Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
2.
Br J Surg ; 110(5): 606-613, 2023 04 12.
Artigo em Inglês | MEDLINE | ID: mdl-36930564

RESUMO

BACKGROUND: Personal protective equipment (PPE) adversely affects pulmonary gas exchange and may result in systemic hypercapnic hypoxaemia and headache. This study aimed to determine what extent PPE affects cerebral symptoms, global cerebral blood flow, and cognitive functional performance. METHODS: Higher surgical trainees participated in a randomized, repeated-measures, crossover study, completing 60 min of laparoscopic surgical simulation in both standard operating attire and type 3 PPE. Measurements were collected at baseline and after 60 min of simulation. The primary outcome measure was headache. Headache was examined using the validated visual analogue scale (VAS) and Environmental Symptoms Questionnaire C (ESQ-C), global cerebral blood flow with duplex ultrasonography, and visuospatial and executive gross/fine motor function with grooved peg board (GPB) and laparoscopic bead (LSB) board tasks. RESULTS: Thirty-one higher surgical trainees (20 men, 11 women) completed the study. Compared with standard operating attire, PPE increased headache assessment scores (mean(s.d.) VAS score 3.5(5.6) versus 13.0(3.7), P < 0.001; ESQ-C score 1.3(2.0) versus 5.9(5.1), P < 0.001) and was associated with poorer completion times for GPB-D (61.4(12.0) versus 71.1(12.4) s; P = 0.034) and LSB (192.5(66.9) versus 270.7(135.3) s; P = 0.025) tasks. Wearing PPE increased heart rate (82.5(13.6) versus 93.5(13.0) beats/min; P = 0.022) and skin temperature (36.6(0.4) versus 37.1(0.5)°C; P < 0.001), but decreased peripheral oxygen saturation (97.9(0.8) versus 96.8(1.0) per cent; P < 0.001). Female higher surgical trainees exhibited higher peripheral oxygen saturation across all conditions. No differences were observed in global cerebral blood flow as a function of attire, time or sex. CONCLUSION: Despite no marked changes in global cerebral blood flow, type 3 PPE was associated with increased headache scores and cerebral symptoms (VAS and ESQ-C) alongside impaired executive motor function highlighting the clinical implications of PPE-induced impairment for cognitive-clinical performance.


Assuntos
Cefaleia , Hipercapnia , Hipóxia , Equipamento de Proteção Individual , Humanos , Masculino , Feminino , Equipamento de Proteção Individual/efeitos adversos , Estudos Cross-Over , Circulação Cerebrovascular , Cognição
3.
Endosc Int Open ; 7(1): E9-E14, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30648134

RESUMO

Background and study aims Video-colonoscopy, despite being the gold-standard for diagnosis of colorectal lesions, has limitations including patient discomfort and risk of complications. This study assessed training characteristics and acceptability in operators of a new robotic colonoscope (RC). Materials and methods Participants (n = 9) with varying degrees of skill and background knowledge in colonoscopy performed colonoscopies with a RC on a simulation-based training model. Quantitative procedure-related and qualitative operator-related parameters were recorded. Results Polyp detection rate was highest in the novice group (91.67 %) followed by experts (86.11 %), then equally, trainees and video gamers (79.17 %). Four participants repeated the procedure at a follow-up session. Each participant improved cecal intubation time and had the same or higher polyp detection rate. The potential role for RC was identified for an out-of-hospital environment and as a novel diagnostic tool. Conclusions Results from this pilot suggest that operators at all skill levels found the RC acceptable and potentially useful as a diagnostic tool. Acquisition of skills with RC seems to improve rapidly to a clinically relevant level with simulation-based training.

4.
Surg Endosc ; 28(7): 2057-65, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24570011

RESUMO

BACKGROUND: Ultravision™ is a new device that utilizes electrostatic precipitation to clear surgical smoke. The aim was to evaluate its performance during laparoscopic cholecystectomy. METHODS: Patients undergoing laparoscopic cholecystectomy were randomized into "active (device on)" or "control (device off)." Three operating surgeons scored the percentage effective visibility and three reviewers scored the percentage of the procedure where smoke was present. All assessors also used a 5-point scale (1 = imperceptible/excellent and 5 = very annoying/bad) to rate visual impairment. Secondary outcomes were the number of smoke-related pauses, camera cleaning, and pneumoperitoneum reductions. Mean results are presented with 95% confidence intervals (CI). RESULTS: In 30 patients (active 13, control 17), the effective visibility was 89.2% (83.3-95.0) for active cases and 71.2% (65.7-76.7) for controls. The proportion of the procedure where smoke was present was 41.1% (33.8-48.3) for active cases and 61.5% (49.0-74.1) for controls. Operating surgeons rated the visual impairment as 2.2 (1.7-2.6) for active cases and 3.2 (2.8-3.5) for controls. Reviewers rated the visual impairment as 2.3 (2.0-2.5) for active cases and 3.2 (2.8-3.7) for controls. In the active group, 23% of procedures were paused to allow smoke clearance compared to 94% of control cases. Camera cleaning was not needed in 85% of active procedures and 35% of controls. The pneumoperitoneum was reduced in 0% of active cases and 88% of controls. CONCLUSIONS: Ultravision™ improves visibility during laparoscopic surgery and reduces delays in surgery for smoke clearance and camera cleaning.


Assuntos
Colecistectomia Laparoscópica/instrumentação , Colecistectomia Laparoscópica/métodos , Fumaça , Eletricidade Estática , Visão Ocular , Adulto , Poluentes Ocupacionais do Ar , Método Duplo-Cego , Contaminação de Equipamentos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Salas Cirúrgicas , Duração da Cirurgia , Projetos Piloto , Estudos Prospectivos
6.
Gastrointest Endosc ; 79(3): 490-7, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24210655

RESUMO

BACKGROUND: The Welsh Institute for Minimal Access Therapy (WIMAT) colonoscopy suitcase is an ex vivo porcine simulator for polypectomy training. OBJECTIVE: To establish whether this model has construct and concurrent validity. DESIGN: Prospective, cross-sectional study. SETTING: Endoscopic training center. PARTICIPANTS: Twenty novice (N), 20 intermediate (I), 20 advanced (Ad), and 20 expert (E) colonoscopists. INTERVENTION: A simulated polypectomy task aimed at removing 2 polyps; A (simple), B (complex). MAIN OUTCOME MEASUREMENTS: Two accredited colonoscopists, blinded to group allocation, scored performances according to Direct Observation of Polypectomy Skills (DOPyS) assessment parameters. Group performances were compared. Real-life DOPyS scores were correlated to simulator DOPyS results. RESULTS: Median overall DOPyS scores for novices were 1.00 (1.00-1.87) for A and 0.50 (0.00-1.00) for B (A vs B; P < .01). Intermediates scored 2.50 (2.00-2.88) for A and 2.00 (1.13-2.50) for B (A vs B; P = .03). The advanced group scored 3.00 (2.50-3.50) for A and 2.50 (2.00-3.00) for B (A vs B; P = .01). Experts scored 3.00 (3.00-3.88) for A and 3.00 (2.50-3.50) for B (A vs B; P = .47). Intergroup comparisons for A were, N vs I; P < .01, N vs Ad; P < .01, N vs E; P < .01, I vs Ad; P < .01, I vs E; P < .01, and Ad vs E; P = .46. Intergroup comparisons for B were, N vs I; P < .01, N vs Ad; P < .01, N vs E; P < .01, I vs Ad; P = .03, I vs E; P <.01, and Ad vs E; P = .06. There was no difference between real-life DOPyS scores and simulator scores (0.07). LIMITATIONS: The model does not have inbuilt assessment parameters. CONCLUSION: This simulator demonstrates construct and concurrent validity for colon polypectomy training.


Assuntos
Competência Clínica , Pólipos do Colo/cirurgia , Colonoscopia/educação , Modelos Animais , Animais , Estudos Transversais , Humanos , Estudos Prospectivos , Suínos , Análise e Desempenho de Tarefas
7.
Am J Surg ; 207(1): 32-8, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24269037

RESUMO

BACKGROUND: The aim of this study was to establish if endoscopists can reliably self-assess their ability to perform simulated colonic polypectomy. METHODS: Novices, intermediates, advanced, and experts performed a video-recorded polypectomy task using the Welsh Institute for Minimal Access Therapy (WIMAT) colonoscopy suitcase simulator. This involved removal of a simple polyp (A) and a complex polyp (B). Participants self-assessed themselves using a Direct Observation of Polypectomy Skills (DOPyS) assessment form. Two blinded, independent, Joint Advisory Group on Gastrointestinal Endoscopy (JAG) accredited assessors graded each performance using the same DOPyS scoring. The Spearman coefficient was used to determine the correlation between self and assessors' scores. RESULTS: Eighty participants completed the task. There was a weak correlation between assessors' scores and self-assessment scores for all groups (novices: ρ = -.44, P = .85; intermediates: ρ = -.16, P = .51; advanced: ρ = .16, P = .50; and experts: ρ = .07, P = .76). There was a strong correlation between scores from assessor 1 and 2 for polyp A (ρ = .80, P ≤ .01) and polyp B (ρ = .80, P ≤ .01). CONCLUSIONS: The correlation between self-assessment and assessors' scores is weak. Novices and intermediates underestimate performance, whereas advanced and experts overestimate performance. Regular feedback may improve accuracy.


Assuntos
Colonoscopia , Simulação por Computador , Pólipos Intestinais/cirurgia , Autoavaliação (Psicologia) , Adulto , Colonoscopia/educação , Colonoscopia/normas , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , País de Gales
8.
Surg Endosc ; 27(9): 3100-7, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23605191

RESUMO

BACKGROUND: Smoke is generated by energy-based surgical instruments. The airborne byproducts may have potential health implications. This study aimed to evaluate the properties of surgical smoke and the evidence for the harmful effects to the theater staff. METHODS: Cochrane Database, MEDLINE, PubMed, Embase classic and Embase, and the metaRegister of Controlled Trials were searched for studies reporting the constituents found in the smoke plume created during surgical procedures, the methods used to analyze the smoke, the implications of exposure, and the type of surgical instrument that generated the smoke. Studies were excluded if they were animal based, preclinical experimental work, or opinion-based reports. The common end points were particle size and characteristics, infection risk, malignant spread, and mutagenesis. RESULTS: The inclusion criteria were fulfilled by 20 studies. In terms of particle size, 5 (25%) of the 20 studies showed that diathermy and laser can produce ultrafine particles (UFP) that are respirable in size. With regard to particle characterization, 7 (35%) of the 20 studies demonstrated that a variety of volatile hydrocarbons are present in diathermy-, ultrasonic-, and laser-derived surgical smoke. These are potentially carcinogenic, but no evidence exists to support a cause-effect relationship for those exposed. In terms of infection risk, 6 (30%) of the 20 studies assessed surgical smoke for the presence of viruses, with only 1 study (5%) positively identifying viral DNA in laser-derived smoke. One study (5%) demonstrated bacterial cell culture (Staphylococcus aureus) from a laser plume after surgery. Regarding mutagenesis and malignant spread, one study (5%) reported the mutagenic effect of smoke, and one study (5%) showed the presence of malignant cells in the smoke of a patient undergoing procedures for carcinomatosis. CONCLUSIONS: The potentially carcinogenic components of surgical smoke are sufficiently small to be respirable. Infective and malignant cells are found in the smoke plume, but the full risk of this to the theater staff is unproven. Future work could focus on the long-term consequences of smoke exposure.


Assuntos
Poluentes Ocupacionais do Ar/efeitos adversos , Equipamentos e Provisões Elétricas , Exposição Ocupacional/efeitos adversos , Salas Cirúrgicas , Fumaça/efeitos adversos , Instrumentos Cirúrgicos , Gases , Humanos
9.
Surg Endosc ; 27(5): 1468-77, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23233011

RESUMO

BACKGROUND: The use of simulation for laparoscopic training has led to the development of objective tools for skills assessment. Motion analysis represents one area of focus. This study was designed to assess the evidence for the use of motion analysis as a valid tool for laparoscopic skills assessment. METHODS: Embase, MEDLINE and PubMed were searched using the following domains: (1) motion analysis, (2) validation and (3) laparoscopy. Studies investigating motion analysis as a tool for assessment of laparoscopic skill in general surgery were included. Common endpoints in motion analysis metrics were compared between studies according to a modified form of the Oxford Centre for Evidence-Based Medicine levels of evidence and recommendation. RESULTS: Thirteen studies were included from 2,039 initial papers. Twelve (92.3 %) reported the construct validity of motion analysis across a range of laparoscopic tasks. Of these 12, 5 (41.7 %) evaluated the ProMIS Augmented Reality Simulator, 3 (25 %) the Imperial College Surgical Assessment Device (ICSAD), 2 (16.7 %) the Hiroshima University Endoscopic Surgical Assessment Device (HUESAD), 1 (8.33 %) the Advanced Dundee Endoscopic Psychomotor Tester (ADEPT) and 1 (8.33 %) the Robotic and Video Motion Analysis Software (ROVIMAS). Face validity was reported by 1 (7.7 %) study each for ADEPT and ICSAD. Concurrent validity was reported by 1 (7.7 %) study each for ADEPT, ICSAD and ProMIS. There was no evidence for predictive validity. CONCLUSIONS: Evidence exists to validate motion analysis for use in laparoscopic skills assessment. Valid parameters are time taken, path length and number of hand movements. Future work should concentrate on the conversion of motion data into competency-based scores for trainee feedback.


Assuntos
Competência Clínica , Laparoscopia , Estudos de Tempo e Movimento , Ergonomia/instrumentação , Medicina Baseada em Evidências , Mãos/fisiologia , Humanos , Laparoscopia/educação , Movimento (Física) , Destreza Motora , Avaliação de Resultados em Cuidados de Saúde , Robótica , Software , Instrumentos Cirúrgicos , Estudos de Validação como Assunto , Gravação em Vídeo
10.
Surg Endosc ; 26(11): 3040-52, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22648104

RESUMO

BACKGROUND: Simulation is a useful adjunct to skills-based training. It potentially avoids risk to patients during training and development of basic interventional techniques. This may be of particular relevance in colonoscopy where the learning curve can be long. Several endoscopic devices exist that simulate colonoscopy for training purposes. This study was designed to review the evidence for the validity of these simulators. METHODS: MEDLINE (1947 to present), PubMed, Embase classic + Embase, the metaRegister of Controlled Trials, and the Education Resources Information Center (ERIC) were searched for studies validating colonoscopy simulators. For each study, we recorded the type of simulator used, the tasks assessed, the endpoints reported, and the type of validity measured. Common endpoints between studies were compared, and the evidence was graded. RESULTS: Thirteen studies met the inclusion criteria. Construct validity was reported in five (41.7 %) studies for the Accutouch HT Immersion (cases 1, 3, and 4), four studies (33.3 %) for the GI mentor II (Simbionix) (Modules 1.1, 1.3, 1.7, 2.1, and 5), two studies (16.7 %) for the Olympus Endo Ts-1 2nd Generation, and one study for the Endo X bovine model. Face validity was reported for the Accutouch HT Immersion, the Olympus 2nd Generation, and the KAIST-Ewha. Content validity was reported for the all simulators, excluding the KAIST-Ewha. The only report of criterion validity was for the Endo X bovine model. CONCLUSION: Evidence exists to support the face, content, and construct validity of several virtual reality colonoscopy simulators for specific diagnostic and therapeutic modules with selected endpoints. One study demonstrates content, construct, and criterion validity for an ex vivo animal platform. Further work is needed to demonstrate the criterion validity of all devices.


Assuntos
Colonoscopia/educação , Simulação por Computador , Modelos Anatômicos , Modelos Animais , Animais , Educação Médica/métodos , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA