1.
Phys Med ; 121: 103370, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38677196

RESUMO

The Leksell Gamma Knife® Perfexion™ and Icon™ have a unique geometry, containing 192 60Co sources with collimation for field sizes of 4 mm, 8 mm, and 16 mm. 4 mm and 8 mm collimated fields lack lateral charged particle equilibrium, so accurate field output factors are essential. This study performs field output factor measurements for the microDiamond, microSilicon, and RAZOR™ Nano detectors. 3D printed inserts for the spherical Solid Water® Phantom were fabricated for microDiamond detector, the microSilicon unshielded diode and the RAZOR™ Nano micro-ionisation chamber. Detectors were moved iteratively to identify the peak detector signal for each collimator, representing the effective point of measurement of the chamber. In addition, field output correction factors were calculated for each detector relative to vendor supplied Monte Carlo simulated field output factors and field output factors measured with a W2 scintillator. All field output factors where within 1.1 % for the 4 mm collimator and within 2.3 % for the 8 mm collimator. The 3D printed phantom inserts were suitable for routine measurements if the user identifies the effective point of measurement, and ensures a reproducible setup by marking the rotational alignment of the cylindrical print. Measurements with the microDiamond and microSilicon can be performed faster compared to the RAZOR™ Nano due to differences in the signal to noise ratio. All detectors are suitable for field output factor measurements for the Leksell Gamma Knife® Perfexion™ and Icon™.


Assuntos
Imagens de Fantasmas , Impressão Tridimensional , Radiometria , Radiocirurgia , Radiocirurgia/instrumentação , Radiometria/instrumentação , Método de Monte Carlo
2.
Rep Pract Oncol Radiother ; 16(3): 110-4, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-24376966

RESUMO

BACKGROUND: Fracture of the femur is the most frequent late complication in patients with soft tissue sarcomas (STS) who receive external beam radiotherapy after limb-sparing surgery. AIM: To reduce the risk of bone fracture following radiotherapy of STS of the thigh, we minimized the dose to the femur and to surrounding normal tissues by applying intensity modulated radiation therapy (IMRT). We report preliminary results of post-surgery IMRT of the thigh in patients with STS in this extremity. MATERIALS AND METHODS: 10 adult patients undergoing post-operative radiotherapy of STS of the thigh were treated using IMRT. Clinical IMRT plans with simultaneous integrated boost (SIB) and 3-phase three-dimensional conformal radiotherapy (3D-CRT) were designed to adequately treat the planning target volume and to spare the femur to the largest extent possible. Dose distributions and dose-volume histograms were compared. RESULTS: For either technique, a comparable target coverage was achieved; however, target volume was better covered and critical structures were better spared in IMRT plans. Mean and maximum doses to OAR structures were also significantly reduced in the IMRT plans. On average, the mean dose to the femur in 3D-CRT plans was about two times higher than that in IMRT plans. CONCLUSION: Compared with 3D-CRT, the application of IMRT improves the dose distribution within the concave target volumes and reduces dose to the OAR structures without compromising target coverage.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA