Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
PLoS One ; 19(3): e0298730, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38483868

RESUMO

INTRODUCTION: A lateral flow rapid diagnostic test (RDT) enables detection of measles specific immunoglobulin M (IgM) antibody in serum, capillary blood, and oral fluid with accuracy consistent with enzyme immunoassay (EIA). The objectives of the study were: 1) to assess measles RDT inter-reader agreement between two clinic staff; 2) to assess the sensitivity and specificity of the measles RDT relative to standard surveillance testing in a low transmission setting; 3) to evaluate the knowledge, attitudes, and practices of staff in clinics using the RDT; and 4) to assess the impact of RDT testing on the measles public health response in Malaysia. MATERIALS AND METHODS: The clinic-based prospective evaluation included all suspected measles cases captured by routine measles surveillance at 34 purposely selected clinics in 15 health districts in Malaysia between September 2019 and June 2020, following day-long regional trainings on RDT use. Following informed consent, four specimens were collected from each suspected case, including those routinely collected for standard surveillance [serum for EIA and throat swabs for quantitative reverse transcriptase polymerase chain reaction (RT-qPCR)] together with capillary blood and oral fluid tested with RDTs during the study. RDT impact was evaluated by comparing the rapidity of measles public health response between the pre-RDT implementation (December 2018 to August 2019) and RDT implementation periods (September 2019 to June 2020). To assess knowledge, attitudes, and practices of RDT use, staff involved in the public health management of measles at the selected sites were surveyed. RESULTS: Among the 436 suspect cases, agreement of direct visual readings of measles RDT devices between two health clinic staff was 99% for capillary blood (k = 0.94) and 97% for oral fluid (k = 0.90) specimens. Of the total, 45 (10%) were positive by measles IgM EIA (n = 44, including five also positive by RT-qPCR) or RT-qPCR only (n = 1), and 38 were positive by RDT (using either capillary blood or oral fluid). Using measles IgM EIA or RT-qPCR as reference, RDT sensitivity using capillary blood was 43% (95% CI: 30%-58%) and specificity was 98% (95% CI: 96%-99%); using oral fluid, sensitivity (26%, 95% CI: 15%-40%) and specificity (97%, 95% CI: 94%-98%) were lower. Nine months after training, RDT knowledge was high among staff involved with the public health management of measles (average quiz score of 80%) and was highest among those who received formal training (88%), followed by those trained during supervisory visits (83%). During the RDT implementation period, the number of days from case confirmation until initiation of public response decreased by about 5 days. CONCLUSION: The measles IgM RDT shows >95% inter-reader agreement, high retention of RDT knowledge, and a more rapid public health response. However, despite ≥95% RDT specificity using capillary blood or oral fluid, RDT sensitivity was <45%. Higher-powered studies using highly specific IgM assays and systematic RT-qPCR for case confirmation are needed to establish the role of RDT in measles elimination settings.


Assuntos
Sarampo , Testes de Diagnóstico Rápido , Humanos , Imunoglobulina M , Malásia/epidemiologia , Sarampo/diagnóstico , Sarampo/epidemiologia , Técnicas Imunoenzimáticas , Sensibilidade e Especificidade
2.
J Infect ; 84(5): 692-700, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35131335

RESUMO

BACKGROUND: There are limited data on immune responses to heterologous COVID-19 immunisation schedules, especially following an extended ≥12-week interval between doses. METHODS: SARS-CoV-2 infection-naïve and previously-infected adults receiving ChAd-BNT (ChAdOx1 nCoV-19, AstraZeneca followed by BNT162b2, Pfizer-BioNTech) or BNT-ChAd as part of the UK national immunisation programme provided blood samples at 30 days and 12 weeks after their second dose. Geometric mean concentrations (GMC) of anti-SARS-CoV-2 spike (S-antibody) and nucleoprotein (N-antibody) IgG antibodies and geometric mean ratios (GMR) were compared with a contemporaneous cohort receiving homologous ChAd-ChAd or BNT-BNT. RESULTS: During March-October 2021, 75,827 individuals were identified as having received heterologous vaccination, 9,489 invited to participate, 1,836 responded (19.3%) and 656 were eligible. In previously-uninfected adults, S-antibody GMC at 30 days post-second dose were lowest for ChAd-ChAd (862 [95% CI, 694 - 1069]) and significantly higher for ChAd-BNT (6233 [5522-7035]; GMR 6.29; [5.04-7.85]; p<0.001), BNT-ChAd (4776 [4066-5610]; GMR 4.55 [3.56-5.81]; p<0.001) and BNT-BNT (5377 [4596-6289]; GMR 5.66 [4.49-7.15]; p<0.001). By 12 weeks after dose two, S-antibody GMC had declined in all groups and remained significantly lower for ChAd-ChAd compared to ChAd-BNT (GMR 5.12 [3.79-6.92]; p<0.001), BNT-ChAd (GMR 4.1 [2.96-5.69]; p<0.001) and BNT-BNT (GMR 6.06 [4.32-8.50]; p<0.001). Previously infected adults had higher S-antibody GMC compared to infection-naïve adults at all time-points and with all vaccine schedules. CONCLUSIONS: These real-world findings demonstrate heterologous schedules with adenoviral-vector and mRNA vaccines are highly immunogenic and may be recommended after a serious adverse reaction to one vaccine product, or to increase programmatic flexibility where vaccine supplies are constrained.


Assuntos
COVID-19 , SARS-CoV-2 , Adulto , Formação de Anticorpos , Vacina BNT162 , COVID-19/prevenção & controle , Vacinas contra COVID-19 , ChAdOx1 nCoV-19 , Inglaterra , Humanos , Imunoglobulina G , Vacinação
3.
Microbiol Spectr ; 10(1): e0078621, 2022 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-34985331

RESUMO

Seroepidemiological studies to monitor antibody kinetics are important for assessing the extent and spread of SARS-CoV-2 in a population. Noninvasive sampling methods are advantageous for reducing the need for venipuncture, which may be a barrier to investigations, particularly in pediatric populations. Oral fluids are obtained by gingiva-crevicular sampling from children and adults and are very well accepted. Enzyme immunoassays (EIAs) based on these samples have acceptable sensitivity and specificity compared to conventional serum-based antibody EIAs and are suitable for population-based surveillance. We describe the development and evaluation of SARS-CoV-2 IgG EIAs using SARS-CoV-2 viral nucleoprotein (NP) and spike (S) proteins in IgG isotype capture format and an indirect receptor-binding-domain (RBD) IgG EIA, intended for use in children as a primary endpoint. All three assays were assessed using a panel of 1,999 paired serum and oral fluids from children and adults participating in school SARS-CoV-2 surveillance studies during and after the first and second pandemic wave in the United Kingdom. The anti-NP IgG capture assay was the best candidate, with an overall sensitivity of 75% (95% confidence interval [CI]: 71 to 79%) and specificity of 99% (95% CI: 78 to 99%) compared with paired serum antibodies. Sensitivity observed in children (80%, 95% CI: 71 to 88%) was higher than that in adults (67%, CI: 60% to 74%). Oral fluid assays (OF) using spike protein and RBD antigens were also 99% specific and achieved reasonable but lower sensitivity in the target population (78%, 95% CI [68% to 86%] and 53%, 95% CI [43% to 64%], respectively). IMPORTANCE We report on the first large-scale assessment of the suitability of oral fluids for detection of SARS-CoV-2 antibody obtained from healthy children attending school. The sample type (gingiva-crevicular fluid, which is a transudate of blood but is not saliva) can be self collected. Although detection of antibodies in oral fluids is less sensitive than that in blood, our study suggests an optimal format for operational use. The laboratory methods we have developed can reliably measure antibodies in children, who are able to take their own samples. Our findings are of immediate practical relevance for use in large-scale seroprevalence studies designed to measure exposure to infection, as they typically require venipuncture. Overall, our data indicate that OF assays based on the detection of SARS-CoV-2 antibodies are a tool suitable for population-based seroepidemiology studies in children and highly acceptable in children and adults, as venipuncture is no longer necessary.


Assuntos
Anticorpos Antivirais/análise , COVID-19/diagnóstico , Líquido do Sulco Gengival/imunologia , Imunoglobulina G/análise , SARS-CoV-2/imunologia , Adolescente , Criança , Pré-Escolar , Humanos , Técnicas Imunoenzimáticas , Lactente , Sensibilidade e Especificidade , Estudos Soroepidemiológicos
4.
Bull World Health Organ ; 89(9): 675-82, 2011 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-21897488

RESUMO

OBJECTIVE: To evaluate the performance of a newly developed point-of-care test (POCT) for the detection of measles-specific IgM antibodies in serum and oral fluid specimens and to assess if measles virus nucleic acid could be recovered from used POCT strips. METHODS: The POCT was used to test 170 serum specimens collected through measles surveillance or vaccination programmes in Ethiopia, Malaysia and the Russian Federation: 69 were positive for measles immunoglobulin M (IgM) antibodies, 74 were positive for rubella IgM antibodies and 7 were positive for both. Also tested were 282 oral fluid specimens from the measles, mumps and rubella (MMR) surveillance programme of the United Kingdom of Great Britain and Northern Ireland. The Microimmune measles IgM capture enzyme immunoassay was the gold standard for comparison. A panel of 24 oral fluids was used to investigate if measles virus haemagglutinin (H) and nucleocapsid (N) genes could be amplified by polymerase chain reaction directly from used POCT strips. FINDINGS: With serum POCT showed a sensitivity and specificity of 90.8% (69/76) and 93.6% (88/94), respectively; with oral fluids, sensitivity and specificity were 90.0% (63/70) and 96.2% (200/208), respectively. Both H and N genes were reliably detected in POCT strips and the N genes could be sequenced for genotyping. Measles virus genes could be recovered from POCT strips after storage for 5 weeks at 20-25 °C. CONCLUSION: The POCT has the sensitivity and specificity required of a field-based test for measles diagnosis. However, its role in global measles control programmes requires further evaluation.


Assuntos
Anticorpos Antivirais/sangue , Imunoglobulina M/sangue , Sarampo/diagnóstico , Morbillivirus/isolamento & purificação , Sistemas Automatizados de Assistência Junto ao Leito/normas , Saliva/virologia , Adolescente , Adulto , Criança , Pré-Escolar , Humanos , Técnicas Imunoenzimáticas , Lactente , Internacionalidade , Sarampo/epidemiologia , Pessoa de Meia-Idade , Nucleocapsídeo/sangue , Nucleocapsídeo/genética , Valor Preditivo dos Testes , Sensibilidade e Especificidade , Adulto Jovem
5.
J Med Virol ; 83(4): 559-67, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21328368

RESUMO

In order to provide specific serological reagents for pandemic influenza A/H1N1 2009 virus, monoclonal antibodies (Mabs) to recombinant haemagglutinin component HA1 (rHA1) were generated after fusing spleen cells from a mouse immunized with rHA1 protein derived from influenza strain A/California/06/09 H1N1 with a mouse myeloma cell line. Five hybridoma clones secreting Mabs specific for the rHA1 protein derived from pandemic influenza A/H1N1 2009 and not for rHA1 from seasonal H1N1 influenza strains A/Brisbane/59/07 and A/Solomon Islands/03/06 were identified by EIA. Mabs 7H4, 9A4, and 9E12 were reactive in Western blots with full length rHA and/or rHA1 subunit derived from A/California/06/09 strain. Only Mab 1F5 inhibited haemagglutination of turkey red blood cells with recombinant NIBRG-121 virus derived from A/California/07/09, but did not react in Western blots. Immunostaining of MDCK cells infected with NIBRG-121 was localized to the membrane/cytoplasm for four of the reactive Mabs. The differing reactivity of the Mabs in Western blots, immunostaining, EIA, and haemagglutination inhibition assay suggest that at least four of the five Mabs recognize different epitopes on HA1 of the pandemic influenza A/H1N1 2009 virus. Ferret antisera to pandemic influenza A/H1N1 2009 (A/England/195/09 and A/California/07/09 strains) and sera from human subjects vaccinated with Influenza A (H1N1) 2009 Monovalent Vaccine (CELTURA®, Novartis Vaccines, Germany), inhibit binding of 1F5-HRP to biotinylated rHA1 derived from A/California/06/09 in a competitive EIA, suggesting that the epitope recognized by this Mab also evokes an antibody response in infected ferrets and vaccinated humans.


Assuntos
Anticorpos Monoclonais/isolamento & purificação , Anticorpos Antivirais/isolamento & purificação , Glicoproteínas de Hemaglutininação de Vírus da Influenza/imunologia , Vírus da Influenza A Subtipo H1N1/imunologia , Virologia/métodos , Animais , Western Blotting , Furões , Testes de Inibição da Hemaglutinação , Humanos , Técnicas Imunoenzimáticas , Camundongos , Camundongos Endogâmicos BALB C , Testes Sorológicos/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA