Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Clin Exp Ophthalmol ; 45(5): 520-528, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28013525

RESUMO

BACKGROUND: Microinvasive glaucoma surgery (MIGS) is a relatively new addition to the glaucoma treatment paradigm. Small metallic stents are inserted into the trabecular meshwork in order to increase aqueous humour drainage. MIGS procedures are rapidly being adopted owing to a more favourable side effect profile when compared with traditional surgery. Remarkably, this rapid rate of utilization has occurred without any published studies on the effect of metal alloys used in these stents on human trabecular meshwork cells (HTMCs). Therefore, this study aimed to determine the effect of candidate metal alloys for MIGS on HTMC morphology, viability and function. METHODS: Human trabecular meshwork cells were cultured on the surfaces of titanium (polished and sandblasted), a titanium-nickel (nitinol) alloy and glass (as control substratum). Fluorescence imaging was used to assess cell morphology and spreading. A lactate dehydrogenase cytotoxicity assay, cell death detection ELISA, MTT cell viability assay, BrdU cell proliferation assay and fibronectin ELISA were also conducted. RESULTS: Cells cultured on sandblasted titanium exhibited significantly greater spreading than cells cultured on other substrata. In comparison, HTMCs cultured on nitinol displayed poor spreading. Significantly more cell death, by both necrosis and apoptosis, occurred on nitinol than on titanium and glass. Also, cell viability and proliferation were suppressed on nitinol compared with titanium or glass. Finally, HTMCs on both titanium and nitinol produced greater amounts of fibronectin than cells grown on glass. CONCLUSIONS: Substratum topography and metal alloy composition were found to impact morphology, viability and function of primary HTMC cultures.


Assuntos
Ligas/farmacologia , Cirurgia Filtrante/métodos , Implantes para Drenagem de Glaucoma , Glaucoma/patologia , Procedimentos Cirúrgicos Minimamente Invasivos , Malha Trabecular/ultraestrutura , Apoptose , Proliferação de Células , Sobrevivência Celular , Células Cultivadas , Colorimetria , Ensaio de Imunoadsorção Enzimática , Glaucoma/metabolismo , Glaucoma/cirurgia , Humanos , Microscopia Eletrônica de Varredura , Microscopia de Fluorescência , Malha Trabecular/efeitos dos fármacos , Malha Trabecular/metabolismo
2.
PLoS One ; 10(7): e0131770, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26147908

RESUMO

BACKGROUND: Minimally invasive glaucoma surgeries (MIGS) have attracted significant attention, as they have been reported to lower intra-ocular pressure (IOP) and have an excellent safety profile. The iStent is an example of a minimally invasive glaucoma device that has received particular attention due to its early and wide spread utilization. There is a growing body of evidence supporting its use at the time of phacoemulsification to help lower IOP. However, it is still not clear how much of the IOP lowering effect can be attributed to the iStent, the crystalline lens extraction or both when inserted concurrently at the time of phacoemulsification. This has been an important issue in understanding its potential role in the glaucoma management paradigm. PURPOSE: To conduct a systematic review and meta-analysis comparing the IOP lowering effect of iStent insertion at the time of phacoemulsification versus phacoemulsification alone for patients with glaucoma and cataracts. METHODS: A systematic review was conducted utilizing various databases. Studies examining the IOP lowering effect of iStent insertion in combination with phacoemulsification, as well as studies examining the IOP lowering effect of phacoemulsification alone were included. Thirty-seven studies, reporting on 2495 patients, met the inclusion criteria. The percentage reduction in IOP (IOPR%) and mean reduction in topical glaucoma medications after surgery were determined. The standardized mean difference (SMD) was computed as a measure of the treatment effect for continuous outcomes taking into account heterogeneity. Fixed-effect and random-effect models were applied. RESULTS: A 4% IOP reduction (IOPR%) from baseline occurred following phacoemulsification as a solo procedure compared to 9% following an iStent implant with phacoemulsification, and 27% following 2 iStents implants with phacoemulsification. Compared with cataract extraction alone, iStent with phacoemulsification resulted in significant reduction in the post-operative IOP (IOPR%) (SMD = -0.46, 95% CI: [-0.87, -0.06]). A weighted mean reduction in the number of glaucoma medications per patient was 1.01 following phacoemulsification alone compared to 1.33 after one iStent implant with phacoemulsification, and 1.1 after 2 iStent implants with phacoemulsification. Compared to cataract extraction alone, iStent with cataract extraction showed a significant decrease in the number of glaucoma medications (SMD = -0.65, 95% CI: [-1.18, -0.12]). Funnel plots suggested the absence of publication bias. CONCLUSION: Both iStent implantation with concurrent phacoemulsification and phacoemulsification alone result in a significant decrease in IOP and topical glaucoma medications. In terms of both reductions, iStent with phacoemulsification significantly outperforms phacoemulsification alone.


Assuntos
Catarata/terapia , Glaucoma/cirurgia , Idoso , Idoso de 80 Anos ou mais , Anti-Hipertensivos/uso terapêutico , Estudos de Casos e Controles , Extração de Catarata/métodos , Estudos de Coortes , Implantes para Drenagem de Glaucoma , Humanos , Pressão Intraocular/efeitos dos fármacos , Pressão Intraocular/fisiologia , Implante de Lente Intraocular/métodos , Cristalino/cirurgia , Pessoa de Meia-Idade , Facoemulsificação/métodos , Tonometria Ocular/métodos
3.
PLoS One ; 10(5): e0128146, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26018579

RESUMO

BACKGROUND: Glaucoma is a leading cause of irreversible blindness. It is firmly entrenched in the traditional treatment paradigm to start with pharmacotherapy. However, pharmacotherapy is not benign and has been well documented to have a number of significant challenges. Minimally invasive glaucoma surgery (MIGS) that targets the outflow pathway with minimal to no scleral dissection has resulted in the need to reconsider the glaucoma treatment paradigm. PURPOSE: To perform a systematic review and meta-analysis to evaluate and quantify the effect on post-operative intraocular pressure (IOP) and number of topical glaucoma medications, in patients receiving the iStent MIGS device as the solo procedure without concurrent cataract surgery. METHODS: A systematic review was conducted by searching various databases between January 1, 2000, and June 30, 2014. Studies reporting up to a maximum follow-up period of 24 months were retrieved and screened using the EPPI-Reviewer 4 gateway. Percentage reduction in IOP (IOPR%), and mean reduction in topical glaucoma medications after surgery were computed. Meta-analysis was performed using STATA v. 13.0. The standardized mean difference (SMD) was calculated as the effect size for continuous scale outcomes. Heterogeneity was determined using the I2 statistics, Z-value, and χ2 statistics. Fixed-effect and random-effect models were developed based on heterogeneity. Sub-group analysis was performed based on the number of iStents implanted and the follow-up period. The outcome measures were changes in the IOP and number of glaucoma medications. RESULTS: The search strategy identified 105 records from published literature and 9 records from the grey literature. Five studies with 248 subjects were included for quantitative synthesis. A 22% IOP reduction (IOPR%) from baseline occurred at 18-months after one iStent implant, 30% at 6-months after two iStents implantations, and 40% at 6-months after implantation of three iStents. A mean reduction of 1.2 bottles per patient of topical glaucoma medications occurred at 18-months after one iStent implant, 1.45 bottles per patient at 6-months after two iStents, and one bottle of medication per patient was reduced at 6-months following placement of three iStents implants. Meta-analysis results showed a significant reduction in the IOP after one iStent (SMD = -1.68, 95% CI: [-2.7, -0.61]), two iStents (SMD = -1.88, 95% CI: [-2.2, -1.56]), and three iStents (SMD = -2, 95% CI: [-2.62, -1.38]) implantation. Results showed a significant drop in the topical glaucoma medications after one iStent (SMD = -2.11, CI: [-3.95, -0.27]), two iStent (SMD = -1.88, CI: [-2.20, -1.56]), and three iStents (SMD = -2.00, CI: [-2.62, -1.38]) implantation. The maximum reduction in IOP occurred at 12-months (SMD = -2.21, CI: [-2.53, -1.88]) and a significant reduction in post-operative topical glaucoma medications occurred even after 18-months of iStent implantation (SMD = -0.71, CI: [-1.15, -0.26]). CONCLUSION: iStent implantation as a solo procedure without concurrent cataract extraction does lower IOP, and reduces the dependency on glaucoma medications. This effect seems to last at least 18 months.


Assuntos
Glaucoma/cirurgia , Glaucoma/terapia , Idoso , Anti-Hipertensivos/uso terapêutico , Catarata/terapia , Extração de Catarata/métodos , Glaucoma/tratamento farmacológico , Humanos , Pressão Intraocular/efeitos dos fármacos , Pressão Intraocular/fisiologia , Cristalino/efeitos dos fármacos , Cristalino/cirurgia , Estudos Prospectivos , Stents , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA