Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
1.
Magn Reson Med ; 86(4): 1829-1844, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33973674

RESUMO

PURPOSE: We introduce a novel, generalized tracer kinetic model selection framework to quantify microvascular characteristics of liver and tumor tissue in gadoxetate-enhanced dynamic contrast-enhanced MRI (DCE-MRI). METHODS: Our framework includes a hierarchy of nested models, from which physiological parameters are derived in 2 regimes, corresponding to the active transport and free diffusion of gadoxetate. We use simulations to show the sensitivity of model selection and parameter estimation to temporal resolution, time-series duration, and noise. We apply the framework in 8 healthy volunteers (time-series duration up to 24 minutes) and 10 patients with hepatocellular carcinoma (6 minutes). RESULTS: The active transport regime is preferred in 98.6% of voxels in volunteers, 82.1% of patients' non-tumorous liver, and 32.2% of tumor voxels. Interpatient variations correspond to known co-morbidities. Simulations suggest both datasets have sufficient temporal resolution and signal-to-noise ratio, while patient data would be improved by using a time-series duration of at least 12 minutes. CONCLUSIONS: In patient data, gadoxetate exhibits different kinetics: (a) between liver and tumor regions and (b) within regions due to liver disease and/or tumor heterogeneity. Our generalized framework selects a physiological interpretation at each voxel, without preselecting a model for each region or duplicating time-consuming optimizations for models with identical functional forms.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Carcinoma Hepatocelular/diagnóstico por imagem , Meios de Contraste , Gadolínio DTPA , Humanos , Fígado/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Imageamento por Ressonância Magnética
2.
BMC Cancer ; 21(1): 354, 2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-33794823

RESUMO

BACKGROUND: Patients with metastatic colorectal cancer are treated with cytotoxic chemotherapy supplemented by molecularly targeted therapies. There is a critical need to define biomarkers that can optimise the use of these therapies to maximise efficacy and avoid unnecessary toxicity. However, it is important to first define the changes in potential biomarkers following cytotoxic chemotherapy alone. This study reports the impact of standard cytotoxic chemotherapy across a range of circulating and imaging biomarkers. METHODS: A single-centre, prospective, biomarker-driven study. Eligible patients included those diagnosed with colorectal cancer with liver metastases that were planned to receive first line oxaliplatin plus 5-fluorouracil or capecitabine. Patients underwent paired blood sampling and magnetic resonance imaging (MRI), and biomarkers were associated with progression-free survival (PFS) and overall survival (OS). RESULTS: Twenty patients were recruited to the study. Data showed that chemotherapy significantly reduced the number of circulating tumour cells as well as the circulating concentrations of Ang1, Ang2, VEGF-A, VEGF-C and VEGF-D from pre-treatment to cycle 2 day 2. The changes in circulating concentrations were not associated with PFS or OS. On average, the MRI perfusion/permeability parameter, Ktrans, increased in response to cytotoxic chemotherapy from pre-treatment to cycle 2 day 2 and this increase was associated with worse OS (HR 1.099, 95%CI 1.01-1.20, p = 0.025). CONCLUSIONS: In patients diagnosed with colorectal cancer with liver metastases, treatment with standard chemotherapy changes cell- and protein-based biomarkers, although these changes are not associated with survival outcomes. In contrast, the imaging biomarker, Ktrans, offers promise to direct molecularly targeted therapies such as anti-angiogenic agents.


Assuntos
Biomarcadores Tumorais/metabolismo , Capecitabina/uso terapêutico , Fluoruracila/uso terapêutico , Oxaliplatina/uso terapêutico , Idoso , Capecitabina/farmacologia , Feminino , Fluoruracila/farmacologia , Humanos , Masculino , Metástase Neoplásica , Oxaliplatina/farmacologia , Estudos Prospectivos
3.
Cancers (Basel) ; 13(2)2021 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-33440685

RESUMO

Imaging biomarkers require technical, biological, and clinical validation to be translated into robust tools in research or clinical settings. This study contributes to the technical validation of radiomic features from magnetic resonance imaging (MRI) by evaluating the repeatability of features from four MR sequences: pre-contrast T1- and T2-weighted images, pre-contrast quantitative T1 maps (qT1), and contrast-enhanced T1-weighted images. Fifty-one patients with colorectal cancer liver metastases were scanned twice, up to 7 days apart. Repeatability was quantified using the intraclass correlation coefficient (ICC) and repeatability coefficient (RC), and the impact of non-Gaussian feature distributions and image normalisation was evaluated. Most radiomic features had non-Gaussian distributions, but Box-Cox transformations enabled ICCs and RCs to be calculated appropriately for an average of 97% of features across sequences. ICCs ranged from 0.30 to 0.99, with volume and other shape features tending to be most repeatable; volume ICC > 0.98 for all sequences. 19% of features from non-normalised images exhibited significantly different ICCs in pair-wise sequence comparisons. Normalisation tended to increase ICCs for pre-contrast T1- and T2-weighted images, and decrease ICCs for qT1 maps. RCs tended to vary more between sequences than ICCs, showing that evaluations of feature performance depend on the chosen metric. This work suggests that feature-specific repeatability, from specific combinations of MR sequence and pre-processing steps, should be evaluated to select robust radiomic features as biomarkers in specific studies. In addition, as different repeatability metrics can provide different insights into a specific feature, consideration of the appropriate metric should be taken in a study-specific context.

4.
Magn Reson Med ; 84(3): 1250-1263, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32057115

RESUMO

PURPOSE: MRI biomarkers of tumor response to treatment are typically obtained from parameters derived from a model applied to pre-treatment and post-treatment data. However, as tumors are spatially and temporally heterogeneous, different models may be necessary in different tumor regions, and model suitability may change over time. This work evaluates how the suitability of two diffusion-weighted (DW) MRI models varies spatially within tumors at the voxel level and in response to radiotherapy, potentially allowing inference of qualitatively different tumor microenvironments. METHODS: DW-MRI data were acquired in CT26 subcutaneous allografts before and after radiotherapy. Restricted and time-independent diffusion models were compared, with regions well-described by the former hypothesized to reflect cellular tissue, and those well-described by the latter expected to reflect necrosis or oedema. Technical and biological validation of the percentage of tissue described by the restricted diffusion microstructural model (termed %MM) was performed through simulations and histological comparison. RESULTS: Spatial and radiotherapy-related variation in model suitability was observed. %MM decreased from a mean of 64% at baseline to 44% 6 days post-radiotherapy in the treated group. %MM correlated negatively with the percentage of necrosis from histology, but overestimated it due to noise. Within MM regions, microstructural parameters were sensitive to radiotherapy-induced changes. CONCLUSIONS: There is spatial and radiotherapy-related variation in different models' suitability for describing diffusion in tumor tissue, suggesting the presence of different and changing tumor sub-regions. The biological and technical validation of the proposed %MM cancer imaging biomarker suggests it correlates with, but overestimates, the percentage of necrosis.


Assuntos
Imagem de Difusão por Ressonância Magnética , Neoplasias , Difusão , Humanos , Imageamento por Ressonância Magnética , Neoplasias/diagnóstico por imagem , Neoplasias/radioterapia , Microambiente Tumoral
5.
Clin Cancer Res ; 25(13): 3818-3829, 2019 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-31053599

RESUMO

PURPOSE: Hypoxia is associated with poor prognosis and is predictive of poor response to cancer treatments, including radiotherapy. Developing noninvasive biomarkers that both detect hypoxia prior to treatment and track change in tumor hypoxia following treatment is required urgently. EXPERIMENTAL DESIGN: We evaluated the ability of oxygen-enhanced MRI (OE-MRI) to map and quantify therapy-induced changes in tumor hypoxia by measuring oxygen-refractory signals in perfused tissue (perfused Oxy-R). Clinical first-in-human study in patients with non-small cell lung cancer (NSCLC) was performed alongside preclinical experiments in two xenograft tumors (Calu6 NSCLC model and U87 glioma model). RESULTS: MRI perfused Oxy-R tumor fraction measurement of hypoxia was validated with ex vivo tissue pathology in both xenograft models. Calu6 and U87 experiments showed that MRI perfused Oxy-R tumor volume was reduced relative to control following single fraction 10-Gy radiation and fractionated chemoradiotherapy (P < 0.001) due to both improved perfusion and reduced oxygen consumption rate. Next, evaluation of 23 patients with NSCLC showed that OE-MRI was clinically feasible and that tumor perfused Oxy-R volume is repeatable [interclass correlation coefficient: 0.961 (95% CI, 0.858-0.990); coefficient of variation: 25.880%]. Group-wise perfused Oxy-R volume was reduced at 14 days following start of radiotherapy (P = 0.015). OE-MRI detected between-subject variation in hypoxia modification in both xenograft and patient tumors. CONCLUSIONS: These findings support applying OE-MRI biomarkers to monitor hypoxia modification, to stratify patients in clinical trials of hypoxia-modifying therapies, to identify patients with hypoxic tumors that may fail treatment with immunotherapy, and to guide adaptive radiotherapy by mapping regional hypoxia.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/metabolismo , Hipóxia/diagnóstico por imagem , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/metabolismo , Imageamento por Ressonância Magnética , Oxigênio/metabolismo , Animais , Biomarcadores , Carcinoma Pulmonar de Células não Pequenas/patologia , Carcinoma Pulmonar de Células não Pequenas/radioterapia , Linhagem Celular Tumoral , Modelos Animais de Doenças , Humanos , Aumento da Imagem , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/radioterapia , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/normas , Camundongos , Medicina de Precisão/métodos , Medicina de Precisão/normas , Fluxo Sanguíneo Regional , Reprodutibilidade dos Testes , Carga Tumoral , Ensaios Antitumorais Modelo de Xenoenxerto
6.
Nat Commun ; 9(1): 4672, 2018 11 07.
Artigo em Inglês | MEDLINE | ID: mdl-30405103

RESUMO

Oncological use of anti-angiogenic VEGF inhibitors has been limited by the lack of informative biomarkers. Previously we reported circulating Tie2 as a vascular response biomarker for bevacizumab-treated ovarian cancer patients. Using advanced MRI and circulating biomarkers we have extended these findings in metastatic colorectal cancer (n = 70). Bevacizumab (10 mg/kg) was administered to elicit a biomarker response, followed by FOLFOX6-bevacizumab until disease progression. Bevacizumab induced a correlation between Tie2 and the tumor vascular imaging biomarker, Ktrans (R:-0.21 to 0.47) implying that Tie2 originated from the tumor vasculature. Tie2 trajectories were independently associated with pre-treatment tumor vascular characteristics, tumor response, progression free survival (HR for progression = 3.01, p = 0.00014; median PFS 248 vs. 348 days p = 0.0008) and the modeling of progressive disease (p < 0.0001), suggesting that Tie2 should be monitored clinically to optimize VEGF inhibitor use. A vascular response is defined as a 30% reduction in Tie2; vascular progression as a 40% increase in Tie2 above the nadir. Tie2 is the first, validated, tumor vascular response biomarker for VEGFi.


Assuntos
Inibidores da Angiogênese/uso terapêutico , Biomarcadores Tumorais/sangue , Neoplasias Colorretais/sangue , Neoplasias Colorretais/secundário , Receptor TIE-2/sangue , Fator A de Crescimento do Endotélio Vascular/antagonistas & inibidores , Adulto , Idoso , Angiopoietina-2/metabolismo , Bevacizumab/farmacologia , Bevacizumab/uso terapêutico , Neoplasias Colorretais/irrigação sanguínea , Neoplasias Colorretais/tratamento farmacológico , Progressão da Doença , Intervalo Livre de Doença , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Modelos Biológicos , Neovascularização Patológica/sangue , Prognóstico , Fator A de Crescimento do Endotélio Vascular/metabolismo
7.
Radiology ; 288(3): 739-747, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29869970

RESUMO

Purpose To cross-validate T1-weighted oxygen-enhanced (OE) MRI measurements of tumor hypoxia with intrinsic susceptibility MRI measurements and to demonstrate the feasibility of translation of the technique for patients. Materials and Methods Preclinical studies in nine 786-0-R renal cell carcinoma (RCC) xenografts and prospective clinical studies in eight patients with RCC were performed. Longitudinal relaxation rate changes (∆R1) after 100% oxygen inhalation were quantified, reflecting the paramagnetic effect on tissue protons because of the presence of molecular oxygen. Native transverse relaxation rate (R2*) and oxygen-induced R2* change (∆R2*) were measured, reflecting presence of deoxygenated hemoglobin molecules. Median and voxel-wise values of ∆R1 were compared with values of R2* and ∆R2*. Tumor regions with dynamic contrast agent-enhanced MRI perfusion, refractory to signal change at OE MRI (referred to as perfused Oxy-R), were distinguished from perfused oxygen-enhancing (perfused Oxy-E) and nonperfused regions. R2* and ∆R2* values in each tumor subregion were compared by using one-way analysis of variance. Results Tumor-wise and voxel-wise ∆R1 and ∆R2* comparisons did not show correlative relationships. In xenografts, parcellation analysis revealed that perfused Oxy-R regions had faster native R2* (102.4 sec-1 vs 81.7 sec-1) and greater negative ∆R2* (-22.9 sec-1 vs -5.4 sec-1), compared with perfused Oxy-E and nonperfused subregions (all P < .001), respectively. Similar findings were present in human tumors (P < .001). Further, perfused Oxy-R helped identify tumor hypoxia, measured at pathologic analysis, in both xenografts (P = .002) and human tumors (P = .003). Conclusion Intrinsic susceptibility biomarkers provide cross validation of the OE MRI biomarker perfused Oxy-R. Consistent relationship to pathologic analyses was found in xenografts and human tumors, demonstrating biomarker translation. Published under a CC BY 4.0 license. Online supplemental material is available for this article.


Assuntos
Carcinoma de Células Renais/fisiopatologia , Hipóxia/fisiopatologia , Aumento da Imagem/métodos , Neoplasias Renais/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Animais , Biomarcadores , Carcinoma de Células Renais/complicações , Carcinoma de Células Renais/diagnóstico por imagem , Modelos Animais de Doenças , Estudos de Viabilidade , Feminino , Humanos , Hipóxia/complicações , Hipóxia/diagnóstico por imagem , Rim/diagnóstico por imagem , Rim/patologia , Rim/fisiopatologia , Neoplasias Renais/complicações , Neoplasias Renais/diagnóstico por imagem , Masculino , Camundongos , Pessoa de Meia-Idade , Oxigênio , Estudos Prospectivos , Reprodutibilidade dos Testes
8.
Magn Reson Med ; 79(4): 2236-2245, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-28856728

RESUMO

PURPOSE: Previous work has shown that combining dynamic contrast-enhanced (DCE)-MRI and oxygen-enhanced (OE)-MRI binary enhancement maps can identify tumor hypoxia. The current work proposes a novel, data-driven method for mapping tissue oxygenation and perfusion heterogeneity, based on clustering DCE/OE-MRI data. METHODS: DCE-MRI and OE-MRI were performed on nine U87 (glioblastoma) and seven Calu6 (non-small cell lung cancer) murine xenograft tumors. Area under the curve and principal component analysis features were calculated and clustered separately using Gaussian mixture modelling. Evaluation metrics were calculated to determine the optimum feature set and cluster number. Outputs were quantitatively compared with a previous non data-driven approach. RESULTS: The optimum method located six robustly identifiable clusters in the data, yielding tumor region maps with spatially contiguous regions in a rim-core structure, suggesting a biological basis. Mean within-cluster enhancement curves showed physiologically distinct, intuitive kinetics of enhancement. Regions of DCE/OE-MRI enhancement mismatch were located, and voxel categorization agreed well with the previous non data-driven approach (Cohen's kappa = 0.61, proportional agreement = 0.75). CONCLUSION: The proposed method locates similar regions to the previous published method of binarization of DCE/OE-MRI enhancement, but renders a finer segmentation of intra-tumoral oxygenation and perfusion. This could aid in understanding the tumor microenvironment and its heterogeneity. Magn Reson Med 79:2236-2245, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.


Assuntos
Imageamento por Ressonância Magnética , Neoplasias/diagnóstico por imagem , Neoplasias/patologia , Hipóxia Tumoral , Microambiente Tumoral , Algoritmos , Animais , Área Sob a Curva , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Análise por Conglomerados , Glioblastoma/diagnóstico por imagem , Humanos , Hipóxia , Interpretação de Imagem Assistida por Computador , Processamento de Imagem Assistida por Computador , Neoplasias Pulmonares/diagnóstico por imagem , Camundongos , Transplante de Neoplasias , Distribuição Normal , Oxigênio/metabolismo , Perfusão , Análise de Componente Principal , Reprodutibilidade dos Testes , Software
9.
Magn Reson Imaging ; 46: 98-105, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29154898

RESUMO

BACKGROUND: Solid tumours exhibit enhanced vessel permeability and fenestrated endothelium to varying degree, but it is unknown how this varies in patients between and within tumour types. Dynamic contrast-enhanced (DCE) MRI provides a measure of perfusion and permeability, the transfer constant Ktrans, which could be employed for such comparisons in patients. AIM: To test the hypothesis that different tumour types exhibit systematically different Ktrans. MATERIALS AND METHODS: DCE-MRI data were retrieved from 342 solid tumours in 230 patients. These data were from 18 previous studies, each of which had had a different analysis protocol. All data were reanalysed using a standardised workflow using an extended Tofts model. A model of the posterior density of median Ktrans was built assuming a log-normal distribution and fitting a simple Bayesian hierarchical model. RESULTS: 12 histological tumour types were included. In glioma, median Ktrans was 0.016min-1 and for non-glioma tumours, median Ktrans ranged from 0.10 (cervical) to 0.21min-1 (prostate metastatic to bone). The geometric mean (95% CI) across all the non-glioma tumours was 0.15 (0.05, 0.45)min-1. There was insufficient separation between the posterior densities to be able to predict the Ktrans value of a tumour given the tumour type, except that the median Ktrans for gliomas was below 0.05min-1 with 80% probability, and median Ktrans measurements for the remaining tumour types were between 0.05 and 0.4min-1 with 80% probability. CONCLUSION: With the exception of glioma, our hypothesis that different tumour types exhibit different Ktrans was not supported. Studies in which tumour permeability is believed to affect outcome should not simply seek tumour types thought to exhibit high permeability. Instead, Ktrans is an idiopathic parameter, and, where permeability is important, Ktrans should be measured in each tumour to personalise that treatment.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Meios de Contraste/química , Glioma/diagnóstico por imagem , Imageamento por Ressonância Magnética , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Teorema de Bayes , Biomarcadores , Neoplasias Encefálicas/patologia , Permeabilidade Capilar , Feminino , Glioma/patologia , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Modelos Estatísticos , Perfusão , Imagens de Fantasmas , Reprodutibilidade dos Testes , Estudos Retrospectivos , Razão Sinal-Ruído , Adulto Jovem
10.
Cancer Chemother Pharmacol ; 72(6): 1343-52, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24141375

RESUMO

BACKGROUND: 4-(N-(S-glutathionylacetyl)amino) phenylarsenoxide (GSAO) is a water-soluble mitochondrial toxin that binds to adenine nucleotide translocase in the inner mitochondrial membrane, thereby targeting cell proliferation. This phase 1 study investigated safety, dose-limiting toxicities (DLTs), maximum tolerated dose (MTD) and pharmacokinetics (PK) of GSAO as a daily 1-h infusion for 5 days a week for 2 weeks in every three. Pharmacodynamics of GSAO was evaluated by dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) and circulating markers of angiogenesis. METHODS: Patients with advanced solid tumours received GSAO in a dose-escalation trial according to a standard '3 + 3' design that was guided by toxicity and, for the final dose escalation, by arsenic PK data. RESULTS: A total of 34 patients were treated with GSAO across 9 dose levels (1.3-44.0 mg/m(2)). Treatment was well tolerated with few adverse events. An additional three patients were enrolled at the 12.4 mg/m(2) dose level following a DLT of derangement of liver function tests (grade 4). At the 44.0 mg/m(2) dose level, two out of three patients had DLTs (reversible encephalopathy; paroxysmal atrial fibrillation). CONCLUSIONS: The MTD of GSAO was 22.0 mg/m(2)/day. There was no biomarker evidence from DCE-MRI or circulating markers of angiogenesis of an anti-vascular effect of GSAO.


Assuntos
Antineoplásicos/administração & dosagem , Arsenicais/administração & dosagem , Glutationa/análogos & derivados , Neoplasias/tratamento farmacológico , Adulto , Idoso , Antineoplásicos/efeitos adversos , Antineoplásicos/farmacocinética , Arsenicais/efeitos adversos , Arsenicais/farmacocinética , Proliferação de Células/efeitos dos fármacos , Relação Dose-Resposta a Droga , Feminino , Glutationa/administração & dosagem , Glutationa/efeitos adversos , Glutationa/farmacocinética , Humanos , Infusões Intravenosas , Testes de Função Hepática , Imageamento por Ressonância Magnética , Masculino , Dose Máxima Tolerável , Pessoa de Meia-Idade , Neoplasias/irrigação sanguínea , Neoplasias/patologia , Neovascularização Patológica/patologia
11.
J Magn Reson Imaging ; 35(1): 196-203, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21987457

RESUMO

PURPOSE: To evaluate the Akaike information criterion (AIC) model selection technique as a method for detecting differences in microvascular characteristics between tumorous and non-tumor liver tissue. MATERIALS AND METHODS: The AIC was applied to six patient datasets with liver metastases to determine, on a per voxel basis, which of two physiologically plausible candidate models gave a more appropriate description of the data. The dual-input single-compartment Materne model, extended to incorporate a novel portal input function estimation method, was chosen to represent liver tissue and the single-input dual-compartment extended Kety model was used for tumor. RESULTS: Median AIC probabilities when comparing tumor versus liver and tumor versus tumor-margins were significantly different (P ≤ 0.01) in five of the six patient datasets. Comparisons between tumor margins and liver regions were significantly different in four datasets. Median AIC probabilities selected for the extended Kety model in all tumor regions, with the Materne model being progressively more probable through tumor margins into liver. CONCLUSION: We present a viable method for assessing the spatially varying microvascular characteristics of tumor-bearing livers, with possible applications in lesion detection, assessment of tumor invasion, and measurement of drug efficacy.


Assuntos
Meios de Contraste/farmacologia , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/patologia , Fígado/patologia , Imageamento por Ressonância Magnética/métodos , Feminino , Humanos , Imageamento Tridimensional , Neoplasias Hepáticas/secundário , Microcirculação , Modelos Estatísticos , Metástase Neoplásica , Imagens de Fantasmas , Probabilidade , Estudos Retrospectivos , Software
12.
Magn Reson Med ; 64(2): 595-603, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20665802

RESUMO

The purpose of this study was to determine the impact of water exchange on tracer kinetic parameter estimates derived from T(1)-weighted dynamic contrast-enhanced (DCE)-MRI data using a direct quantitative comparison with DCE-CT. Data were acquired from 12 patients with bladder cancer who underwent DCE-CT followed by DCE-MRI within a week. A two-compartment tracer kinetic model was fitted to the CT data, and two versions of the same model with modifications to account for the fast exchange and no exchange limits of water exchange were fitted to the MR data. The two-compartment tracer kinetic model provided estimates of the fractional plasma volume (v(p)), the extravascular extracellular space fraction (v(e)), plasma perfusion (F(p)), and the microvascular permeability surface area product. Our findings suggest that DCE-CT is an appropriate reference for DCE-MRI in bladder cancers as the only significant difference found between CT and MR parameter estimates were the no exchange limit estimates of v(p) (P = 0.002). These results suggest that although water exchange between the intracellular and extravascular-extracellular space has a negligible effect on DCE-MRI, vascular-extravascular-extracellular space water exchange may be more important.


Assuntos
Água Corporal/metabolismo , Gadolínio DTPA/farmacocinética , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Neoplasias da Bexiga Urinária/diagnóstico , Neoplasias da Bexiga Urinária/metabolismo , Idoso , Idoso de 80 Anos ou mais , Humanos , Cinética , Masculino , Taxa de Depuração Metabólica , Pessoa de Meia-Idade , Projetos Piloto
13.
Clin Cancer Res ; 15(21): 6674-82, 2009 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-19861458

RESUMO

PURPOSE: Little is known concerning the onset, duration, and magnitude of direct therapeutic effects of anti-vascular endothelial growth factor (VEGF) therapies. Such knowledge would help guide the rational development of targeted therapeutics from bench to bedside and optimize use of imaging technologies that quantify tumor function in early-phase clinical trials. EXPERIMENTAL DESIGN: Preclinical studies were done using ex vivo microcomputed tomography and in vivo ultrasound imaging to characterize tumor vasculature in a human HM-7 colorectal xenograft model treated with the anti-VEGF antibody G6-31. Clinical evaluation was by quantitative magnetic resonance imaging in 10 patients with metastatic colorectal cancer treated with bevacizumab. RESULTS: Microcomputed tomography experiments showed reduction in perfused vessels within 24 to 48 h of G6-31 drug administration (P

Assuntos
Inibidores da Angiogênese/uso terapêutico , Anticorpos Monoclonais/uso terapêutico , Neoplasias Colorretais/irrigação sanguínea , Neoplasias Colorretais/tratamento farmacológico , Diagnóstico por Imagem , Fator A de Crescimento do Endotélio Vascular/imunologia , Adolescente , Animais , Anticorpos Monoclonais/farmacologia , Anticorpos Monoclonais Humanizados , Bevacizumab , Linhagem Celular Tumoral , Sistemas de Liberação de Medicamentos , Feminino , Humanos , Camundongos , Camundongos Nus , Neovascularização Patológica/tratamento farmacológico , Ensaios Antitumorais Modelo de Xenoenxerto
14.
Magn Reson Med ; 62(2): 488-99, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19466747

RESUMO

Dynamic contrast-enhanced MRI is becoming a standard tool for imaging-based trials of anti-vascular/angiogenic agents in cancer. So far, however, biomarkers derived from DCE-MRI parameter maps have largely neglected the fact that the maps have spatial structure and instead focussed on distributional summary statistics. Such statistics-e.g., biomarkers based on median values-neglect the spatial arrangement of parameters, which may carry important diagnostic and prognostic information. This article describes two types of heterogeneity biomarker that are sensitive to both parameter values and their spatial arrangement. Methods based on Rényi fractal dimensions and geometrical properties are developed, both of which attempt to describe the complexity of DCE-MRI parameter maps. Experiments using simulated data show that the proposed biomarkers are sensitive to changes that distribution-based summary statistics cannot detect and demonstrate that heterogeneity biomarkers could be applied in the drug trial setting. An experiment using 23 DCE-MRI parameter maps of gliomas-a class of tumour that is graded on the basis of heterogeneity-shows that the proposed heterogeneity biomarkers are able to differentiate between low- and high-grade tumours.


Assuntos
Neoplasias Encefálicas/diagnóstico , Encéfalo/patologia , Gadolínio DTPA , Glioma/diagnóstico , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Reconhecimento Automatizado de Padrão/métodos , Algoritmos , Meios de Contraste , Fractais , Humanos , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/instrumentação , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
15.
Int J Radiat Oncol Biol Phys ; 75(4): 1209-15, 2009 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-19327904

RESUMO

PURPOSE: There is considerable interest in developing non-invasive methods of mapping tumor hypoxia. Changes in tissue oxygen concentration produce proportional changes in the magnetic resonance imaging (MRI) longitudinal relaxation rate (R(1)). This technique has been used previously to evaluate oxygen delivery to healthy tissues and is distinct from blood oxygenation level-dependent (BOLD) imaging. Here we report application of this method to detect alteration in tumor oxygenation status. METHODS AND MATERIALS: Ten patients with advanced cancer of the abdomen and pelvis underwent serial measurement of tumor R(1) while breathing medical air (21% oxygen) followed by 100% oxygen (oxygen-enhanced MRI). Gadolinium-based dynamic contrast-enhanced MRI was then performed to compare the spatial distribution of perfusion with that of oxygen-induced DeltaR(1). RESULTS: DeltaR(1) showed significant increases of 0.021 to 0.058 s(-1) in eight patients with either locally recurrent tumor from cervical and hepatocellular carcinomas or metastases from ovarian and colorectal carcinomas. In general, there was congruency between perfusion and oxygen concentration. However, regional mismatch was observed in some tumor cores. Here, moderate gadolinium uptake (consistent with moderate perfusion) was associated with low area under the DeltaR(1) curve (consistent with minimal increase in oxygen concentration). CONCLUSIONS: These results provide evidence that oxygen-enhanced longitudinal relaxation can monitor changes in tumor oxygen concentration. The technique shows promise in identifying hypoxic regions within tumors and may enable spatial mapping of change in tumor oxygen concentration.


Assuntos
Neoplasias Abdominais/metabolismo , Hipóxia Celular/fisiologia , Imageamento por Ressonância Magnética/métodos , Oxigênio/metabolismo , Adenocarcinoma/metabolismo , Adulto , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Carcinoma Hepatocelular/metabolismo , Carcinoma de Células Escamosas/metabolismo , Meios de Contraste , Feminino , Gadolínio , Humanos , Neoplasias Hepáticas/metabolismo , Masculino , Pessoa de Meia-Idade , Omento , Neoplasias Ovarianas , Oxigênio/administração & dosagem , Neoplasias Pélvicas/metabolismo , Neoplasias Peritoneais/metabolismo
16.
Magn Reson Med ; 61(1): 75-83, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19097212

RESUMO

Magnetic resonance imaging has shown promise for evaluating tissue oxygenation. In this study differences in the tissue longitudinal relaxation rate (R(1)) and effective transverse relaxation rate (R(*)(2)), induced by inhalation of pure oxygen and carbogen, were evaluated in 10 healthy subjects. Significant reductions in R(1) were demonstrated following both oxygen and carbogen inhalation in the spleen (both P < 0.001), liver (P = 0.002 air vs. oxygen; P = 0.001 air vs. carbogen), skeletal muscle (both P < 0.001), and renal cortex (P = 0.005 air vs. oxygen; P = 0.008 air vs. carbogen). No significant change in R(*)(2) occurred following pure oxygen in any organ. However, a significant increase in R(*)(2) was observed in the spleen (P < 0.001), liver (P = 0.001), skeletal muscle (P = 0.026), and renal cortex (P = 0.001) following carbogen inhalation, an opposite effect to that observed in many studies of tumor pathophysiology. Changes in R(1) and R(*)(2) were independent of the gas administration order in the spleen and skeletal muscle. These findings suggest that the R(1) and R(*)(2) responses to hyperoxic gases are independent biomarkers of oxygen physiology.


Assuntos
Algoritmos , Dióxido de Carbono/administração & dosagem , Dióxido de Carbono/farmacocinética , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Oxigênio/administração & dosagem , Oxigênio/farmacocinética , Reconhecimento Automatizado de Padrão/métodos , Administração por Inalação , Adulto , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Taxa de Depuração Metabólica , Especificidade de Órgãos , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Distribuição Tecidual
17.
Magn Reson Med ; 58(5): 1010-9, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17969122

RESUMO

Dynamic contrast-enhanced MRI (DCE-MRI) time series data are subject to unavoidable physiological motion during acquisition (e.g., due to breathing) and this motion causes significant errors when fitting tracer kinetic models to the data, particularly with voxel-by-voxel fitting approaches. Motion correction is problematic, as contrast enhancement introduces new features into postcontrast images and conventional registration similarity measures cannot fully account for the increased image information content. A methodology is presented for tracer kinetic model-driven registration that addresses these problems by explicitly including a model of contrast enhancement in the registration process. The iterative registration procedure is focused on a tumor volume of interest (VOI), employing a three-dimensional (3D) translational transformation that follows only tumor motion. The implementation accurately removes motion corruption in a DCE-MRI software phantom and it is able to reduce model fitting errors and improve localization in 3D parameter maps in patient data sets that were selected for significant motion problems. Sufficient improvement was observed in the modeling results to salvage clinical trial DCE-MRI data sets that would otherwise have to be rejected due to motion corruption.


Assuntos
Imageamento por Ressonância Magnética/métodos , Modelos Teóricos , Meios de Contraste , Humanos , Cinética
18.
Magn Reson Med ; 58(3): 490-6, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17763345

RESUMO

Molecular oxygen has been previously shown to shorten longitudinal relaxation time (T1) in the spleen and renal cortex, but not in the liver or fat. In this study, the magnitude and temporal evolution of this effect were investigated. Medical air, oxygen, and carbogen (95% oxygen/5% CO2) were administered sequentially in 16 healthy volunteers. T1 maps were acquired using spoiled gradient echo sequences (TR=3.5 ms, TE=0.9 ms, alpha=2 degrees/8 degrees/17 degrees) with six acquisitions on air, 12 on oxygen, 12 on carbogen, and six to 12 back on air. Mean T1 values and change in relaxation rate were compared between each phase of gas inhalation in the liver, spleen, skeletal muscle, renal cortex, and fat by one-way analysis of variance. Oxygen-induced T1-shortening occurred in the liver in fasted subjects (P<0.001) but not in non-fasted subjects (P=0.244). T1-shortening in spleen and renal cortex (both P<0.001) were greater than previously reported. Carbogen induced conflicting responses in different organs, suggesting a complex relationship with organ vasculature. Shortening of tissue T1 by oxygen is more pronounced and more complex than previously recognized. The effect may be useful as a biomarker of arterial flow and oxygen delivery to vascular beds.


Assuntos
Abdome/irrigação sanguínea , Dióxido de Carbono/administração & dosagem , Imageamento por Ressonância Magnética/métodos , Oxigênio/administração & dosagem , Administração por Inalação , Adulto , Artérias/fisiologia , Jejum/fisiologia , Feminino , Humanos , Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Córtex Renal/irrigação sanguínea , Fígado/irrigação sanguínea , Masculino , Músculo Esquelético/irrigação sanguínea , Oxigênio/sangue , Consumo de Oxigênio/fisiologia , Fluxo Sanguíneo Regional/fisiologia , Baço/irrigação sanguínea , Gordura Subcutânea Abdominal/irrigação sanguínea
19.
Clin Cancer Res ; 13(7): 2128-35, 2007 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-17404096

RESUMO

PURPOSE: A fully human monoclonal antibody to anti-alpha(v) integrins (CNTO 95) has been shown to inhibit angiogenesis and tumor growth in preclinical studies. We assessed the safety and pharmacokinetics of CNTO 95 in patients with advanced refractory solid tumors. EXPERIMENTAL DESIGN: In this phase I trial, CNTO 95 (0.1, 0.3, 1.0, 3.0, and 10.0 mg/kg) was infused on days 0, 28, 35, and 42, and clinical assessments, dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI), and [(18)F]-2-fluorodeoxyglucose positron emission tomography (FDG-PET) were done. Patients achieving stable disease or better were eligible for extended dosing every 3 weeks for up to 12 months. RESULTS: Among the 24 enrolled patients, CNTO 95 was associated with one episode of grade III and four episodes of grade II infusion-related fever (all responded to acetaminophen). Of the six patients who received extended dosing, one patient (10.0 mg/kg), with cutaneous angiosarcoma, had a 9-month partial response. Pre- and post-treatment lesion biopsies confirmed tumor cell alpha(v) integrin expression, as well as CNTO 95 penetration of the tumor and localization to tumor cells in association with reduced bcl-2 expression. A lesion in one patient (10.0 mg/kg) with stable ovarian carcinosarcoma was no longer detectable by FDG-PET by day 49. Exposure to CNTO 95 seemed to increase in a greater-than-dose-proportional manner; dose-dependent mean half-life ranged from 0.26 to 6.7 days. CONCLUSIONS: CNTO 95 was generally well tolerated. Six patients received extended therapy, including one patient with a prolonged response. Biopsy data confirmed tumor localization and pharmacodynamic activity.


Assuntos
Anticorpos Monoclonais/efeitos adversos , Anticorpos Monoclonais/farmacocinética , Antineoplásicos/efeitos adversos , Antineoplásicos/farmacocinética , Integrina alfaV/metabolismo , Neoplasias/tratamento farmacológico , Adulto , Idoso , Relação Dose-Resposta a Droga , Feminino , Humanos , Imuno-Histoquímica , Integrina alfaV/imunologia , Imageamento por Ressonância Magnética , Masculino , Dose Máxima Tolerável , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons , Resultado do Tratamento
20.
Magn Reson Med ; 56(5): 993-1000, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17036301

RESUMO

Rapid T(1)-weighted 3D spoiled gradient-echo (GRE) data sets were acquired in the abdomen of 23 cancer patients during a total of 113 separate visits to allow dynamic contrast-enhanced MRI (DCE-MRI) analysis of tumor microvasculature. The arterial input function (AIF) was measured in each patient at each visit using an automated AIF extraction method following a standardized bolus administration of gadodiamide. The AIFs for each patient were combined to obtain a mean AIF that is representative for any individual. The functional form of this general AIF may be useful for studies in which AIF measurements are not possible. Improvements in the reproducibility of DCE-MRI model parameters (K(trans), v(e), and v(p)) were observed when this new, high-temporal-resolution population AIF was used, indicating the potential for increased sensitivity to therapy-induced change.


Assuntos
Neoplasias Abdominais/diagnóstico , Algoritmos , Imagem Ecoplanar/métodos , Gadolínio DTPA , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Neoplasias Pélvicas/diagnóstico , Neoplasias Abdominais/irrigação sanguínea , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Artérias/patologia , Artérias/fisiopatologia , Simulação por Computador , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Biológicos , Modelos Estatísticos , Neoplasias Pélvicas/irrigação sanguínea , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA