Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Cytometry B Clin Cytom ; 100(4): 509-518, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-32896973

RESUMO

INTRODUCTION: The diagnosis of CLL/SLL relies on flow cytometric immunophenotyping. Increasing emphasis is being placed on precise detection of the minimal residual disease. Following antigen recommendations of ERIC and ESCCA's Harmonization Project, we validated a 14-color assay for the characterization CD5+ lymphoproliferative neoplasms and CLL MRD with a sensitivity of at least 10-4 . METHODS: The assay was designed based on ERIC/ESCCA recommended antigens with the addition of CD40 for alternate gating when CD19 expression is reduced. Lower limit of quantitation/lower limit of detection, assay procedural precision, linearity, and limit of blank were established. Then, 52 CD5+ B-cell lymphoproliferative neoplasms (41 CLL/11 non-CLL) and 29 normal samples were used for parallel evaluation. Automated cluster identification and quantitation of CLL clones in MRD setting was performed using Barned-Hutt SNE. Separation analysis between CLL and non-CLL phenotypes was performed by PCA and bh-SNE. RESULTS: Separation ratios for each antigen exceeded ERIC/ESCCA guidelines. Precision was <20% at LLOQ (0.01%). The limit of blank was <10/500,000 cells. Concordance between the 14-color and legacy assay (Deming regression y = 1.01x, r2  = .99) was seen. All 20 samples with MRD levels 0.5%-0.006% (median 0.04%) showed an abnormal cell cluster by bh-SNE, with concordant results between manual and automated quantitation (y = x, r2  = 1). CLL cases clustered together and away from mantle cell lymphoma by bh-SNE and PCA with outlier atypical phenotype CLL cases posing diagnostic challenges by both manual and automated analysis. CONCLUSION: The 14-color CD5+ LPD assay provides a robust standardization platform for MRD and disease characterization using both manual and automated analysis.


Assuntos
Antígenos CD5/isolamento & purificação , Citometria de Fluxo , Leucemia Linfocítica Crônica de Células B/diagnóstico , Neoplasia Residual/diagnóstico , Antígenos CD19/imunologia , Linfócitos B/imunologia , Linfócitos B/patologia , Antígenos CD40/imunologia , Antígenos CD5/imunologia , Feminino , Humanos , Imunofenotipagem , Leucemia Linfocítica Crônica de Células B/genética , Leucemia Linfocítica Crônica de Células B/imunologia , Leucemia Linfocítica Crônica de Células B/patologia , Masculino , Neoplasia Residual/imunologia , Neoplasia Residual/patologia
2.
Blood Adv ; 1(12): 728-732, 2017 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-29296716

RESUMO

In patients with multiple myeloma, obtaining posttreatment minimal residual disease (MRD) negativity is associated with longer progression-free survival and overall survival. Here, we compared the diagnostic performance of a single 10-color tube with that of a EuroFlow 8-color 2-tube panel for MRD testing. Bone marrow samples from 41 multiple myeloma patients were tested in parallel using the 2 approaches. Compared with the sum of the cells from the EuroFlow two 8-color tubes, the Memorial Sloan Kettering Cancer Center (MSKCC) single 10-color tube had a slight reduction in total cell number with a mean ratio of 0.85 (range, 0.57-1.46; P < .05), likely attributable to permeabilization of the cells. Percent of plasma cells showed a high degree of concordance (r2 = 0.97) as did normal plasma cells (r2 = 0.96), consistent with no selective plasma cell loss. Importantly, concordant measurement of residual disease burden was seen with abnormal plasma cells (r2 = 0.97). The overall concordance between the 2 tests was 98%. In 1 case, there was a discrepancy near the limit of detection of both tests in favor of the slightly greater theoretical sensitivity of the EuroFlow 8-color 2-tube panel (analytical sensitivity limit of MSKCC single 10-color tube: 6 cells in 1 million with at least 3 million cell acquisitions; EuroFlow 8-color 2-tube panel: 2 cells in 1 million with the recommended 10 million cell acquisitions).

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA