficult to achieve. In order to detect early stage HCC, high-risk patients need to frequently measure serum biomarkers such as alpha-fetoprotein (AFP), and gold standards for detection involve less accessible and costly tests. In this work, we present an automated and mobile magnetoresistive biosensor system that allows quick, easy, and accurate detection of a panel of HCC related biomarkers. We first discuss the underlying principles of the giant magnetoresistive (GMR) biosensor system and its unique advantages in early detection of HCC. We also describe the development of hardware, software, and the bioassay, and demonstrate that it can perform an automated assay in 28 min, providing both qualitative and quantitative results. The user only needs to manually add sample into a disposable cartridge and press a button on the smartphone app, without the need for direct interaction with reagent liquids, or lab skills such as pipetting. With its portability, high sensitivity, and ease-of-use, the presented biosensor system has the potential to empower both medical practitioners and patients to achieve early HCC diagnosis. Furthermore, the GMR biosensor platform can be adapted to detect other protein or DNA biomarkers beyond HCC, bringing the goals of accessible mobile health even closer to reality.


Assuntos
Técnicas Biossensoriais , Carcinoma Hepatocelular , Neoplasias Hepáticas , Biomarcadores , Biomarcadores Tumorais , Carcinoma Hepatocelular/diagnóstico , Carcinoma Hepatocelular/patologia , Humanos , Cirrose Hepática/complicações , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/patologia , alfa-Fetoproteínas/metabolismo
5.
Clin Chem ; 67(3): 534-542, 2021 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-33393992

RESUMO

BACKGROUND: Liquid biopsy circulating tumor DNA (ctDNA) mutational analysis holds great promises for precision medicine targeted therapy and more effective cancer management. However, its wide adoption is hampered by high cost and long turnaround time of sequencing assays, or by inadequate analytical sensitivity of existing portable nucleic acid tests to mutant allelic fraction in ctDNA. METHODS: We developed a ctDNA Epidermal Growth Factor Receptor (EGFR) mutational assay using giant magnetoresistive (GMR) nanosensors. This assay was validated in 36 plasma samples of non-small cell lung cancer patients with known EGFR mutations. We assessed therapy response through follow-up blood draws, determined concordance between the GMR assay and radiographic response, and ascertained progression-free survival of patients. RESULTS: The GMR assay achieved analytical sensitivities of 0.01% mutant allelic fraction. In clinical samples, the assay had 87.5% sensitivity (95% CI = 64.0-97.8%) for Exon19 deletion and 90% sensitivity (95% CI = 69.9-98.2%) for L858R mutation with 100% specificity; our assay detected T790M resistance with 96.3% specificity (95% CI = 81.7-99.8%) with 100% sensitivity. After 2 weeks of therapy, 10 patients showed disappearance of ctDNA by GMR (predicted responders), whereas 3 patients did not (predicted nonresponders). These predictions were 100% concordant with radiographic response. Kaplan-Meier analysis showed responders had significantly (P < 0.0001) longer PFS compared to nonresponders (N/A vs. 12 weeks, respectively). CONCLUSIONS: The GMR assay has high diagnostic sensitivity and specificity and is well suited for detecting EGFR mutations at diagnosis and noninvasively monitoring treatment response at the point-of-care.


Assuntos
Técnicas Biossensoriais , Carcinoma Pulmonar de Células não Pequenas , DNA Tumoral Circulante/genética , Análise Mutacional de DNA/métodos , Monitoramento de Medicamentos/métodos , Receptores ErbB/genética , Neoplasias Pulmonares , Acrilamidas/uso terapêutico , Idoso , Compostos de Anilina/uso terapêutico , Carcinoma Pulmonar de Células não Pequenas/diagnóstico , Carcinoma Pulmonar de Células não Pequenas/tratamento farmacológico , Carcinoma Pulmonar de Células não Pequenas/genética , Feminino , Humanos , Biópsia Líquida , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/tratamento farmacológico , Neoplasias Pulmonares/genética , Masculino , Pessoa de Meia-Idade , Mutação , Análise de Sequência com Séries de Oligonucleotídeos , Inibidores de Proteínas Quinases/uso terapêutico , Proteínas Tirosina Quinases/antagonistas & inibidores
6.
Adv Mater Technol ; 5(5)2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-33072854

RESUMO

Microfluidic devices are widely used for applications such as cell isolation. Currently, the most common method to improve throughput for microfluidic devices involves fabrication of multiple, identical channels in parallel. However, this 'numbering up' only occurs in one dimension, thereby limiting gains in volumetric throughput. In contrast, macro-fluidic devices permit high volumetric flow-rates but lack the finer control of microfluidics. Here, we demonstrate how a micro-pore array design enables flow homogenization across a magnetic cell capture device, thus creating a massively parallel series of micro-scale flow channels with consistent fluidic and magnetic properties, regardless of spatial location. This design enables scaling in 2-dimensions, allowing flow-rates exceeding 100 mL/hr while maintaining >90% capture efficiencies of spiked lung cancer cells from blood in a simulated circulating tumor cell system. Additionally, this design facilitates modularity in operation, which we demonstrate by combining two different devices in tandem for multiplexed cell separation in a single pass with no additional cell losses from processing.

7.
Nat Biomed Eng ; 4(3): 325-334, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-32015409

RESUMO

The low magnetic saturation of iron oxide nanoparticles, which are developed primarily as contrast agents for magnetic resonance imaging, limits the sensitivity of their detection using magnetic particle imaging (MPI). Here, we show that FeCo nanoparticles that have a core diameter of 10 nm and bear a graphitic carbon shell decorated with poly(ethylene glycol) provide an MPI signal intensity that is sixfold and fifteenfold higher than the signals from the superparamagnetic iron oxide tracers VivoTrax and Feraheme, respectively, at the same molar concentration of iron. We also show that the nanoparticles have photothermal and magnetothermal properties and can therefore be used for tumour ablation in mice, and that they have high optical absorbance in a broad near-infrared region spectral range (wavelength, 700-1,200 nm), making them suitable as tracers for photoacoustic imaging. As sensitive multifunctional and multimodal imaging tracers, carbon-coated FeCo nanoparticles may confer advantages in cancer imaging and hyperthermia therapy.


Assuntos
Carbono/química , Meios de Contraste/química , Diagnóstico por Imagem/métodos , Compostos Férricos/química , Imageamento por Ressonância Magnética/métodos , Nanopartículas/química , Animais , Neoplasias da Mama/diagnóstico por imagem , Modelos Animais de Doenças , Feminino , Xenoenxertos , Hipertermia Induzida/métodos , Magnetismo , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Nus , Neoplasias/diagnóstico por imagem , Tamanho da Partícula , Polietilenoglicóis
8.
PLoS One ; 14(8): e0221051, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31404106

RESUMO

PURPOSE: To develop a magneto-nanosensor (MNS) based multiplex assay to measure protein and autoantibody biomarkers from human serum for prostate cancer (CaP) diagnosis. MATERIALS AND METHODS: A 4-panel MNS autoantibody assay and a MNS protein assay were developed and optimized in our labs. Using these assays, serum concentration of six biomarkers including prostate-specific antigen (PSA) protein, free/total PSA ratio, as well as four autoantibodies against Parkinson disease 7 (PARK7), TAR DNA-binding protein 43 (TARDBP), Talin 1 (TLN1), and Caldesmon 1 (CALD1) and were analyzed. Human serum samples from 99 patients (50 with non-cancer and 49 with clinically localized CaP) were evaluated. RESULTS: The MNS assay showed excellent performance characteristics and no cross-reactivity. All autoantibody assays showed a statistically significant difference between CaP and non-cancer samples except for PARK7. The most significant difference was the combination of the four autoantibodies as a panel in addition to the free/total PSA ratio. This combination had the highest area under the curve (AUC)- 0.916 in ROC analysis. CONCLUSIONS: Our results suggest that this autoantibody panel along with PSA and free PSA have potential to segregate patients without cancer from those with prostate cancer with higher sensitivity and specificity than PSA alone.


Assuntos
Anticorpos Antineoplásicos/sangue , Autoanticorpos/sangue , Calicreínas/sangue , Antígeno Prostático Específico/sangue , Neoplasias da Próstata , Idoso , Humanos , Imunoensaio , Masculino , Pessoa de Meia-Idade , Neoplasias da Próstata/sangue , Neoplasias da Próstata/diagnóstico , Sensibilidade e Especificidade
9.
Biosens Bioelectron ; 124-125: 136-142, 2019 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-30366258

RESUMO

Aberrant hypermethylation of CpG islands in the promoter region of tumor suppressor genes is a promising biomarker for early cancer detection. This methylation status is reflected in the methylation pattern of ctDNA shed from the primary tumor; however, to realize the full clinical utility of ctDNA methylation detection via liquid biopsy for early cancer diagnosis, improvements in the sensitivity and multiplexability of existing technologies must be improved. Additionally, the assay must be cheap and easy to perform in a clinical setting. We report the integration of methylation specific PCR (MSP) to melt curve analysis on giant magnetoresistive (GMR) biosensors to greatly enhance the sensitivity of our DNA hybridization assay for methylation detection. Our GMR sensor is functionalized with synthetic DNA probes that target methylated or unmethylated CpG sites in the MSP amplicon, and measures the difference in melting temperature (Tm) between the two probes (ΔTm), giving an analytical limit of detection down to 0.1% methylated DNA in solution. Additionally, linear regression of ΔTm's for serial dilutions of methylated:unmethylated mixtures allows for quantification of methylation percentage, which could have diagnostic and prognostic utility. Lastly, we performed multiplexed MSP on two different genes, and show the ability of our GMR assay to resolve this mixture, despite their amplicons' overlapping Tm's in standard EvaGreen melt analysis. The multiplexing ability of our assay and its enhanced sensitivity, without necessitating deep sequencing, represent important steps toward realizing an assay for the detection of methylated ctDNA in plasma for early cancer detection in a clinical setting.


Assuntos
Técnicas Biossensoriais , Metilação de DNA/genética , Melanoma/genética , Ilhas de CpG/genética , Humanos , Melanoma/diagnóstico , Melanoma/patologia , Regiões Promotoras Genéticas , Proteínas Supressoras de Tumor/genética
10.
Nat Biomed Eng ; 2(9): 696-705, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30505627

RESUMO

The detection and analysis of rare blood biomarkers is necessary for early diagnosis of cancer and to facilitate the development of tailored therapies. However, current methods for the isolation of circulating tumour cells (CTCs) or nucleic acids present in a standard clinical sample of only 5-10 ml of blood provide inadequate yields for early cancer detection and comprehensive molecular profiling. Here, we report the development of a flexible magnetic wire that can retrieve rare biomarkers from the subject's blood in vivo at a much higher yield. The wire is inserted and removed through a standard intravenous catheter and captures biomarkers that have been previously labelled with injected magnetic particles. In a proof-of-concept experiment in a live porcine model, we demonstrate the in vivo labelling and single-pass capture of viable model CTCs in less than 10 s. The wire achieves capture efficiencies that correspond to enrichments of 10-80 times the amount of CTCs in a 5-ml blood draw, and 500-5,000 times the enrichments achieved using the commercially available Gilupi CellCollector.

11.
Cancer Biomark ; 22(2): 333-344, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29689709

RESUMO

BACKGROUND AND OBJECTIVE: To monitor therapies targeted to epidermal growth factor receptors (EGFR) in non-small cell lung cancer (NSCLC), we investigated Peroxiredoxin 6 (PRDX6) as a biomarker of response to anti-EGFR agents. METHODS: We studied cells that are sensitive (H3255, HCC827) or resistant (H1975, H460) to gefitinib. PRDX6 was examined with either gefitinib or vehicle treatment using enzyme-linked immunosorbent assays. We created xenograft models from one sensitive (HCC827) and one resistant cell line (H1975) and monitored serum PRDX6 levels during treatment. RESULTS: PRDX6 levels in cell media from sensitive cell lines increased significantly after gefitinib treatment vs. vehicle, whereas there was no significant difference for resistant lines. PRDX6 accumulation over time correlated positively with gefitinib sensitivity. Serum PRDX6 levels in gefitinib-sensitive xenograft models increased markedly during the first 24 hours of treatment and then decreased dramatically during the following 48 hours. Differences in serum PRDX6 levels between vehicle and gefitinib-treated animals could not be explained by differences in tumor burden. CONCLUSIONS: Our results show that changes in serum PRDX6 during the course of gefitinib treatment of xenograft models provide insight into tumor response and such an approach offers several advantages over imaging-based strategies for monitoring response to anti-EGFR agents.


Assuntos
Antineoplásicos/farmacologia , Carcinoma Pulmonar de Células não Pequenas/sangue , Receptores ErbB/antagonistas & inibidores , Neoplasias Pulmonares/sangue , Inibidores de Proteínas Quinases/farmacologia , Animais , Antineoplásicos/uso terapêutico , Biomarcadores , Carcinoma Pulmonar de Células não Pequenas/tratamento farmacológico , Linhagem Celular Tumoral , Modelos Animais de Doenças , Ensaio de Imunoadsorção Enzimática , Feminino , Gefitinibe , Humanos , Neoplasias Pulmonares/tratamento farmacológico , Camundongos , Peroxirredoxina VI/sangue , Peroxirredoxina VI/genética , Peroxirredoxina VI/metabolismo , Inibidores de Proteínas Quinases/uso terapêutico , Quinazolinas/farmacologia , Quinazolinas/uso terapêutico , Resultado do Tratamento , Ensaios Antitumorais Modelo de Xenoenxerto
12.
Theranostics ; 8(5): 1389-1398, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29507628

RESUMO

Cancer proteomics is the manifestation of relevant biological processes in cancer development. Thus, it reflects the activities of tumor cells, host-tumor interactions, and systemic responses to cancer therapy. To understand the causal effects of tumorigenesis or therapeutic intervention, longitudinal studies are greatly needed. However, most of the conventional mouse experiments are unlikely to accommodate frequent collection of serum samples with a large enough volume for multiple protein assays towards single-object analysis. Here, we present a technique based on magneto-nanosensors to longitudinally monitor the protein profiles in individual mice of lymphoma models using a small volume of a sample for multiplex assays. Methods: Drug-sensitive and -resistant cancer cell lines were used to develop the mouse models that render different outcomes upon the drug treatment. Two groups of mice were inoculated with each cell line, and treated with either cyclophosphamide or vehicle solution. Serum samples taken longitudinally from each mouse in the groups were measured with 6-plex magneto-nanosensor cytokine assays. To find the origin of IL-6, experiments were performed using IL-6 knock-out mice. Results: The differences in serum IL-6 and GCSF levels between the drug-treated and untreated groups were revealed by the magneto-nanosensor measurement on individual mice. Using the multiplex assays and mouse models, we found that IL-6 is secreted by the host in the presence of tumor cells upon the drug treatment. Conclusion: The multiplex magneto-nanosensor assays enable longitudinal proteomic studies on mouse tumor models to understand tumor development and therapy mechanisms more precisely within a single biological object.


Assuntos
Linfoma/metabolismo , Magnetismo/instrumentação , Nanotecnologia/instrumentação , Proteômica , Animais , Citocinas/metabolismo , Modelos Animais de Doenças , Linfoma/patologia , Camundongos Endogâmicos C57BL , Camundongos Knockout , Análise de Sobrevida , Regulação para Cima
13.
PLoS One ; 12(11): e0188510, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29186152

RESUMO

Single-cell characterization techniques, such as mRNA-seq, have been applied to a diverse range of applications in cancer biology, yielding great insight into mechanisms leading to therapy resistance and tumor clonality. While single-cell techniques can yield a wealth of information, a common bottleneck is the lack of throughput, with many current processing methods being limited to the analysis of small volumes of single cell suspensions with cell densities on the order of 107 per mL. In this work, we present a high-throughput full-length mRNA-seq protocol incorporating a magnetic sifter and magnetic nanoparticle-antibody conjugates for rare cell enrichment, and Smart-seq2 chemistry for sequencing. We evaluate the efficiency and quality of this protocol with a simulated circulating tumor cell system, whereby non-small-cell lung cancer cell lines (NCI-H1650 and NCI-H1975) are spiked into whole blood, before being enriched for single-cell mRNA-seq by EpCAM-functionalized magnetic nanoparticles and the magnetic sifter. We obtain high efficiency (> 90%) capture and release of these simulated rare cells via the magnetic sifter, with reproducible transcriptome data. In addition, while mRNA-seq data is typically only used for gene expression analysis of transcriptomic data, we demonstrate the use of full-length mRNA-seq chemistries like Smart-seq2 to facilitate variant analysis of expressed genes. This enables the use of mRNA-seq data for differentiating cells in a heterogeneous population by both their phenotypic and variant profile. In a simulated heterogeneous mixture of circulating tumor cells in whole blood, we utilize this high-throughput protocol to differentiate these heterogeneous cells by both their phenotype (lung cancer versus white blood cells), and mutational profile (H1650 versus H1975 cells), in a single sequencing run. This high-throughput method can help facilitate single-cell analysis of rare cell populations, such as circulating tumor or endothelial cells, with demonstrably high-quality transcriptomic data.


Assuntos
Sequenciamento de Nucleotídeos em Larga Escala/métodos , RNA Mensageiro/genética , Linhagem Celular Tumoral , Perfilação da Expressão Gênica , Humanos , Neoplasias Pulmonares/genética , Neoplasias Pulmonares/patologia , Mutação
14.
Nano Lett ; 17(11): 6644-6652, 2017 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-28990786

RESUMO

Each immunoglobulin isotype has unique immune effector functions. The contribution of these functions in the elimination of pathogens and tumors can be determined by monitoring quantitative temporal changes in isotype levels. Here, we developed a novel technique using magneto-nanosensors based on the effect of giant magnetoresistance (GMR) for longitudinal monitoring of total and antigen-specific isotype levels with high precision, using as little as 1 nL of serum. Combining in vitro serologic measurements with in vivo imaging techniques, we investigated the role of the antibody response in the regression of firefly luciferase (FL)-labeled lymphoma cells in spleen, kidney, and lymph nodes in a syngeneic Burkitt's lymphoma mouse model. Regression status was determined by whole body bioluminescent imaging (BLI). The magneto-nanosensors revealed that anti-FL IgG2a and total IgG2a were elevated and sustained in regression mice compared to non-regression mice (p < 0.05). This platform shows promise for monitoring immunotherapy, vaccination, and autoimmunity.


Assuntos
Formação de Anticorpos , Técnicas Biossensoriais/instrumentação , Linfoma de Burkitt/imunologia , Imunoglobulina G/análise , Magnetismo/instrumentação , Animais , Linfoma de Burkitt/sangue , Linfoma de Burkitt/diagnóstico por imagem , Desenho de Equipamento , Feminino , Imunoglobulina G/sangue , Imunoglobulina G/imunologia , Medições Luminescentes/métodos , Camundongos , Camundongos Endogâmicos C57BL , Imagem Óptica/instrumentação , Tamanho da Amostra
15.
ACS Nano ; 11(9): 8864-8870, 2017 09 26.
Artigo em Inglês | MEDLINE | ID: mdl-28832112

RESUMO

Epigenetic modifications, in particular DNA methylation, are gaining increasing interest as complementary information to DNA mutations for cancer diagnostics and prognostics. We introduce a method to simultaneously profile DNA mutation and methylation events for an array of sites with single site specificity. Genomic (mutation) or bisulphite-treated (methylation) DNA is amplified using nondiscriminatory primers, and the amplicons are then hybridized to a giant magnetoresistive (GMR) biosensor array followed by melting curve measurements. The GMR biosensor platform offers scalable multiplexed detection of DNA hybridization, which is insensitive to temperature variation. The melting curve approach further enhances the assay specificity and tolerance to variations in probe length. We demonstrate the utility of this method by simultaneously profiling five mutation and four methylation sites in human melanoma cell lines. The method correctly identified all mutation and methylation events and further provided quantitative assessment of methylation density validated by bisulphite pyrosequencing.


Assuntos
Técnicas Biossensoriais/instrumentação , Análise Mutacional de DNA/instrumentação , DNA/genética , Melanoma/genética , Análise de Sequência com Séries de Oligonucleotídeos/instrumentação , Linhagem Celular Tumoral , Metilação de DNA , Desenho de Equipamento , Humanos , Mutação , Desnaturação de Ácido Nucleico
16.
Methods Mol Biol ; 1634: 153-162, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28819848

RESUMO

Circulating tumor cells (CTCs) are currently widely studied for their potential application as part of a liquid biopsy. These cells are shed from the primary tumor into the circulation, and are postulated to provide insight into the molecular makeup of the actual tumor in a minimally invasive manner. However, they are extremely rare in blood, with typical concentrations of 1-100 in a milliliter of blood; hence, a need exists for a rapid and high-purity method for isolating CTCs from whole blood. Here, we describe the application of a microfabricated magnetic sifter toward isolation of CTCs from whole blood at volumetric flow rates of 10 mL/h, along with the use of a PDMS-based nanowell system for single-cell gene expression profiling. This method allows rapid isolation of CTCs and subsequent integration with downstream genetic profiling methods for clinical applications such as targeted therapy, therapy monitoring, or further biological studies.


Assuntos
Separação Celular/métodos , Filtração/métodos , Regulação Neoplásica da Expressão Gênica , Neoplasias Pulmonares/diagnóstico , Células Neoplásicas Circulantes/patologia , Análise de Célula Única/métodos , Linhagem Celular Tumoral , Separação Celular/instrumentação , Tamanho Celular , Dimetilpolisiloxanos/química , Desenho de Equipamento , Filtração/instrumentação , Perfilação da Expressão Gênica , Humanos , Neoplasias Pulmonares/sangue , Neoplasias Pulmonares/patologia , Nanopartículas de Magnetita/química , Imãs , Nanoporos , Células Neoplásicas Circulantes/metabolismo , Nylons/química , Reologia , Análise de Célula Única/instrumentação
17.
Mol Cell Oncol ; 4(2): e1289295, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28401190

RESUMO

Numerous techniques for isolating circulating tumor cells (CTCs) have been developed. Concurrently, single-cell techniques that can reveal molecular components of CTCs have become widely available. We discuss how the combination of isolation and multigene profiling of single CTCs in our platform can facilitate eventual translation to the clinic.

18.
Stem Cells Transl Med ; 6(1): 151-160, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-28170185

RESUMO

Clinical translation of cell-based strategies for tissue regeneration remains challenging because survival of implanted cells within hostile, hypoxic wound environments is uncertain. Overexpression of B-cell lymphoma 2 (Bcl-2) has been shown to inhibit apoptosis in implanted cells. The present study describes an "off the shelf" prefabricated scaffold integrated with magnetic nanoparticles (MNPs) used to upregulate Bcl-2 expression in implanted adipose-derived stromal cells for bone regeneration. Iron oxide cores were sequentially coated with branched polyethyleneimine, minicircle plasmid encoding green fluorescent protein and Bcl-2, and poly-ß-amino ester. Through in vitro assays, increased osteogenic potential and biological resilience were demonstrated in the magnetofected group over control and nucleofected groups. Similarly, our in vivo calvarial defect study showed that magnetofection had an efficiency rate of 30%, which in turn resulted in significantly more healing compared with control group and nucleofected group. Our novel, prefabricated MNP-integrated scaffold allows for in situ postimplant temporospatial control of cell transfection to augment bone regeneration. Stem Cells Translational Medicine 2017;6:151-160.


Assuntos
Regeneração Óssea , Nanopartículas de Magnetita/química , Proteínas Proto-Oncogênicas c-bcl-2/metabolismo , Regulação para Cima , Tecido Adiposo/citologia , Adulto , Animais , Sobrevivência Celular , Regulação da Expressão Gênica , Humanos , Campos Magnéticos , Masculino , Camundongos , Pessoa de Meia-Idade , Osteogênese/genética , Células Estromais/citologia , Células Estromais/transplante , Alicerces Teciduais/química
19.
Proc Natl Acad Sci U S A ; 113(52): E8379-E8386, 2016 12 27.
Artigo em Inglês | MEDLINE | ID: mdl-27956614

RESUMO

Circulating tumor cells (CTCs) are established cancer biomarkers for the "liquid biopsy" of tumors. Molecular analysis of single CTCs, which recapitulate primary and metastatic tumor biology, remains challenging because current platforms have limited throughput, are expensive, and are not easily translatable to the clinic. Here, we report a massively parallel, multigene-profiling nanoplatform to compartmentalize and analyze hundreds of single CTCs. After high-efficiency magnetic collection of CTC from blood, a single-cell nanowell array performs CTC mutation profiling using modular gene panels. Using this approach, we demonstrated multigene expression profiling of individual CTCs from non-small-cell lung cancer (NSCLC) patients with remarkable sensitivity. Thus, we report a high-throughput, multiplexed strategy for single-cell mutation profiling of individual lung cancer CTCs toward minimally invasive cancer therapy prediction and disease monitoring.


Assuntos
Biomarcadores Tumorais/sangue , Carcinoma Pulmonar de Células não Pequenas/sangue , Neoplasias Pulmonares/sangue , Células Neoplásicas Circulantes , Adulto , Idoso , Carcinoma Pulmonar de Células não Pequenas/patologia , Contagem de Células , Feminino , Perfilação da Expressão Gênica , Regulação Neoplásica da Expressão Gênica , Humanos , Antígenos Comuns de Leucócito/sangue , Neoplasias Pulmonares/patologia , Masculino , Microfluídica , Pessoa de Meia-Idade , Mutação , Nanotecnologia , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Análise de Célula Única
20.
ACS Nano ; 10(12): 10652-10660, 2016 12 27.
Artigo em Inglês | MEDLINE | ID: mdl-27636738

RESUMO

Autoantibodies are a hallmark of autoimmune diseases such as lupus and have the potential to be used as biomarkers for diverse diseases, including immunodeficiency, infectious disease, and cancer. More precise detection of antibodies to specific targets is needed to improve diagnosis of such diseases. Here, we report the development of reusable peptide microarrays, based on giant magnetoresistive (GMR) nanosensors optimized for sensitively detecting magnetic nanoparticle labels, for the detection of antibodies with a resolution of a single post-translationally modified amino acid. We have also developed a chemical regeneration scheme to perform multiplex assays with a high level of reproducibility, resulting in greatly reduced experimental costs. In addition, we show that peptides synthesized directly on the nanosensors are approximately two times more sensitive than directly spotted peptides. Reusable peptide nanosensor microarrays enable precise detection of autoantibodies with high resolution and sensitivity and show promise for investigating antibody-mediated immune responses to autoantigens, vaccines, and pathogen-derived antigens as well as other fundamental peptide-protein interactions.


Assuntos
Autoanticorpos , Peptídeos , Análise Serial de Proteínas , Processamento de Proteína Pós-Traducional , Autoantígenos , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA